Window Security Bars
Window security bars for shops and offices: fixed, hinged and removable bars, LPS 1175 ratings, fixings that hold, and bars that still let people out.
- ✓Third-party test evidence with every product
- ✓Written specification you can issue to tender
- ✓Supplied and installed across the UK
Get a free project quote
Rating, written specification and budget range within one working day.
Confidential. No cost, no obligation.
Third-party tested
Evidence with every quote
UK manufactured
Made to your sizes
One accountable team
Specify, supply, install
Confidential handling
Details never shared
A window beside a door is the weak point of a frontage. A door proved to LPS 1175 can still be reached through the glass beside it, because the pane beside the leaf is the way in when the leaf itself will not move. Bars guard the glass while light still comes through, so the window keeps its job and gains a rating.
The bar must be proved with the window, not added to it afterwards. A bar fixed to a weak frame fails at the frame, and a bar on a pane that was never proved with it leaves the frontage different from the one tested. The bar, the frame, the fixings and the glass belong on the same line of the order.
The glass that shares the wall is set out in the fire rated windows guide, and the LPS 1175 windows and walling guide covers the ratings a window and its wall can carry. The types of security doors guide works through the doors that guard each part of a building.
- LPS 1175 B3 / C5 / D10Forced entry periods to LPS 1175
- EN 1627 RC1 to RC6Resistance classes for windows
- Fixed / hinged / removableThe bar that fits the room
- Steel grade and finishNamed on the order beside the bar
The bar that guards the glass: what window bars must do
A window bar stands across the opening and takes the attack that would otherwise reach the glass. The bars sit close enough together that a person cannot pass between them, and the bar itself must resist the tools that the rating names. A bar that bends under a lever opens the way to the pane behind it.
The rating on the order follows the room the window guards. Forced entry is proved to LPS 1175, with B3 holding three minutes, C5 holding five minutes and D10 holding ten minutes, each against the tool set for its category, all under Issue 8.2, dated September 2024. The window that guards a room holding cash takes a higher grade than the window that guards a store.
Light must still come through, because a window that is barred shut like a wall is no window. The spacing of the bars decides how much light reaches the room, and the finish decides how the bars read from the street.
Fixed, hinged and removable: the bar that fits the room
A fixed bar suits a window that never opens. The bar is fixed to the frame on both sides, and it stays where it was fitted, so the window behind it is guarded every hour of the day. A store window and a back room window take fixed bars, because no one behind them needs the window to open.
A hinged bar suits a window that must open for cleaning, for air or for escape. The bar swings on its hinges and locks shut, and the lock on the bar must be the lock the order names, because a bar that can be opened from outside is no bar. The hinge and the lock belong on the order beside the bar.
A removable bar suits a window that needs the bar off for part of the day, such as a window behind a counter that is staffed through the day. The bar lifts out of its fixings and locks back in, and the fixings must hold the bar as firmly as a fixed bar when it is in place. The security windows for schools guide covers the windows on a site where the rooms change use through the day.
Reading the rating: LPS 1175, EN 1627 and the attack a bar must take
Two ratings can sit on a window bar, and the order must name the one the bar was proved to. LPS 1175 proves the bar against the tool set for its category, with B3, C5 and D10 holding three, five and ten minutes. EN 1627 proves windows and doors against attack in classes RC1 to RC6, with each class naming the tools and the time the assembly must resist.
The class on the order follows the risk behind the window, not the size of the pane. A ground floor window on a shop takes a higher class than a first floor window on an office, because the ground floor is the floor an intruder reaches first. A bar ordered without a rating leaves the fitter to guess, and a guess is not a proof.
The rating belongs to the assembly, not to the bar alone. The bar, the frame, the fixings and the glass were proved together, and a bar swapped for another after the test leaves the window different from the one tested. The LPS 1175 versus EN 1627 guide works through the two ratings side by side, and the fire rated windows cost factors guide covers the windows that share the same wall.
The frame, the fixings and the wall: the parts that hold a bar
A bar is only as strong as the fixings that hold it. Fixings into masonry, into steel and into timber each take a different anchor, and the anchor must suit the wall behind the window. A bar fixed with the wrong anchor will pull out of the wall before the bar itself bends.
The frame must carry the bar without twisting, because a frame that twists lets the bar move in its fixings. The frame, the fixings and the surrounding wall belong on the order with the bar, so the assembly that arrives is the assembly that was proved. The steel versus aluminium security doors guide works through the choice between frame materials.
The wall behind the window matters as much as the window itself. A bar on a strong window in a weak wall guards nothing, because the attack moves to the wall beside the frame. The LPS 1175 windows and walling guide covers the walling that shares the proof, and the fire rated glass cost guide works through what each step up the scale adds to the price.
A bar can look strong and still come away in the hand. The steel is sound, the welds hold, and the bar itself would stop anyone who tried it, yet one pull takes it out of the wall because the fixing behind it has worked loose. The bar never failed. The wall failed, and the bar only showed it. The strength of a bar sits in the fixing behind it, and the strength of the fixing sits in the wall it is set in.
The bar holds; the wall gives way
Old brick crumbles round a fixing a little at a time. Each tug on the bar, each knock against it, each year of weather on the face of the wall loosens the anchor a fraction, and the anchor that once sat tight now turns in a hole wider than the fixing that went into it. A bar fixed to such a wall looks right from the room and gives way at the first hard pull.
The test is a pull, not a look. The round takes each bar in both hands and pulls it hard, feeling for movement at the fixing and watching for dust falling from the hole. A bar that moves is written down the same day, and the fixing is not tightened back into the same worn hole. The wall the bar sits in is checked as part of the bar; LPS 1175 windows and walling guide deals with walling that carries the same proof.
Soft mortar gives way faster than brick. A fixing set in mortar that has turned to dust holds nothing, and a screw in such a joint turns without biting. The rating on the bar means nothing when the wall behind it cannot hold the fixing; LPS 1175 versus EN 1627 guide compares the two ratings.
A fixing that has been pulled out once leaves a hole that will not hold a second fixing, so the new fixing goes into sound material beside the old hole, not into the hole the old one left.
A loose anchor in old brick leaves the bar strong to look at and weak to pull
Timber frames dry and shrink, and the gap that opens beside the frame lets the fixing move. A bar on a timber frame is checked at the frame as well as at the wall, because the frame is the part the bar is fixed to and the wall is the part the frame is fixed to. The doors beside the window follow the same rule as the window itself, and the emergency exit doors guide deals with doors that open from inside with no key and no card.
A room where more than sixty people gather takes a bar that opens at one push, and the panic hardware guide deals with that bar, while the security windows for schools guide follows windows in rooms that serve one use in the morning and another at night.
| Fixing | Wall it sits in | Sign it has worked loose |
|---|---|---|
| Anchor | Old brick | Bar moves when pulled |
| Screw | Soft mortar | Head turns without biting |
| Frame fixing | Timber that has dried | Gap opens beside the frame |
Send the window list with the fixings and the wall beside each one, and the security door enquiry checklist needs every window on it to carry its bar, its rating and its wall.
Bars on the escape route: the window that must still open
A window on an escape route must still open when the alarm sounds, even where it carries bars. The bar on such a window releases from the inside, without a key, a code or a card, so the person behind it can open the window with one action. A bar that needs a key to release traps the people behind it.
The release on the bar is tested on the round, by opening the bar from inside and watching the window open behind it. A release that has seized shut through damp or rust is a fault, and the fault is written against the window it belongs to on the same day. The fire door regulations commercial buildings guide sets out the periods for the shared parts of a public building.
Smoke reaches people before the flames do, so a window that lets smoke out must open freely, and the bar on it must not slow the hand that opens it. The smoke control doors guide covers the doors that hold smoke back, and the force to open a door on the route must stay below 30 N for the first 30 degrees of travel and below 22.5 N beyond, under BS 8300 and Approved Document M.
A bar on an escape window has two jobs that pull against each other. It must hold an intruder out, and it must let the person inside out, and the release that does the second job is the part that decides whether the window is still an escape.
One pull from inside must free the bar, even when the room is full of smoke
The release sits on the inside, where the person behind the window can reach it with one hand and no key. One pull frees the bar and the window opens behind it, because a release that needs two hands, or a key kept in another room, is a release that fails on the night it matters.
Smoke fills a room before the flames reach it, so the window must open while the person at it can barely see. The release must work by feel, in the dark, with one hand, and the bar must swing clear of the opening without catching on the frame.
A door on the escape route opens from inside without a credential, and the emergency exit doors guide sets out the same rule for the doors beside the window.
Panic hardware gives the door a bar across the leaf that one push opens, and the panic hardware guide names the bar that fits a room where more than sixty people gather.
A release that has seized shut is a window that has stopped being an escape
Every round tries the release from inside and watches the bar swing clear. A release that sticks, grates or will not move at all is written against that window the same day, because a release that is left to seize is a window that will not open when the alarm sounds.
The hinges and the lock are checked with the release, because a bar that swings on worn hinges will not sit true, and a lock that has rusted shut holds the bar closed as firmly as a bar that was never meant to open.
Glass, frame, fixings and bar were tested as one assembly, so a bar changed after the test leaves the window unlike the one that was proved. The LPS 1175 windows and walling guide names the walling that carries the same proof, and the LPS 1175 versus EN 1627 guide puts the two ratings side by side.
Rooms that change use through the day need a bar that fits the hour, and the security windows for schools guide follows the windows on a site where one room is a classroom in the morning and a hall at night.
| Window | Bar | Release check |
|---|---|---|
| Escape window | Hinged bar | Opens from inside with one pull |
| Store window | Fixed bar | No release, checked for fixings |
| Ground floor office | Hinged bar | Release, hinges and lock |
Send the window list for the security door enquiry checklist with the order, so every window on the schedule carries its bar, its rating and its release, and the window that must open still opens.
Shops, offices and the rooms that hold cash: where bars go first
Bars go first on the windows an intruder reaches first. Ground floor windows on a shop front take bars before any other window on the building, because the street is the way in and the glass is the weak point.
Rooms that hold cash, stock or records take bars on every window, whatever the floor. A cash office, a stock room and a server room each hold something worth taking, and the window behind each of them needs the same grade as the door beside it. The bank security doors guide works through the doors that guard cash and valuables, and the school security doors guide covers the doors on a site where keys change hands often.
Offices take bars on the windows that face the car park and the yard, where no one watches through the night. A window that faces a quiet side of the building needs the bar more than a window that faces a busy street, because the attack happens where no one is looking. The fire door regulations retail guide sets out the periods for the shared parts of a shop.
Bars beside the doors: one frontage, one schedule
Bars and doors share the frontage, so they share the schedule. A frontage where the door carries B3 and the window beside it carries nothing is a frontage with a hole in it, because the attack moves to the weakest part. The bar and the door beside it should carry the same grade, so the frontage holds as one.
The finish on the bars should match the doors beside them, because a frontage that reads as one piece is a frontage that was planned as one. The grade of steel and the finish belong on the order beside the bar, with the rating named beside them.
The schedule names every window on the frontage, with the bar, the rating and the fixings beside each one. The how to specify security doors guide sets out the columns the schedule needs, and the security door cost factors guide works through what each step up the scale adds to the price.
One schedule for the whole frontage: every bar on one line
Put the bar order together as one list, with a line for every window on the frontage and the bar, the rating, the fixings and the finish beside each one, so the bar that arrives matches the bar that was proved. A schedule that names one bar for the whole frontage leaves the fitter to guess which window takes which fixing, and a guess is not a proof.
Read the quotation beside the schedule before the order goes out, and mark each bar, fixing and finish as it is priced, so nothing is left off. A bar left off the price still has to be bought, and fitting it to a window that is already in place costs more than ordering it with the window.
The round that looks after window bars walks the frontage in turn and looks at the bars, the fixings, the locks and the glazing. Each fault is written against the window it belongs to on the same day, with the part and the date beside it, so the repair follows the fault and the frontage never stands open. The security door maintenance checklist names the checks that keep a doorset honest through its life.
| Position | Bar | Proof | What to check |
|---|---|---|---|
| Shop front | Fixed bar | LPS 1175 B3 | Bars, fixings, frame |
| Cash office | Fixed bar | LPS 1175 C5 | Bars, fixings, lock |
| Ground floor office | Hinged bar | LPS 1175 B3 | Hinges, lock, fixings |
| Escape window | Hinged bar | Release inside | Release, hinges, gap |
| Store | Fixed bar | LPS 1175 B3 | Bars, fixings, finish |
A bar holds only as long as the frame, the fixings and the proof behind it, so the rating, the fixings and the finish must all sit on the same schedule.
What rating should window bars carry?
LPS 1175 B3, C5 or D10 to the room the window guards, or EN 1627 RC1 to RC6 where the order names the class.
Can bars sit on an escape window?
Yes, where the bar releases from inside without a key, a code or a card, so the window opens with one action.
Do bars block the light?
Bars guard the glass while light comes through. The spacing of the bars decides how much light reaches the room.
Fixed or hinged bars?
Fixed where the window never opens, hinged where it must open for cleaning, air or escape.
Who checks the bars?
The person who runs the building, on the round that walks the frontage. The record lives with the building file.