Thermal and Weather Performance of External Security Doorsets
Approved Document L sets a U-value limit for every external doorset. This guide gives the figures, the weather checks, and one specification for both.
- ✓Third-party test evidence with every product
- ✓Written specification you can issue to tender
- ✓Supplied and installed across the UK
Get a free project quote
Rating, written specification and budget range within one working day.
Confidential. No cost, no obligation.
Third-party tested
Evidence with every quote
UK manufactured
Made to your sizes
One accountable team
Specify, supply, install
Confidential handling
Details never shared
A security doorset has two jobs: hold the line against attack, and hold the heat inside the building. Approved Document L sets the U-value limit the doorset must meet, and the same document asks for a fitting that is well fitted and reasonably draught-proof. This guide gives the figures, the weather checks, and one specification for both.
- U-valueThe limit in the table
- AirtightnessFitted and draught-proof
- SealsThe weather line
- One specificationSecurity and heat together
What a U-value measures on a doorset
A U-value measures how much heat passes through a square metre of a doorset for each degree of difference between inside and outside, in watts per square metre kelvin. The lower the figure, the less heat the doorset lets through, and the figure covers the complete doorset, not the leaf on its own.
The figure is a maximum, not a target to beat by a little. A doorset that meets the limit sits inside the standard the building has to meet, and a doorset that misses it does not. The thermally broken doors guide covers the thermal break, the U-value and the certificate in full.
Ask for the figure for the doorset as supplied, in writing, with the test evidence behind it. A figure for the leaf alone, a figure for a different size, or a figure for a doorset with different glazing is not the figure for the doorset on your order.
The limits Approved Document L sets
Approved Document L, Volume 2, sets the limits for buildings other than dwellings in a single table. A pedestrian door, including a glazed door, is limited to 1.6 W/(m²·K). A vehicle access door and similar large doors are limited to 1.3, and a high-usage entrance door is limited to 3.0.
An external fire doorset is allowed more. Where the doorset is an external fire doorset, as defined in Appendix A of Approved Document B, Volume 2, in a building other than a dwelling, a maximum U-value of 1.8 W/(m²·K) is permissible. The allowance sits in note 14 to the table.
The table also sets the air permeability limit for a new building: 8.0 cubic metres per hour per square metre at 50 pascals. That figure is for the building as a whole, not for one doorset. The 2026 edition of Approved Document L, Volume 2 carries the table as Table 3.1, and the 2021 edition carries the same figures as Table 4.1.
Which edition applies to your job
Two editions are in play, and the one that applies depends on the job. The 2021 edition, incorporating the 2023 amendments, has been in force since 15 June 2022. The 2026 edition takes effect on 24 March 2027, and on 24 September 2027 for work in connection with higher-risk building work.
The door figures do not change between the editions. Table 4.1 of the 2021 edition and Table 3.1 of the 2026 edition give the same limits for pedestrian doors, vehicle access doors, high-usage entrance doors and external fire doorsets, so a specification that names the figure works under either edition.
Ask the building control body which edition the job falls under, and write the answer into the specification. A doorset ordered to the wrong edition has to be re-specified, and the re-specification costs more than the question. The replacement guide covers the same question for a door swapped in an occupied building.
Weather at the threshold: seals and draughts
Approved Document L sets no wind-driven-rain figure for a doorset. What it asks for, where a whole unit is replaced, is that the unit is draught-proofed, that it meets the limiting U-value, and that insulated cavity closers are fitted where they are appropriate. The weather line of a doorset is its seals, its threshold and its fit.
A controlled fitting in an existing building has to be well fitted and reasonably draught-proof. That means the leaf sits true in its frame, the seals touch the leaf all round, and the threshold meets the floor without a gap. The maintenance checklist guide sets out the seal and closer checks that keep a door draught-proof in use.
Ask the supplier for the weather result for the exact doorset, leaf, frame and seals together. A result for the leaf alone, or for a doorset of a different size, does not prove the doorset on your order. LPS 1175 Issue 8.2 (September 2024) judges a doorset as one assembly, and the same logic holds for weather.
Cold bridging at the frame and the fixings
Heat does not only leave through the leaf. It leaves through the frame, through the fixings, and through the joint where the frame meets the wall, and a doorset that is warm in the middle can still be cold at its edges. The document asks that the insulation is reasonably continuous, and that thermal bridging is reasonably limited.
The joint needs the same care as the leaf. The insulation layer should abut the air barrier at all points, or the space between the air barrier and the insulation layer should be filled with solid material. A gap left open at the frame is a gap the heat finds.
Where a thermal element is replaced or renovated, the document asks for a report, signed by a suitably qualified person, which states that appropriate design details and building techniques have been specified, and that the details, as built, give adequate protection against surface condensation. The keeping the rating valid guide walks through the checks a door gets through its life.
One specification for security and heat
Write one clause that names both jobs. Name the security rating the doorset must hold, and name the U-value limit it must meet, in the same line, for the same doorset, in the same opening. A clause that names the rating in one place and the U-value in another lets the two drift apart.
Name the evidence with the figures. The certificate that proves the rating, the test evidence that proves the U-value, and the weather result for the exact doorset: each one named in the clause, each one due before the order is placed. The specification guide treats opening, frame and hardware as one job, and the thermal clause sits in the same schedule.
Name the fire allowance only where it applies. The 1.8 figure is for an external fire doorset in a building other than a dwelling only, and it does not lift the limit for any other door. The access guide sets out the force and width checks a rated door has to pass, and the forced entry guide covers what to check when a door has been attacked.
The papers to ask for before you order
Three papers belong on the order: the certificate for the security rating, the test evidence for the U-value of the doorset as supplied, and the weather test result for the exact doorset. A paper that names a different size or a different leaf is not evidence for the doorset on your order.
Check the listing too. Secured by Design lists products that have passed their own tests and been certified by a UKAS-recognised third-party body, and the listing should be live at the date of the order. The commissioning and handover guide names the papers a door should carry, and the listing check joins them.
Keep the papers with the door. The Red Book Live listing names LPS 1175 as Issue 8.2, and the certificate for the doorset should name the same issue. The LPS 1175 and PAS 24 guide sets the two standards side by side.
| Doorset | Limit | Where it sits |
|---|---|---|
| Pedestrian door, including glazed | 1.6 W/(m²·K) | Table 3.1, 2026 edition |
| Vehicle access and similar large doors | 1.3 W/(m²·K) | Table 3.1 |
| High-usage entrance door | 3.0 W/(m²·K) | Table 3.1 (2026) |
| External fire doorset, other than a dwelling | 1.8 W/(m²·K) | Note 14 to Table 3.1 |
| Air permeability, new building | 8.0 m³/(h·m²) at 50 Pa | Table 3.1, 2026 edition |
The limit is a maximum for the whole doorset. Judge the figure on the doorset as supplied, not on the leaf alone.
What U-value must an external security doorset meet?
The table gives 1.6 W/(m²·K) for a pedestrian door, including a glazed door. Vehicle access doors sit at 1.3, high-usage entrance doors at 3.0, and external fire doorsets in buildings other than dwellings at 1.8.
Which edition of Approved Document L applies?
Most live work still follows the 2021 edition, which came into force on 15 June 2022. The 2026 edition comes into effect on 24 March 2027, or on 24 September 2027 for higher-risk building work. Ask the building control body which edition your job falls under.
Does Approved Document L set a wind-driven-rain limit for doorsets?
No. The document does not give a rain figure for a doorset. It asks for draught-proofing, the limiting U-value, and insulated cavity closers where they fit. The weather evidence to ask for is the result for the exact doorset.
What is the air permeability limit?
The limit is 8.0 cubic metres an hour for each square metre, at 50 pascals, and it applies to a new building as a whole. No single doorset carries it on its own.
How do I ask for the security rating and the U-value together?
Write one clause that names both for one doorset in one opening: the security rating, the U-value limit, and the evidence for each. Name the certificate, the test evidence and the weather result, and ask for all three before the order is placed.