Fire Door Rules for Badminton Clubs
Badminton clubs fill one indoor hall through the evening, with changing rooms and a bar beside the courts, so each door takes the period its room asks for.
- ✓Third-party test evidence with every product
- ✓Written specification you can issue to tender
- ✓Supplied and installed across the UK
Get a free project quote
Rating, written specification and budget range within one working day.
Confidential. No cost, no obligation.
Third-party tested
Evidence with every quote
UK manufactured
Made to your sizes
One accountable team
Specify, supply, install
Confidential handling
Details never shared
A badminton club entrance leaf takes FD30 to EN 1634-1, and the sports hall, the changing rooms and the bar take the same period, while the kitchen, the back office and the plant room take FD60.
EN 1634-1 tests a leaf against fire and counts the minutes, from FD30 to FD120, and the letters beside the minutes name what the leaf stops, with E for flame, EW for flame and part of the heat, and EI for flame and heat together.
A badminton club plays inside one hall, where courts fill through the evening and players move between the hall, the changing rooms, the store and the bar, so each leaf round that hall takes the period that fits the room behind it.
- FD30 / FD60Periods to EN 1634-1
- Sports hallOne hall beside indoor courts
- KitchenWhere FD60 holds the heat
- One routeFrom the courts to the car park
The badminton club order: one period beside each leaf
The order names seven leaves, and the period beside each one follows the room that sits behind it, so the entrance, the sports hall, the changing rooms and the bar sit at FD30, and the kitchen, the back office and the plant room sit at FD60.
Four of the seven leaves sit at FD30, a thirty minute hold, because the rooms behind them stay full of players from the first game to the last, and the other three sit at FD60, a sixty minute hold, because the rooms behind them hold food stores, records or plant.
Each leaf on the order carries its own line, with the room, the period, the grade and the closer written beside it, so the fitter, the manager and the person who signs the order all read the same list.
| Room | Period | Grade | What to check |
|---|---|---|---|
| Entrance | FD30 | B3 | Leaf, closer, seals |
| Sports hall | FD30 | B3 | Leaf, closer, seals |
| Changing rooms | FD30 | B3 | Leaf, closer, seals |
| Bar | FD30 | B3 | Leaf, closer, seals |
| Kitchen | FD60 | C5 | Leaf, closer, seals |
| Back office | FD60 | C5 | Leaf, closer, seals |
| Plant room | FD60 | C5 | Leaf, closer, seals |
A doorset can carry fire minutes from EN 1634-1 beside a forced entry grade from LPS 1175 Issue 8.2, so one leaf can hold FD30 or FD60 and B3 or C5 at once. The dual doorset guide shows how the fire test and the forced entry test sit on the same leaf.
Kitchen, back office and plant room: FD60 behind shut leaves
A period is proved on the whole doorset, not on the leaf alone, so the leaf, the frame, the seals and the closer all carry the hour together, and a leaf that is swapped without its frame loses the minutes its report promises.
FD60 sits on the kitchen leaf, which stays shut between services, because the food stores behind it feed the bar all evening and the leaf has to hold the heat back while the kitchen is empty.
The back office leaf takes FD60 as well, because the membership records and the keys to every other room sit behind it, and the plant room leaf takes FD60 because the pumps and the boards that keep the hall lit and warm sit behind that one. The plant room fire door guide covers the leaf that guards the plant.
The plant room leaf stays shut between visits, because the pumps and the boards behind it run without anyone watching them, and a leaf that stands open lets heat and smoke reach the plant before anyone knows the fire has started. Only the person who holds the plant room key opens that leaf, and the leaf is shut again before the key goes back.
Entrance and sports hall: FD30 on the way in and the way out
FD30 sits on the entrance leaf, the sports hall leaf, the changing room leaves and the bar leaf, because those four leaves sit on the way out, and thirty minutes is the time the route needs while players leave the hall together.
Where players leave together after the last game, a push bar proved to BS EN 1125 runs across no less than 60 percent of the leaf width on any leaf that serves more than 60 people, so the leaf opens under a crowd without a key or a code. The panic hardware guide and the emergency exit guide cover the bars and the leaves that carry them.
A glazed panel in the sports hall leaf lets staff watch the courts without opening the leaf, so the hall keeps its view of the play while the leaf stays shut on the route out. The vision panel guide covers the glass that sits in a fire leaf and the beads that hold it.
Smoke on the route past the changing rooms: Sa and S200
Players leaving the courts meet smoke before they meet flame, so the leaves on the route past the changing rooms carry a smoke rating to BS EN 1634-3, with Sa for smoke at room temperature and S200 for smoke at 200 degrees.
A leaf that stands open through the day hangs on a hold-open device that lets go when the alarm sounds, so the leaf shuts on its own and the smoke stays on one side of it. The closer guide covers the closers that shut the leaf, and the smoke control guide covers the leaves that hold smoke back.
Smoke moves down a corridor while players are still gathering rackets and bags, so the leaves on the route shut before the smoke reaches the hall, and the rooms on either side of the route stay apart. The compartmentation guide covers how those leaves split the building into parts that hold fire and smoke apart.
Closers, seals and gaps: what the badminton club periods rest on
An FD60 leaf keeps its hour only when the closer shuts it, the seals meet the frame, and the gaps round the leaf stay at 4 mm, because a leaf that stands ajar gives its minutes away before the fire reaches it. The gap guide covers the 4 mm gap and how it is measured.
The seal in the groove swells shut once the heat passes 200 degrees and keeps swelling to 250 degrees, so the gap round the leaf closes as the fire grows. The seal guide covers the seals that swell in the heat and the smoke seals that sit beside them.
A hinge proved to BS EN 1935 is tested through 200,000 cycles, with grade 13 rated for 120 kg and grade 14 rated for 160 kg, and a closer proved to BS EN 1154 runs from EN 1, the smallest power size, to EN 3, the smallest size that may sit on a fire door. The hardware guide covers the hinges, the closers and the locks that hold a fire leaf together.
A fire leaf has to open under a light hand as well as shut on its own, because a player with a racket in one hand and a bag in the other still has to get through it. BS 8300 and Approved Document M put the opening force below 30 N through the first 30 degrees and below 22.5 N beyond that, so the closer that shuts the leaf must not make the leaf too heavy to push.
Evening play and the way to the car park: getting players out after dark
The route to the car park is signed at every turn, because the alarm may sound while the hall is full and players have to find the way out without asking. The signage guide covers the signs that sit on the leaf and along the route.
Martyn’s Law received Royal Assent in April 2025 and is expected to go live in spring 2027, with tiers for premises that hold 200 to 799 people and for premises that hold 800 or more, so a club that fills its hall through the evening needs to know which tier it sits in. The Martyn’s Law guide covers the tiers and what each one asks of a venue.
Outside the club, the car park needs the same thought as the route, because players gather there after the alarm sounds. ProtectUK puts the clear gap between bollards at no more than 1,200 mm and their height at no less than 500 mm, and the bollard guide covers the posts that guard the front of the building.
When the alarm sounds during evening play, the duty steward walks the hall and the changing rooms to make sure no one is left behind, while the bar staff clear the bar and the tables. The walk only works when the leaves on the route shut behind the steward, so the route stays clear and the smoke stays on one side of each leaf while the club empties.
Bar and changing rooms: FD30 where players rest and change
The bar leaf takes FD30, because players eat and drink in the bar between games and the leaf has to hold the heat back while they leave through the hall and out to the car park.
The changing room leaves take FD30 as well, because players change there between games and the store beside the courts holds the nets, the posts and the spare rackets, so the leaves round those rooms hold for thirty minutes while the rooms empty.
A bar in a restaurant asks for the same period on its leaves, and a bowling alley keeps the same hours as a badminton club, with play and drink running side by side into the evening. The restaurant fire door guide and the bowling alley fire door guide cover how those rooms take FD30, while the leisure centre guide and the gym fire door guide cover buildings where the hall is only one part of the play.
Period, grade and proof: putting the badminton club fire order on one list
The order gives every leaf a line of its own, with the room, the period, the grade and the closer written beside it, and the line is read back against the room before the order is signed, so no leaf goes in with the wrong minutes.
Every leaf on the order is checked before the order is signed, because a closer that will not shut the leaf and a seal that will not meet the frame both take the minutes off the leaf. The certification guide covers the proof that sits behind each leaf, and the specifying guide covers the leaf, the frame and the hardware as one doorset.
Once the club opens, the manager goes round with the door list and tries each leaf in turn, and a leaf that will not shut goes on the list the same day. The inspection checklist covers what to try on each leaf, and the maintenance guide covers the work that keeps the leaves shutting as they should.
Put the period, the grade and the closer on one line for each leaf, and read that line back against the room before the order goes in.
What period should a badminton club plant room door carry?
FD60 to EN 1634-1, because the plant room holds the pumps and the boards that keep the hall lit and warm.
What period should a badminton club entrance door carry?
FD30 to EN 1634-1, because the entrance leaf sits on the way out to the car park.
Can a badminton club leaf hold a fire period and a security grade?
Yes, a single doorset can carry minutes against fire beside a grade against forced entry, with both results on one report.
Do badminton club fire doors need a smoke rating?
Yes, the leaves on the route from the courts to the car park carry Sa or S200 to BS EN 1634-3, so smoke stays behind the leaf while players leave.
What happens when a fire door will not shut?
A leaf that will not shut goes on the door list the same day, and the leaf stays on that list until the closer or the seals let it shut again.