ArxBridge
Automatic Vehicle Barriers
Automatic vehicle barriers: barrier arms for car parks and entrances, with cycle time, access control, safety devices, fail position and one schedule.
- ✓Third-party test evidence with every product
- ✓Written specification you can issue to tender
- ✓Supplied and installed across the UK
Get a free project quote
Rating, written specification and budget range within one working day.
Confidential. No cost, no obligation.
Third-party tested
Evidence with every quote
UK manufactured
Made to your sizes
One accountable team
Specify, supply, install
Confidential handling
Details never shared
An automatic vehicle barrier rises for a vehicle the site expects and stays down for the rest. It gives a car park or an entrance the control of a gate with the speed of an arm, and it suits a lane where vehicles must pass one at a time and be checked as they do.
The order starts with the lane, not with the barrier. A staff car park that fills in the morning asks for a different arm from a site entrance where lorries arrive through the day, and a lane that must pass a vehicle every few seconds asks for a different drive from a lane that opens a few times an hour.
The arm, the drive, the access control and the safety devices all sit inside one schedule, and an order that names each one plainly gets the right barrier on the right lane. The gate lines that share the boundary are covered in our security gates page, and how a powered gate is driven is covered in our gate automation guide.
- BS EN 12453Safety in use of power operated doors
- ISO 22343-1Vehicle security barrier ratings
- 1,200 mm / 500 mmProtectUK gap cap and height floor
- Loop, photocell, edgeThe three safety devices on the lane
Where an automatic barrier earns its place: car parks, entrances and the lane in
A staff car park is where most automatic barriers stand, across the lane in, where the arm rises for a card the site knows and stays down for the rest. The barrier keeps the spaces for the staff who belong there, and the record shows who entered and when.
A site entrance takes the same barrier in a longer lane, where lorries and visitors arrive through the day and must be checked before they pass. The barrier holds each vehicle at the gate while the check runs, so the site knows what is inside before the vehicle reaches the yard.
A transport hub takes a barrier where vehicles and people cross the same ground, and the lane must keep them apart. The barrier holds the vehicles on their lane while the pedestrians use theirs, and the hubs that run that mix are covered in the transport hubs sector page, while the gates that run beside the barrier are covered in our sliding vehicle gates page.
Barrier arms, rising bollards and gates: the control that fits the entrance
A barrier arm suits a lane where vehicles must pass fast and be checked as they do. The arm rises in seconds and drops behind the vehicle, so the lane keeps moving, and it asks for little ground work beside the housing, so it suits a car park lane where the queue must not grow.
A rising bollard suits a lane where a vehicle must be stopped, not only checked. The bollard rises from the road and stands in the way of a vehicle that tries to drive through, so it suits an entrance where the threat is a vehicle that will not stop, and the powered type is covered in our rising bollards page.
A gate suits a lane where the line must close fully, with no gap a vehicle can use. The gate closes the whole opening, so it suits a boundary where the site must stay shut at night, and the fixed bollards that close the gaps beside it are covered in our security bollards page, while the rated options for the gate line are covered in our anti-ram gates and barriers guide.
Cycle time and throughput: how many vehicles the lane must pass
The cycle time decides how many vehicles the lane can pass in an hour. An arm that rises and drops in a few seconds keeps a staff car park moving in the morning, while an arm that takes longer leaves a queue on the road outside, so the cycle time belongs on the order beside the lane.
Throughput follows the peak, not the average. A lane that passes ten vehicles an hour through the day and a hundred in the morning must be proved for the morning, so the peak count belongs on the order, and the drive must be proved for that duty, because a drive that overheats at the peak leaves the lane shut when the site needs it open.
The access control sets the real speed of the lane, because a reader that takes seconds to answer slows every vehicle behind it. The reader, the fob and the plate check each add their own time, so the whole check belongs on the order with the arm, and what each step up the line adds to the build is worked through in our security gates cost factors guide.
Peak hour on the lane: passing vehicles while one lane stands shut
The lane earns its keep at peak hour, when the morning flow arrives all at once and the queue forms on the road outside. When one lane stands shut for repair, the lane that stays open must carry the whole flow, so the drive on the open lane is proved for the peak, not for the average hour. The reader, the loop and the photocell on the open lane each take the extra work too, and a slow reader at peak hour holds every vehicle behind it, so the reader time belongs on the order beside the arm. A lane that must stop a vehicle outright takes a blocker rather than an arm, and the road blockers guide covers the type that rises from the road.
Closing a lane for repair starts with the vehicles, not with the barrier. The shut lane is marked off before the work starts, the vehicles are sent to the lane that stays open, and the open lane is watched through the first peak after the change, because a lane that copes at midday can still fail at eight in the morning. A drive that runs hot at the peak will stop when the queue is longest, so the order names the peak count beside the cycle time. The gate automation guide names the drive behind a powered barrier. Readers, fobs and biometrics are named in the security turnstiles guide, with the lane they serve beside them.
| Lane state | What the lane carries | What the order names |
|---|---|---|
| Both lanes open | The flow split between two lanes | Cycle time, reader time and drive duty |
| One lane shut | The whole flow on one lane | Peak count and drive proved for the peak |
| Repair under way | No vehicles while work runs | Fail position, manual release and marking |
| Lane back in use | The flow shared by two lanes again | Loop, photocell and edge tested again |
One lane down for repair: the shift the other lane must carry
A repair that shuts a lane is planned for the quiet hour, and the lane comes back before the next peak, because a lane shut at eight in the morning is a queue on the road outside. The service contract is what keeps the open lane running while the shut lane is repaired, and it names the parts the site holds and how fast a repair crew reaches the site, because a lane with no spare arm stays shut till the part arrives. The arm that comes back is proved with its safety devices before the lane opens again, and the loop, the photocell and the edge are checked with the arm, because each device watches a different danger.
Write the repair plan onto the schedule beside the barrier, with the lane, the drive and the safety devices on the same line, so the barrier that comes back is the barrier that was proved. The sliding vehicle gates page names the gates that run beside a fence. The anti-ram gates and barriers guide weighs the options for the gate line, and the security gates cost factors guide shows what each step up the line adds.
The second vehicle behind the first: tailgating on a barrier lane
A barrier arm that rises for one vehicle and drops behind it can still let a second vehicle through, because the second vehicle follows the first through the lane before the arm comes down. Tailgating is the gap the lane leaves open after the check has run, and the arm timing, the loop in the floor and the photocell across the lane are what close it. The loop holds the arm up while a vehicle waits underneath, and the photocell stops the arm before it meets anything, so each device watches a different danger, and a lane without all three has a gap in its safety.
The arm must come down fast enough that the second vehicle cannot follow, and the drive must be proved for the peak the lane carries, because a drive that overheats at the peak leaves the lane shut when the site needs it open. Throughput follows the peak, not the average: a lane that passes ten vehicles an hour through the day and a hundred in the morning must be proved for the morning, so the peak count belongs on the order beside the cycle time. The readers, fobs and biometrics in the lane are named in the security turnstiles guide, and the drive behind a powered barrier is named in the gate automation guide.
| Tailgate risk | What stops it | What the order names |
|---|---|---|
| Second vehicle follows | Fast arm, loop, photocell | Cycle time, loop, photocell |
| Arm too slow | Drive proved for the peak | Peak count, drive duty |
| Reader too slow | Reader that answers fast | Reader time, plate check time |
| Lane left open | Arm drops behind each vehicle | Drop time, fail position |
Spares on the quote keep the lane moving when a part wears out
A barrier lane that opens and shuts many times a day wears the drive, the arm and the loop, and the service contract is what keeps the lane moving when a part wears out. The contract should name the drive, the arm, the loop, the photocell and the safety edge, with the spares the site holds and the time a repair takes, because a lane with no spare arm is a lane shut while the part is ordered. The inspection round looks at every barrier, loop and photocell in turn, and each fault is written down the same day, with the barrier and the fault beside it.
Read two quotes side by side and check that each one names the same arm, the same motor and the same safety devices. A quote that leaves the safety edge off the list has not cut the cost, it has only pushed it to the day the barrier is fitted, and a quote that leaves the service contract off the list leaves the lane with no one to call when the drive fails. The gates that run along a fence line are named on the sliding vehicle gates page, the options for the gate line are weighed in the anti-ram gates and barriers guide, the cost of each step up the line is shown in the security gates cost factors guide, and the blockers that lift out of the road are named in the road blockers guide.
Access control on the lane: readers, ANPR and the intercom
Access control on a barrier lane decides who can raise the arm, and when. Staff take a card or a fob for the lanes they use every day, and a fob can be stopped when staff leave, because a fob costs nothing to stop and a key costs a new one.
ANPR reads the plate as the vehicle approaches, and the arm rises for a plate the site knows. The camera must read the plate in the rain and in the dark, so the camera and the light beside it belong on the order with the barrier, and the plates that may pass belong on the list the site keeps.
Visitors take the intercom, and a voice at the gate lets them ask to be let in. The intercom should reach the person who can open the lane, and the lane should hold the vehicle while the check runs, so no visitor waits on the road. Readers, fobs and biometrics in the lane are covered in our security turnstiles guide, and how a powered barrier is driven is covered in our gate automation guide.
Safety devices and the loop: what stops the arm coming down
A barrier arm is a machine, and BS EN 12453 sets out how it must be made safe to use. Loops in the road, photocells across the lane and a safety edge on the arm each stop the arm coming down on a vehicle or a person, and a lane without them has no proven safety at all.
The loop in the floor holds the arm up while a vehicle waits underneath, and the photocell stops the arm before it meets anything. Each device watches a different danger, so a lane without all three has a gap in its safety, and the rules the line must meet are set out in our bollard regulations guide.
Prove the safety devices with the barrier, as one assembly, rather than fitting them after the barrier is in the ground. A loop blind to a vehicle, a photocell set too low or an edge that does not reach the arm each leaves the lane unsafe, so the devices belong on the test report with the barrier. The blockers that rise from the road are covered in our road blockers guide, and the ratings in full are in our ISO 22343 vehicle security barriers guide.
Power loss and the fail position: what the barrier does when the power goes
When the power goes, the barrier must fail in the position the site needs, and the position is named on the schedule before the order is placed. An arm that stays down traps vehicles inside, and an arm that rises lets them through, so the site decides which failure it can live with.
The manual release must work on power failure as well as on alarm, and it must be written into the order beside the motor. A release that needs power to work is no release at all, so the release is checked on the inspection round, and the checks each round should make are set out in our security door maintenance checklist.
A barrier that must stay shut on power loss needs a lock that holds it there, and a barrier that must open needs a release that frees it. The choice belongs on the schedule, because a barrier fitted with the wrong fail position leaves the site open or shut at the worst time, and the ratings behind the line are set out on our vehicle impact ratings page.
The arm, the housing and the ground it stands in
The housing holds the drive, and it must stand on a foundation that keeps it true. A housing set in a shallow foundation rocks under the arm, so the depth, the concrete and the fixings belong on the schedule beside the barrier, and the foundation must not cut through the services under the lane.
The arm must take the wind the site sees, because a long arm on an exposed site takes more wind than a short arm in a sheltered yard. The arm should be chosen for the gusts the site sees, not for the calm days between them, and the bollards that stand beside it are covered in our PAS 68 bollards guide, while the options for the line are worked through in our choosing HVM bollards guide.
Drainage decides how long a barrier lasts. A housing that holds water corrodes the drive from below, so the drain beside the housing belongs on the schedule, and the inspection round should look for the housing that no longer drains. The line that hides its protection in street furniture is covered in our HVM planters and street furniture guide, and the line that must stop a vehicle is covered in our hostile vehicle mitigation page.
The barrier order: one schedule for the whole entrance
Write the enquiry as one schedule with a line for every barrier on the site, and put the position, the arm length, the drive, the access control, the safety devices and the fail position on each line, so the barrier that arrives is the barrier that was proved.
Keep the test report, the rating and the service schedule with the barrier from the day it arrives, and write the inspection routine into the handover pack, so the next team can see what was proved and what must be checked. The columns such a schedule needs are set out in our how to specify security doors guide, and what each step up the scale adds to the build is worked through in our bollard cost factors guide.
| Position | Barrier | Control | What to check |
|---|---|---|---|
| Staff car park | Barrier arm | Card reader | Cycle time, loops, release |
| Site entrance | Barrier arm | ANPR | Camera, light, intercom |
| Visitor lane | Barrier arm | Intercom | Photocells, edge, housing |
| Goods yard | Rising bollards | Fob | Rating, pit, drainage |
| Boundary gate | Sliding gate | Card reader | Rating, gaps, release |
An automatic barrier opens the lane for the vehicles the site expects and closes it to the rest, so the arm, the drive, the access control and the safety devices must all sit on the same schedule.
What is an automatic vehicle barrier?
A barrier arm that rises for a vehicle the site expects and stays down for the rest. It gives a car park or an entrance the control of a gate with the speed of an arm.
Barrier arm or rising bollard: which fits?
The threat decides. An arm suits a lane where vehicles must pass fast and be checked as they do, and a rising bollard suits a lane where a vehicle must be stopped, not only checked.
What safety devices does a barrier lane need?
BS EN 12453 sets out the safety in use of power operated doors, and loops, photocells and safety edges each stop the arm coming down on a vehicle or a person in its way.
What happens to a barrier in a power cut?
It must fail in the position the site needs, and the position is named on the schedule before the order is placed. An arm that stays down traps vehicles inside, and an arm that rises lets them through.
Who checks automatic vehicle barriers?
The team that runs the site, on the routine the maintenance plan sets. Each record names the barrier, the fault, the repair and the date it was fixed.
To get one quote for every opening, use the security door enquiry checklist and send the list in one go.
Get a free quote
Related
More in guides for specifiers
Products
One supplier for the whole building envelope
Ready to specify your project?
Free assessment, written specification and test evidence. Reply within one working day.