ArxBridge
Fire Door Regulations for Snooker Clubs
A snooker club keeps quiet tables beside a bar and a members room, so each leaf takes the fire period its room needs, FD30 at the front and FD60 behind it.
- ✓Third-party test evidence with every product
- ✓Written specification you can issue to tender
- ✓Supplied and installed across the UK
Get a free project quote
Rating, written specification and budget range within one working day.
Confidential. No cost, no obligation.
Third-party tested
Evidence with every quote
UK manufactured
Made to your sizes
One accountable team
Specify, supply, install
Confidential handling
Details never shared
A snooker club gives its entrance, its bar, its snooker hall and its members room an FD30 leaf, and its kitchen, its back office and its plant room an FD60 leaf. The rooms at the front hold fire back for 30 minutes, and the rooms at the back hold it back for 60, because the heat and the papers behind them ask for longer.
EN 1634-1 tests a doorset against fire and gives the period in minutes, from FD30 up to FD120. The letter after the number names what the leaf held back, E for flame alone, EW for flame with part of the heat, and EI for flame with the heat as well. A leaf marked FD30 therefore holds flame back for 30 minutes, and a leaf marked FD60 holds it back for 60 minutes.
A snooker club runs its evening on tables and frames in a quiet hall, which sets it apart from a bowling alley where the evening runs on lanes with pins at the far end. No machine stands in place of a table, so the club is not an arcade, and no caller runs the evening, so it is not a bingo hall. The fire door regulations for bowling alleys guide covers the lane venue, the fire door regulations for arcades guide covers the machine hall, and the fire door regulations for bingo halls guide covers the called session, while this guide stays with the tables, the bar and the members room of the snooker club.
- FD30 / FD60Periods to EN 1634-1
- Snooker hallWhere FD30 guards the tables
- KitchenFD60 behind the cookers
- One listEvery club leaf named
Seven rooms in a snooker club: the period each leaf takes
Seven rooms make up the club, and the period follows what each room holds. The seven rooms are the entrance, the bar, the snooker hall, the members room, the kitchen, the back office and the plant room.
FD30 sits on the entrance, the bar, the snooker hall and the members room, because all four stand where members and visitors pass through the evening. FD60 goes on the kitchen, the back office and the plant room, because the rooms at the back ask for a longer hold.
| Room | Period | Grade | What to check |
|---|---|---|---|
| Entrance | FD30 | B3 | Leaf, closer, seals |
| Bar | FD30 | B3 | Leaf, closer, gaps |
| Snooker hall | FD30 | B3 | Leaf, closer, vision panel |
| Members room | FD30 | B3 | Leaf, closer, seals |
| Kitchen | FD60 | C5 | Leaf, closer, seals |
| Back office | FD60 | C5 | Leaf, closer, gaps |
| Plant room | FD60 | C5 | Leaf, closer, seals |
Where the club wants a leaf that also resists forced entry, the fire period and the grade are proved on the same doorset, so one report holds both and the order names both together. The fire and security doors dual certification guide names how the two proofs sit on one leaf.
What FD30 and FD60 hold back in a snooker club
FD30 holds flame back for 30 minutes, and FD60 holds it back for 60, and the letter after the number says whether the heat was held back with the flame. A leaf marked E held the flame alone, a leaf marked EW held the flame with part of the heat, and a leaf marked EI held the flame with the heat as well.
The club needs the longer period where the fire would start hot and grow fast, and the shorter period where the room opens onto the way out. The kitchen, the back office and the plant room take FD60 for that reason, while the entrance, the bar, the hall and the members room take FD30. The fire door certification guide names what proof a leaf must carry before the club accepts it.
Sixty minutes behind the kitchen, office and plant room leaves
The kitchen holds the cookers and the gas that feed suppers between frames, so FD60 sits on its leaf and the leaf stays shut while the cookers are hot, because a fire that starts at a cooker grows fast and the hall beside it holds members at the tables. The fire door regulations for restaurants guide covers the kitchen that serves meals through the day.
The back office holds the membership lists, the fixture lists and the papers that run the club, so FD60 sits on its leaf as well and the leaf stays shut when the room is empty, because the papers behind it would feed a fire and the club would lose the records it runs on. The count from the cash desk runs in the back office too, behind the same FD60 leaf, once the bar shuts and the till is carried through.
The plant room holds the boards and the equipment that keep the water hot and the lights on, so its leaf takes FD60 as well. The plant room fire doors guide names in full what a leaf on that room must do, and the leaf stays shut because the boards behind it feed the whole club.
Entrance and bar: FD30 where members arrive for the evening
Members arrive at the entrance with cue cases over their shoulders, and visitors follow them in for a drink before the first frame, so the entrance leaf takes FD30 and stands on the way out as well as the way in. The leaf opens to members and their guests while the session runs, and it must open freely when the hall empties at the end of the evening.
A member pushing the entrance leaf meets a limit set by BS 8300 and Approved Document M, under 30 N across the first 30 degrees of swing and under 22.5 N after that, so the leaf opens for a person carrying a cue case or leaning on a stick.
The bar takes the takings of the evening behind an FD30 leaf that stays shut once the last drink is served, and the cash desk behind the bar counts the till behind that shut leaf. The counting room sits behind the bar as well, and its door stays shut while the count runs. The fire door regulations for casinos guide covers a venue that counts cash through the night.
Snooker hall and members room: FD30 beside the tables
The snooker hall holds the tables, the cue racks, the chalk and the scoreboards, and a frame can run long into the evening, so its leaf takes FD30 and stays shut while members are at the tables.
The hall leaf carries a small vision panel, so a member can see whether a table is free without opening the leaf and breaking the quiet of the hall. The fire door vision panels guide names what a pane in a fire leaf must hold.
A route that serves more than 60 people needs a leaf that opens under a crowd, so the leaves on it carry a push bar proved to BS EN 1125, and the bar spans no less than 60 percent of the leaf width. A member pressed forward by the crowd behind them opens the leaf with a single push, and the bar answers whether the supply is on or off. The panic hardware guide names what the bar must do when a crowd presses against the leaf, and the emergency exit doors guide covers the leaves on the way out.
Members sit in the members room between frames, with armchairs, a notice board and the league tables on the wall, so the leaf takes FD30 and stays shut while the room is empty.
Smoke in the club: Sa and S200 beside the period
Smoke reaches the hall before flame does, so the leaf needs a smoke seal beside its period, and the seal is proved to BS EN 1634-3. A leaf marked Sa holds smoke back at room temperature, and a leaf marked S200 holds it back at 200 degrees, so the mark on the order names which smoke the leaf was proved against.
The corridor from the hall to the entrance carries the smoke of a fire in the kitchen or the plant room, so the leaves on that corridor take smoke seals with their period. The smoke control doors guide names where a smoke seal sits beside a fire period.
Closers, seals and gaps: what the club period rests on
The closer that draws the leaf shut after each member carries a proof to BS EN 1154, where EN 1 is the smallest power size the standard names and no fire leaf takes a power size below EN 3. A closer that is too weak for the leaf leaves it ajar, and a leaf left ajar holds no period at all.
The intumescent seal round the leaf swells when the heat reaches it, and the swell closes the gap round the leaf edge. The seal starts to expand at around 200 to 250 degrees, and the intumescent seals guide names how the seal is fitted and what it must hold.
The gap round a fire leaf is 4 mm, and the gap is measured round the leaf edge and the head, not guessed by eye. The fire door gaps guide names where the gap is measured and what a wide gap costs the leaf.
Hinges proved to BS EN 1935 carry the club leaves, grade 13 through 200,000 cycles with a leaf of 120 kg and grade 14 through the same cycles with a leaf of 160 kg. The fire door hardware guide names what each piece on a fire leaf must carry.
The snooker club fire door order: every leaf, its period and its proof
The whole order sits on one list, with a line for every opening that names the leaf, the period, the seals and the closer beside it. A leaf with no line of its own may end up hung where it does not belong, and an FD60 leaf on the members room would hold for 60 minutes where 30 would do.
The club secretary takes the door list round the club each month and tries each leaf in turn, and the closer, the seals and the gap on each leaf are looked at as the leaf is tried. A leaf that will not shut, a seal that is torn and a gap that has grown are noted on the list, and the fire door inspection checklist names what the walk round the club should cover.
The larger sports hall beside a club is covered in the fire door regulations for leisure centres guide, and the fire compartmentation guide names how the rooms of the club are held apart from each other. The fire door maintenance guide names what keeps a leaf holding its period after the order.
Before the order is signed, each leaf on it is read through once more, and the proof for every leaf is checked against the list before the order leaves the club.
The period on a snooker club leaf follows the room behind it, so the leaf, the closer and the seals are ordered together and checked together against the tables and the takings behind the leaf.
What period does a snooker club entrance take?
FD30 to EN 1634-1, which holds flame back for 30 minutes, because the entrance stands on the way out through the evening.
What period does the kitchen take?
FD60 to EN 1634-1, which holds flame back for 60 minutes, because the cookers behind the leaf ask for a longer hold than the rooms at the front.
What period does the plant room take?
FD60 to EN 1634-1, which holds flame back for 60 minutes, because the boards behind the leaf feed the whole club.
What gap does a fire door leaf need?
A gap of 4 mm round the leaf edge and the head, because a wider gap lets flame and smoke past the leaf before the period runs out.
Who checks the snooker club fire doors?
The club secretary checks the fire leaves each month, with the closer, the seals and the gap on each leaf looked at as the leaf is tried.
Get a free quote
Related
More in guides for specifiers
Products
One supplier for the whole building envelope
Ready to specify your project?
Free assessment, written specification and test evidence. Reply within one working day.