A hospital door schedule is written department by department, because no two departments ask the same thing of a door. A ward door must resist a quiet attack at night without waking patients. An accident and emergency door must take constant use from trolleys and the public while keeping treatment areas controlled. A pharmacy door must resist a determined attack on controlled drugs. A plant room door must keep thieves away from copper and cable while carrying a fire rating. The schedule below sets out the rating each opening needs, and the evidence to ask for before the order is placed.
- SR3 to SR4Forced entry ratings for pharmacy doors and hatches
- SRA and SRBQuiet-attack ratings for doors near sleeping patients
- EI 30 to EI 120Fire ratings for compartmentation and escape routes
- 800 or more peopleEnhanced tier under Martyn’s Law for large hospitals
Wards: quiet doors that still resist attack
Wards sleep a few metres from corridors and service doors, so the threat there is the quiet intruder at night, not a noisy forced entry. Patients sleep while corridors stay in use, and a door that slams or rattles will be wedged open within a week. LPS 2081 covers stealth attack with quiet tools, rated SRA at one minute and SRB at three minutes, and it suits doors near sleeping patients. The LPS 2081 standards page sets out the two ratings.
Quiet operation is part of the specification, not an extra. Specify quiet closers and ironmongery that operates with little effort, and hold-open linked to the fire alarm so the door closes when the alarm sounds. A heavy self-closer that slams will be wedged open, and a door that staff wedge open has no rating at all in practice. A vision panel lets staff see into a room without opening the door, which keeps the corridor quiet and the room observed at the same time.
In mental health wards, doors also need to resist ligature risk, and that need is specified alongside the security rating, not instead of it. The rating still has to be proved by test evidence naming the doorset as supplied, and any change to the leaf, frame or ironmongery after the test needs fresh evidence. Keeping an LPS 1175 rating valid covers the changes that cause problems.
Accident and emergency: the door that takes the most use
Emergency departments receive the public at all hours, which brings aggression toward staff and unauthorised access to treatment areas. The entrance has to stay welcoming while the clinical areas behind it stay controlled, so the doors at the boundary carry the rating and the access control. SR2 doorsets with access control are the usual specification for an emergency department entrance. The healthcare sector page sets out the threats a hospital estate faces.
These doors take more use than any other doors in the building. Trolleys, wheelchairs and beds pass through them all day, so the ironmongery and closers must suit the number of movements a day, not just the size of the leaf. Cross-corridor doorsets need to withstand constant opening and closing and regular impact from trolleys and wheelchairs, and a doorset that cannot take that use will be damaged, wedged or propped before the year is out.
Control at the emergency department is about who passes, not about locking the building down. A staffed reception, access control on the doors into treatment areas, and a clear route out for staff who need to leave a bay all work together. Security must never block escape, and every rated door on an escape route must also carry the right fire rating and release on alarm. The SR2, SR3 and SR4 guide explains what each rating resists.
Pharmacy and drug stores: the highest rating in the building
Pharmacies hold controlled drugs, which makes them a target for burglary and robbery, so pharmacy doors carry the highest rating in the building. SR3 or SR4 doors and hatches are the usual specification, and the hatch, the door, the frame and any pass-through are rated as one assembly. The hatch is a hole in a rated wall, and if the wall resists SR3 and the hatch resists nothing, the hatch is the route in. Security hatches carry the same rating thinking as the doors they serve.
Ask for third-party test evidence naming each product and its rating before the order is placed. A certificate for a different model, a different size or a different set of options does not cover what is being ordered, and a supplier’s own test sheet is not the third-party evidence a checker asks for. The evidence must name the doorset as supplied, with the frame, the ironmongery and the fixings that were tested with it.
Access to the pharmacy should be limited to named staff, and the record of who entered should be kept. 10 steps to specify an LPS 1175 door covers the specification from the first measurement to the handover pack.
Plant rooms and medical gas stores: one doorset for theft, tampering and fire
Plant rooms and energy centres are attacked for copper and cable, and medical gas stores hold items with the potential for harm, so both need the same SR2 or SR3 thinking as the pharmacy. These rooms often sit away from the main building, which makes them easier to approach unnoticed, and they are checked less often than the wards. A doorset that resists forced entry and carries the fire rating the strategy requires answers both problems in one assembly.
Ventilation must not create a weak point. A louvre or vent that lets air through and lets a tool through at the same time has undone the rating, so the ventilation and the doorset must be specified together. Where the fire strategy requires it, the doorset carries a fire classification alongside the security rating, tested on the same construction with separate evidence for each. The plant room door requirements guide covers fire separation, louvres, locking and clear width in detail.
Locking for plant rooms is about staff and contractors, not the public. Keyed access for named staff, a written key register, and a rule that contractors are let in rather than given a key all keep the room controlled without slowing maintenance down. External plant rooms need the same thinking, with weather and corrosion handled in the specification. The fire ratings page sets out the E, EW and EI classes and the 30 to 120 minute periods.
Records, imaging and pathology: doors that protect what is inside
Records stores hold patient records, so their doors sit at SR2 with access limited to records staff. The threat is not a forced entry in the open but a quiet entry by someone who should not be there, and a door with a controlled lock and a record of entry answers it. The same thinking applies to equipment stores, which hold items with street value, and to pathology laboratories, where access control keeps the public out of rooms that hold samples and chemicals.
Imaging suites need a different kind of protection. MRI suites need RF shielded rooms, specified by attenuation in dB over a frequency range, and often magnetic shielding as well. The two are different things and both need to be in the specification, because RF shielding alone does not answer the magnetic need, and shielding fitted after the room is built costs more and performs worse than a coordinated design. The MRI and RF shielded rooms guide covers attenuation, penetration points and acceptance testing, and MRI shielded rooms sets out the product range.
Order the doorset, not the leaf: frame, ironmongery, closer and access control are all part of the tested assembly, and a change to any of them can void the rating.
Corridors, cross-corridor doors and the routes between departments
Complete evacuation of a hospital is often impractical, so the usual approach is progressive horizontal evacuation: moving occupants from the fire-affected area through a fire-resisting compartment line to an adjoining area that protects them. The compartment lines and the fire doors in them must be reliable, because if they cannot be relied on, the evacuation strategy for the hospital is severely compromised. Every cross-corridor door is part of that line, not just a door between two rooms.
Cross-corridor doorsets need to withstand constant opening and closing and regular impact from trolleys and wheelchairs, and HTM 05-02, the Firecode guidance for the design of healthcare premises, is the document that sets out what hospital fire doors must do. Fire doors should be fitted with an automatic self-closing device, and where a door is held open it must be on an electrically operated release that is fail-safe, so a fault or loss of power triggers the release automatically. Doors fitted with an automatic release should be closed at a set time each night and remain closed throughout sleeping hours.
Escape routes need doors that open in the direction of escape and never obstruct the circulation space. Revolving doors and turnstiles are not acceptable on escape routes, and a door that staff wedge open or block with a trolley has no rating in practice, however long its test result. The fire door regulations guide for commercial buildings explains what the responsible person must do, and the dual certification guide explains how fire and security ratings sit together in one doorset.
Access control and the door that must fail safe
Access control in a hospital is about named people, not about locked buildings. Fobs and codes admit staff to the areas their role needs and keep the public out of treatment, records and plant areas, and the record of entry shows who was where and when. One credential should admit one person, so a door that lets a second person follow through unchallenged has a gap in it, and busy corridors are where that gap is used most.
Every access controlled door on an escape route must release on fire alarm, and the release must be fail-safe: a fault or a loss of power must open the route, not lock it. The behaviour on power failure should be written into the specification for each door, not left to be found out during an alarm. A locked ward door that traps patients is a failure, not a protection, and the access control, the fire strategy and the evacuation plan must be agreed together, with the fire officer involved early.
Large hospitals hold well over 800 people at peak times, which puts them in the enhanced tier of Martyn’s Law, the Terrorism (Protection of Premises) Act 2025. The Act received Royal Assent in April 2025 and names no product and no rating, but enhanced tier premises must consider physical protective measures as part of their preparedness. The regulator is the Security Industry Authority, go-live is expected in spring 2027, and an implementation period of at least 24 months applies before enforcement, with an advisory-first approach. The Martyn’s Law guide for premises sets out the tiers, and security doors carry the ratings the plan can name.
Writing the hospital door schedule: one line per opening
The schedule should name one doorset per opening, with the security rating, the fire rating and the access method for each. The ratings below are typical starting points for a hospital threat assessment, to be confirmed against the fire strategy and the risk assessment for the building.
| Opening | Security rating | Fire rating | Access |
|---|---|---|---|
| Ward door | SRA or SRB | EI 30 or EI 60 | Staff fob, hold-open on alarm |
| A and E entrance | SR2 | EI 60 | Staffed reception, access control |
| Pharmacy door | SR3 or SR4 | EI 60 | Named staff only |
| Pharmacy hatch | SR3 or SR4 | To match the wall | Named staff only |
| Plant room door | SR2 or SR3 | EI 30 or EI 60 | Keyed staff access |
| Medical gas store | SR2 or SR3 | EI 30 | Keyed staff access |
| Records store | SR2 | EI 30 | Records staff only |
| MRI suite door | RF shielding in dB | EI 30 | Staff only |
A schedule that names a rating for the building and leaves each opening to the contractor invites a mix of products, and the checker will have nothing to compare the submittal against. Ask for the evidence before the order is placed: test certificates naming each product and its rating, the ironmongery schedule, the access control register and the inspection intervals, all in the handover pack. The LPS 1175 standards page sets out the full rating scale from A1 to H20.
What rating should a hospital pharmacy door have?
SR3 or SR4 doors and hatches are the usual specification for a pharmacy holding controlled drugs. Rate the hatch, the door, the frame and any pass-through as one assembly, and ask for third-party test evidence naming each product and its rating before the order is placed.
How do you secure a ward without disturbing patients?
Specify doorsets tested to LPS 2081 for stealth attack, rated SRA at one minute or SRB at three minutes, with quiet closers and ironmongery that operates with little effort. Hold-open linked to the fire alarm keeps the door open during the day and closed when the alarm sounds, and a door that slams will be wedged open.
Can one door be both fire rated and security rated?
Yes. Dual-rated doorsets carry a fire classification such as EI 60 alongside an LPS 1175 rating, but only where each has been tested on the same construction, with separate evidence for each. Check that the locks, closers and access control release correctly on fire alarm.
Do hospital fire doors need self-closing devices?
HTM 05-02, the Firecode guidance for healthcare premises, says fire doors should be fitted with an automatic self-closing device, with limited exceptions. Where a door is held open, it must be on an electrically operated release that is fail-safe, and doors fitted with an automatic release should be closed at a set time each night and remain closed throughout sleeping hours.
What should the handover pack contain?
Test certificates for every rated product, the rating codes written in full, the ironmongery schedule, the access control register and the inspection intervals for closers, seals and locks. If a certificate is missing, the rating is unproven, however the product is described.
What a hospital door rating does not prove
A rating on a hospital door proves one thing: the tested doorset held its rating in the test. It proves nothing else. Treat the certificate as a narrow statement, and ask what it leaves out before the order is placed.
It does not prove the door suits the ward. A ward door must be wide enough for a bed, easy enough to open with a bed in front of it, and sure enough to close and latch behind the last patient.
It does not prove fire and security together. A pharmacy door must hold fire and resist forced entry, and the two jobs need two sets of evidence on one assembly: a fire classification to EN 1634-1 and a forced entry rating to LPS 1175 or PAS 24. A steel leaf is strong, but strength is not a security rating, and a door rated FD60 can still fail a forced entry test.
It does not prove the door is safe on a mental health ward. Doors on those wards must leave nothing to hold, with handles, locks and hinges shaped so they cannot be used as a ligature point, and vision panels that allow observation without opening the door. The fire rating still applies on top: a ligature resistant door that does not close and latch has no fire performance, whatever its other qualities.
It does not prove the door will close in a fire. A door that stands open for observation needs a hold-open device to BS EN 1155 that releases when the alarm sounds, and a closer sized to BS EN 1154 for the leaf. A wedge, a chair or a hook on the wall has no such release, and a door held open by one of those will stand open in a fire.
Mistakes that break a hospital door order
Most hospital door orders fail in small ways. Each mistake below has the same result: a door that looks right and cannot be proved.
| Mistake | Why it fails | What to do instead |
|---|---|---|
| Leaf ordered without the frame | The rating belongs to the tested assembly, not the leaf alone. | Order leaf, frame, seals and hardware as one doorset. |
| Fire rating with no security evidence | A pharmacy door that holds fire can still fail a forced entry test. | Ask for both sets of evidence on one assembly. |
| Closer too strong for the leaf | Staff wedge the door open and the fire performance is lost. | Size the closer to BS EN 1154 for the leaf as built. |
| Standard handles on a mental health ward | Handles that can be held become a ligature point. | Fit ligature resistant hardware on those wards. |
| No test report on site | Without the report, nobody can check the door against what was tested. | File the test report with the building records. |
Keep the evidence with the door. The test report, the classification and the hardware schedule should travel with the doorset, so the fitter and the inspector can check what was bought against what was tested. For the fire rules behind the order, see our fire door regulations for hospitals guide, and for the ligature resistant doorset, see our anti-ligature doors guide.
Wards after dark: the door that keeps the ward quiet and shut
A ward door shuts a hundred times a day and must shut quietly each time, yet hold its line when someone tries it. The leaf takes a closer that pulls it home without a slam, hinges that carry the weight without a creak, and a lock that holds the leaf shut without a rattle, because a ward that cannot sleep cannot heal. The door that guards a ward takes a grade that follows the room behind it, and the grade on the order follows the risk, not the size of the opening.
Accident and emergency takes the most use of any door in the hospital, because trolleys, beds and people pass through it through the day and the night. The leaf, the hinges and the closer wear fastest where the traffic is heaviest, so the doors on that route are checked most often and the closer that has lost its pull is changed before the leaf starts to stand open.
The doors between departments take cross-corridor leaves that shut on their own and open with one push, because staff move between wards with their hands full. A cross-corridor door must open for a bed and shut behind it without a hand on the leaf, and the closer on such a door takes the power the leaf needs, no less than EN 3 to BS EN 1154 where the leaf must also hold fire back.
The pharmacy and the plant room: where the highest grade sits
Pharmacy and drug stores take the highest rating in the building, because the rooms behind them hold controlled drugs. A pharmacy door takes a leaf proved to LPS 1175, with B3 holding three minutes, C5 five minutes and D10 ten minutes under Issue 8.2, dated September 2024, and the category on the order follows what the room holds. A reader beside the leaf opens it for the pharmacist and no one else, and the list behind the reader decides which fob opens which door.
Plant rooms and medical gas stores take one doorset for theft, tampering and fire, because the room behind the leaf holds the gas the wards run on and the plant the building runs on. The leaf must hold fire back for its period and hold an intruder out for its rating, with both proofs on the same leaf, the frame and the seals proved together for both. A leaf that carries one proof and not the other leaves the room open on one side.
Records, imaging and pathology take doors that protect what is inside, because the rooms hold records, films and samples the hospital cannot replace. Each door takes the grade the room behind it demands, and the schedule names every opening with the leaf, the rating, the lock and the reader beside each one, so the door that arrives matches the door that was ordered. Access control across the hospital is settled door by door before the order goes out: a leaf on an escape route opens when the power fails, while a leaf that guards drugs or records stays shut, because that answer decides what the leaf does in a blackout.
| Position | Grade | What the doorset must prove | What to check |
|---|---|---|---|
| Ward | LPS 1175 B3 | Three minutes against tools | Leaf, closer, lock |
| Accident and emergency | LPS 1175 B3 | Three minutes against tools | Leaf, hinges, closer |
| Pharmacy | LPS 1175 C5 | Five minutes against tools | Leaf, reader, lock |
| Plant room | LPS 1175 C5 | Five minutes against tools, FD60 | Leaf, seals, lock |
| Records store | LPS 1175 C5 | Five minutes against tools | Leaf, lock, reader |
The periods for the shared parts of a hospital are set out in the fire door regulations hospitals guide, and the two ratings side by side are covered in the LPS 1175 versus PAS 24 guide. The doors that must hold both fire and forced entry are covered in the security door maintenance checklist, and the columns a schedule needs are set out in the how to specify security doors guide.