A port fills with crews and visitors who do not know its quays, so fire doors take their period from the room behind them, terminal to plant room.
- ✓Third-party test evidence with every product
- ✓Written specification you can issue to tender
- ✓Supplied and installed across the UK
Get a free project quote
Rating, written specification and budget range within one working day.
Confidential. No cost, no obligation.
Third-party tested
Evidence with every quote
UK manufactured
Made to your sizes
One accountable team
Specify, supply, install
Confidential handling
Details never shared
A port is a working quay where crews, visitors and drivers move among cargo, fuel and machinery, and the fire doors are the leaves that hold a fire where it starts while those people find the way out. The period on each door follows the room behind the leaf, because a terminal, a stores room and a plant room ask different things of the doors that guard them.
The rules for the shared parts of any transport building are set out in the transport hub security requirements guide, and the rules for the stores beside the quay are set out in the warehouse security doors guide. The port order names every door in the building, with the period and the hardware beside each one.
The port draws up its fire plan before a single leaf is ordered, naming the period each opening must hold and the route each person must follow, and the order follows that plan leaf by leaf.
- FD30 / FD60Fire periods to EN 1634-1
- Sa / S200Smoke proof to BS EN 1634-3
- EN 3Smallest closer power to BS EN 1154
- One listEvery port door named
Terminals, stores and back offices: one quay, three periods
A port holds three kinds of room under one fence line: terminals full of passengers and paperwork, stores full of cargo and spares, and back offices full of records and keys. The rules follow the rooms, because a leaf between a terminal and a stores room must hold fire back while the people on the other side find the way out.
The terminals take the doors that let passengers and crews in and out, and each leaf must open for people who have never seen the building before. The stores take the doors that guard the cargo, and each leaf must hold fire back where the goods sit in boxes and crates. The route that joins them takes the doors the crews pass through, and each leaf takes the period the escape needs.
The plan names each opening with its door, so a leaf ordered for the stores never ends up guarding the terminal.
FD30 and FD60 on a quay: the periods each room takes
Each part of a port asks a different period of its doors, because the load behind each leaf is different. The terminal holds passengers and paperwork, the stores hold cargo and fuel, and the plant room holds the machinery that serves the whole quay, so the period is set by the room, never by the leaf alone.
EN 1634-1 gives a fire door its proof as minutes beside letters. The minutes run from 30 to 120, and the letters name what stayed on the far side of the leaf: the flames on their own, the flames with some of the heat, or the flames with the heat as well.
A leaf proved for the longer period weighs more and needs a deeper frame to carry it, so the figure on the quotation rises with the period. A leaf proved for 30 minutes must never fill an opening that needs 60, because the shorter proof is the one that fails first.
The terminal: passengers, luggage and the doors between them
A terminal is a busy room full of people with luggage, and the doors on it must hold their proof while letting passengers pass in and out all day. A glazed leaf lets the staff see the quay beyond it without opening the leaf, and the pane takes the same proof as the leaf, because the leaf and the glass are proved as one doorset.
The paperwork and the fittings in a terminal carry a fire load of their own, and the doors between the terminal and the stores must hold the fire where it starts. The stores side of that wall takes the period the stores demand, because the fire that starts among the cargo must stay among the cargo while the passengers move out.
For the windows on the same wall, the fire rated windows guide names what the pane must hold, and the fire rated glass cost guide works through what the glass itself adds to the order.
Stores and back offices: the doors behind the quay
The stores take the heaviest fire load on the quay, because the cargo and the fuel sit there all day. A stores leaf takes FD60, and the period follows the fire load, not the size of the room.
The back office takes the same care, because the records and the keys sit behind its doors. A back office leaf takes FD30 where the office sits beside the terminal, because the fire that starts among the cargo must not reach the records.
A stores leaf or a back office leaf may need a forced entry proof as well as a fire proof, because both rooms need the two together. LPS 1175 names the forced entry categories: B3 for three minutes, C5 for five and D10 for ten, all to Issue 8.2 of September 2024. The LPS 1175 vs PAS 24 guide sets the two ratings beside each other, the keeping an LPS 1175 rating valid guide names the faults that break a rating after fitting, and the fire and security doors dual certification guide shows how one doorset carries both proofs.
The plant room and the control room: what the back of quay doors must hold
The plant room holds the machinery and the electrical boards that keep the quay working, and the leaf that guards it takes the period the load behind it demands. A plant room leaf takes FD60, and the period follows the fire load in the room, not the size of the plant.
The control room beside the plant room takes the same care, because the systems that run the quay sit behind its leaf. A control room leaf takes FD60 where the room sits beside the plant room, because the fire that starts among the machinery must not reach the systems.
Some quay leaves must stay open while the working day runs, and those take a hold-open device proved to BS EN 1155, which releases the leaf the moment the alarm sounds. Anything wedged under a leaf to keep it open defeats the proof, because a leaf held open by a crate cannot shut when the fire reaches it.
When the alarm sounds: the routes a full port uses
Once the alarm sounds, everyone on the quay takes the route the building gives them, so the way out must be clear of anything in the way. Each door on that route opens with a single push from whoever reaches it, whether the power is on or off.
The route doors carry a smoke proof beside the fire period, proved to BS EN 1634-3. The proof has two marks: Sa for smoke at room temperature, S200 for smoke at 200 degrees. Smoke reaches the route ahead of the flames, because it moves faster than fire, and a seal works only where it touches the frame all the way round. How the doors hold smoke back while people move past them is set out in the smoke control doors guide.
The route lasts only as long as its weakest leaf, so every leaf on it takes the same period. Where one leaf carries a shorter proof than the leaves beside it, that leaf gives way first and the route fails with it. The fire door regulations retail guide shows the same care taken with shoppers in a store.
| Position | Door | Period | What to check |
|---|---|---|---|
| Terminal | Glazed leaf | FD30 | Leaf, glass, bar |
| Stores | Steel leaf | FD60 | Leaf, lock, seals |
| Back office | Steel leaf | FD30 | Leaf, lock, seals |
| Plant room | Fire leaf | FD60 | Leaf, seals, gap |
| Public route | Fire leaf | FD30 | Leaf, bar, closer |
Closers, seals and gaps on port doors: what the period rests on
A port leaf is opened more times in a day than most doors, so its closer works harder than most. BS EN 1154 sets EN 3 as the smallest closer power on a fire door, and the check is simple: open the leaf and watch it come home on its own. A closer that has lost its pull leaves the leaf standing open after the crew has passed, and an open leaf holds nothing back.
The leaf hangs with a 4 mm gap at its sides, so it moves without catching and the seal meets the frame once the leaf is shut. As the heat climbs toward 200 to 250 degrees the intumescent seal swells to shut that gap, unless paint laid over the seal stops it swelling. When a seal has slipped from its groove, the fault is written against its door on the day it is found, with the part and the date beside it.
Each hinge takes its share of the leaf through every opening of the day, and a hinge that has worked loose lets the leaf sag until it drags on the floor and smoke slips through the gap it leaves at the top. The fire door hardware guide names what the lock the key turns must do, and the fire door closers guide works through sizes and fitting for closers.
Ordering for a port: one list, every door on it
The whole port order sits on one list, a line for every door with the leaf, the period, the lock and the closer beside it, so the door that arrives is the door each room asked for. A list that names a single leaf for the whole quay leaves the fitter to guess which room takes which period, and a leaf fitted to the wrong room guards the wrong thing.
Before the order goes out, the quotation is read against the list, figure by figure, so every figure sits beside the door it belongs to. A figure left off the quotation still has to be paid, and a part added after the order costs more than the same part ordered with the building. The how to specify security doors guide names the columns the list must hold, and the security door cost factors guide works through what each step up the scale adds to the price.
Before the first ship each week the port tries its leaves in turn, starting at the terminal and finishing at the plant room. Any leaf that drags, any seal slipped from its groove, or any closer that has lost its pull is noted against its door on the day it is found, and the repair is booked while the fault is still small. The record stays with the port file, and what the visit should cover is set out in the fire door inspection checklist.
A port leaf holds only as long as the rooms behind it and the route beside it, so the period, the release and the closer must all sit on the same list.
What period should a port door carry?
FD30 or FD60, proved to EN 1634-1. The terminal takes FD30 and the stores take FD60, so the period follows the room the leaf guards, and the letters beside the minutes name what the doorset held back.
Can one leaf hold fire and forced entry?
Yes, where one doorset went through the fire test and the forced entry test as a single assembly, leaf, frame and seals together, so the report names both proofs.
Do port doors need panic hardware?
Yes, each leaf on the way out takes a panic bar proved to BS EN 1125, set across at least 60 percent of the leaf, so a single push throws the latch.
What period should a control room door carry?
A control room leaf takes FD60 where the room sits beside the plant room, because the fire that starts among the machinery must not reach the systems that run the quay.
Who checks the port doors?
The duty manager walks the round that covers every door, and each visit is written into the record the port keeps.