Certified physical security

ArxBridge
Steel door sample in a security test frame with an assessor in a UK test laboratory

ArxBridge

Due Diligence When Selecting Vehicle Security Barriers

A barrier that stops a vehicle at speed can still fail against ramming. Learn the two ratings, the as-tested trap, and the checks to run before you sign.

  • ✓Third-party test evidence with every product
  • ✓Written specification you can issue to tender
  • ✓Supplied and installed across the UK
Prefer to talk?+44 7352 267239

Get a free project quote

Rating, written specification and budget range within one working day.

ArxBridge Quote Form

Confidential. No cost, no obligation.

Third-party tested

Evidence with every quote

UK manufactured

Made to your sizes

One accountable team

Specify, supply, install

Confidential handling

Details never shared

A barrier that stops a vehicle at speed can still fail against a ramming attack, and a barrier with the right rating can still fail if it is installed differently from the test. Due diligence is the set of checks a buyer runs before the order is placed, while the choice can still change.

  • Two ratingsImpact rating and delay rating, both needed
  • 30 secondsMinimum hold for a delay rating
  • 1.2 metresMaximum gap in a barrier line
  • As tested onlyA rating covers one configuration

Due diligence starts before the product

NPSA and NaCTSO, the National Counter Terrorism Security Office, write their temporary barriers note for local authorities, event organisers and similar end user groups. Its first point is that a full risk assessment, based on threat reporting and identifying vulnerabilities, comes before any product is chosen. It is important to understand your objectives before seeking solutions, because barriers vary in capability, deployment demands, operation and cost.

The same order runs through all NPSA guidance. The HVM page on the NPSA site sets out the steps: develop the requirement, add a user requirement document where business needs are not covered, carry out a practical site assessment, run a technical assessment such as a Vehicle Dynamics Assessment, and liaise with NPSA, Counter Terrorism Security Advisers, or professionals on the Register of Security Engineers and Specialists.

Our guide to writing an Operational Requirement covers that document in full. The point for a buyer is simple: a barrier chosen before the threat is quantified is a guess, and the due diligence checks below are how the guess is tested.

The two ratings a barrier should hold

NPSA and NaCTSO recommend that a barrier holds both types of rating: an impact rating and a delay rating. The impact rating comes from a vehicle impact test standard, and the default standard as of 2024 is ISO 22343-1, with IWA 14-1 and PAS 68 as the other recognised standards. The test runs a car, a 4×4 or a truck into the barrier at 48, 64 or 80 kilometres per hour, and records whether the vehicle was restrained and how far it and the debris travelled.

The delay rating is given under the NPSA Vehicle Attack Delay Standard, known as VADS. It tests barriers, typically lightweight and temporary ones, against repetitive vehicle nudge and ramming, usually with a 4×4 and sometimes a truck. If the barrier holds for at least 30 seconds it earns a 30-second rating. If it holds for at least 60 seconds it earns a 60-second rating. Falling short of 30 seconds means the barrier fails.

Only barriers that pass testing should be used to form a HVM scheme. A barrier with only one of the two ratings answers only half the question. Our ISO 22343 guide shows how to read an impact rating code, and the Catalogue of Security Equipment guide explains how to check a listing for each rating.

Need this specified for your project?Free rating, written specification and budget range within one working day.
Get a free quote

Check the listing in the catalogue

The catalogue carries separate chapters for impact rated and delay rated HVM products. A barrier listed in the first chapter has passed a vehicle impact test. A barrier listed in the second has passed the VADS delay test. The listing states the configuration that holds the rating, and the buyer should check that the configuration on offer matches it.

NPSA strongly recommends that the end user verifies a VADS approval by confirming the product is present in the CSE chapter. The VADS approval allocated to a barrier is based on the specific layout and configuration used in testing, and the listing in the CSE chapter will state the configurations that hold the approval. Deviating from a rated configuration incurs risk.

A listing does not prove everything. Barriers in the impact rated chapter are listed for their performance only under specific test conditions; a rating does not imply the barrier will perform as tested at all sites, against all threat vehicles, or at all approach speeds. The hostile vehicle mitigation page names the barrier types and their codes, and the NPSA guidance on forced entry and blast sets out how the two ratings work together.

The as-tested trap

A rating covers the barrier exactly as it was tested: the unit, the layout, the surface it stood on, and the fixings that held it. Change any of those, and the rating stops covering the installation. The temporary barriers note states the rule plainly: a rating holds only for the configuration that was tested, and any change to it must be agreed with the installer and the risk owner first.

A buyer should therefore ask four questions about any barrier on offer: how was it tested, what is being offered for the site, what are the differences between the two, and how do those differences change the barrier’s performance. If the supplier cannot answer, the rating is not evidence for this site.

The same rule applies to foundations. A permanent unit is anchored in the ground on a foundation that carries the rating, so the order should name it. A temporary unit has no foundation, so its rating depends on the surface and the layout instead. Our planters and street furniture guide covers the same point for rated street furniture, where the unit and its foundation count as one proof.

Question What to ask for Where to check
What vehicle and speed? A VDA from a certified professional The Operational Requirement
Does it stop a vehicle at speed? Impact test report to a recognised vehicle impact standard CSE HVM Impact Rated chapter
Does it delay ramming? VADS test report, 30 or 60 seconds CSE HVM Delay Rated chapter
Does the offer match the test? Layout, surface and fixings as tested The listing and the test report
Who runs it on the day? Named operator, hours and securing plan The supplier and the risk owner

Temporary barriers for events

Temporary barriers exist for sites that need protection for a day, a weekend or a season, not all year. Event venues, seasonal markets and fan zones use units that can be put in place and taken away again. They give up some stopping power in return for quick deployment, which suits a short term threat.

The NPSA and NaCTSO note lists what an event organiser should consider before choosing: whether the barrier must stop a high speed vehicle attack, delay a ramming vehicle, or only provide a visual deterrent. A visual deterrent does not physically stop a vehicle, and the OR should say which of the three the scheme provides. The note also asks how often the barrier would need to move, who will operate and supervise it in core hours and out of hours, and how it will be secured when closed.

Crowd flow is part of the check. NPSA’s event venues guide, based on observations at fifteen events held at eight UK venues between 2017 and 2022, found that most venues choose permeable bollards in areas of high spectator footfall, because they reduce the impact on crowd flow compared with larger obstacles. Keep any gap in the line to 1.2 metres or less, keep bollards no more than 1.2 metres high and 0.3 metres wide in a flow route, and avoid placing them on corners, where turning movements push densities up.

A barrier that holds only one rating answers only half the question. Ask for both ratings, and ask for the tested configuration behind each one.

The site checks before you sign

Before a temporary scheme is signed off, the site checks matter as much as the product checks. The NPSA and NaCTSO note asks who owns the land the barrier will stand on, and whether they are aware. It asks whether traffic flow is affected or stopped, and whether an Anti-Terrorism Traffic Regulation Order is needed. An ATTRO is issued by a traffic authority acting on the recommendation of the Chief Officer of Police, under the Road Traffic Regulation Act 1984.

Other checks follow: will the barrier affect pedestrian movement, or users such as wheelchairs, mobility scooters, buggies and cyclists. Are additional safety measures needed, such as signage, a warning system or alarms. Is the barrier location and operation factored into an emergency egress plan. Has the stand-off between the barriers and the people inside been maximised, and is there a sterile zone.

Sign-off sits with the risk owner, and it should come only once the risk has been explained, the mitigations walked through, and the remaining risk accepted as a conscious decision. One significant risk is the penetration distance of a vehicle impacting a temporary barrier and taking several metres to stop, with debris propelled forward. The barrier location relative to the crowd must leave enough stand-off to keep people clear of the vehicle and the debris. The anti-ram bollards guide and the PAS 68 bollards guide cover the fixed alternatives for a site that needs a permanent line.

From temporary to permanent

Barriers can be bought outright or hired, and used on a short term, per event basis. Longer term, it is more cost effective to have a more permanent scheme installed, rather than repeat deployments of temporary barriers. With planning, the move away from temporary barriers can be done in stages to fit limited funding and annual budgets.

Installing infrastructure to host barriers on a per event basis reduces long term costs by reducing the number of temporary barriers needed. Shifting from temporary to semi-permanent barriers can be done gradually, over multiple years, to spread the initial cost of investment. The stages NPSA suggests are to prioritise barrier locations, secure investment funding, replace temporary barriers with a semi-permanent scheme, and save money on repeated deployments.

Whatever the stage, the due diligence stays the same: each new barrier, layout and surface needs the same four questions. The data centre physical security guide runs the same check zone by zone, and the rating guide for forced entry, ballistic and blast sets out which rating family each site type needs. Our Martyn’s Law enhanced tier guide applies the same discipline to venues that must show what was done and why.

What is due diligence for a vehicle barrier?

It is the checks a buyer runs before ordering: the threat is quantified, the barrier holds both ratings, the listing is checked in the catalogue, and the tested configuration matches what will be installed.

What is a Vehicle Dynamics Assessment?

It is a technical assessment of the vehicle threat at a site, carried out by a certified professional. It tells the buyer what vehicle size and approach speed the barrier must stop, and it feeds the Operational Requirement.

Can a rated barrier be hired for one event?

Yes. Numerous manufacturers and installers provide rated barriers for hire and purchase, listed in the catalogue, and they can also provide trained staff to install, operate and remove them.

What if the barrier rating does not match the threat?

NPSA and NaCTSO recommend that the ratings meet or exceed the stated vehicle threat: size of vehicle, approach speed and penetration distance. If that is not achievable, identify and manage the risk.

Who signs off a temporary barrier scheme?

The risk owner. Sign-off should follow a full briefing on the risk and the mitigations, with the remaining risk accepted knowingly.

Buying vehicle security barriers for a site or an event?Send the vehicle threat, the approach speed and the layout to be protected.
Contact us for a free quote

Related

More in guides for specifiers

10 mistakes when specifying certified security doors 10 steps to specify an LPS 1175 door Acceptance and Snagging of a Security Door or Barrier Job Access Control Doors Acoustic Doors: Ratings and Specification After a Forced Entry Attempt: Checking a Security Door Airport Security Doors Anti-Ligature Doors for Mental Health Wards Anti-Ram Bollards Anti-ram gates and barriers: protecting vehicle entrances Arcade Security Doors Explained Automatic Doors Automatic Gates Cost Factors Automatic Vehicle Barriers Ballistic Panels Bank Security Doors Bingo Hall Security Doors Explained Blast doors: glazed vs solid and how they are rated Blast protection window film: what it does and what it cannot do Blast resistant windows: what drives the cost and how to specify them Bollard Cost Factors Explained Bollard regulations in the UK: spacing, height and depth Bookmaker Security Doors Explained Builders Merchant Security Doors Bullet Resistant Glass Cost Factors Bullet resistant glass ratings explained: BR1 to BR7 and SG classes Bullet resistant vs bulletproof glass: what the difference means Buying Security Doors and HVM Through Public Frameworks Car Park Security Doors Explained Car Showroom Security Doors Casino Security Doors Explained CDM 2015 Duties When Security Doors, Shutters or HVM Are Installed Cinema Security Doors Cleanroom Doors Cold Store Doors College Security Doors Commissioning, Handover and the O&M Manual for Security Doors and HVM Communal entrance doors for flats: Secured by Design and what to specify Community Centre Security Doors Control Room Doors Court Security Doors Crash Rated Fences and HVM Fencing Explained Data centre physical security: doors, glazing, HVM and shielding by zone Dental Practice Security Doors Depot Security Doors Explained Door Entry Systems Emergency Exit Doors EMP Shielding Cost Factors Explained Exhibition Centre Fire Door Rules Exhibition Centre Security Doors Factory Security Doors Faraday cage vs RF shielded room: what a business needs FB4 vs FB6 vs FB7: how to choose a ballistic rating Fire and security doors: how dual certification works Fire Compartmentation Fire Curtains Fire Door Certification Fire Door Closers Explained Fire Door Cost Factors Fire Door Duties of the Accountable Person Fire Door Gaps Fire Door Hardware Explained Fire door inspection checklist for steel and timber doors Fire Door Maintenance Fire Door Regulations Care Homes Fire Door Regulations for A and E Departments Fire Door Regulations for Airports Explained Fire Door Regulations for Bowls Clubs Fire door regulations for commercial buildings in the UK Fire Door Regulations for Dialysis Centres Fire Door Regulations for Hockey Clubs Fire Door Regulations for Hospitals Explained Fire Door Regulations for Offices Explained Fire Door Regulations for Operating Theatres Fire Door Regulations for Retail Explained Fire Door Regulations for Schools Explained Fire Door Regulations for Snooker Clubs Fire Door Regulations for Stadiums Fire Door Regulations for Student Accommodation Fire Door Regulations for Warehouses Fire Door Regulations Leisure Centres Fire Door Regulations Restaurants Fire Door Remediation Programme for Housing Providers Fire Door Rules for Badminton Clubs Fire Door Rules for Bingo Halls Fire Door Rules for Bookmakers Fire Door Rules for Bowling Alleys Fire Door Rules for Car Parks Fire Door Rules for Car Showrooms Fire Door Rules for Cinemas Fire Door Rules for Climbing Centres Fire Door Rules for Colleges Fire Door Rules for Community Centres Fire Door Rules for Cricket Clubs Fire Door Rules for Dental Practices Fire Door Rules for Depots Explained Fire Door Rules for Golf Clubs Fire Door Rules for GP Surgeries Fire Door Rules for Gyms Explained Fire Door Rules for Ice Rinks Fire Door Rules for Maternity Units Fire Door Rules for Mental Health Units Fire Door Rules for Museums Fire Door Rules for Oncology Units Fire Door Rules for Opticians Fire Door Rules for Pawnbrokers Fire Door Rules for Petrol Stations Fire Door Rules for Pharmacies Fire Door Rules for Ports Fire Door Rules for Post Offices Fire Door Rules for Prisons Fire Door Rules for Rehabilitation Centres Fire Door Rules for Self Storage Fire Door Rules for Shopping Centres Fire Door Rules for Squash Clubs Fire Door Rules for Supermarkets Fire Door Rules for Swimming Pools Fire Door Rules for Tennis Clubs Fire Door Rules for Theatres Fire Door Rules for UK Arcades Fire Door Rules for UK Casinos Fire Door Rules for UK Hospices Fire Door Rules for Walk-in Centres Fire Door Signage Fire Door Vision Panels Fire Doors and Gateway 2 in Higher-Risk Buildings Fire Rated Glass Cost Explained Fire Rated Sliding Doors Explained Fire Rated Windows Cost Factors Fire Rated Windows Explained Fire Safety Enforcement Notices and Fire Doors: What the Responsible Person Must Do Flat Entrance Doors: PAS 24 and Fire Rated Forced Entry vs Ballistic vs Blast: Which Rating a Site Needs Garage Security Doors Explained Gate Automation Explained Golden Thread Records for Fire Doors GP Surgery Security Doors Explained Gym Security Doors Explained High Speed Doors HMO Fire Doors Hospice Security Doors Explained Hospital Security Doors: Wards, A&E, Plant Hospital Security Gates Hotel Fire Doors Hotel Security Doors How to choose HVM bollards: fixed, shallow mount, removable and automatic How to keep an LPS 1175 door rating valid after installation How to Specify Fire Doors in a Housing Tender How to specify security doors: a checklist for architects How to Verify a Secured by Design Listing How to Verify an LPS 1175 Certificate on Red Book Live How to Write an Operational Requirement for Physical Security HVM planters and street furniture: protection that blends in In-Service Care of Vehicle Security Barriers Installation Handover: LPS 1175 Doors and PAS 68 Barriers Intumescent Seals ISO 16933 explained: EXV and SB classes and hazard ratings ISO 22343 vehicle security barriers explained Keeping a Dual-Certified Fire and Security Door Valid in Service Laboratory Security Doors Layered Security for a Site: Deter, Detect, Delay, Mitigate, Respond Lead Times and Programme Risks for LPS 1175 Doors Leisure Centre Security Doors Library Security Doors Listed Building Fire Doors Loading Bay Doors Explained Lockdown and Access Control Hardware on an LPS 1175 Door LPS 1175 Gates and Grilles Explained LPS 1175 Issue 8 explained: from SR1 to SR8 to A1 to H20 LPS 1175 Roller Shutters LPS 1175 vs ASTM F2781 and Other US Ratings Explained LPS 1175 vs EN 1627: how UK and European burglar resistance ratings compare LPS 1175 vs PAS 24: which security standard does your door need? LPS 1175 Windows and Walling Explained Martyn’s Law and Places of Worship: What a Buyer Checks for Doors and Entry Control Martyn’s Law Enhanced Tier: Physical Measures and the Specifier Brief Martyn’s Law Standard Tier: Procedures, Doors and Shutters Martyn’s Law Timeline and the SIA Regulator Martyn’s Law: what premises must do and which physical measures to consider Master Key Systems MRI and RF shielded rooms: how they work and what to specify Museum Security Doors NPSA Catalogue of Security Equipment (CSE) Explained NPSA Forced Entry and Blast Guidance for Government Sites NPSA Guidance on Lockdown and Marauding Attack: What It Asks of Doors and Entrances Office Security Doors Optician Security Doors Explained Panic Hardware PAS 24 requirements for doors and windows explained PAS 68 Bollard Foundations Explained PAS 68 bollards: ratings, spacing and cost factors PAS 68 vs IWA 14 vs ISO 22343: hostile vehicle mitigation standards explained Pawnbroker Security Doors Explained Pedestrian Gates Petrol Station Security Doors Pharmacy Security Doors Planning Permission for Security Shutters, Gates and Bollards on Commercial Premises Plant room doors: fire, security and ventilation requirements Plant Room Fire Doors Port Security Doors Post Office Security Doors Explained Powder coating vs galvanising vs paint for steel Preliminary Market Engagement for Security Doors and HVM Prison Security Doors Programming a Security Door and Barrier Package on a Live Site Public-Sector Tender Response Checklist for Security Door and HVM Supply Reading a PAS 24 and SBD Door Test Report Regulation 38 Fire Safety Information at Handover for Fire-Rated Security Doorsets Replacing Security Doors in an Occupied Building Restaurant Security Doors Retail Security Doors Revolving Doors RF shielding standards and how shielded rooms are tested Rising Bollard Cost Factors Road Blocker Cost Factors Explained Road Blockers Explained Roller Shutter Cost Factors: What Drives the Price Roller shutter regulations in the UK: safety and maintenance Safe room and panic room doors: specification basics Safety Duties for Powered Doors, Gates and Barriers on Commercial Sites School Security Doors Sectional Doors Secured by Design explained: is it mandatory for doors? Secured by Design vs NPSA vs LPCB: Which One You Need Security Door Locks Security Door Maintenance Checklist Security Doors and Access for Everyone: What Approved Document M Asks Security Doors for A and E Departments Security Doors for Badminton Clubs Security Doors for Bowling Alleys Security Doors for Bowls Clubs Security Doors for Climbing Centres Security Doors for Cricket Clubs Security Doors for Dialysis Centres Security Doors for Golf Clubs Security Doors for Hockey Clubs Security Doors for Ice Rinks Security Doors for Maternity Units Security Doors for Mental Health Units Security Doors for Oncology Units Security Doors for Operating Theatres Security Doors for Rehabilitation Centres Security Doors for Snooker Clubs Security Doors for Squash Clubs Security Doors for Swimming Pools Security Doors for Tennis Clubs Security Doors for Walk-in Centres Security Doors West Midlands Explained Security Fencing Security Gates Cost Factors Explained Security shutters vs high performance roller doors Security shutters vs retractable grilles: which suits retail and commercial openings? Security Turnstiles Explained Security Window Film Security Windows for Schools Explained Self Storage Security Doors Server Room Doors Explained Shopping Centre Security Doors Smoke Control Doors Explained Smoke Curtains Specification Mistakes When Mixing LPS 1175, PAS 24 and SBD in One Tender SR2 vs SR3 vs SR4 security doors: choosing the right LPS 1175 level Stadium Security Doors Steel Door Frames Steel vs aluminium security doors: strength, ratings and looks Steel vs timber fire doors: which suits your building? Student Accommodation Security Doors Substation doors: security, ventilation and specification Supermarket Security Doors Telescopic Bollards Tender Evaluation Criteria and Scoring for Security Doors and HVM The Scope of a Maintenance Contract for Security Doors and Barriers Theatre Security Doors Thermal and Weather Performance of External Security Doorsets Thermally broken steel security doors: U-values and certification Traffic Calming as Hostile Vehicle Mitigation Transport hub security requirements Turnstile Cost Factors Explained Turnstile vs speed gate vs security portal: choosing entrance control Types of security doors for commercial buildings University Security Doors Explained Vehicle Dynamics Assessment: What It Tells the Buyer Before a Barrier Is Specified Warehouse Security Doors Explained Warehouse Security Gates Warranty, Defects Liability and Guarantees for Security Doors and Barriers What affects the cost of a bullet resistant door What affects the cost of a high-security door in the UK Window Security Bars View all →

Products

One supplier for the whole building envelope

Ready to specify your project?

Free assessment, written specification and test evidence. Reply within one working day.