Certified physical security

ArxBridge
Steel door sample in a security test frame with an assessor in a UK test laboratory

ArxBridge

Access Control Doors

Access control doors: readers, fobs and biometrics, fail safe and fail secure, release on alarm, one system across the site and one schedule.

  • ✓Third-party test evidence with every product
  • ✓Written specification you can issue to tender
  • ✓Supplied and installed across the UK
Prefer to talk?+44 7352 267239

Get a free project quote

Rating, written specification and budget range within one working day.

ArxBridge Quote Form

Confidential. No cost, no obligation.

Third-party tested

Evidence with every quote

UK manufactured

Made to your sizes

One accountable team

Specify, supply, install

Confidential handling

Details never shared

A door with access control decides who may pass and who must wait outside. The reader on the wall, the lock in the leaf and the record in the office work as one system, and a door that opens for the wrong person has failed even when the leaf holds.

The order starts with the people, not with the reader. An office with staff who come and go all day asks for a different credential from a plant room that only two engineers ever enter, and a door on an escape route asks for a different release from a door on a store.

The readers, the locks and the records all sit inside one schedule, and an order that names each one plainly gets the right door on the right opening. The security turnstiles guide covers readers, fobs and biometrics in the lane, and the gate automation guide covers how a powered barrier is driven and released.

  • LPS 1175 B3 / C5 / D10Forced entry ratings, three, five and ten minutes
  • TS 007 3-starCylinder and handle sets
  • BS EN 1125Panic hardware for escape
  • BS EN 1154 EN 3Closer power on fire doors

Readers, fobs, cards and biometrics: the credential that fits the door

A card, a fob, a PIN, a fingerprint and a face each suit a different door. A card suits a door that many hands use every day, because it is cheap to hand out and easy to stop, while biometrics suit a door that only a few people ever open, because a fingerprint cannot be lent to a colleague or left in a drawer.

The credential must match the risk behind the door. A store takes a fob, and a server room takes a second factor on top of the card, because the room that holds the data asks for more proof than the room that holds the paper. The server room doors guide covers the doors on the rooms that hold the machines, and the data centre physical security by zone guide sets out the doors zone by zone.

The reader sits outside and the release sits inside, and the wiring between them must not weaken the leaf. A reader fixed through a fire door leaf without the right fixings leaves a hole in the proof, so the reader, the cable and the fixings belong on the schedule beside the lock.

Fail safe or fail secure: the choice that decides what happens in a fire

Every electric lock fails one way or the other when the power goes, and the choice belongs on the schedule before the order is placed. A fail safe lock opens when the power fails, and a fail secure lock stays locked, so the site must decide which failure it can live with on each door.

Escape route doors fail safe, so no one is held inside when the power goes or the alarm sounds. Stores and strongrooms fail secure, so the goods stay locked when the power goes, and the commercial buildings fire door regulations guide sets out the periods for the shared parts of a building.

Battery backup keeps the lock working through a short cut, but the manual release is what saves the day when the power stays off. The release must work on power failure as well as on alarm, and it must sit where a person can reach it in the dark without hunting for it.

Need this specified for your project?Free rating, written specification and budget range within one working day.
Get a free quote

Release on alarm: the escape route that must always open

When the alarm sounds, the door on the escape route must release at once. No key, no card and no code may stand between the person and the street, and the release must work for everyone in the building, including a visitor who has never seen the door before.

Panic hardware to BS EN 1125 takes a bar across at least 60 percent of the leaf width, and it is the hardware for a room that holds more than 60 people. The opening force must stay below 30 N for the first 30 degrees of travel and below 22.5 N beyond, under BS 8300 and Approved Document M, so a person of any strength can push the door open.

Hold-open devices keep a door open during the day and let it shut when the alarm sounds, and BS EN 1155 covers the hold-open device. A door held open by a wedge or a hook has no hold-open device at all, so the wedge belongs in the bin and the device belongs on the order. The smoke control doors guide covers the doors that must hold smoke back while people move past them.

One system across the site: every door on the same record

One card should open the office, the stores and the yard, and one stopped card should stop working everywhere at once. A site where each door runs on its own system leaves the manager with a pocket of cards and no single record of who can open what, and the door that was never added to the system is the door no one controls.

The controller, the wiring and the software belong on the order with the doors, not after them. A door added to the system later costs more than a door ordered on it, because the cable run, the reader and the lock must all be fitted round a door that is already in use. The warehouse security doors guide covers the doors on the building itself, and the plant room door requirements guide covers the doors on the rooms that feed the building.

Doors in different buildings can sit on one system, so the record names every door and every credential in one place. The fire door regulations for offices guide sets out the periods for the doors inside an office building.

A card that still works after its holder has left the job is a door with no control, even when the reader, the lock and the record all look sound. The card was issued for a job that has ended, yet nothing on the door knows that, so the person who holds it can walk in as if the job were still theirs.

Joiners, leavers and role changes: the names the record must track

Every joiner needs a start date on the record, every leaver needs a finish date, and every move to a new team needs the old doors taken off the card on the same day the new doors go on. A card that keeps the doors of a past role gives its holder a route through rooms that no longer belong to the job, and the site only learns of it when someone asks why that person was in a room they never needed to enter.

New starters often arrive before their card does, so a temporary pass covers the first days and dies on the date the permanent card is handed over. The door entry system at the main entrance lets staff inside check a caller before the door opens, which keeps a visitor pass from becoming a route into rooms beyond the visit.

Role changes cause more trouble than leavers, because a move feels like a small change and the record is left as it was. The person keeps the store, the plant room and the office from the old team, then gains the rooms of the new team.

When a role changes, the doors the card opens change with it

The monthly leaver check reads the staff list against the card list and asks one question of every name: does this person still work here, and do the doors on the card still match the job? A name with no job beside it is stopped that day, and a name with the wrong doors beside it is cut back to the doors the current job needs.

Sites that still run on keys face the same question in a different form, and a master key system names the person who holds each key, so a key held by a leaver is chased on the same monthly round as a card. The record names the key, the holder and the date it must come back, and a key with no holder beside it is treated as lost.

A card stopped on the record must stop at every door at once, not at the main entrance first and the side doors later. An emergency exit door still opens from inside without a card, so stopping a card never traps anyone behind it, and panic hardware on that door gives one push that works in the dark. The lock behind the electric lock is checked on the same round, because the key override must still turn when the reader has no power.

Credential Monthly check Action when the job ends
Card Name against the staff list Stopped on every door the same day
Role change Doors beside the new job Old doors taken off the card
Temporary pass Expiry date beside the name Pass dies on the date it was given

Put the leaver check on the calendar when the order is written, and the security door enquiry checklist names what the enquiry must carry beside it.

The audit trail: who passed, when, and through which door

Every pass through an access control door writes a line: who passed, when they passed, and through which door. The trail shows the door that was forced, the card that was used twice in one hour, and the hour when no one should have passed at all, so the record is worth more than the lock on its own.

The trail must be kept and checked, because a record no one reads is no record at all. A weekly look at the trail catches the card that was used at three in the morning and the door that was held open for an hour, and each finding belongs on the record beside the fault it names.

The trail names people, so the file that holds it should be held by the people who need it and no one else. The names, the times and the doors stay in the file the manager holds, and the file leaves the building only with the manager.

The key override: the door that still opens when the system fails

The electric lock is only half the door, and the cylinder behind it is the other half. Ask for a TS 007 3-star set, a 1-star cylinder with a 2-star handle or escutcheon, and fit a thumb turn on the inside, so the person in the room can leave without hunting for a key.

The electric lock must not fight the closer. A closer that pulls the leaf shut every time needs no fire door taking less than EN 3 to BS EN 1154, with the power size chosen for the leaf that is fitted, and hinges to BS EN 1935, with grade 13 carrying 120 kg and grade 14 carrying 160 kg, each through 200,000 cycles. The fire door closers guide covers the sizes and the fitting, and the fire door hardware guide covers the grades and the parts behind a working fire door.

The key override matters when the system fails. When the reader is dead and the power is off, the key must still open the door, and the key belongs with the person on duty, not in a drawer in an office that is locked.

Visitors, contractors and the door they use once

Visitors take the intercom, and contractors take a temporary credential that ends when the job ends. The door they use should open for them once, for the job they came to do, and no more, because a visitor who can walk the whole building is no visitor at all.

The temporary credential must die on its own. A code that outlives the job is a door left open, so the code should end on the day the job ends, and the record should name the door, the contractor and the date the credential died. The hospital security doors guide covers the doors on the buildings where visitors and contractors pass every day, and the school security doors guide covers the doors on a site where safeguarding sets the rules.

A credential has a life. It is issued on the first day, it is used every day after, and it ends when the holder leaves, loses it, or no longer needs the doors it opens. The record must follow each of those steps, because a card that still opens a door after its holder has gone is a door with no control at all, and the site only finds out when the wrong person walks through it.

The lost card is stopped on the record, not at the reader

When a card or fob goes missing, the first step is to stop it on the system, before anyone walks to the door it guards. The reader on the wall cannot tell a lost card from a kept one, so the stop must happen where the record lives, and it must reach every door the card could open at the same time.

A lost credential that stays live overnight is a key left in a lock. The person who reports the loss should hear the same day that the card no longer opens anything, and the record should name the card, the date it was stopped, and the doors it used to open. A door entry system that pairs an intercom with a reader lets the person inside check a caller before the leaf moves, which matters on a door that takes visitors all day.

When a member of staff leaves, the credential must end with the job. The leaving date should be written on the record the day the notice is given, so the card stops on the last day and not a week later, and any key handed back should be noted beside the card it sat with. Where a site still runs on keys, a master key system keeps the number of keys down and names the person who holds each one.

A contractor is given a pass that stops working on the last day of the job, and the record names the door it opens and the date it stops. If the pass still works after the contractor has gone, the door is open to a stranger, so the stop date is written on the record the day the pass is handed out, not the day the job finishes.

Choose the failure the building can live with, door by door

When the power goes, every electric lock drops to one side or the other, and the site decides the side door by door, not once for the whole building. A door on an escape route opens when the power fails, because no one may be held inside, while a store stays shut, because the goods inside must stay locked until the power returns.

Battery backup covers a short cut, but it does not change the choice. The manual release is what carries the door through a long cut, and it must be found by touch in the dark and worked with one hand. An emergency exit door opens from inside without a credential, so the fail position never traps anyone behind it.

The fail position belongs on the schedule beside the credential, so the door that arrives matches the door the site can live with. A schedule that names the lock but not the failure leaves the choice to the fitter, and the fitter cannot know which failure the building can live with. Panic hardware on the escape door gives one push bar across the leaf, so the release works in the dark, and the lock behind the electric lock decides whether the key override still works when the reader is dead.

Credential When it ends What happens next
Card Last day of the job Stopped on every door at once
Fob Reported lost Stopped the same day
Temporary code End of the visit Dies on its own

Put the credential list with the order, and the security door enquiry checklist shows what the enquiry must carry beside it, so the door that arrives matches the door the site asked for.

One schedule for every door: the order that names the system

Write the enquiry as one schedule with a line for every door on the site, and put the door, the credential, the release and the lock on each line, so the door that arrives is the door that was proved. The university security doors guide covers the doors on an estate where one system runs across many buildings.

Put the quotes side by side and check each line, because the quote that leaves a reader or a release off the list is not cheaper, only shorter, and the missing line is paid for later. The how to specify security doors guide runs through the same discipline column by column, and the security door cost factors guide works through what each step up the scale adds to the build.

File the test reports, the ratings and the inspection routine with the doors when they arrive, and write the routine into the handover pack. The keeping an LPS 1175 rating valid guide sets out what breaks a rating, and the fire door inspection checklist names what each round should look for.

Door Credential Release What to check
Office entrance Card or fob Fail safe Reader, lock, closer
Server room Card plus PIN Fail secure Second factor, hinges
Store Fob Fail secure Lock, closer, latch
Escape route None, panic bar Fail safe Panic bar, release, seals
Plant room Key Manual release Lock, closer, seals

Access control only works when the reader, the lock and the release sit on the same schedule, so the door that opens for staff still opens for everyone in a fire.

What is fail safe on an access control door?

The door opens when the power fails or the alarm sounds. Escape route doors fail safe, so no one is held inside, and the choice is named on the schedule before the order is placed.

Fail safe or fail secure: which one fits?

The escape route takes fail safe and the store takes fail secure. A door that must open in a fire cannot stay locked, and a door that guards goods cannot open when the power goes.

Do access control doors need a fire rating?

Where the door sits on an escape route or a compartment wall, yes. Fire is proved to EN 1634-1 and forced entry to LPS 1175, and each proof must name the door that will be fitted.

Card, fob or biometrics: which credential fits?

The door and the people decide. A card or a fob suits many hands, and biometrics suit a door that only a few people ever open, because a credential that cannot be passed on cannot be lent.

Who checks access control doors?

The person who runs the site, on the routine the access plan sets. Each round looks at the readers, the locks, the releases and the trail, and each fault goes on the record the day it is found.

Specifying access control doors for a site?Send the door schedule and the access plan for a tested door quotation.
Get a free quote

Related

More in guides for specifiers

10 mistakes when specifying certified security doors 10 steps to specify an LPS 1175 door Acceptance and Snagging of a Security Door or Barrier Job Acoustic Doors: Ratings and Specification After a Forced Entry Attempt: Checking a Security Door Airport Security Doors Anti-Ligature Doors for Mental Health Wards Anti-Ram Bollards Anti-ram gates and barriers: protecting vehicle entrances Arcade Security Doors Explained Automatic Doors Automatic Gates Cost Factors Automatic Vehicle Barriers Ballistic Panels Bank Security Doors Bingo Hall Security Doors Explained Blast doors: glazed vs solid and how they are rated Blast protection window film: what it does and what it cannot do Blast resistant windows: what drives the cost and how to specify them Bollard Cost Factors Explained Bollard regulations in the UK: spacing, height and depth Bookmaker Security Doors Explained Builders Merchant Security Doors Bullet Resistant Glass Cost Factors Bullet resistant glass ratings explained: BR1 to BR7 and SG classes Bullet resistant vs bulletproof glass: what the difference means Buying Security Doors and HVM Through Public Frameworks Car Park Security Doors Explained Car Showroom Security Doors Casino Security Doors Explained CDM 2015 Duties When Security Doors, Shutters or HVM Are Installed Cinema Security Doors Cleanroom Doors Cold Store Doors College Security Doors Commissioning, Handover and the O&M Manual for Security Doors and HVM Communal entrance doors for flats: Secured by Design and what to specify Community Centre Security Doors Control Room Doors Court Security Doors Crash Rated Fences and HVM Fencing Explained Data centre physical security: doors, glazing, HVM and shielding by zone Dental Practice Security Doors Depot Security Doors Explained Door Entry Systems Due Diligence When Selecting Vehicle Security Barriers Emergency Exit Doors EMP Shielding Cost Factors Explained Exhibition Centre Fire Door Rules Exhibition Centre Security Doors Factory Security Doors Faraday cage vs RF shielded room: what a business needs FB4 vs FB6 vs FB7: how to choose a ballistic rating Fire and security doors: how dual certification works Fire Compartmentation Fire Curtains Fire Door Certification Fire Door Closers Explained Fire Door Cost Factors Fire Door Duties of the Accountable Person Fire Door Gaps Fire Door Hardware Explained Fire door inspection checklist for steel and timber doors Fire Door Maintenance Fire Door Regulations Care Homes Fire Door Regulations for A and E Departments Fire Door Regulations for Airports Explained Fire Door Regulations for Bowls Clubs Fire door regulations for commercial buildings in the UK Fire Door Regulations for Dialysis Centres Fire Door Regulations for Hockey Clubs Fire Door Regulations for Hospitals Explained Fire Door Regulations for Offices Explained Fire Door Regulations for Operating Theatres Fire Door Regulations for Retail Explained Fire Door Regulations for Schools Explained Fire Door Regulations for Snooker Clubs Fire Door Regulations for Stadiums Fire Door Regulations for Student Accommodation Fire Door Regulations for Warehouses Fire Door Regulations Leisure Centres Fire Door Regulations Restaurants Fire Door Remediation Programme for Housing Providers Fire Door Rules for Badminton Clubs Fire Door Rules for Bingo Halls Fire Door Rules for Bookmakers Fire Door Rules for Bowling Alleys Fire Door Rules for Car Parks Fire Door Rules for Car Showrooms Fire Door Rules for Cinemas Fire Door Rules for Climbing Centres Fire Door Rules for Colleges Fire Door Rules for Community Centres Fire Door Rules for Cricket Clubs Fire Door Rules for Dental Practices Fire Door Rules for Depots Explained Fire Door Rules for Golf Clubs Fire Door Rules for GP Surgeries Fire Door Rules for Gyms Explained Fire Door Rules for Ice Rinks Fire Door Rules for Maternity Units Fire Door Rules for Mental Health Units Fire Door Rules for Museums Fire Door Rules for Oncology Units Fire Door Rules for Opticians Fire Door Rules for Pawnbrokers Fire Door Rules for Petrol Stations Fire Door Rules for Pharmacies Fire Door Rules for Ports Fire Door Rules for Post Offices Fire Door Rules for Prisons Fire Door Rules for Rehabilitation Centres Fire Door Rules for Self Storage Fire Door Rules for Shopping Centres Fire Door Rules for Squash Clubs Fire Door Rules for Supermarkets Fire Door Rules for Swimming Pools Fire Door Rules for Tennis Clubs Fire Door Rules for Theatres Fire Door Rules for UK Arcades Fire Door Rules for UK Casinos Fire Door Rules for UK Hospices Fire Door Rules for Walk-in Centres Fire Door Signage Fire Door Vision Panels Fire Doors and Gateway 2 in Higher-Risk Buildings Fire Rated Glass Cost Explained Fire Rated Sliding Doors Explained Fire Rated Windows Cost Factors Fire Rated Windows Explained Fire Safety Enforcement Notices and Fire Doors: What the Responsible Person Must Do Flat Entrance Doors: PAS 24 and Fire Rated Forced Entry vs Ballistic vs Blast: Which Rating a Site Needs Garage Security Doors Explained Gate Automation Explained Golden Thread Records for Fire Doors GP Surgery Security Doors Explained Gym Security Doors Explained High Speed Doors HMO Fire Doors Hospice Security Doors Explained Hospital Security Doors: Wards, A&E, Plant Hospital Security Gates Hotel Fire Doors Hotel Security Doors How to choose HVM bollards: fixed, shallow mount, removable and automatic How to keep an LPS 1175 door rating valid after installation How to Specify Fire Doors in a Housing Tender How to specify security doors: a checklist for architects How to Verify a Secured by Design Listing How to Verify an LPS 1175 Certificate on Red Book Live How to Write an Operational Requirement for Physical Security HVM planters and street furniture: protection that blends in In-Service Care of Vehicle Security Barriers Installation Handover: LPS 1175 Doors and PAS 68 Barriers Intumescent Seals ISO 16933 explained: EXV and SB classes and hazard ratings ISO 22343 vehicle security barriers explained Keeping a Dual-Certified Fire and Security Door Valid in Service Laboratory Security Doors Layered Security for a Site: Deter, Detect, Delay, Mitigate, Respond Lead Times and Programme Risks for LPS 1175 Doors Leisure Centre Security Doors Library Security Doors Listed Building Fire Doors Loading Bay Doors Explained Lockdown and Access Control Hardware on an LPS 1175 Door LPS 1175 Gates and Grilles Explained LPS 1175 Issue 8 explained: from SR1 to SR8 to A1 to H20 LPS 1175 Roller Shutters LPS 1175 vs ASTM F2781 and Other US Ratings Explained LPS 1175 vs EN 1627: how UK and European burglar resistance ratings compare LPS 1175 vs PAS 24: which security standard does your door need? LPS 1175 Windows and Walling Explained Martyn’s Law and Places of Worship: What a Buyer Checks for Doors and Entry Control Martyn’s Law Enhanced Tier: Physical Measures and the Specifier Brief Martyn’s Law Standard Tier: Procedures, Doors and Shutters Martyn’s Law Timeline and the SIA Regulator Martyn’s Law: what premises must do and which physical measures to consider Master Key Systems MRI and RF shielded rooms: how they work and what to specify Museum Security Doors NPSA Catalogue of Security Equipment (CSE) Explained NPSA Forced Entry and Blast Guidance for Government Sites NPSA Guidance on Lockdown and Marauding Attack: What It Asks of Doors and Entrances Office Security Doors Optician Security Doors Explained Panic Hardware PAS 24 requirements for doors and windows explained PAS 68 Bollard Foundations Explained PAS 68 bollards: ratings, spacing and cost factors PAS 68 vs IWA 14 vs ISO 22343: hostile vehicle mitigation standards explained Pawnbroker Security Doors Explained Pedestrian Gates Petrol Station Security Doors Pharmacy Security Doors Planning Permission for Security Shutters, Gates and Bollards on Commercial Premises Plant room doors: fire, security and ventilation requirements Plant Room Fire Doors Port Security Doors Post Office Security Doors Explained Powder coating vs galvanising vs paint for steel Preliminary Market Engagement for Security Doors and HVM Prison Security Doors Programming a Security Door and Barrier Package on a Live Site Public-Sector Tender Response Checklist for Security Door and HVM Supply Reading a PAS 24 and SBD Door Test Report Regulation 38 Fire Safety Information at Handover for Fire-Rated Security Doorsets Replacing Security Doors in an Occupied Building Restaurant Security Doors Retail Security Doors Revolving Doors RF shielding standards and how shielded rooms are tested Rising Bollard Cost Factors Road Blocker Cost Factors Explained Road Blockers Explained Roller Shutter Cost Factors: What Drives the Price Roller shutter regulations in the UK: safety and maintenance Safe room and panic room doors: specification basics Safety Duties for Powered Doors, Gates and Barriers on Commercial Sites School Security Doors Sectional Doors Secured by Design explained: is it mandatory for doors? Secured by Design vs NPSA vs LPCB: Which One You Need Security Door Locks Security Door Maintenance Checklist Security Doors and Access for Everyone: What Approved Document M Asks Security Doors for A and E Departments Security Doors for Badminton Clubs Security Doors for Bowling Alleys Security Doors for Bowls Clubs Security Doors for Climbing Centres Security Doors for Cricket Clubs Security Doors for Dialysis Centres Security Doors for Golf Clubs Security Doors for Hockey Clubs Security Doors for Ice Rinks Security Doors for Maternity Units Security Doors for Mental Health Units Security Doors for Oncology Units Security Doors for Operating Theatres Security Doors for Rehabilitation Centres Security Doors for Snooker Clubs Security Doors for Squash Clubs Security Doors for Swimming Pools Security Doors for Tennis Clubs Security Doors for Walk-in Centres Security Doors West Midlands Explained Security Fencing Security Gates Cost Factors Explained Security shutters vs high performance roller doors Security shutters vs retractable grilles: which suits retail and commercial openings? Security Turnstiles Explained Security Window Film Security Windows for Schools Explained Self Storage Security Doors Server Room Doors Explained Shopping Centre Security Doors Smoke Control Doors Explained Smoke Curtains Specification Mistakes When Mixing LPS 1175, PAS 24 and SBD in One Tender SR2 vs SR3 vs SR4 security doors: choosing the right LPS 1175 level Stadium Security Doors Steel Door Frames Steel vs aluminium security doors: strength, ratings and looks Steel vs timber fire doors: which suits your building? Student Accommodation Security Doors Substation doors: security, ventilation and specification Supermarket Security Doors Telescopic Bollards Tender Evaluation Criteria and Scoring for Security Doors and HVM The Scope of a Maintenance Contract for Security Doors and Barriers Theatre Security Doors Thermal and Weather Performance of External Security Doorsets Thermally broken steel security doors: U-values and certification Traffic Calming as Hostile Vehicle Mitigation Transport hub security requirements Turnstile Cost Factors Explained Turnstile vs speed gate vs security portal: choosing entrance control Types of security doors for commercial buildings University Security Doors Explained Vehicle Dynamics Assessment: What It Tells the Buyer Before a Barrier Is Specified Warehouse Security Doors Explained Warehouse Security Gates Warranty, Defects Liability and Guarantees for Security Doors and Barriers What affects the cost of a bullet resistant door What affects the cost of a high-security door in the UK Window Security Bars View all →

Products

One supplier for the whole building envelope

Ready to specify your project?

Free assessment, written specification and test evidence. Reply within one working day.