Fire door certification explained: test evidence to EN 1634-1, labels and certificates, what to ask for on the order and how to keep the proof valid.
- ✓Third-party test evidence with every product
- ✓Written specification you can issue to tender
- ✓Supplied and installed across the UK
Get a free project quote
Rating, written specification and budget range within one working day.
Confidential. No cost, no obligation.
Third-party tested
Evidence with every quote
UK manufactured
Made to your sizes
One accountable team
Specify, supply, install
Confidential handling
Details never shared
A fire door certificate is only as good as the test behind it. A door that carries a label and a certificate has a test report that names the leaf, the frame and the hardware as built, and a door that carries neither has only the word of the person who sold it.
Certification is the check that the door as made matches the door as tested. A third party looks at the test evidence and the build, and the certificate that follows names the doorset the evidence covers. A certificate for a different doorset proves nothing about the door on the order.
The periods a certificate names are set out in the commercial buildings fire door regulations guide, and the fire door inspection checklist names what each round should look for.
- EN 1634-1Fire resistance test for doorsets
- FD30 / FD60Fire resistance periods, 30 and 60 minutes
- BS EN 1634-3Smoke control, Sa and S200
- 4 mmGap round a fire door leaf
What certification proves: the door, the leaf and the test behind it
Certification proves that a doorset was tested and that the door supplied matches the doorset tested. The proof sits in three parts: the test report from the furnace, the certificate that names the doorset, and the label on the leaf that ties the door on site to the papers on file. A report without a label cannot be tied to a door, and a label without a report cannot be checked.
The test report is the foundation. It records the leaf, the frame, the seals, the hinges, the lock and the closer as fitted in the furnace, and the period the doorset held. A report that names a steel leaf proves nothing about a timber leaf, and one that names a closer proves nothing about a door fitted with another.
Ask for the papers before the order is placed, not after the doors arrive. A supplier who can show the test report and the certificate for the exact doorset on the schedule has nothing to hide. The how to specify security doors guide sets out the columns a schedule needs, and the proof belongs on one of them.
The test evidence: EN 1634-1 and what the furnace measured
Fire resistance is proved to EN 1634-1, and the letters after the period name what the furnace measured. E names integrity, the ability of the leaf to hold flame and hot gas back. EW adds radiation, and EI adds insulation, holding the heat back as well as the flame. A door that must guard an escape route takes FD30 or FD60, and the letters beside the period should match the risk the room faces.
The period follows the fire load behind the door. Thirty minutes is the period most doors carry, and sixty minutes is the period for the doors that guard a compartment wall or a room with a heavier fire load. The fire door regulations schools guide works through the periods for a school, and the fire door regulations hospitals guide covers them for a hospital.
Smoke is proved on a separate test, to BS EN 1634-3, with Sa for smoke at room temperature and S200 for smoke at 200 degrees Celsius. A door on a smoke path takes FD30S, and the seal that holds the smoke back must be the seal the test report names. The smoke control doors guide covers the doors that hold smoke back while people move past them.
The label on the leaf: what to read before the door is fitted
Every door that leaves the factory with certification carries a label on the leaf, usually on the top or hinge edge, where it can be read without taking the door down. The label should name the period, the standard the door was tested to, and the doorset it belongs to. A label that names only the period tells the reader too little to check.
Read the label on the day the door arrives, before the fitter starts work. Check the period against the schedule, the doorset name against the certificate, and the leaf, frame and hardware in the crate against the label. A door that arrives without a label, or with a label that does not match the schedule, should go back.
The label is the link between the door and the file. When the label is painted over, planed off or lost in a repair, the door can no longer be tied to its papers, and the proof is gone with it. The flat entrance doors guide covers the doors between a flat and the corridor.
The certificate and the schedule: the papers that travel with the door
Put the certificate on the schedule line beside the door it belongs to, with the period, the standard and the doorset name written out. A schedule that names the door but not the proof leaves the fitter to guess which certificate covers which opening. The security door cost factors guide works through what each step up the scale adds to the build.
Keep one certificate for each doorset on the order, not one for the whole building. A building with three doorsets needs three certificates, and one with a single doorset used on fifty openings needs one certificate and fifty labels that name it. The file should hold the certificate, the test report and the label details together, so the next reader can follow the chain from the door to the furnace.
Ask the supplier to send the papers with the quote, and keep them with the building file from the day the doors arrive. A certificate that turns up months after the handover cannot be checked against doors already fitted.
Fitting the door the way it was tested: the work that keeps the proof
A door only keeps its proof when it is fitted the way it was tested. The leaf, the frame, the seals, the hinges, the lock and the closer must all match the test report, because a single part changed for another leaves the doorset unproved. A closer swapped for a lighter one or a seal left off the frame breaks the chain between the door and the test.
Closers on a fire door need a power size of EN 3 or above to BS EN 1154, with the size chosen for the leaf fitted, and the fire door closers guide covers the sizes and the fitting. Hinges to BS EN 1935 carry the leaf through 200,000 cycles, grade 13 rated for 120 kg and grade 14 for 160 kg, and the fire door hardware guide covers the grades and the parts behind a working fire door.
The gap round the leaf must stay at 4 mm, because a wider gap lets fire and smoke past whatever the rating on the leaf says. Intumescent seals expand at around 200 to 250 degrees, and a seal that has been painted over or cut back leaves the gap open. The plant room door requirements guide covers the doors on the rooms that feed a building.
After the handover: the checks that keep the proof alive
A door that was proved on the day it was fitted can lose its proof in a year of use. The closer weakens, the seal hardens, the hinges wear, and a door that no longer shuts on its own no longer holds fire back. The routine that catches those faults keeps the certificate meaningful.
Walk the building on a set routine and look at every fire door in turn. Check that the leaf shuts fully, that the closer pulls it shut without help, that the seals are soft and unpainted, and that the gap round the leaf is still 4 mm. Write down each fault on the day it is found, with the door named and the date noted.
The person who runs the building owns the record, and the record should show the door, the fault, what was done about it and the date the work was finished. A complete record tells the next reader the doors were watched, and a record with gaps tells the next reader they were not. The security door maintenance checklist covers the doors that must hold both fire and forced entry.
The label check: period, standard and doorset read off the door
The round begins with the label, read while the door is still shut and the day is still young. It sits on the top edge or the hinge edge, where a reader can see it without lifting the door off its hinges, and a good label carries the period, the standard and the name of the doorset. A label that carries only the period leaves the reader with nothing to check against the file, and a label that paint has covered, a plane has taken off or a repair has lost leaves the door with no link to its papers. The label is read against the certificate that day, with the door named beside it.
A door with no label goes back, and so does one whose label disagrees with the schedule, and the same holds on the round: a door whose label cannot be read is a door whose proof cannot be shown. The certificate covers one doorset, and the test report holds the build the furnace saw, so the label, the certificate and the report must all name the same doorset. What each round should look for is listed in the fire door inspection checklist, and the fire door maintenance guide sets down the round that holds a door to its proof.
| What the round checks | What it looks for | What goes on the record |
|---|---|---|
| Label | Period, standard, doorset name | Label read, date, door named |
| Gap | 4 mm round the door, even on all sides | Gap measured, sides noted |
| Closer | Door shuts and latches on its own | Power checked, EN 3 or above |
| Seals | Strip in the groove, unpainted, soft | Strip named, faults listed |
| Hinges | Fixed tight, no play in the door | Hinge grade noted, faults listed |
The round writes down the gap, the label and the date
The gap is measured with the door shut, on the head, the sill and both jambs, because a gap that has opened on one side lets fire and smoke through, whatever the rating says. Four millimetres is the size the gap must hold, so the door can swing and still close the line when the heat comes, and a gap that has grown where the frame has shifted or the floor has risen is written down the day it is found, with the side and the size beside it. The size the gap must hold is stated in the fire door gaps guide, and the power a closer needs to shut the door is listed in the fire door closers guide. A closer that has lost its power leaves the door ajar, and a door left ajar leaves the escape route open with it, so the closer is tested on the same round, against the weight of the door it must move.
The record is the proof the round took place, and it stays with the person who runs the building. Each entry names the door and the fault, says what was done and carries the date the work was finished, so the next reader can trace the door back to the furnace without guessing. The fire door hardware guide names the parts and grades a fire door needs. Give each line of the schedule the period, the doorset and the certificate, and send the security door enquiry checklist with the enquiry.
When the proof breaks: changes that void a certificate
Some changes break the proof outright. A leaf cut down to fit a smaller opening, a vision panel added after the test, a lock changed for one the report does not name, or a closer swapped for a lighter one each leave the doorset different from the one tested, and a doorset that differs from the test has no proof.
Glazing is the change that catches most people out. A pane added to a solid leaf needs a test of its own, with the glass, the beads and the fixings proved together, because a pane in the wrong frame carries no proof at all. The fire rated glazed doors guide covers the glazed leaves that carry the higher periods, and the fire rated windows guide covers the windows beside them.
Steel and timber doors take different changes. A steel leaf takes a different repair from a timber leaf, and a hinge that suits one does not always suit the other. The steel versus timber fire doors guide works through the choice between the two, and the fire rated steel doors guide covers the steel leaves that carry higher periods.
Take the door out of service first, then work out what broke the proof
Cut a leaf down, add a vision panel, change a lock for one the report never names, or swap a closer for a lighter one, and the doorset on the wall is no longer the doorset the furnace proved. The first step is to take the door out of service on the route it guards, because a door that stands open to fire while its proof is argued over leaves the escape route open with it. The door on a stair core guards the way out, so a door on that route is taken out of service before any other, and the route is kept clear while the proof is worked out.
The file for the door is the place to start the repair, because the test report names the leaf, the frame, the seals, the hinges, the lock and the closer as fitted in the furnace. A part changed for its twin, the part the report names, puts the doorset back as it was tested, while a part changed for a different make leaves the door unproved. Keep the gap round the leaf at 4 mm, because a wider gap lets fire and smoke past whatever rating the leaf carries, and the fire door gaps guide states the gap the leaf needs. The fire door maintenance guide gives the routine that keeps a door as it was proved, and the fire door inspection checklist lists what each round should check.
| Change | What it breaks | What puts the proof back |
|---|---|---|
| Leaf cut down | The leaf the test proved | A new leaf proved with the frame |
| Vision panel added | Glass, beads and fixings unproved | A glazed leaf proved as a doorset |
| Lock changed | The lock the report names | The lock the report names, fitted as tested |
| Closer swapped | Power below EN 3 | A closer of EN 3 or above to BS EN 1154 |
| Hinges changed | The hinge the report names | Grade 13 or 14 to BS EN 1935, as tested |
| Seal painted | The strip cannot swell | The strip the report names, unpainted |
The paper trail after a change decides whether the door stays
Every change to a fire door belongs on the record with the door named and the date noted, because the next reader must follow the chain from the door to the furnace without guessing. A certificate that turns up months after the handover cannot be checked against doors already fitted, so the papers travel with the door from the day it arrives, and the certificate, the test report and the label details sit together in the building file. The record sits with the person who runs the building, and each entry should name the door and the fault, say what was done about it, and carry the date the work was finished.
A door that holds fire back and holds an intruder out at once needs a proof for each job, and the fire and security doors dual certification guide explains how two proofs sit on one leaf. The how to specify security doors guide lists the columns a schedule needs. Put the period, the doorset and the certificate on every line of the schedule, then check the security door enquiry checklist for what the enquiry must carry with it.
The building order: proof on every line
Put every fire door on one list before the order goes out, with the position, the period, the doorset name and the certificate beside each opening, so the door that turns up is the door that was tested. A list that names one door for the whole building leaves the fitter to guess, and a guess is not a proof.
Go through each quote line by line against the list before ordering. A part left off a quote still has to be bought, and fitting it round a door already in use costs more than ordering it with the door. The fire and security doors dual certification guide works through how the two proofs share one leaf, where a door must hold fire and resist attack at once.
Keep the test reports with the doors from the day they arrive, so the proof is never far from the leaf it belongs to. The keeping an LPS 1175 rating valid guide sets out what breaks a rating once a door is fitted.
| Position | Door | Proof | What to check |
|---|---|---|---|
| Corridor | Fire door | FD30, EN 1634-1 | Label, closer, seals |
| Stair core | Fire door | FD60, EN 1634-1 | Label, hinges, gap |
| Smoke path | Fire door | FD30S, BS EN 1634-3 | Seal, closer, release |
| Plant room | Fire door | FD60, EN 1634-1 | Label, seals, latch |
| Flat entrance | Fire door | FD30, EN 1634-1 | Label, lock, closer |
A fire door certificate is a chain from the furnace to the leaf, so the test report, the certificate and the label must all name the same doorset.
What does fire door certification mean?
It means a third party has checked that the doorset as made matches the doorset tested to EN 1634-1, and the certificate names the doorset the evidence covers.
What should a fire door certificate name?
The period, the standard the door was tested to, and the doorset, with the leaf, frame and hardware as fitted in the test. A certificate that names a different doorset proves nothing about the door on the order.
How do I check a fire door label?
Read it on the day the door arrives, before the fitter starts work. Check the period against the schedule and the doorset name against the certificate, and send the door back if the label does not match.
Can a fire door lose its certification?
Yes. A leaf cut down, a vision panel added after the test, a lock or closer changed for one the report does not name, or a seal painted over each leave the doorset different from the one tested.
Who keeps the fire door certificates?
The person who runs the building, with the building file. The file should hold the certificate, the test report and the label details for every doorset, so the next reader can follow the chain from door to furnace.
Get a free quote