Museum security doors: rated doors for galleries, stores and entrances that guard collections, with glazing, access control, fire proof and one schedule.
- ✓Third-party test evidence with every product
- ✓Written specification you can issue to tender
- ✓Supplied and installed across the UK
Get a free project quote
Rating, written specification and budget range within one working day.
Confidential. No cost, no obligation.
Third-party tested
Evidence with every quote
UK manufactured
Made to your sizes
One accountable team
Specify, supply, install
Confidential handling
Details never shared
A museum door guards objects that cannot be replaced. It opens for visitors all day, it guards the store where the collection sits, and it must hold fire back on the escape route, all on the same leaf in many museums. The door that fails on one of those jobs leaves the collection open to theft, to fire, or to a claim the insurer will not pay.
The order starts with the collection, not with the door. A gallery with a glazed front asks for a different door from a store that no visitor ever sees, and a museum that loans objects to other museums asks for different locks from one that never lends. The objects, the visitors and the people who pass through the door decide the rating before the leaf is chosen.
The doors in a museum sit inside one schedule, and an order that names each one plainly gets the right door on the right opening. The commercial buildings fire door regulations guide sets out the periods for the shared parts of a public building, and the warehouse security doors guide covers the doors on the stores behind the public rooms.
- LPS 1175 B3 / C5 / D10Forced entry ratings, three, five and ten minutes
- FD30 / FD60Fire resistance periods tested to EN 1634-1
- EN 356 P6B / P7B / P8BManual attack resistance for glazing
- TS 007 3-starCylinder and handle sets
The gallery door: what visitors see and what thieves must not pass
The gallery door is the face of the museum, and the door in it must let visitors see the collection while it keeps thieves out. A glazed door shows the gallery to the entrance hall, so the glass must be proved for the job it does, and the frame and the fixings must be proved with the glass, because a pane in the wrong frame carries no proof at all.
Impact resistance is proved to EN 356, with the top classes set by axe blows: 30 to 50 for P6B, 51 to 70 for P7B, and 70 or more for P8B. A gallery that holds objects of high value takes a higher class than a corridor door, so the class follows the risk the room faces, not the glass the catalogue shows first.
The bullet resistant versus bulletproof glass guide works through the choice between glass types, and the fire rated windows guide covers the windows that share the same wall.
The store door: the leaf that guards the collection out of sight
The store holds the objects that are not on display, so its door is the first leaf a thief tries. It takes no glass, it takes a solid leaf, and it takes a rating proved in a live test, because a door that looks strong and was never tested is only a guess. The loading bay doors guide covers the bays where loans arrive and leave.
Forced entry is proved to LPS 1175, with B3 holding three minutes against category B tools, C5 holding five minutes against category C tools and D10 holding ten minutes against category D tools, all under Issue 8.2, dated September 2024. The rating on the order should match the value of the objects behind the door.
A TS 007 3-star set belongs on the store door, with a 1-star cylinder beside a 2-star handle or escutcheon, and the hinges must match the leaf they carry: BS EN 1935 grade 13 takes 120 kg and grade 14 takes 160 kg, each proved through 200,000 cycles.
Glazing and vision: seeing the collection without weakening the door
A vision panel lets staff see the gallery without opening the door, and a glazed screen lets visitors see the collection from the hall. The glass in both must be proved for the job, because a pane that was never tested is a hole in the door, whatever the leaf around it can hold.
Fire rated glazing is proved to EN 1634-1, with FD30 or FD60 and the letters E, EW or EI naming what the furnace measured. The fire rated glazed doors guide covers the glazed leaves that carry the higher periods, and the bullet resistant glass cost guide works through what each step up the scale adds to the build.
The frame carries the rating as much as the glass does, because a thief or a flame that passes the pane still meets the frame.
Staff, contractors and the doors they use: access control in a museum
Staff keys multiply in a museum, and every key that leaves with a member of staff is a key in the wrong hands. A fob suits the staff door, because a fob can be stopped when staff leave and a key cannot, and the record should name who holds each fob and each key, so the next manager can see who can open which door.
The store door must lock when it shuts, with no one having to remember to turn the key. A closer that pulls the leaf shut every time and a latch that catches as the door closes do the job on their own, and the security turnstiles guide covers readers, fobs and biometrics in the lane.
One system across the museum keeps the doors together, so one card opens the store, the office and the back door, and one stopped card stops working everywhere at once. The door on the escape route must still release on alarm, so no one is held inside when the alarm sounds, whatever the access system says.
One leaf, two proofs: fire and forced entry in a gallery
A museum door often must do two jobs at once. It must hold fire back for its period, and it must resist a forced entry, and a door that must do both needs a proof for each job. Fire is proved to EN 1634-1 and forced entry to LPS 1175, and the two proofs sit on the same schedule line, because a door proved for one job and not the other leaves the collection open on one side.
The period follows the fire load behind the door. Thirty minutes is the period most gallery doors carry, and sixty minutes is the period for the doors that guard a compartment wall or a store with a heavier fire load, and a door on a smoke path takes FD30S, with the seal proved to BS EN 1634-3, to Sa for smoke at room temperature and S200 for smoke at 200 degrees Celsius.
The dual certification guide sets out how the two proofs share one leaf. For the closer, no fire door takes less than EN 3 to BS EN 1154, and the sizes and the fitting are covered in the fire door closers guide, while the grades and the parts behind a working fire door are covered in the fire door hardware guide.
An object on loan crosses four doors before it reaches the van
A museum that loans objects to other museums asks for different doors from one that never lends, because the object leaves the store, crosses the corridor, passes the entrance hall and reaches the loading bay, and every door on that route guards the same object. The rating on the order should match the value of the objects behind the door, and the weakest door on the route sets the rating for the whole journey, not the strongest. The schedule should name the route the object takes, door by door, so the rating on each door can be read against the object it guards, and a door left off the list leaves a gap in the route no lock can close.
The store door takes no glass, it takes a solid leaf, and it takes a rating proved in a live test, because a door that looks strong and was never tested is only a guess. Forced entry is proved to LPS 1175, with B3 holding three minutes, C5 holding five minutes and D10 holding ten minutes, all under Issue 8. The loading bay doors guide covers the bays where loans arrive and leave, and the warehouse security doors guide covers the doors on the stores behind the public rooms.
| Door on the route | What it guards | What to check before the loan moves |
|---|---|---|
| Store | The collection out of sight | Solid leaf, lock, hinges, closer |
| Corridor | The object in transit | Leaf shut, seals soft, gap at 4 mm |
| Entrance hall | The object in public view | Glazing proved, frame proved with it |
| Back door | The door staff use after hours | One card opens it, one stopped card stops everywhere |
| Loading bay | The object at the van | Leaf, lock and closer proved together |
The rating on the route is the rating of its weakest door
Where a glazed door opens the gallery to the entrance hall, the glass needs proof for the job it does, and the frame and the fixings need proof beside it, because a pane in the wrong frame holds no proof at all. Glazing that must hold fire is proved to EN 1634-1 with the frame and the fixings, at FD30 or FD60, with E, EW or EI naming what the furnace measured. The bullet resistant versus bulletproof glass guide weighs the choice between glass types, and the fire door regulations museums guide sets out the periods the shared parts of a museum must hold.
The store door takes a TS 007 3-star set, with a 1-star cylinder beside a 2-star handle or escutcheon, and the hinges must match the leaf they carry. Hinges to BS EN 1935 carry the leaf through 200,000 cycles, grade 13 rated for 120 kg and grade 14 for 160 kg, so match the hinge to the weight of the leaf it carries, and put the lock and the hinges on the same schedule line as the leaf.
One access system across the museum keeps the doors together, so a single card opens the store, the office and the back door, and a card that is stopped stops working at every door at once. Whatever the access system says, the door on the escape route must still release when the alarm sounds, so nobody is held inside. Readers, fobs and biometrics in the lane are covered in the security turnstiles guide. List position, fire period, forced entry rating, glazing and hardware on every line, then use the security door enquiry checklist to see what the enquiry should hold.
Sealing and the air inside: the door that keeps the gallery steady
A gallery keeps its air steady for the objects inside, and the door must not undo that work. A leaf that leaks air lets dust and damp through the gap, so the seals round the leaf matter as much as the lock, and the gap round a fire door leaf must stay at 4 mm, because a wider gap lets fire and smoke past whatever the rating on the leaf says.
The seal must stay soft through the seasons, because a seal that goes hard leaves a gap round the leaf. Check the seals first on every round, because a seal that has come away or been painted over leaves the gap open, and the keeping an LPS 1175 rating valid guide sets out what breaks a rating.
Keeping a rating valid means keeping the door as it was proved, with the same leaf, the same frame and the same hardware the test report names. A door that has been changed since the test has no proof left, so the file should hold the test report for every door in the museum, and the report should name the leaf, the frame and the hardware as fitted.
The entrance that must welcome and resist: the public door
The public entrance must welcome visitors and resist a thief at the same time. It opens for crowds all day, and it must hold when a person tries to force it, so the leaf, the lock and the closer must all be proved for the duty they carry, and the opening force must stay below 30 N for the first 30 degrees of travel and below 22.5 N beyond, under BS 8300 and Approved Document M.
Panic hardware to BS EN 1125 takes a bar across at least 60 percent of the leaf width, and it is the hardware for a room that holds more than 60 people. A gallery that fills for an exhibition needs that bar, because a crowd that cannot open the door in a fire is a crowd held inside, and the smoke control doors guide covers the doors that must hold smoke back while people move past them.
A hold-open device keeps the door open during the day and lets it shut when the alarm sounds, and BS EN 1155 covers the hold-open device, so the wedge belongs in the bin and the device belongs on the order.
The morning opening: the first person through the entrance sets the day
The museum opens the same way each morning, and the first person through the entrance sets the day for every door behind it. The entrance is checked before the first visitor arrives: the locks are released, the doors are opened, and each one is watched as it moves, to see that it shuts and latches on its own, that the seals sit soft and that the glazing stands whole in its frame. A door that will not latch, a closer with no power left or a pane cracked overnight is found in the morning, while the museum is still empty.
The morning check is short, and it follows the same order each day, so nothing is missed when the rota changes. The person who opens the museum walks the entrance, the gallery doors and the store door, and each fault is written on the record that same day. The fire door regulations museums guide carries the periods the museum’s shared parts take, and the security turnstiles guide covers the readers, fobs and biometrics a visitor meets in the lane. A door on the escape route must still open when the alarm sounds, so the way out stays open, and a panic bar on a route that serves more than 60 people must span at least 60 percent of the width of the door, to BS EN 1125.
| What the morning checks | What it looks for | What happens when it fails |
|---|---|---|
| Entrance locks | Released cleanly, doors open freely | Lock checked, fault on the record |
| Closers | Door shuts and latches on its own | Closer power checked, EN 3 or above |
| Glazing | Pane whole, frame and fixings sound | Pane changed, proof checked |
| Seals | Strip soft in the groove, unpainted | Strip changed for the strip named |
Open all day, guarded all day: glazing, locks and the crowd at the door
Once the museum is open the entrance must do two jobs at once, and it must do both all day. Visitors must see the collection through the glazing and pass through without a queue forming, while the locks, the glazing and the frame must hold against the thief who tries them. Glass that shows the gallery to the entrance hall needs proof for the work it does, and so do the frame and the fixings round it, because a pane set in the wrong frame brings no proof with it. The choice between glass types is weighed in the bullet resistant versus bulletproof glass guide, and the bays where loans arrive and leave are covered in the loading bay doors guide.
A door that carries D10 for forced entry and FD60 for fire names both proofs in one line: ten minutes against forced entry to LPS 1175 Issue 8, and sixty minutes against fire to EN 1634-1. The store door takes a lock set to TS 007, built from a 1-star cylinder and a 2-star handle, which together make the 3-star set, and hinges that match the door they carry. The warehouse security doors guide covers the store doors behind the public rooms. Give each line the position, the period, the rating, the glazing and the hardware, and let the security door enquiry checklist travel with the enquiry.
One schedule for the whole museum: every door on one line
Write the enquiry as one schedule with a line for every door in the museum, and put the position, the fire period, the forced entry rating, the glazing and the hardware on each line, so the door that arrives is the door that was proved. The periods for the shared parts of a museum are named in the commercial buildings fire door regulations guide.
Lay the quotes next to each other and read each line, because a quote that drops a seal or a closer is not cheaper, only shorter, and the missing line is paid for later. What each step up the scale adds to the build is worked through in the security door cost factors guide, and the same discipline column by column is in the how to specify security doors guide.
The inspection round looks at the closers, the seals, the locks and the glazing, and each fault goes on the record the day it is found, and the fire door inspection checklist names what each round should look for.
| Position | Door | Rating | What to check |
|---|---|---|---|
| Gallery | Glazed security door | LPS 1175 B3 | Glass, frame, closer |
| Store | Solid security door | LPS 1175 C5 | Lock, hinges, closer |
| Entrance | Glazed fire door | FD30 + B3 | Panic bar, seals, release |
| Escape route | Fire door | FD30S | Seals, closer, release |
| Plant room | Fire door | FD60 | Seals, closer, latch |
A museum door must welcome visitors, guard the collection and hold fire back, so the rating, the glazing and the locks must all sit on the same schedule.
What rating do museum security doors need?
It depends on the opening. For forced entry, LPS 1175 B3, C5 or D10, with three, five or ten minutes behind each grade, and for fire, FD30 or FD60 where the door guards an escape route or a compartment wall.
Do gallery doors need fire rated glazing?
Yes, where the door sits on an escape route or a compartment wall. The glazing is proved to EN 1634-1 together with the frame and the fixings, and the period follows the fire load behind the door.
How are museum stores protected?
With a solid leaf proved to LPS 1175, a TS 007 3-star lock set, and access control that names who holds each fob and each key.
Who holds the keys to a museum?
Each member of staff takes a fob or a key for the doors they use, and the record names who holds each one. When staff leave, a fob can be stopped at once, while a key that leaves with a member of staff should be treated as a key in the wrong hands.
Who checks museum security doors?
The person who runs the museum, on the routine the fire risk assessment sets. Each round looks at the closers, the seals, the locks and the glazing, and each fault goes on the record the day it is found.