ArxBridge
High Speed Doors
High speed doors for warehouses, food sites and logistics: cycle time, safety devices, fire and security proof, chilled areas and one schedule.
- ✓Third-party test evidence with every product
- ✓Written specification you can issue to tender
- ✓Supplied and installed across the UK
Get a free project quote
Rating, written specification and budget range within one working day.
Confidential. No cost, no obligation.
Third-party tested
Evidence with every quote
UK manufactured
Made to your sizes
One accountable team
Specify, supply, install
Confidential handling
Details never shared
A high speed door opens and shuts in seconds, and the seconds are the point. A forklift that waits loses the shift a few seconds at a time, and a chilled room that stands open loses the cold it paid to hold. The fast door keeps the bay moving and the air where it belongs, because it spends less time open.
The order starts with the bay, not with the leaf. A loading bay that takes lorries all day asks for a different door from a food line where staff pass through with trolleys, and a chill store that must hold its temperature asks for different seals from a dry store that only needs the draught kept out. The work, the traffic and the air the room must hold decide the door before the leaf is chosen.
Every fast door on the site sits on one schedule, and an order that names each one plainly gets the right door on the right opening. The warehouses and logistics sector page sets out the buildings these doors guard, and the loading bay doors guide covers the bays where the fast door works hardest.
- BS EN 12453Safety in use of power operated doors
- BS EN 13241Product standard for industrial doors
- FD30 / FD60Fire resistance periods tested to EN 1634-1
- LPS 1175 B3 / C5 / D10Forced entry ratings, three, five and ten minutes
Where the fast door earns its keep: bays, chill stores and food lines
A loading bay is where the fast door earns its keep. Lorries arrive all day, forklifts run in and out, and the door opens for each vehicle and shuts behind it. Every second the opening stands open lets heat out and dust in.
A food line asks for a different duty. Staff pass through with trolleys, hands full, and the door must open for them and shut behind them without anyone touching it. The leaf must take the daily washdown, so the finish belongs on the order beside the leaf.
A chill store asks for the tightest shut of all. The cold air inside is paid for by the hour, and the door is the seal between the store and the warm bay. The seals round the leaf must stay soft, because a seal that goes hard leaves a gap the cold escapes through. The warehouse security doors guide covers the doors on the stores behind the bays.
Cycle time and throughput: the seconds that set the shift
Cycle time is the time the door takes to open and shut again, and it sets how many crossings the bay can take in an hour. Count the crossings the busiest hour brings, then order a door whose cycle time leaves room for them.
The motor and the drive set the speed. A heavier leaf needs a stronger drive, and a door that faces the wind needs a drive that can push the leaf shut against it. The wind load belongs on the order beside the leaf.
Throughput on paper is not throughput at the bay. The rated cycles count a door opening and shutting with nothing in the way, while the real bay holds forklifts waiting and trolleys crossing two at a time. Order for the real crossings, not the rated ones, and the roller shutter cost factors guide works through what each step up the scale adds to the build.
The motor runs hot by mid-shift, and the count shows it first
A fast door through a shift opens and shuts hundreds of times, and the count is what the order must carry. The busiest hour brings the most crossings, and the motor that drives the door takes the heat of every one of them, so a drive proved for the average hour will run hot at the peak and slow when the bay needs it fastest. The order names the count beside the bay, and the drive is chosen for the crossings the busiest hour brings, not for the quiet hours between them. A door that opens for forklifts all day and a door that opens for trolleys on a food line do not carry the same count, so the count is set bay by bay, not site by site.
Heat shows first in the motor, then in the guides and the curtain. A motor that runs hot slows the door, a guide out of true lets the leaf wander in its fixings, and a curtain that has torn lets the cold out of the chill store, so the round looks at the motor, the guides and the curtain in turn. The monthly walk takes each bay in turn, and the motor, the guides and the curtain are looked at together, because heat in the motor and wear in the guides arrive in the same shift. The fire door inspection checklist names the checks the monthly walk should make, and the guide to keeping the rating valid names what breaks one. A seal that has gone hard in the cold lets the air through even when the door stands shut, so the seals are checked with the curtain, not after it.
| Shift point | What the door does | What the round checks |
|---|---|---|
| Start of shift | First crossings of the day | Motor cool, curtain whole, guides true |
| Mid-shift peak | Most crossings in the hour | Motor heat, drive speed, safety edge |
| End of shift | Last crossings, door shut for the night | Curtain, seals and photocells |
| Overnight | Door stands shut till morning | Seals soft, guides fixed, motor at rest |
The bay beside it keeps running while the broken door waits
When one bay shuts for repair, the bay beside it takes its traffic, and the door on that bay must keep running through the extra crossings. Spare sections of curtain, spare guide parts and a spare photocell are held on site for the door that keeps working, because a bay with no spare curtain waits for the part to arrive before it can open again. The door that comes back from repair is tested with its safety devices as one assembly, and the photocells, the safety edge and the loops are proved with the door before the bay opens again.
The order lists every bay on its own line, with the count, the safety devices and the rating beside each one, so each bay gets the door the order names. The loading bay doors guide names the bays where the fast door earns its keep. The roller shutter regulations guide lists the rules a powered shutter must meet, and the warehouse security doors guide names the doors behind the bays. A bay door that needs replacing goes on the security door enquiry checklist, with the cycle count and the safety devices beside it.
Safety devices that stop a fast leaf: photocells, edges and loops
A fast leaf must stop before it hurts someone, and BS EN 12453 sets out how a powered door must be made safe to use. Photocells watch the opening and stop the leaf when a person or a vehicle breaks the beam, a safety edge stops the leaf on contact, and loops in the floor sense the vehicle waiting to pass.
Each device belongs on the order beside the door, because a door ordered without them has no proven safety at all. The devices must be tested on the round, and a device that no longer stops the leaf leaves the door unproved.
People and forklifts should not share one opening. A pedestrian door beside the fast door lets staff walk through on foot, so the fast leaf opens only for vehicles, and the opening force on the pedestrian door must stay below 30 N for the first 30 degrees of travel and below 22.5 N beyond, under BS 8300 and Approved Document M. The gate automation guide covers the drives and the safety devices on the gate line.
The leaf, the guides and the motor: what a fast door is made of
The leaf takes the knocks of the working day, so it must be built for them. A PVC curtain bends when a forklift clips it and is repaired in sections, while an insulated panel leaf holds the temperature and takes a harder knock. The leaf follows the bay, not the catalogue, and the repair belongs on the file beside the leaf.
The guides hold the leaf against wind and pressure, and a leaf that blows out of its guides is a door that cannot shut. The guides must be fixed to a wall that can hold them, and the fixings belong on the same line as the leaf.
The motor, the drive and the power behind them decide whether the door keeps working when the site needs it most. A door that must open on power loss needs a backup the order names, and the drive should be chosen for the weight of the leaf it carries. The roller shutter regulations guide sets out the rules a powered shutter must meet.
The leaf must shut against the wind, not just against the traffic
A fast door on an exposed bay faces more than traffic. Wind on the outside face and pressure from inside the building both push the leaf, and a leaf that blows out of its guides is a door that cannot shut, so the wind load belongs on the order beside the leaf. The guides must be fixed to a wall that can hold them, and the fixings belong on the same line as the leaf, because a guide fixed to a weak wall pulls away under the load the wind puts on it.
Pressure works the other way too. A warm building pulls cold air in at the bottom of the opening and pushes warm air out at the top, and a leaf that shuts fast in a frame that lets air through has failed half its job. The seals round the leaf must stay soft, because a seal that goes hard leaves a gap the air escapes through, and the drive must be chosen for the weight of the leaf and the wind it must push shut against, not for the calm days between the gusts. The rules a powered shutter must meet are listed in the roller shutter regulations guide, and the bays where the fast door works hardest are named in the loading bay doors guide.
| Load | What it does | What the order names |
|---|---|---|
| Wind on the leaf | Pushes the leaf out of its guides | Wind load, guide fixings |
| Pressure inside | Pulls air through the frame | Seals, frame, drive |
| Forklift knock | Bends the curtain | Leaf type, repair in sections |
| Daily washdown | Wears the finish | Finish, leaf material |
What breaks first: the curtain, the guides and the spare parts on the quote
The leaf takes the knocks of the working day, so it is the part that breaks first. A PVC curtain bends when a forklift clips it and is repaired in sections, while an insulated panel leaf holds the temperature and takes a harder knock, so the leaf follows the bay, not the catalogue, and the repair belongs on the file beside the leaf. The guides come next: a guide that has worked loose lets the leaf move in its fixings, and a photocell that no longer stops the leaf leaves the door unproved.
The quote should hold the spares the bay will need, with the curtain sections, the guide parts and the photocell named beside the door, because a bay with no spare curtain is a bay shut while the part is ordered. Walk the bays once a month and look at every leaf, guide and motor in turn, and each fault gets written down the same day, with the bay and the fault beside it. What each step up the scale adds to the build is priced in the roller shutter cost factors guide, the sizes and the fitting of the closer are named in the fire door closers guide, the build is broken down step by step in the security door cost factors guide, and the doors on the stores behind the bays are named in the warehouse security doors guide.
Chilled rooms and clean air: holding the temperature at the opening
A chilled room holds its temperature only while the door holds the opening shut. The fast cycle is the first defence, and the seals round the leaf are the second, because a leaf that shuts fast in a frame that lets air through has failed half its job.
Cold air meets warm air at the opening, and the meeting leaves condensation and frost. The seals must stay soft in the cold, because a seal that goes hard in a chill store leaves a gap the frost grows through, and the threshold must let trolleys pass without a trip, so the floor in front of the door must be kept clear.
Fire and forced entry on the same leaf: two proofs, one door
Where one leaf must hold fire and hold back attack, order both proofs together and name both on the same line. The fire test proves the period and the forced entry test proves the minutes, and each test names the same leaf, frame and hardware, because a leaf proved for one job alone leaves the other side open.
The period follows the compartment the door guards. A door on a corridor takes FD30, a door on a compartment wall takes FD60, and a door that guards a smoke path takes FD30S, with the seal proved to BS EN 1634-3, to Sa for smoke at room temperature and S200 for smoke at 200 degrees Celsius. The gap round a fire door leaf must stay at 4 mm, because a wider gap lets fire and smoke past.
Forced entry is proved to LPS 1175, with B3 holding three minutes against category B tools, C5 holding five minutes against category C tools and D10 holding ten minutes against category D tools, all under Issue 8.2, dated September 2024. How the two proofs sit together is worked through in the fire and security doors dual certification guide, and the sizes and the fitting of the closer are covered in the fire door closers guide.
Readers, intercoms and the yard: who opens the fast door
The fast door should open for the people who belong in the bay and stay shut for the rest. A card or a fob opens the door for the staff who use the bay every day, and a fob can be stopped when staff leave.
Drivers who arrive at the yard take a remote or an intercom at the gate, so the door opens for the vehicle that has booked in. The record should name who opened the door and when, because the record matters as much as the leaf, and a door that opens for anyone is a door with no purpose.
The access control must not trap anyone inside. A door that locks from the outside and will not open from the inside is a danger in a bay where staff work all day, so the release inside the bay works on power failure as well as on alarm. Readers, fobs and biometrics in the lane are covered in the security turnstiles guide, and the grades and the parts behind a working fire door are covered in the fire door hardware guide.
One schedule for the whole site: every opening on one line
Put every opening on one list before the order goes out, with the leaf, the cycle time, the safety devices and the rating written beside each position, so the door that turns up is the door that was tested. A schedule that names one door for the whole site leaves the fitter to guess which leaf goes where, and a guess is not a proof.
Read two quotes side by side and check that each one names the same leaf, the same motor and the same safety devices. A quote that leaves the safety edge off the list has not saved money, it has only moved the cost to the day the door is fitted. The security door cost factors guide sets out what each step up the scale adds to the build, and the how to specify security doors guide sets out the columns the schedule needs.
Walk the bays once a month and look at every leaf, guide and motor in turn. A curtain that has torn, a guide that has worked loose or a photocell that no longer stops the leaf each gets written down the same day, with the bay and the fault beside it. The fire door inspection checklist names what each round should look for, and the keeping an LPS 1175 rating valid guide sets out what breaks a rating.
| Position | Door | Rating | What to check |
|---|---|---|---|
| Loading bay | High speed PVC door | BS EN 12453 | Photocells, safety edge, loops |
| Chill store | Insulated high speed door | FD30 | Seals, closer, motor |
| Food line | High speed fabric door | BS EN 13241 | Leaf, guides, washdown |
| Escape route | Fire door | FD30S | Seals, closer, release |
| Yard entrance | High speed door and gate | LPS 1175 B3 | Reader, release, motor |
A fast door earns its keep in seconds, so the cycle time, the safety devices and the seals must all sit on the same schedule.
How fast should a high speed door open?
Fast enough that the forklift does not wait and the chilled air stays in. The cycle time follows the crossings the busiest hour brings, not the door the catalogue shows first.
What safety devices does a high speed door need?
Photocells, a safety edge and loops, to BS EN 12453. The door must fail safe when a device fails, so the devices are tested on the round.
Can a high speed door hold a fire rating?
Yes, where the leaf has been tested for the job. The fire test to EN 1634-1 names the period, FD30 or FD60, and the forced entry test to LPS 1175 names the minutes, B3, C5 or D10, and each test must name the same leaf, frame and hardware.
What holds the temperature in a chill store?
The fast cycle, the seals and the leaf that shuts tight. Where the room must stay coldest, two fast doors work as an airlock and never open together.
Who checks high speed doors?
The person who runs the site, on the routine the site keeps. Each round looks at the leaf, the guides, the motor and the safety devices, and every fault found is written down the same day.
Ordering this alongside other openings? The security door enquiry checklist lists what to send for each one: location, size, rating and hardware.
Get a free quote
Related
More in guides for specifiers
Products
One supplier for the whole building envelope
Ready to specify your project?
Free assessment, written specification and test evidence. Reply within one working day.