A school security door has to keep strangers out while letting hundreds of pupils move freely. Pupils arrive together in the morning and leave together in the afternoon, and the doors on that route must resist attack, release on alarm, and open for a child with a bag in each hand.
The doors are ordered by the school, the trust or the local authority, and the order names the rating, the hardware and the access control for every opening. A school holds children all day, so the doors must guard the entrance without turning the building into a place that feels locked against its own pupils.
The ratings, the hardware, the glazing and the records all sit inside that order, and an order that names them plainly is the order that gets the right doors on the right openings. Our fire door regulations for schools guide covers the fire side of the same doors, and the education sector page covers the buildings that hold pupils and researchers.
- B3 / C5 / D10LPS 1175 forced entry ratings, 3, 5 and 10 minutes
- PAS 24Enhanced security doorset test
- LPS 2081Stealth attack: SRA 1 minute, SRB 3 minutes
- EN 1627Burglar resistance classes RC1 to RC6
Entrances, classrooms and halls: where a school puts its security doors
A school divides into parts that hold pupils in different ways, and each part puts its security doors in a different place. The main entrance meets the public, the classrooms hold pupils in groups, and the halls hold the whole school together.
Every one of those parts has doors that must resist attack and doors that must release in an emergency, and the two duties sit on the same leaf. A door that resists attack but traps pupils inside has failed its other duty, and a door that releases freely but opens to any stranger has failed its first.
The rating follows the opening, not the building. A staffed main entrance faces less risk than a rear door onto a yard nobody watches after hours, so walk round the outside and note every door a person can reach, then set each one by the attack it could face. Our types of security doors guide sets out the doors a school can choose between, and the doors a university campus needs most are covered in our university security doors guide.
What B3, C5 and D10 mean on a school order
The LPS 1175 rating rests on two facts: the tools the doorset resists and the minutes it holds. Screwdrivers, pliers and hand saws are the category B tools, and three minutes against them earns B3. Crowbars, drills and chisels are the category C tools, and five minutes against them earns C5. Sledgehammers, disc cutters and jigsaws are the category D tools, and ten minutes against them earns D10. LPS 1175 Issue 8.2, dated September 2024, carries the current labels, and drawings made before the change still show the earlier ones, so read SR2 as B3, SR3 as C5 and SR4 as D10.
Match the rating to the time the school needs. Three minutes suits a door where staff or a camera will spot the attempt quickly, five minutes suits a door where the response takes longer, and ten minutes suits a door guarding high value equipment or a server room. Where many openings share the same risk, one rating can cover the whole group, and the schedule can carry them on one line, as long as each opening is named on it.
PAS 24 covers the enhanced security doorset, and a schedule that names PAS 24 beside an LPS 1175 rating has named two proofs for the same door, so each one needs its own test report behind it. The two routes are compared in our LPS 1175 vs PAS 24 guide, and our LPS 1175 page sets out the forced entry ratings in full.
Safeguarding and the locked door: keeping strangers out while pupils move freely
Safeguarding sets the first rule for a school door: a stranger must not walk in unchallenged, and a pupil must always be able to get out. The main entrance takes a controlled entry system, with a reader or an intercom and a release at the office, while the doors inside stay open to pupils during the day and lock only where the safeguarding plan names them.
A door that must also resist a quiet attack takes a second rating beside the first. LPS 2081 grades the doorset against a stealth attack, SRA for one minute and SRB for three, because the attack is quiet, not forced, and the door must hold while the attack stays unnoticed.
The lock must work from both sides without trapping a pupil inside. A thumb turn on the inside lets a child leave without a key, and a cylinder that meets TS 007, a 1-star cylinder with a 2-star handle or escutcheon giving a 3-star set, resists attack from the corridor side. Our fire door hardware guide covers the grades and the parts that make a security door work.
B3, C5 and D10 on a school order: the rating beside each door
A school door must keep strangers out and let pupils move freely, and the rating follows the room the door guards. Forced entry is proved to LPS 1175, with B3 holding three minutes against category B tools, C5 holding five minutes against category C tools and D10 holding ten minutes against category D tools, all under Issue 8.2, dated September 2024. The main entrance takes a higher grade than a classroom door, because the risk at the front of the school is greater than the risk inside it.
Safeguarding shapes every door on the site. A door that must stay locked against strangers must still open for pupils in a fire, so the lock and the release belong on the same line as the rating. The classroom door takes a lock that staff can open from the corridor and pupils can open from inside without a key, because a child must never be locked in.
One system across the site keeps the doors together, so a single card opens the buildings a member of staff uses and one stopped card stops working everywhere at once. Readers, fobs and the power cut belong on the order beside the leaf, because a door that needs power to open is no door at all in a blackout. The lanes and readers at the staff entrance are covered in our security turnstiles guide.
Fire and security share the school door where the room needs both. A door that must hold fire takes FD30 or FD60 proved to EN 1634-1, and the forced entry proof sits beside it on the same schedule line, each proved on its own test. The guide on dual certification works through how the two proofs share one leaf.
The boundary before the door: gates, fences and the school line
Glazed doors and screens give a school the sightlines it cannot do without. Staff must see the corridor, the hall and the playground from the door, so the glass must be proved for the job, because a pane that was never tested is a hole in the door, whatever the leaf around it can hold.
Gates and fences stand in front of the doors, and they close the line a stranger could walk through. The pedestrian gate takes a reader and a lock, while the vehicle gate takes a motor and a release on alarm, and each must hold the same proof as the fence beside it, because the gate is the hole in the line. The rated options for the gate line are covered in our anti-ram gates and barriers guide, and the fencing that holds a vehicle is covered in our crash rated fences and HVM fencing guide.
The inspection routine walks the site once a month and looks at every door, gate and reader in turn. A closer that no longer pulls the leaf shut, a reader that no longer opens the gate, or a seal that has come away each gets written down the same day, with the building and the fault beside it, so the repair follows the fault and the school never stands open.
| Area | Rating | Access | What to check |
|---|---|---|---|
| Main entrance | LPS 1175 C5 | Reader, intercom | Lock, closer, release |
| Classroom corridor | LPS 1175 B3 | Reader | Closer, seals, latch |
| Hall | FD30 + B3 | Reader | Panic bar, seals, release |
| Boundary gate | LPS 1175 B3 | Reader, motor | Lock, hinges, release |
Name the grade, the reader and the release beside each school door on the order, so the door that arrives is the door that was tested. The periods for the shared parts of a building are set out in our commercial buildings fire door regulations guide.
One system across the site: readers, fobs and the power cut
A school site holds several buildings, and the access control must work as one system across them all. A card or fob that opens the main entrance should open the classroom block and the sports hall, and a card that is lost should stop working everywhere at once.
The system must fail safe when the power goes. A door that locks shut in a power cut traps pupils inside, so the release on alarm and the release on power failure belong in the specification beside the reader. Our security turnstiles guide covers how readers, fobs and biometrics are wired into the lane.
Gates carry the same discipline to the boundary. A pedestrian gate that opens for a pupil must close behind them, and a vehicle gate must hold against a vehicle that tries the line. Our gate automation guide covers how a gate is driven and released.
Fire and security on one doorset: two proofs, one leaf
Many school doors must hold fire as well as resist attack, and the two proofs sit on the one doorset. The fire side is proved to EN 1634-1, with FD30 for 30 minutes and FD60 for 60, and the letters before the number say what the test measured: E for integrity, EW for integrity with limited radiation, and EI for integrity with insulation.
Smoke moves along a corridor faster than flame, so a door on a smoke path needs a seal as well as a period. FD30S pairs 30 minutes of integrity with a smoke seal proved to BS EN 1634-3, to Sa or S200, and the seal only works where the gap around the leaf is right. Hold the gaps at 4 mm, because a seal cannot hold smoke back where the gap is wide, and intumescent seals expand at roughly 200 to 250 degrees to close the gap as the heat builds. Our dual certification guide works through how the two proofs sit on one doorset.
An escape door must release in one action, with no key in the way. Panic hardware to BS EN 1125 belongs on a door that serves more than 60 people, with its bar running across at least 60 percent of the leaf width. BS 8300 and Approved Document M cap the opening force: below 30 N through the first 30 degrees and below 22.5 N beyond that.
Glazed doors and screens: sightlines a school cannot do without
Glazing on a school door lets staff see who is on the other side before the door opens, and a glazed door or screen must hold attack as well as light. A rated pane in an untested frame is not a rated screen, because the glass, the frame, the beads and the fixings are tested together.
Windows in a school take the same discipline. Ground floor glass faces the most risk, and a pane that must stop a hand tool takes a rating to EN 356, from P1A to P8B, with the top classes set by axe blows: P6B takes 30 to 50, P7B 51 to 70 and P8B 70 or more. Our security windows for schools guide sets out the glass a school needs.
Where a glazed screen must also resist attack, a second rating sits beside the fire rating, with one assembly tested for both. The forced entry side follows LPS 1175, with B3, C5 and D10 for three, five and ten minutes, and the old labels SR2, SR3 and SR4 read as B3, C5 and D10 in that order.
Gates, fences and the boundary: the line before the door
The boundary is the first line a school holds, and the gates on it carry the same ratings as the doors behind them. A pedestrian gate that opens for pupils must close behind them, and a vehicle gate must hold against a vehicle that tries the line. ISO 22343-1 tests a barrier against a moving vehicle: the mass, the speed, the angle and how far the vehicle travels past the line.
ISO 22343-1:2023 supersedes PAS 68:2013, and a schedule that names the old standard by quoting the new one has asked for something that does not exist. Name the standard beside the product it belongs to, and the rating beside the standard. ProtectUK guidance for hostile vehicle mitigation names a 1,200 mm maximum clear gap and a 500 mm minimum height for a barrier line.
The changes that void a rating are set out in our keeping an LPS 1175 rating valid guide. A gate leaf that sags, a hinge that drops or a closer that cannot shut the leaf all break the rating the doorset was given, and the door needs repair or replacement, not a note in the file.
The school order: one schedule for every building
Build the enquiry as a specification. Each line names the building and the position, the forced entry rating and the fire period, the access control and the hardware, and the leaf, frame, glass, beads, seals and hardware as one doorset. For a door that must resist attack, ask for the evidence on the whole doorset, a rating to LPS 1175 or PAS 24, not a rating for the leaf alone. The same discipline column by column is in our how to specify security doors guide.
File the evidence with the doors on the day they arrive. The test report, the classification and the hardware schedule should travel with each doorset, and the handover pack should name the inspection routine the site will follow.
| Door position | Rating | Hardware | What to check |
|---|---|---|---|
| Main entrance | B3 or PAS 24 | Reader, intercom, release | Access control, fail safe, seals |
| Classroom door | B3 | Thumb turn, TS 007 cylinder | Latch, closer, glazing |
| Hall door | C5 | Panic hardware, closer EN 3 or above | Panic bar, opening force |
| Server room door | D10 | Closer, latch, seals | Seals, gaps, self-closing |
| Site gate | LPS 1175 or ISO 22343-1 | Automation, release on alarm | Hinges, closer, release |
A school door guards children, so the release on alarm matters as much as the rating on the schedule.
What security rating should a school entrance door carry?
Most often B3 or PAS 24, with the rating set by the risk the opening faces. A rear door onto an unwatched yard usually takes a higher rating than a staffed main entrance.
Can one school door hold a fire rating and a security rating?
Yes, where one doorset is tested for both jobs. The fire side is proved to EN 1634-1 and the forced entry side to LPS 1175 or PAS 24, and both pieces of evidence must name the doorset being fitted.
Do school hall doors need panic hardware?
Yes, where more than 60 people use the door. Panic hardware to BS EN 1125 belongs on it, with the bar spanning at least 60 percent of the leaf.
What happens to school access control in a power cut?
The system must fail safe, releasing the doors so pupils can leave. The release on alarm and the release on power failure belong in the specification beside the reader.
How do I order doors for a whole school site?
Write one schedule with one line for every opening, naming the building, the position, the rating, the fire period, the access control and the whole doorset.
For a building with more than one opening, our enquiry checklist for security doors sets out the rating, hardware and evidence to name for each door.