University Security Doors Explained

What a university estate needs from its doors: halls, lecture buildings, libraries and entrances, fire and forced entry on one doorset, access control at scale.

  • ✓Third-party test evidence with every product
  • ✓Written specification you can issue to tender
  • ✓Supplied and installed across the UK
Prefer to talk?+44 7352 267239

Get a free project quote

Rating, written specification and budget range within one working day.

ArxBridge Quote Form

Confidential. No cost, no obligation.

Third-party tested

Evidence with every quote

UK manufactured

Made to your sizes

One accountable team

Specify, supply, install

Confidential handling

Details never shared

A university buys doors by the estate. One order covers halls of residence, lecture buildings, libraries, laboratories, sports halls and the entrances between them, and each building asks its doors to do a different job. A hall door must hold fire in a corridor where students sleep, a lecture building door must take a crowd between lectures, a library door must close quietly behind readers, and an entrance door must admit hundreds of people in a few minutes and still keep strangers out. The specification that serves a campus names the rating, the hardware and the evidence for each opening, and it names them together, because a door that holds fire but fails a forced entry test, or a door that resists attack but stands open all day, has not done the job it was bought for.

The law that shapes the order is the Regulatory Reform (Fire Safety) Order 2005, which names a responsible person for the premises, and on a campus that duty sits with the university as the occupier of its own buildings, with the estates team carrying the day to day work. Where a building is leased, the lease divides the duty, and the boundary should be written down in the fire risk assessment. The fire strategy names the rating for each opening, FD30 or FD60 tested to EN 1634-1, and the security requirement names the forced entry rating beside it, so one doorset carries both jobs where the opening needs both.

Our types of security doors guide sets out the range of doors a campus may need, and our how to specify security doors guide covers the discipline of naming the performance in full. Our education sector page covers the buildings a campus holds. The sections below work through the buildings one by one, then the entrance, then the two ratings on one assembly, then access control and the order itself.

  • FD30 / FD60Fire resistance periods tested to EN 1634-1
  • LPS 1175Forced entry rating, B3 to D10
  • PAS 24Enhanced security doorset standard
  • BS EN 1154Closer power sizes, minimum EN 3 on fire doors

A campus is a set of buildings, not one door

A campus holds more kinds of door than most towns. Halls of residence sleep hundreds of students behind doors that must close and latch every night. Lecture buildings move crowds through wide doors in the minutes between lectures. Libraries need doors that close quietly and still hold a compartment line. Laboratories, plant rooms and stores need doors that hold a higher risk fire inside its own room. The entrance buildings need doors and lanes that admit students and staff and keep strangers out. One specification cannot cover all of them, and a campus that orders one door type for every opening will have doors that fail in different ways in different buildings.

The answer is a door schedule with one line per opening. Each line names the building, the position, the fire rating, the security rating where one is needed, the leaf, the frame, the glass, the seals and the hardware as one doorset. Our how to specify security doors guide works through the schedule column by column, and the same habit serves a campus: write the schedule first, then order against it, so every door is bought for the opening it stands in.

The schedule should be built building by building, with the estates team, the fire risk assessor and the security team reading it together. A hall door that the fire risk assessor wants to hold fire for 30 minutes and the security team wants to resist a forced entry needs both ratings on the same assembly, and the schedule is where that double requirement is written down. A door ordered without the schedule is a door ordered on a guess, and a campus that files the schedule with the building records has a record it can use for the whole life of the estate.

Halls of residence: the door between a student and the corridor

A hall door is the door a student sleeps behind, and it carries the heaviest fire duty on a campus. The corridor outside a student room is the escape route for everyone on that floor, so the door must hold fire and smoke inside the room while the corridor fills with people leaving. A door marked FD30S carries 30 minutes of integrity plus smoke control, tested to BS EN 1634-3, and the S must be named in the specification where the fire strategy needs it. A fire rating on its own does not prove smoke control, so ask for the smoke evidence by name.

The closer is the part that decides whether the door works. A closer sized to BS EN 1154 for the leaf weight will close the leaf and hold the latch every time, but a closer that has been adjusted by hand, a closer with a leaking body, or a closer taken off because it was too stiff, will leave the leaf standing open. A door that does not close has no fire performance, whatever its certificate says. Our fire door closers guide sets out the power sizes in BS EN 1154 and how to read them, and the minimum power size on a fire door is EN 3.

Students wedge doors open. They do it for a delivery, for a friend, for air, and for the same reason anyone wedges a door open: the door is in the way. A hall door that must stand open needs a hold-open device to BS EN 1155 that releases the door when the alarm sounds, not a wedge. Seals and gaps are the small parts that decide the rating. A 4 mm gap around the leaf is the usual limit, and intumescent seals close the gap in a fire, expanding at roughly 200 to 250 degrees. Our fire door hardware guide sets out the hardware set, hinges, seals and latches included, and our flat entrance doors guide covers the door that guards a room where someone sleeps, which is the closest analogue to a student room door.

Need this specified for your project?Free rating, written specification and budget range within one working day.
Get a free quote

Lecture buildings: crowds between lectures and the doors that must take them

A lecture building moves its whole population twice an hour. Hundreds of students leave one theatre and hundreds more arrive for the next, and the doors between the corridor and the theatre must take that crowd without slowing it and without failing. The doors must open in the direction of escape, and they must open in one action without a key, because a crowd under pressure cannot queue for a lock. Panic hardware to BS EN 1125 belongs on these doors, with a bar across the leaf covering at least 60 percent of the leaf width, and the same hardware belongs on any escape door where more than 60 people leave under pressure. Our fire door regulations for schools guide covers classrooms, corridors and halls where doors must work differently, and a lecture building asks the same of its doors at a larger scale.

Opening force matters on a lecture building door as much as on any other. A door must open with less than 30 N in the first 30 degrees and less than 22.5 N beyond that, under BS 8300 and Approved Document M, because students push through these doors with bags, books and laptops in their hands all day. A closer that is too strong for the leaf makes the door fail the access rules and invites staff to wedge it open. Hinges to BS EN 1935 carry the leaf, grade 13 or grade 14, and a hinge that has dropped lets the leaf sag, so the closer cannot close it squarely.

Vision panels matter in a lecture building. A door with a glazed panel lets a lecturer see whether the theatre is full before opening it, and lets students see whether the corridor is clear before they leave. The glass must carry the same fire rating as the leaf, with beads and seals tested as part of the doorset, because a panel that fails early breaks the compartment line at the very point people look through.

Libraries and study spaces: quiet rooms behind doors that must still close

A library door must close quietly and still hold a compartment line. Readers sit for hours behind these doors, and a door that slams, drags or sticks will be wedged open within a week. The closer must be set so the leaf closes and latches without a slam, and the latch must hold without a push. A door that needs a shove to latch will stand ajar, and a door that stands ajar has no fire performance.

Library stores hold the books and archives the university cannot replace, and the doors to those stores need a higher rating than the reading room doors. Plant rooms, server rooms and stores commonly carry FD60, because the people and the contents behind them need more time. Our server room doors guide covers the doors that guard rooms full of equipment, and the same discipline applies to a library store: name the rating the fire strategy asks for, and order the leaf, the frame, the seals and the hardware as one doorset.

Study spaces change use through the day. A room that holds a seminar in the morning holds silent study in the afternoon, and the doors must serve both without being changed. A door with a hold-open device to BS EN 1155 can stand open for the seminar and still close when the alarm sounds, so the room can change use without the door losing its fire performance. A wedge, a chair or a hook on the wall has no such release, and a door held open by one of those will stand open in a fire.

Entrances that admit crowds and keep strangers out

A university entrance must do two things at once: admit hundreds of students in the minutes before a lecture, and keep strangers out of the buildings behind it. A door that admits everyone admits no one safely, and a door that stops everyone stops the university working. The entrance needs lanes that admit one person at a time, at walking pace, with a wider lane beside them for wheelchairs, pushchairs and deliveries. Our security turnstiles guide compares tripod, full-height and glass optical lanes in full.

The lane type follows the risk. A waist-high tripod suits a supervised entrance where flow matters and the risk is casual, such as a staff entrance with a reception desk nearby. A full-height turnstile is a floor to ceiling rotor that admits one person per rotation and stops climbing over, and it suits an unsupervised point where the lane must hold without a guard. A glass optical lane, or speed gate, suits a lobby where appearance and pace matter. Our full height glass turnstiles page covers the glass rotor that stops tailgating at unmanned entrances, and our security portals page covers the portal where a single verified person is the rule.

Fire egress is the duty the entrance must never fail. When the alarm sounds, the lanes must release so people can leave without a credential, and the release must work even if the power fails. A turnstile that stays locked in a fire is a trap, not a control. The fire release should be tested at every inspection, and the test should be written down.

Fire and forced entry on the same doorset

Many campus doors must do two jobs: hold fire and resist forced entry. A pharmacy store door must hold fire and resist a forced entry. A server room door must hold fire and resist an attack on the equipment inside. The two jobs need two sets of evidence on one assembly: a fire classification to EN 1634-1 and a forced entry rating to LPS 1175 or PAS 24. A steel leaf is strong, but strength is not a security rating, and a door rated FD60 can still fail a forced entry test.

LPS 1175 rates a doorset by the tools and the time it resists. A SR2 rated steel door resists three minutes of attack with tools such as screwdrivers, pliers and hand saws. C5 covers five minutes with crowbars, drills and chisels, and D10 covers ten minutes with sledgehammers, disc cutters and jigsaws. PAS 24 is the enhanced security standard for doorsets, and EN 1627 sets resistance classes RC1 to RC6 for windows, doors and shutters. The rating belongs to the complete tested assembly, not to the leaf alone, so a rated leaf in an untested frame is not a rated doorset. Our fire rated steel doors page covers the steel leaf that carries both jobs most often, and our dual certification guide works through how fire and security sit on one assembly.

The rating must stay valid after handover. A change to the leaf, the frame, the glass, the seals or the hardware can break the tested construction, and a door that has been changed without fresh evidence has no proven rating. Our keeping an LPS 1175 rating valid guide sets out the changes that void a rating and the inspection routine that keeps it alive.

Access control at campus scale: cards, readers and the record

Access control on a campus is a list of thousands of people, and the way the campus checks each one. Students carry cards, staff carry fobs, visitors use a code or a pass, and contractors use a temporary credential that expires when the work ends. Each method suits a different entrance: a hall needs cards that work late at night, a lecture building needs readers that work at walking pace, and a server room needs a check that cannot be lent to another person. The reader, the credential and the software behind them are one system, and the order should name all three.

The system should open for the right people and stay closed for everyone else, and it should keep a record of who passed and when. A log that names the credential, the time and the direction of travel is the record the campus needs when a person is found where they should not be. Cards should be cancelled when they are lost, codes should be changed when staff leave, and the list of people who can pass each door should be checked as often as the door itself. Our security turnstiles guide works through readers, fobs and biometrics and how the lane is wired into the access system.

Access control and the wider campus must work together, not against each other. The doors should talk to the same system as the turnstiles, the lifts and the car park, so a person who loses access loses it everywhere at once. Ask for the integration to be named on the order, with the software, the reader type and the record the system keeps.

Ordering for a university estate: one schedule, one set of evidence

Ordering doors for a university is a specification exercise, not a shopping exercise. The order should name the rating in full, FD30 or FD60 with the letter and the smoke rating where the strategy asks for it, and it should name the leaf, the frame, the glass, the beads, the seals and the hardware as one doorset.

The security side needs its own evidence where the door must also resist attack. A lock is not a security rating, and a steel leaf is strong but strength is not a rating. Security comes from a separate test, LPS 1175 or PAS 24, on the whole doorset.

Finally, order the evidence with the doors. The test report, the classification and the hardware schedule should arrive with the doorset, and the handover pack should name the inspection routine the campus will follow. A campus that files the evidence on the day the doors arrive has a record it can use for the whole life of the estate. Our fire door inspection checklist gives the checks that catch a failing leaf before it matters.

Building Door position Rating What to check
Halls of residence Student room door FD30S Closer, smoke seals, latch, 4 mm gaps
Lecture building Theatre and escape doors FD30 or FD60 Panic hardware, opening force, vision panel
Library Reading room and store doors FD30 or FD60 Closer setting, latch, hold-open release
Main entrance Turnstile lanes and wider lane LPS 1175 where rated Free exit, wider lane, reader pace
Plant and store Plant room and store doors FD60 Seals, gaps, self-closing

On a campus, a door wedged open for convenience has stopped doing both of its jobs: it holds back no fire and no stranger.

Who is responsible for fire doors on a university campus?

The Regulatory Reform (Fire Safety) Order 2005 names a responsible person for the premises, and on a campus that is usually the university as the occupier of its own buildings, with the estates team carrying the day to day work. Where a building is leased, the lease divides the duty, and the boundary should be written down in the fire risk assessment.

Do halls of residence need FD30 or FD60 doors?

They need the rating the fire strategy names for their position, and a student room door commonly carries FD30 with smoke control, marked FD30S, because the corridor outside the room is the escape route for everyone on that floor. Plant rooms, stores and doors that protect a long escape route commonly carry FD60, because the people and the contents behind them need more time.

Can one doorset carry a fire rating and a security rating?

Yes, where both sets of evidence cover the same construction. The fire classification comes from a test to EN 1634-1 and the forced entry rating from a test to LPS 1175 or PAS 24, and the two must be proved on the same doorset. A steel leaf is strong, but strength is not a security rating, and a door rated FD60 can still fail a forced entry test.

How do turnstiles fit with fire escape at a university entrance?

The lanes must release when the alarm sounds, so people can leave without a credential, and the release must work even if the power fails. A turnstile that stays locked in a fire is a trap, not a control. The fire release should be tested at every inspection, and the wider lane must open in one action for wheelchairs, pushchairs and deliveries.

What should a university door schedule name for each opening?

The building, the position, the fire rating, the security rating where one is needed, and the leaf, the frame, the glass, the beads, the seals and the hardware as one doorset. The schedule should travel with the order, and the test report, the classification and the hardware schedule should arrive with the doorset.

Rating door by door: the opening sets the rating

A campus holds many buildings behind many doors, and each door faces its own risk. The front entrance has staff beside it all day, while a rear door opens onto a yard nobody watches after hours, so the two doors ask different questions of the schedule. Give each opening its own line, with the building, the position and the rating named on it, and set the rating by the attack the opening could face. A schedule that hands every door the same rating spends money where the risk is lowest and leaves the doors that face the most risk short.

LPS 1175 grades a doorset on two facts: the tools it resists and the minutes it holds. Against category B tools, screwdrivers, pliers and hand saws, three minutes earns B3. Against category C tools, crowbars, drills and chisels, five minutes earns C5. Against category D tools, sledgehammers, disc cutters and jigsaws, ten minutes earns D10. The current labels come from LPS 1175 Issue 8.2, dated September 2024, and drawings made before the change still show the earlier ones, so SR2 reads as B3, SR3 as C5 and SR4 as D10. The forced entry ratings are set out in full on our LPS 1175 page.

A door that must also resist a quiet attack needs a second rating beside the first. LPS 2081 grades a doorset against a stealth attack, SRA for one minute and SRB for three, and the rating follows the opening: one minute suits a door where a guard or a camera will spot the attempt quickly, and three minutes suits a door where the attack has longer to work unnoticed. LPS 2081 proves stealth resistance and nothing else, so a door that must hold against hand tools as well needs a rating to LPS 1175 or PAS 24 beside it.

Halls, labs and stores: three doors, three ratings

A hall of residence door does two jobs at once. It holds fire inside the room and keeps strangers out while the resident is away, so the fire side is proved by a classification to EN 1634-1 and the security side by a rating to LPS 1175 or PAS 24, each proved on the same doorset. Our flat entrance doors guide covers the door in full, and our LPS 1175 vs PAS 24 guide compares the two forced entry routes.

A laboratory door faces a different risk again. The room behind it holds equipment and samples that cannot be replaced, so the door takes the rating the risk asks for, and the schedule shows the risk beside the rating, so the next reader can see why each door carries the rating it does. A store door onto a quiet yard takes the higher rating, because nobody watches it after hours, while a staffed entrance that faces little risk takes the lower one. No published table converts an LPS 1175 rating into an EN 1627 class, and a specification that names one by quoting the other has asked for something that does not exist. EN 1627 sets its own classes, RC1 to RC6, and each one needs its own test report behind it.

Door Rating Why
Hall of residence entrance FD30S + B3 or PAS 24 Fire and forced entry on one doorset
Laboratory door C5 or D10 High value equipment behind the leaf
Store onto a quiet yard C5 + SRB Unwatched after hours, stealth and forced entry
Staffed main entrance B3 Guarded, low risk, short response time

Keep the test report, the rating and the risk beside each opening in one file, and ask for the evidence on the whole doorset, not on the leaf alone. Our how to specify security doors guide sets the columns for the same discipline.

Specifying doors for a university estate?Send the door schedule and the fire strategy for a tested doorset quotation.
Get a free quote

Related

More in guides for specifiers

10 mistakes when specifying certified security doors 10 steps to specify an LPS 1175 door Acceptance and Snagging of a Security Door or Barrier Job Access Control Doors Acoustic Doors: Ratings and Specification After a Forced Entry Attempt: Checking a Security Door Airport Security Doors Anti-Ligature Doors for Mental Health Wards Anti-Ram Bollards Anti-ram gates and barriers: protecting vehicle entrances Arcade Security Doors Explained Automatic Doors Automatic Gates Cost Factors Automatic Vehicle Barriers Ballistic Panels Bank Security Doors Bingo Hall Security Doors Explained Blast doors: glazed vs solid and how they are rated Blast protection window film: what it does and what it cannot do Blast resistant windows: what drives the cost and how to specify them Bollard Cost Factors Explained Bollard regulations in the UK: spacing, height and depth Bookmaker Security Doors Explained Builders Merchant Security Doors Bullet Resistant Glass Cost Factors Bullet resistant glass ratings explained: BR1 to BR7 and SG classes Bullet resistant vs bulletproof glass: what the difference means Buying Security Doors and HVM Through Public Frameworks Car Park Security Doors Explained Car Showroom Security Doors Casino Security Doors Explained CDM 2015 Duties When Security Doors, Shutters or HVM Are Installed Cinema Security Doors Cleanroom Doors Cold Store Doors College Security Doors Commissioning, Handover and the O&M Manual for Security Doors and HVM Communal entrance doors for flats: Secured by Design and what to specify Community Centre Security Doors Control Room Doors Court Security Doors Crash Rated Fences and HVM Fencing Explained Data centre physical security: doors, glazing, HVM and shielding by zone Dental Practice Security Doors Depot Security Doors Explained Door Entry Systems Due Diligence When Selecting Vehicle Security Barriers Emergency Exit Doors EMP Shielding Cost Factors Explained Exhibition Centre Fire Door Rules Exhibition Centre Security Doors Factory Security Doors Faraday cage vs RF shielded room: what a business needs FB4 vs FB6 vs FB7: how to choose a ballistic rating Fire and security doors: how dual certification works Fire Compartmentation Fire Curtains Fire Door Certification Fire Door Closers Explained Fire Door Cost Factors Fire Door Duties of the Accountable Person Fire Door Gaps Fire Door Hardware Explained Fire door inspection checklist for steel and timber doors Fire Door Maintenance Fire Door Regulations Care Homes Fire Door Regulations for A and E Departments Fire Door Regulations for Airports Explained Fire Door Regulations for Bowls Clubs Fire door regulations for commercial buildings in the UK Fire Door Regulations for Dialysis Centres Fire Door Regulations for Hockey Clubs Fire Door Regulations for Hospitals Explained Fire Door Regulations for Offices Explained Fire Door Regulations for Operating Theatres Fire Door Regulations for Retail Explained Fire Door Regulations for Schools Explained Fire Door Regulations for Snooker Clubs Fire Door Regulations for Stadiums Fire Door Regulations for Student Accommodation Fire Door Regulations for Warehouses Fire Door Regulations Leisure Centres Fire Door Regulations Restaurants Fire Door Remediation Programme for Housing Providers Fire Door Rules for Badminton Clubs Fire Door Rules for Bingo Halls Fire Door Rules for Bookmakers Fire Door Rules for Bowling Alleys Fire Door Rules for Car Parks Fire Door Rules for Car Showrooms Fire Door Rules for Cinemas Fire Door Rules for Climbing Centres Fire Door Rules for Colleges Fire Door Rules for Community Centres Fire Door Rules for Cricket Clubs Fire Door Rules for Dental Practices Fire Door Rules for Depots Explained Fire Door Rules for Golf Clubs Fire Door Rules for GP Surgeries Fire Door Rules for Gyms Explained Fire Door Rules for Ice Rinks Fire Door Rules for Maternity Units Fire Door Rules for Mental Health Units Fire Door Rules for Museums Fire Door Rules for Oncology Units Fire Door Rules for Opticians Fire Door Rules for Pawnbrokers Fire Door Rules for Petrol Stations Fire Door Rules for Pharmacies Fire Door Rules for Ports Fire Door Rules for Post Offices Fire Door Rules for Prisons Fire Door Rules for Rehabilitation Centres Fire Door Rules for Self Storage Fire Door Rules for Shopping Centres Fire Door Rules for Squash Clubs Fire Door Rules for Supermarkets Fire Door Rules for Swimming Pools Fire Door Rules for Tennis Clubs Fire Door Rules for Theatres Fire Door Rules for UK Arcades Fire Door Rules for UK Casinos Fire Door Rules for UK Hospices Fire Door Rules for Walk-in Centres Fire Door Signage Fire Door Vision Panels Fire Doors and Gateway 2 in Higher-Risk Buildings Fire Rated Glass Cost Explained Fire Rated Sliding Doors Explained Fire Rated Windows Cost Factors Fire Rated Windows Explained Fire Safety Enforcement Notices and Fire Doors: What the Responsible Person Must Do Flat Entrance Doors: PAS 24 and Fire Rated Forced Entry vs Ballistic vs Blast: Which Rating a Site Needs Garage Security Doors Explained Gate Automation Explained Golden Thread Records for Fire Doors GP Surgery Security Doors Explained Gym Security Doors Explained High Speed Doors HMO Fire Doors Hospice Security Doors Explained Hospital Security Doors: Wards, A&E, Plant Hospital Security Gates Hotel Fire Doors Hotel Security Doors How to choose HVM bollards: fixed, shallow mount, removable and automatic How to keep an LPS 1175 door rating valid after installation How to Specify Fire Doors in a Housing Tender How to specify security doors: a checklist for architects How to Verify a Secured by Design Listing How to Verify an LPS 1175 Certificate on Red Book Live How to Write an Operational Requirement for Physical Security HVM planters and street furniture: protection that blends in In-Service Care of Vehicle Security Barriers Installation Handover: LPS 1175 Doors and PAS 68 Barriers Intumescent Seals ISO 16933 explained: EXV and SB classes and hazard ratings ISO 22343 vehicle security barriers explained Keeping a Dual-Certified Fire and Security Door Valid in Service Laboratory Security Doors Layered Security for a Site: Deter, Detect, Delay, Mitigate, Respond Lead Times and Programme Risks for LPS 1175 Doors Leisure Centre Security Doors Library Security Doors Listed Building Fire Doors Loading Bay Doors Explained Lockdown and Access Control Hardware on an LPS 1175 Door LPS 1175 Gates and Grilles Explained LPS 1175 Issue 8 explained: from SR1 to SR8 to A1 to H20 LPS 1175 Roller Shutters LPS 1175 vs ASTM F2781 and Other US Ratings Explained LPS 1175 vs EN 1627: how UK and European burglar resistance ratings compare LPS 1175 vs PAS 24: which security standard does your door need? LPS 1175 Windows and Walling Explained Martyn’s Law and Places of Worship: What a Buyer Checks for Doors and Entry Control Martyn’s Law Enhanced Tier: Physical Measures and the Specifier Brief Martyn’s Law Standard Tier: Procedures, Doors and Shutters Martyn’s Law Timeline and the SIA Regulator Martyn’s Law: what premises must do and which physical measures to consider Master Key Systems MRI and RF shielded rooms: how they work and what to specify Museum Security Doors NPSA Catalogue of Security Equipment (CSE) Explained NPSA Forced Entry and Blast Guidance for Government Sites NPSA Guidance on Lockdown and Marauding Attack: What It Asks of Doors and Entrances Office Security Doors Optician Security Doors Explained Panic Hardware PAS 24 requirements for doors and windows explained PAS 68 Bollard Foundations Explained PAS 68 bollards: ratings, spacing and cost factors PAS 68 vs IWA 14 vs ISO 22343: hostile vehicle mitigation standards explained Pawnbroker Security Doors Explained Pedestrian Gates Petrol Station Security Doors Pharmacy Security Doors Planning Permission for Security Shutters, Gates and Bollards on Commercial Premises Plant room doors: fire, security and ventilation requirements Plant Room Fire Doors Port Security Doors Post Office Security Doors Explained Powder coating vs galvanising vs paint for steel Preliminary Market Engagement for Security Doors and HVM Prison Security Doors Programming a Security Door and Barrier Package on a Live Site Public-Sector Tender Response Checklist for Security Door and HVM Supply Reading a PAS 24 and SBD Door Test Report Regulation 38 Fire Safety Information at Handover for Fire-Rated Security Doorsets Replacing Security Doors in an Occupied Building Restaurant Security Doors Retail Security Doors Revolving Doors RF shielding standards and how shielded rooms are tested Rising Bollard Cost Factors Road Blocker Cost Factors Explained Road Blockers Explained Roller Shutter Cost Factors: What Drives the Price Roller shutter regulations in the UK: safety and maintenance Safe room and panic room doors: specification basics Safety Duties for Powered Doors, Gates and Barriers on Commercial Sites School Security Doors Sectional Doors Secured by Design explained: is it mandatory for doors? Secured by Design vs NPSA vs LPCB: Which One You Need Security Door Locks Security Door Maintenance Checklist Security Doors and Access for Everyone: What Approved Document M Asks Security Doors for A and E Departments Security Doors for Badminton Clubs Security Doors for Bowling Alleys Security Doors for Bowls Clubs Security Doors for Climbing Centres Security Doors for Cricket Clubs Security Doors for Dialysis Centres Security Doors for Golf Clubs Security Doors for Hockey Clubs Security Doors for Ice Rinks Security Doors for Maternity Units Security Doors for Mental Health Units Security Doors for Oncology Units Security Doors for Operating Theatres Security Doors for Rehabilitation Centres Security Doors for Snooker Clubs Security Doors for Squash Clubs Security Doors for Swimming Pools Security Doors for Tennis Clubs Security Doors for Walk-in Centres Security Doors West Midlands Explained Security Fencing Security Gates Cost Factors Explained Security shutters vs high performance roller doors Security shutters vs retractable grilles: which suits retail and commercial openings? Security Turnstiles Explained Security Window Film Security Windows for Schools Explained Self Storage Security Doors Server Room Doors Explained Shopping Centre Security Doors Smoke Control Doors Explained Smoke Curtains Specification Mistakes When Mixing LPS 1175, PAS 24 and SBD in One Tender SR2 vs SR3 vs SR4 security doors: choosing the right LPS 1175 level Stadium Security Doors Steel Door Frames Steel vs aluminium security doors: strength, ratings and looks Steel vs timber fire doors: which suits your building? Student Accommodation Security Doors Substation doors: security, ventilation and specification Supermarket Security Doors Telescopic Bollards Tender Evaluation Criteria and Scoring for Security Doors and HVM The Scope of a Maintenance Contract for Security Doors and Barriers Theatre Security Doors Thermal and Weather Performance of External Security Doorsets Thermally broken steel security doors: U-values and certification Traffic Calming as Hostile Vehicle Mitigation Transport hub security requirements Turnstile Cost Factors Explained Turnstile vs speed gate vs security portal: choosing entrance control Types of security doors for commercial buildings Vehicle Dynamics Assessment: What It Tells the Buyer Before a Barrier Is Specified Warehouse Security Doors Explained Warehouse Security Gates Warranty, Defects Liability and Guarantees for Security Doors and Barriers What affects the cost of a bullet resistant door What affects the cost of a high-security door in the UK Window Security Bars View all →

Products

One supplier for the whole building envelope

Ready to specify your project?

Free assessment, written specification and test evidence. Reply within one working day.