Security door rules for schools: rated entrances, safeguarding and access control across classrooms, halls and the site boundary, on one schedule.

  • ✓Third-party test evidence with every product
  • ✓Written specification you can issue to tender
  • ✓Supplied and installed across the UK
Prefer to talk?+44 7352 267239

Get a free project quote

Rating, written specification and budget range within one working day.

ArxBridge Quote Form

Confidential. No cost, no obligation.

Third-party tested

Evidence with every quote

UK manufactured

Made to your sizes

One accountable team

Specify, supply, install

Confidential handling

Details never shared

A school security door has to keep strangers out while letting hundreds of pupils move freely. Pupils arrive together in the morning and leave together in the afternoon, and the doors on that route must resist attack, release on alarm, and open for a child with a bag in each hand.

The doors are ordered by the school, the trust or the local authority, and the order names the rating, the hardware and the access control for every opening. A school holds children all day, so the doors must guard the entrance without turning the building into a place that feels locked against its own pupils.

The ratings, the hardware, the glazing and the records all sit inside that order, and an order that names them plainly is the order that gets the right doors on the right openings. Our fire door regulations for schools guide covers the fire side of the same doors, and the education sector page covers the buildings that hold pupils and researchers.

  • B3 / C5 / D10LPS 1175 forced entry ratings, 3, 5 and 10 minutes
  • PAS 24Enhanced security doorset test
  • LPS 2081Stealth attack: SRA 1 minute, SRB 3 minutes
  • EN 1627Burglar resistance classes RC1 to RC6

Entrances, classrooms and halls: where a school puts its security doors

A school divides into parts that hold pupils in different ways, and each part puts its security doors in a different place. The main entrance meets the public, the classrooms hold pupils in groups, and the halls hold the whole school together.

Every one of those parts has doors that must resist attack and doors that must release in an emergency, and the two duties sit on the same leaf. A door that resists attack but traps pupils inside has failed its other duty, and a door that releases freely but opens to any stranger has failed its first.

The rating follows the opening, not the building. A staffed main entrance faces less risk than a rear door onto a yard nobody watches after hours, so walk round the outside and note every door a person can reach, then set each one by the attack it could face. Our types of security doors guide sets out the doors a school can choose between, and the doors a university campus needs most are covered in our university security doors guide.

What B3, C5 and D10 mean on a school order

The LPS 1175 rating rests on two facts: the tools the doorset resists and the minutes it holds. Screwdrivers, pliers and hand saws are the category B tools, and three minutes against them earns B3. Crowbars, drills and chisels are the category C tools, and five minutes against them earns C5. Sledgehammers, disc cutters and jigsaws are the category D tools, and ten minutes against them earns D10. LPS 1175 Issue 8.2, dated September 2024, carries the current labels, and drawings made before the change still show the earlier ones, so read SR2 as B3, SR3 as C5 and SR4 as D10.

Match the rating to the time the school needs. Three minutes suits a door where staff or a camera will spot the attempt quickly, five minutes suits a door where the response takes longer, and ten minutes suits a door guarding high value equipment or a server room. Where many openings share the same risk, one rating can cover the whole group, and the schedule can carry them on one line, as long as each opening is named on it.

PAS 24 covers the enhanced security doorset, and a schedule that names PAS 24 beside an LPS 1175 rating has named two proofs for the same door, so each one needs its own test report behind it. The two routes are compared in our LPS 1175 vs PAS 24 guide, and our LPS 1175 page sets out the forced entry ratings in full.

Need this specified for your project?Free rating, written specification and budget range within one working day.
Get a free quote

Safeguarding and the locked door: keeping strangers out while pupils move freely

Safeguarding sets the first rule for a school door: a stranger must not walk in unchallenged, and a pupil must always be able to get out. The main entrance takes a controlled entry system, with a reader or an intercom and a release at the office, while the doors inside stay open to pupils during the day and lock only where the safeguarding plan names them.

A door that must also resist a quiet attack takes a second rating beside the first. LPS 2081 grades the doorset against a stealth attack, SRA for one minute and SRB for three, because the attack is quiet, not forced, and the door must hold while the attack stays unnoticed.

The lock must work from both sides without trapping a pupil inside. A thumb turn on the inside lets a child leave without a key, and a cylinder that meets TS 007, a 1-star cylinder with a 2-star handle or escutcheon giving a 3-star set, resists attack from the corridor side. Our fire door hardware guide covers the grades and the parts that make a security door work.

B3, C5 and D10 on a school order: the rating beside each door

A school door must keep strangers out and let pupils move freely, and the rating follows the room the door guards. Forced entry is proved to LPS 1175, with B3 holding three minutes against category B tools, C5 holding five minutes against category C tools and D10 holding ten minutes against category D tools, all under Issue 8.2, dated September 2024. The main entrance takes a higher grade than a classroom door, because the risk at the front of the school is greater than the risk inside it.

Safeguarding shapes every door on the site. A door that must stay locked against strangers must still open for pupils in a fire, so the lock and the release belong on the same line as the rating. The classroom door takes a lock that staff can open from the corridor and pupils can open from inside without a key, because a child must never be locked in.

One system across the site keeps the doors together, so a single card opens the buildings a member of staff uses and one stopped card stops working everywhere at once. Readers, fobs and the power cut belong on the order beside the leaf, because a door that needs power to open is no door at all in a blackout. The lanes and readers at the staff entrance are covered in our security turnstiles guide.

Fire and security share the school door where the room needs both. A door that must hold fire takes FD30 or FD60 proved to EN 1634-1, and the forced entry proof sits beside it on the same schedule line, each proved on its own test. The guide on dual certification works through how the two proofs share one leaf.

The boundary before the door: gates, fences and the school line

Glazed doors and screens give a school the sightlines it cannot do without. Staff must see the corridor, the hall and the playground from the door, so the glass must be proved for the job, because a pane that was never tested is a hole in the door, whatever the leaf around it can hold.

Gates and fences stand in front of the doors, and they close the line a stranger could walk through. The pedestrian gate takes a reader and a lock, while the vehicle gate takes a motor and a release on alarm, and each must hold the same proof as the fence beside it, because the gate is the hole in the line. The rated options for the gate line are covered in our anti-ram gates and barriers guide, and the fencing that holds a vehicle is covered in our crash rated fences and HVM fencing guide.

The inspection routine walks the site once a month and looks at every door, gate and reader in turn. A closer that no longer pulls the leaf shut, a reader that no longer opens the gate, or a seal that has come away each gets written down the same day, with the building and the fault beside it, so the repair follows the fault and the school never stands open.

Area Rating Access What to check
Main entrance LPS 1175 C5 Reader, intercom Lock, closer, release
Classroom corridor LPS 1175 B3 Reader Closer, seals, latch
Hall FD30 + B3 Reader Panic bar, seals, release
Boundary gate LPS 1175 B3 Reader, motor Lock, hinges, release

Name the grade, the reader and the release beside each school door on the order, so the door that arrives is the door that was tested. The periods for the shared parts of a building are set out in our commercial buildings fire door regulations guide.

One system across the site: readers, fobs and the power cut

A school site holds several buildings, and the access control must work as one system across them all. A card or fob that opens the main entrance should open the classroom block and the sports hall, and a card that is lost should stop working everywhere at once.

The system must fail safe when the power goes. A door that locks shut in a power cut traps pupils inside, so the release on alarm and the release on power failure belong in the specification beside the reader. Our security turnstiles guide covers how readers, fobs and biometrics are wired into the lane.

Gates carry the same discipline to the boundary. A pedestrian gate that opens for a pupil must close behind them, and a vehicle gate must hold against a vehicle that tries the line. Our gate automation guide covers how a gate is driven and released.

Fire and security on one doorset: two proofs, one leaf

Many school doors must hold fire as well as resist attack, and the two proofs sit on the one doorset. The fire side is proved to EN 1634-1, with FD30 for 30 minutes and FD60 for 60, and the letters before the number say what the test measured: E for integrity, EW for integrity with limited radiation, and EI for integrity with insulation.

Smoke moves along a corridor faster than flame, so a door on a smoke path needs a seal as well as a period. FD30S pairs 30 minutes of integrity with a smoke seal proved to BS EN 1634-3, to Sa or S200, and the seal only works where the gap around the leaf is right. Hold the gaps at 4 mm, because a seal cannot hold smoke back where the gap is wide, and intumescent seals expand at roughly 200 to 250 degrees to close the gap as the heat builds. Our dual certification guide works through how the two proofs sit on one doorset.

An escape door must release in one action, with no key in the way. Panic hardware to BS EN 1125 belongs on a door that serves more than 60 people, with its bar running across at least 60 percent of the leaf width. BS 8300 and Approved Document M cap the opening force: below 30 N through the first 30 degrees and below 22.5 N beyond that.

Glazed doors and screens: sightlines a school cannot do without

Glazing on a school door lets staff see who is on the other side before the door opens, and a glazed door or screen must hold attack as well as light. A rated pane in an untested frame is not a rated screen, because the glass, the frame, the beads and the fixings are tested together.

Windows in a school take the same discipline. Ground floor glass faces the most risk, and a pane that must stop a hand tool takes a rating to EN 356, from P1A to P8B, with the top classes set by axe blows: P6B takes 30 to 50, P7B 51 to 70 and P8B 70 or more. Our security windows for schools guide sets out the glass a school needs.

Where a glazed screen must also resist attack, a second rating sits beside the fire rating, with one assembly tested for both. The forced entry side follows LPS 1175, with B3, C5 and D10 for three, five and ten minutes, and the old labels SR2, SR3 and SR4 read as B3, C5 and D10 in that order.

Gates, fences and the boundary: the line before the door

The boundary is the first line a school holds, and the gates on it carry the same ratings as the doors behind them. A pedestrian gate that opens for pupils must close behind them, and a vehicle gate must hold against a vehicle that tries the line. ISO 22343-1 tests a barrier against a moving vehicle: the mass, the speed, the angle and how far the vehicle travels past the line.

ISO 22343-1:2023 supersedes PAS 68:2013, and a schedule that names the old standard by quoting the new one has asked for something that does not exist. Name the standard beside the product it belongs to, and the rating beside the standard. ProtectUK guidance for hostile vehicle mitigation names a 1,200 mm maximum clear gap and a 500 mm minimum height for a barrier line.

The changes that void a rating are set out in our keeping an LPS 1175 rating valid guide. A gate leaf that sags, a hinge that drops or a closer that cannot shut the leaf all break the rating the doorset was given, and the door needs repair or replacement, not a note in the file.

The school order: one schedule for every building

Build the enquiry as a specification. Each line names the building and the position, the forced entry rating and the fire period, the access control and the hardware, and the leaf, frame, glass, beads, seals and hardware as one doorset. For a door that must resist attack, ask for the evidence on the whole doorset, a rating to LPS 1175 or PAS 24, not a rating for the leaf alone. The same discipline column by column is in our how to specify security doors guide.

File the evidence with the doors on the day they arrive. The test report, the classification and the hardware schedule should travel with each doorset, and the handover pack should name the inspection routine the site will follow.

Door position Rating Hardware What to check
Main entrance B3 or PAS 24 Reader, intercom, release Access control, fail safe, seals
Classroom door B3 Thumb turn, TS 007 cylinder Latch, closer, glazing
Hall door C5 Panic hardware, closer EN 3 or above Panic bar, opening force
Server room door D10 Closer, latch, seals Seals, gaps, self-closing
Site gate LPS 1175 or ISO 22343-1 Automation, release on alarm Hinges, closer, release

A school door guards children, so the release on alarm matters as much as the rating on the schedule.

What security rating should a school entrance door carry?

Most often B3 or PAS 24, with the rating set by the risk the opening faces. A rear door onto an unwatched yard usually takes a higher rating than a staffed main entrance.

Can one school door hold a fire rating and a security rating?

Yes, where one doorset is tested for both jobs. The fire side is proved to EN 1634-1 and the forced entry side to LPS 1175 or PAS 24, and both pieces of evidence must name the doorset being fitted.

Do school hall doors need panic hardware?

Yes, where more than 60 people use the door. Panic hardware to BS EN 1125 belongs on it, with the bar spanning at least 60 percent of the leaf.

What happens to school access control in a power cut?

The system must fail safe, releasing the doors so pupils can leave. The release on alarm and the release on power failure belong in the specification beside the reader.

How do I order doors for a whole school site?

Write one schedule with one line for every opening, naming the building, the position, the rating, the fire period, the access control and the whole doorset.

For a building with more than one opening, our enquiry checklist for security doors sets out the rating, hardware and evidence to name for each door.

Specifying security doors for a school?Send the door schedule and the safeguarding plan for a tested doorset quotation.
Get a free quote

Related

More in guides for specifiers

10 mistakes when specifying certified security doors 10 steps to specify an LPS 1175 door Acceptance and Snagging of a Security Door or Barrier Job Access Control Doors Acoustic Doors: Ratings and Specification After a Forced Entry Attempt: Checking a Security Door Airport Security Doors Anti-Ligature Doors for Mental Health Wards Anti-Ram Bollards Anti-ram gates and barriers: protecting vehicle entrances Arcade Security Doors Explained Automatic Doors Automatic Gates Cost Factors Automatic Vehicle Barriers Ballistic Panels Bank Security Doors Bingo Hall Security Doors Explained Blast doors: glazed vs solid and how they are rated Blast protection window film: what it does and what it cannot do Blast resistant windows: what drives the cost and how to specify them Bollard Cost Factors Explained Bollard regulations in the UK: spacing, height and depth Bookmaker Security Doors Explained Builders Merchant Security Doors Bullet Resistant Glass Cost Factors Bullet resistant glass ratings explained: BR1 to BR7 and SG classes Bullet resistant vs bulletproof glass: what the difference means Buying Security Doors and HVM Through Public Frameworks Car Park Security Doors Explained Car Showroom Security Doors Casino Security Doors Explained CDM 2015 Duties When Security Doors, Shutters or HVM Are Installed Cinema Security Doors Cleanroom Doors Cold Store Doors College Security Doors Commissioning, Handover and the O&M Manual for Security Doors and HVM Communal entrance doors for flats: Secured by Design and what to specify Community Centre Security Doors Control Room Doors Court Security Doors Crash Rated Fences and HVM Fencing Explained Data centre physical security: doors, glazing, HVM and shielding by zone Dental Practice Security Doors Depot Security Doors Explained Door Entry Systems Due Diligence When Selecting Vehicle Security Barriers Emergency Exit Doors EMP Shielding Cost Factors Explained Exhibition Centre Fire Door Rules Exhibition Centre Security Doors Factory Security Doors Faraday cage vs RF shielded room: what a business needs FB4 vs FB6 vs FB7: how to choose a ballistic rating Fire and security doors: how dual certification works Fire Compartmentation Fire Curtains Fire Door Certification Fire Door Closers Explained Fire Door Cost Factors Fire Door Duties of the Accountable Person Fire Door Gaps Fire Door Hardware Explained Fire door inspection checklist for steel and timber doors Fire Door Maintenance Fire Door Regulations Care Homes Fire Door Regulations for A and E Departments Fire Door Regulations for Airports Explained Fire Door Regulations for Bowls Clubs Fire door regulations for commercial buildings in the UK Fire Door Regulations for Dialysis Centres Fire Door Regulations for Hockey Clubs Fire Door Regulations for Hospitals Explained Fire Door Regulations for Offices Explained Fire Door Regulations for Operating Theatres Fire Door Regulations for Retail Explained Fire Door Regulations for Schools Explained Fire Door Regulations for Snooker Clubs Fire Door Regulations for Stadiums Fire Door Regulations for Student Accommodation Fire Door Regulations for Warehouses Fire Door Regulations Leisure Centres Fire Door Regulations Restaurants Fire Door Remediation Programme for Housing Providers Fire Door Rules for Badminton Clubs Fire Door Rules for Bingo Halls Fire Door Rules for Bookmakers Fire Door Rules for Bowling Alleys Fire Door Rules for Car Parks Fire Door Rules for Car Showrooms Fire Door Rules for Cinemas Fire Door Rules for Climbing Centres Fire Door Rules for Colleges Fire Door Rules for Community Centres Fire Door Rules for Cricket Clubs Fire Door Rules for Dental Practices Fire Door Rules for Depots Explained Fire Door Rules for Golf Clubs Fire Door Rules for GP Surgeries Fire Door Rules for Gyms Explained Fire Door Rules for Ice Rinks Fire Door Rules for Maternity Units Fire Door Rules for Mental Health Units Fire Door Rules for Museums Fire Door Rules for Oncology Units Fire Door Rules for Opticians Fire Door Rules for Pawnbrokers Fire Door Rules for Petrol Stations Fire Door Rules for Pharmacies Fire Door Rules for Ports Fire Door Rules for Post Offices Fire Door Rules for Prisons Fire Door Rules for Rehabilitation Centres Fire Door Rules for Self Storage Fire Door Rules for Shopping Centres Fire Door Rules for Squash Clubs Fire Door Rules for Supermarkets Fire Door Rules for Swimming Pools Fire Door Rules for Tennis Clubs Fire Door Rules for Theatres Fire Door Rules for UK Arcades Fire Door Rules for UK Casinos Fire Door Rules for UK Hospices Fire Door Rules for Walk-in Centres Fire Door Signage Fire Door Vision Panels Fire Doors and Gateway 2 in Higher-Risk Buildings Fire Rated Glass Cost Explained Fire Rated Sliding Doors Explained Fire Rated Windows Cost Factors Fire Rated Windows Explained Fire Safety Enforcement Notices and Fire Doors: What the Responsible Person Must Do Flat Entrance Doors: PAS 24 and Fire Rated Forced Entry vs Ballistic vs Blast: Which Rating a Site Needs Garage Security Doors Explained Gate Automation Explained Golden Thread Records for Fire Doors GP Surgery Security Doors Explained Gym Security Doors Explained High Speed Doors HMO Fire Doors Hospice Security Doors Explained Hospital Security Doors: Wards, A&E, Plant Hospital Security Gates Hotel Fire Doors Hotel Security Doors How to choose HVM bollards: fixed, shallow mount, removable and automatic How to keep an LPS 1175 door rating valid after installation How to Specify Fire Doors in a Housing Tender How to specify security doors: a checklist for architects How to Verify a Secured by Design Listing How to Verify an LPS 1175 Certificate on Red Book Live How to Write an Operational Requirement for Physical Security HVM planters and street furniture: protection that blends in In-Service Care of Vehicle Security Barriers Installation Handover: LPS 1175 Doors and PAS 68 Barriers Intumescent Seals ISO 16933 explained: EXV and SB classes and hazard ratings ISO 22343 vehicle security barriers explained Keeping a Dual-Certified Fire and Security Door Valid in Service Laboratory Security Doors Layered Security for a Site: Deter, Detect, Delay, Mitigate, Respond Lead Times and Programme Risks for LPS 1175 Doors Leisure Centre Security Doors Library Security Doors Listed Building Fire Doors Loading Bay Doors Explained Lockdown and Access Control Hardware on an LPS 1175 Door LPS 1175 Gates and Grilles Explained LPS 1175 Issue 8 explained: from SR1 to SR8 to A1 to H20 LPS 1175 Roller Shutters LPS 1175 vs ASTM F2781 and Other US Ratings Explained LPS 1175 vs EN 1627: how UK and European burglar resistance ratings compare LPS 1175 vs PAS 24: which security standard does your door need? LPS 1175 Windows and Walling Explained Martyn’s Law and Places of Worship: What a Buyer Checks for Doors and Entry Control Martyn’s Law Enhanced Tier: Physical Measures and the Specifier Brief Martyn’s Law Standard Tier: Procedures, Doors and Shutters Martyn’s Law Timeline and the SIA Regulator Martyn’s Law: what premises must do and which physical measures to consider Master Key Systems MRI and RF shielded rooms: how they work and what to specify Museum Security Doors NPSA Catalogue of Security Equipment (CSE) Explained NPSA Forced Entry and Blast Guidance for Government Sites NPSA Guidance on Lockdown and Marauding Attack: What It Asks of Doors and Entrances Office Security Doors Optician Security Doors Explained Panic Hardware PAS 24 requirements for doors and windows explained PAS 68 Bollard Foundations Explained PAS 68 bollards: ratings, spacing and cost factors PAS 68 vs IWA 14 vs ISO 22343: hostile vehicle mitigation standards explained Pawnbroker Security Doors Explained Pedestrian Gates Petrol Station Security Doors Pharmacy Security Doors Planning Permission for Security Shutters, Gates and Bollards on Commercial Premises Plant room doors: fire, security and ventilation requirements Plant Room Fire Doors Port Security Doors Post Office Security Doors Explained Powder coating vs galvanising vs paint for steel Preliminary Market Engagement for Security Doors and HVM Prison Security Doors Programming a Security Door and Barrier Package on a Live Site Public-Sector Tender Response Checklist for Security Door and HVM Supply Reading a PAS 24 and SBD Door Test Report Regulation 38 Fire Safety Information at Handover for Fire-Rated Security Doorsets Replacing Security Doors in an Occupied Building Restaurant Security Doors Retail Security Doors Revolving Doors RF shielding standards and how shielded rooms are tested Rising Bollard Cost Factors Road Blocker Cost Factors Explained Road Blockers Explained Roller Shutter Cost Factors: What Drives the Price Roller shutter regulations in the UK: safety and maintenance Safe room and panic room doors: specification basics Safety Duties for Powered Doors, Gates and Barriers on Commercial Sites Sectional Doors Secured by Design explained: is it mandatory for doors? Secured by Design vs NPSA vs LPCB: Which One You Need Security Door Locks Security Door Maintenance Checklist Security Doors and Access for Everyone: What Approved Document M Asks Security Doors for A and E Departments Security Doors for Badminton Clubs Security Doors for Bowling Alleys Security Doors for Bowls Clubs Security Doors for Climbing Centres Security Doors for Cricket Clubs Security Doors for Dialysis Centres Security Doors for Golf Clubs Security Doors for Hockey Clubs Security Doors for Ice Rinks Security Doors for Maternity Units Security Doors for Mental Health Units Security Doors for Oncology Units Security Doors for Operating Theatres Security Doors for Rehabilitation Centres Security Doors for Snooker Clubs Security Doors for Squash Clubs Security Doors for Swimming Pools Security Doors for Tennis Clubs Security Doors for Walk-in Centres Security Doors West Midlands Explained Security Fencing Security Gates Cost Factors Explained Security shutters vs high performance roller doors Security shutters vs retractable grilles: which suits retail and commercial openings? Security Turnstiles Explained Security Window Film Security Windows for Schools Explained Self Storage Security Doors Server Room Doors Explained Shopping Centre Security Doors Smoke Control Doors Explained Smoke Curtains Specification Mistakes When Mixing LPS 1175, PAS 24 and SBD in One Tender SR2 vs SR3 vs SR4 security doors: choosing the right LPS 1175 level Stadium Security Doors Steel Door Frames Steel vs aluminium security doors: strength, ratings and looks Steel vs timber fire doors: which suits your building? Student Accommodation Security Doors Substation doors: security, ventilation and specification Supermarket Security Doors Telescopic Bollards Tender Evaluation Criteria and Scoring for Security Doors and HVM The Scope of a Maintenance Contract for Security Doors and Barriers Theatre Security Doors Thermal and Weather Performance of External Security Doorsets Thermally broken steel security doors: U-values and certification Traffic Calming as Hostile Vehicle Mitigation Transport hub security requirements Turnstile Cost Factors Explained Turnstile vs speed gate vs security portal: choosing entrance control Types of security doors for commercial buildings University Security Doors Explained Vehicle Dynamics Assessment: What It Tells the Buyer Before a Barrier Is Specified Warehouse Security Doors Explained Warehouse Security Gates Warranty, Defects Liability and Guarantees for Security Doors and Barriers What affects the cost of a bullet resistant door What affects the cost of a high-security door in the UK Window Security Bars View all →