ArxBridge
Hospice Security Doors Explained
A hospice welcomes visitors through the night and keeps controlled drugs behind its leaves, so each door takes the LPS 1175 grade that its room demands.
- ✓Third-party test evidence with every product
- ✓Written specification you can issue to tender
- ✓Supplied and installed across the UK
Get a free project quote
Rating, written specification and budget range within one working day.
Confidential. No cost, no obligation.
Third-party tested
Evidence with every quote
UK manufactured
Made to your sizes
One accountable team
Specify, supply, install
Confidential handling
Details never shared
A hospice gives end-of-life care where visitors arrive at all hours and controlled drugs sit in a locked store, and its doors draw a line between public rooms and rooms only staff may open. The entrance takes families in at any hour, the reception leaf stands between the families and the corridors where care happens, and the drugs store, the staff office and the plant room sit behind leaves the public never passes.
LPS 1175 Issue 8.2, dated September 2024, sorts a leaf by the minutes it stands against the tools the test names, and a hospice leaf takes its grade from what waits behind it. Three minutes is the hold B3 gives, five minutes the hold C5 gives and ten minutes the hold D10 gives, and an older drawing may still name the same leaves SR2, SR3 and SR4.
A hospice is not a care home, because the people inside are near the end of life and the building stays open to their families through the night, and it is not a hospital, because the wards are bedrooms and the corridors are quiet. The fire door regulations care homes guide covers the fire rules for a home where residents live for years, while the leaves in a hospice follow the visiting hours, the drugs store and the quiet rooms.
- B3 / C5 / D10Grades to LPS 1175 Issue 8.2
- Drugs storeWhere D10 sits
- Visiting hoursFamilies arrive at all hours
- One listEvery hospice leaf named
Five rooms in a hospice: the grade each one carries
Five rooms make up the hospice order, and the grade follows what each room holds. The entrance takes the families in, the reception leaf stands where they are met, the drugs store holds the controlled drugs, the staff office holds the keys and the rotas, and the plant room keeps the building warm and lit.
B3 goes on the entrance leaf and on the reception leaf, because families pass both leaves at every hour and staff at the desk can see them. The staff office and the plant room take C5, because what sits behind them asks for five minutes rather than three. The drugs store takes D10, because controlled drugs are the most portable thing the hospice holds, and the leaf stays shut and locked when no one is drawing up a dose.
One line on the order names each opening, the leaf that hangs in it and the grade the leaf must hold, so the fitter checks each leaf against its own line while it is hung. The table below sets the five rooms beside their grades, so each leaf can be checked as it arrives.
| Room | Grade | Minutes | What to check |
|---|---|---|---|
| Entrance | B3 | 3 | Leaf, lock, closer |
| Reception | B3 | 3 | Leaf, lock, seals |
| Drugs store | D10 | 10 | Leaf, lock, hinges |
| Staff office | C5 | 5 | Leaf, lock, reader |
| Plant room | C5 | 5 | Leaf, lock, seals |
The fire minutes run from 30 to 120 under EN 1634-1, with E for flames alone, EW for flames with part of the heat held back and EI for flames with the heat held back as well, and the forced entry grade beside them comes from LPS 1175 Issue 8.2 of September 2024. The fire and security doors dual certification guide shows how the two proofs sit in one report for the same leaf, the LPS 1175 Issue 8 explained guide sets out what Issue 8.2 changed, and the SR2 vs SR3 vs SR4 guide puts the old names beside the new grades.
The entrance leaf: visitors in at all hours, strangers out after dark
Families arrive at the hospice at hours when most buildings are shut, and the entrance leaf is the first thing they meet, so it must open for a visitor with hands full and shut behind them. A glazed panel in the leaf lets reception see who is standing outside before the leaf opens, and the panel is proved with the leaf round it, with the glass, the bead and the fixings named together in the same report.
The entrance asks for three minutes because it stands in sight of the reception desk through every hour, and three minutes gives the staff time to shut the reception leaf and raise help. A key works the lock from the street and a thumb turn works it from inside, so the last person to leave at night secures the leaf with a turn of the thumb and the first person in opens it with the key.
A door entry panel beside the entrance lets reception speak to a visitor before the leaf is opened, so a stranger after dark is met through the panel first. The door entry systems guide covers the panels and the readers that guard an entrance, and the hospital security doors guide shows how a building that takes visitors through the night grades the leaves round its wards.
Bedroom doors: privacy for the person inside, access for the nurse
A hospice bedroom is where a person spends their last days, so the leaf on it must give privacy when shut and let a nurse in at once. The lock takes a thumb turn on the bedroom side, so the person inside can shut the leaf without a key, and a key on the corridor side, so staff can open it from the corridor.
A small glazed panel in the bedroom leaf lets a nurse look in without opening the leaf and waking the person inside, and the panel sits high, so the bed stays out of sight. The anti ligature doors guide covers the leaves for rooms where a person may harm themselves, and that detail is not repeated here, while the fire door regulations care homes guide covers the bedroom leaf a care home fits, and the fire door vision panels guide covers the panels a leaf may carry.
The drugs store takes D10 behind a shut steel leaf
The drugs store holds the controlled drugs the hospice gives through the day and the night, so its leaf takes D10, the longest hold LPS 1175 Issue 8.2 names. The leaf, the frame, the fixings and the lock are proved as one doorset, and the report beside that doorset names ten minutes against the tools the test names.
Glass has no place on the drugs store leaf, because a pane would let the corridor see the drugs being drawn up and give a hand a way to the lock, so the leaf is solid steel. A D10 leaf is heavy, and its weight hangs on hinges proved to BS EN 1935, where grade 13 carries a leaf of 120 kg and grade 14 a leaf of 160 kg, each through 200,000 cycles, so the bolt keeps finding its keep year after year.
Under TS 007, a cylinder rated 1 star and a handle rated 2 star combine into a 3 star set, and the pair is ordered together so the cylinder on the drugs store leaf is the one the test saw beside its handle. The nurse in charge holds the key to the drugs store, and the names that may open it sit on the list beside the leaf, so a leaf left standing open is shut at once. The security doors for pharmacies guide shows the same leaf in a pharmacy, and the security doors for GP surgeries guide shows it in a surgery.
Quiet rooms and the family room: leaves that shut without a sound
A quiet room is where a family sits with the person they love, and the leaf on it must shut without a sound. The closer on a quiet room leaf brings the leaf home slowly, so the latch meets its keep without a click, and the leaf is shut whenever the room is in use, because an open leaf lets words out into the corridor.
The family room is where relatives wait through the night, make tea and rest between visits, so its leaf stands open through much of the day and shuts only when the family inside asks for quiet. A hold-open device proved to BS EN 1155 holds the family room leaf open through the day and lets it shut on its own when the alarm sounds, so the leaf is never wedged.
Staff office and plant room: keys, records and services behind C5
The staff office holds the keys to the other rooms and the papers that record each person in care, so its leaf takes C5 and stays locked whenever the room stands empty, because an open room gives a passer by the keys to the rest of the hospice. A reader beside the staff office leaf opens only for the cards the list names, so the room opens for the staff and stays shut for the public.
Boards and equipment in the plant room keep the lights, the heating and the call system running, so the leaf on that room takes C5, because a stranger through it reaches the boards that feed the whole hospice. The plant room door requirements guide covers the leaves of a plant room in full, and the security door locks guide names the lock that each leaf in the hospice must carry.
Keys, cards and the night routine: who opens which leaf after dark
After dark a small night team staffs the hospice, and each leaf opens to the cards and keys of the staff on duty, while no card held on the public side opens any of them. The master key systems guide shows how one plan gives each holder the rooms their own work needs and no other room, and the security door locks guide names the lock each leaf in that plan must carry.
The nurse in charge holds a key that opens every leaf in the clinical corridors, and the night staff hold keys that open only the rooms their round takes them to. The 10 steps to specify an LPS 1175 door guide takes the order from the first leaf to the last.
The hospice order: every leaf, its grade and its lock
One list carries the whole hospice order, with a line for every opening that names the leaf, the grade, the lock and the closer beside it. A leaf with no line of its own may be hung where it does not belong, and a C5 leaf on the drugs store holds for five minutes where ten is asked for.
Each month the hospice manager takes the door list round the building and tries the leaves in turn. A leaf that drags, a bolt that misses its keep and a closer that leaves the leaf standing open are each written against their own door on the day they are found, and the security door maintenance checklist names what the walk should cover.
The steel door frames guide sets out how the frame holds the leaf and the lock together, and the keeping an LPS 1175 rating valid guide names what can take a rating away once the leaf is hung.
The grade on a hospice leaf follows what waits behind it, so the leaf, the lock and the closer are ordered together and checked together against the room behind the leaf.
What grade should a hospice entrance door carry?
B3 to LPS 1175 Issue 8.2, which holds for three minutes, because the entrance stands in view of the reception desk through day and night.
What grade should a hospice drugs store door carry?
D10 to LPS 1175 Issue 8.2, which holds for ten minutes, because the drugs store holds the controlled drugs behind a shut leaf.
What grade should a hospice reception door carry?
B3 to LPS 1175 Issue 8.2, because the reception leaf is watched by the staff at the desk day and night, and three minutes is the hold a watched leaf asks for.
Can one leaf hold fire and forced entry?
Yes, where one doorset passed both the fire test and the forced entry test, so its period and its grade sit in the same report beside the same leaf.
Who checks the hospice doors?
The hospice manager walks the building with the door list each month and tries the leaves in turn, so a fault is found and put right before the leaf is asked to hold.
Get a free quote
Related
More in guides for specifiers
Products
One supplier for the whole building envelope
Ready to specify your project?
Free assessment, written specification and test evidence. Reply within one working day.