ArxBridge
NPSA Guidance on Lockdown and Marauding Attack: What It Asks of Doors and Entrances
NPSA guidance sets out evacuation, invacuation and lockdown for a marauding attack. This guide sets out what it asks of doors and entrances.
- ✓Third-party test evidence with every product
- ✓Written specification you can issue to tender
- ✓Supplied and installed across the UK
Get a free project quote
Rating, written specification and budget range within one working day.
Confidential. No cost, no obligation.
Third-party tested
Evidence with every quote
UK manufactured
Made to your sizes
One accountable team
Specify, supply, install
Confidential handling
Details never shared
When a marauding attack threatens a premises, the NPSA guidance gives those responsible three responses: evacuation, invacuation and lockdown. The choice depends on where the threat is and where the people are, and the doors and entrances of the building decide which response can work.
- EvacuationMove people out
- InvacuationMove people inside
- LockdownSecure the doors
- DoorsDelay the attacker
Three responses, one decision
The NPSA guidance for evacuation, invacuation and lockdown says the main aim is getting people away from danger, and there are three primary ways to do this: evacuation, invacuation and lockdown. Each incident is unique, so the plans need to be flexible and adaptable to any situation.
Evacuation moves people away from danger by exiting a premises or site. Invacuation moves people away from danger to a safe area within a premises, and can include people in the immediate vicinity. Lockdown secures doors or other barriers to restrict access to the entire premises or specific areas, preventing hostile actors from moving freely.
All response policies must follow fire and health and safety law. The NPSA guidance page sets out the three responses in full, with the policy and procedure lists for each.
Lockdown: the four methods and what each door does
The guidance names four lockdown methods. A one-way lockdown prevents entry but allows people to escape. A two-way lockdown restricts both entry and exit. A partial lockdown locks only certain doors, such as main entrances, while keeping some escape routes open. A zonal lockdown locks down specific pre-designated areas within the premises.
A lockdown may be preceded or followed by an invacuation to a designated safe area, and a partial lockdown may be combined with a directional evacuation.
The procedures must name the doors, shutters and other access points to be secured quickly, with directions on how they are secured and when they can be reopened. Role-specific standard operating procedures should say which role holder closes each barrier and access point. The hardware guide for lockdown covers the locks and the release on a rated door. A powered door must shut fast when a lockdown is called, and the powered door safety duties guide names the checks PUWER asks for.
The fire plan and the lockdown: the conflict to settle in advance
A lockdown and a fire evacuation pull in opposite directions, and the guidance says the conflict must be resolved before the day, not during it. If a fire was started inside the building whilst a two-way lockdown was in place, there are no hard and fast rules: a lockdown should be put in place to try and keep people safe, and if circumstances change and it is considered a better option to evacuate, that should be done.
Decisions must be made on what is happening, and the guidance says decision makers on the ground should be empowered to take dynamic action. The fire door inspection checklist has the points one door is checked against, and the maintenance checklist guide has the checks a door needs over its life. A fire door that fails its checks can bring a notice from the fire and rescue authority, and the enforcement notices guide explains what happens after a fire and rescue authority serves a notice.
Invacuation: the safe area inside
Invacuation is the right call when moving people out risks moving them towards danger, typically when a suspected incident is under way and the location of the threat actor is uncertain. The guidance gives examples: an attack nearby, an explosion, a suspicious vehicle outside, or a suspicious package at the main entrance.
The policy must name the designated safe areas within the premises, work out the safe capacity of the areas, and assess whether this meets the potential need. Stepped locations should be avoided, due to the potential safety risks of holding a high density of people on stairs.
For high risk premises, safe areas may benefit from doors, windows, walls and ceilings rated for security, blast or ballistic attack. Such features may afford an extended time delay against a person trying to force entry. The NPSA forced entry and blast guide has the research on steel doorsets under attack.
Marauding attack: what the guidance asks of doors and entrances
A marauding terrorist attack is a fast-moving, violent incident where assailants move through a location aiming to kill or injure as many people as possible. The guidance works through a scenario of an attack outside a premises, involving two or more attackers armed with knives and machetes, and asks staff to work through the response: who initiates a lockdown, how it is communicated, what happens to people outside the doors about to be locked, and whether an invacuation is now part of the response.
Doors and entrances are the delay in that scenario. MTAS, the Marauding Terrorist Attack Standard, gives a barrier a score for the time it holds back a person attacking it with a blade, a gun or explosives pressed against it.
Nothing in the guidance asks a buyer to buy a listed product. The guidance asks for procedures, for doors that can be secured quickly, and for staff who know their roles. The operational requirement guide sets out how to write the threat and the delay a measure must achieve.
Martyn’s Law: procedures now, measures at 800 and above
The 2025 Terrorism (Protection of Premises) Act, known as Martyn’s Law, gained Royal Assent on 3 April 2025. The Home Office statutory guidance under section 27 was presented to Parliament on 15 April 2026, and the Act is expected to be in force from spring 2027.
For a standard tier premises, 200 to 799 people could reasonably be expected to be there at the same time, the duty is to have public protection procedures in place, so far as reasonably practicable. The statutory guidance on gov.uk sets out the tiers and the duties in full.
The guidance also says no physical alterations or specific equipment are required for the procedures. An enhanced tier premises is one where 800 or more people could reasonably be expected to be on site at once, and it must also prepare public protection measures and a document. The Martyn’s Law standard tier guide sets out the four procedures, and the enhanced tier guide sets out the measures.
Writing the policy: who initiates, who closes which door, drills and the record
A lockdown can be initiated by any member of staff who becomes aware of a real and immediate threat. The policy should also say how the response is communicated, how the emergency services are called and updated, and what they need to know about entering the building if it is still in lockdown and people have invacuated.
The policy should say whether staff should try to bring people in, at what point that compromises the security of others, and what should happen if someone wants to leave during a lockdown.
The guidance says scenario-based exercises should be run on a consistent basis, the response should be debriefed, and a clear record of the incident should be made as soon as possible after it.
| Response | What it does | When it fits |
|---|---|---|
| Evacuation | Moves people out of the premises | Threat inside, outside is safer |
| Invacuation | Moves people into a safe area inside | Threat outside, location uncertain |
| One-way lockdown | Stops entry, lets people escape | Threat outside a containable zone |
| Two-way lockdown | Stops entry and exit | Threat outside, people held inside |
| Partial or zonal lockdown | Secures some doors or areas | Part of the premises at risk |
The doors decide which response can work. Name every door that must be secured, who closes it, and how the fire plan still lets people out.
How does invacuation differ from lockdown?
Invacuation moves people to a safe area inside the premises, away from a threat outside. Lockdown secures the doors and barriers to stop an attacker moving freely. The two are often combined: people are brought inside, into a partial lockdown, then released in a partial or directional evacuation as the picture changes.
Should a fire alarm be used to start a terrorist evacuation?
Ideally not. The NPSA guidance says using a fire alarm in these situations may put people in danger, because people may follow the marked fire route into the path of an attack, or gather at an assembly point in the open. A public address announcement or a different warning signal is preferable.
What does MTAS measure?
MTAS, the Marauding Terrorist Attack Standard, scores a barrier on the time it holds back an attacker with a blade, a firearm or explosives in contact with it. MTAS does not test how quickly a barrier can be shut and opened again for escape.
Does Martyn’s Law require buying new doors or equipment?
No. The statutory guidance says the procedures need no physical alterations and no specific equipment bought for them. The standard tier duty is to have procedures in place, as far as reasonably practicable, covering evacuation, invacuation, lockdown and communication.
Who can start a lockdown?
Any member of staff who sees a real and immediate threat can start the response, and the policy should name who manages it and who closes each door. The procedures should be tested often, and a record kept of the incident and the decisions made.
Contact us for a free quote
Related
More in guides for specifiers
Products
One supplier for the whole building envelope
Ready to specify your project?
Free assessment, written specification and test evidence. Reply within one working day.