Fire Door Rules for Swimming Pools
A pool fills its hall with swimmers who move slowly when wet, so each door takes the fire period its room demands, FD30 on the route out and FD60 behind it.
- ✓Third-party test evidence with every product
- ✓Written specification you can issue to tender
- ✓Supplied and installed across the UK
Get a free project quote
Rating, written specification and budget range within one working day.
Confidential. No cost, no obligation.
Third-party tested
Evidence with every quote
UK manufactured
Made to your sizes
One accountable team
Specify, supply, install
Confidential handling
Details never shared
A swimming pool fills its hall with swimmers who move slowly when wet, and the fire rules for the building follow the rooms behind each leaf. The entrance, the cash desk, the pool hall and the changing rooms take FD30, and the plant room, the chemical store and the staff office take FD60, because the rooms behind the front hold the plant, the chemicals and the records, and those rooms ask for a longer hold than the route out.
The number after FD counts minutes, and the minutes come from EN 1634-1, which runs from 30 to 120. E marks a leaf that held flame on its own, EW a leaf that held flame with some of the heat, and EI a leaf that held flame with the heat as well, so the number counts the minutes and the letter says what stayed back.
A swimming pool follows the same fire rules as any other building where people move slowly and some have never used the building, and the period on each leaf follows what sits behind it and how fast the people behind it can move. The fire door regulations leisure centres guide covers the fire rules for a building that holds sports halls beside its pool, and the fire door regulations gyms guide covers the rooms of a building that holds studios and machines, while a swimming pool sets its leaves by the pool hall and the rooms behind it.
- FD30 / FD60Fire periods to EN 1634-1
- Pool hallWhere FD30 holds the hall clear
- Sa / S200Smoke ratings to BS EN 1634-3
- One listEvery pool door named
Seven rooms in a swimming pool: the period each leaf takes
Seven rooms make up a swimming pool, and the period follows what each room holds. Swimmers come in through the entrance, pay at the cash desk, swim in the pool hall, change in the changing rooms, and the plant room keeps the water moving, the chemical store holds the chemicals, and the staff office holds the records.
FD60 sits on the plant room, the chemical store and the staff office, because the plant, the chemicals and the records behind those leaves need sixty minutes before flame reaches them. FD30 sits on the entrance, the cash desk, the pool hall and the changing rooms, because the people on that route reach the street in far less than thirty minutes.
Every opening gets its own line on the order, with the leaf and the period beside it, so no leaf is hung on guesswork. The table sets out the seven rooms with the period each one takes and the grade beside the period, so the fitter can match each leaf to its line as it is hung.
| Room | Period | Grade | What to check |
|---|---|---|---|
| Entrance | FD30 | B3 | Leaf, glass, closer |
| Cash desk | FD30 | D10 | Leaf, glass, closer |
| Pool hall | FD30 | B3 | Leaf, glass, closer |
| Changing rooms | FD30 | B3 | Leaf, lock, closer |
| Plant room | FD60 | C5 | Leaf, lock, seals |
| Chemical store | FD60 | C5 | Leaf, lock, seals |
| Staff office | FD60 | C5 | Leaf, lock, seals |
What the two periods hold back in a swimming pool
A fire period counts the minutes the doorset earned in its test, where the doorset means the leaf, frame, fixings and lock proved as one. The order writes the period beside the leaf, and the fire door certification guide names what the report behind a period must hold.
One doorset in the pool can carry the fire proof and the forced entry proof in a single report. EN 1634-1 gives the fire minutes, and LPS 1175 Issue 8.2 of September 2024 gives the forced entry grade in B3, C5 and D10, while the fire and security doors dual certification guide shows the pair proved on the same leaf.
Damp air from the pool hall works on the seals and the closers through the day, so the leaves on the pool hall are checked for rust and for seals that have gone soft on the monthly walk round the pool. A leaf that has swollen with damp will not shut, and a leaf that will not shut holds no period at all.
FD60 on the plant room, chemical store and staff office
Behind the plant room leaf sit the boards and the equipment that keep the water moving and the air fresh, so the leaf takes FD60 because the boards behind it feed the whole pool. The plant room fire doors guide covers the leaves of a plant room in full.
Behind the chemical store leaf sit the dosing chemicals, so the leaf takes FD60 and stays shut and locked whenever no one is working inside. The staff office leaf takes FD60 as well, because the membership records behind it cannot be remade once flame reaches them. Each leaf is shut as the last person leaves the room, because an open leaf holds back no flame at all.
The pool hall: FD30 to hold the hall clear
Swimmers in the pool hall move slowly when the alarm sounds, because some of them are in the water, some are wet underfoot and some have never used the building, so the pool hall leaf takes FD30 to hold the hall clear while staff reach the swimmers. Thirty minutes is more than staff need to clear a hall of swimmers, and the leaf gives them that time with the hall still clear of flame.
Staff see the pool hall through a glazed panel in the leaf, so the leaf stays shut while the swimmers are watched. The panel is tested with the leaf round it, so the report names the glass, the bead and the fixings together. The fire door vision panels guide names which panels a fire leaf may carry, and the steel vs timber fire doors guide sets the two leaf materials beside each other.
The pool hall leaf carries FD30 beside the grade the room demands, and its hardware was proved with the leaf, so no fitting fitted later takes the period off it.
Entrance, cash desk and changing rooms: FD30 on the route swimmers use
The entrance leaf, the cash desk leaf and the changing room leaf all take FD30, because swimmers pass through them on the way out. Thirty minutes is more than the people on that route need to reach the street.
Where the route serves more than 60 people, a push bar proved to BS EN 1125 runs across the leaves on the way out, and the bar covers no less than 60 percent of the leaf width. A swimmer reaching the leaf with people behind them opens it with one push, and the bar works whether the supply to the building is on or off. The panic hardware guide sets out what the bar must do when people push against the leaf, and the emergency exit doors guide covers the leaves on the way out.
The alarm may sound while swimmers who have never used the building are still in the pool hall, so the route to the street is signed at every turn and nothing stands on it. A leaf on the way out must still open to a push from a swimmer with wet feet, and BS 8300 with Approved Document M puts the push below 30 N through the first 30 degrees of swing and below 22.5 N beyond that.
Smoke in the pool hall: Sa and S200 beside the period
Swimmers leaving the pool hall meet smoke before flame, so the leaves on the way out carry a smoke rating beside their fire period. BS EN 1634-3 gives the two smoke ratings, Sa for smoke at room temperature and S200 for smoke at 200 degrees. How the route leaves keep the smoke back while the swimmers move past them is worked through in the smoke control doors guide. Lessons bring children into the hall in groups, and the leaves on their route out carry the smoke rating too.
A leaf that needs to stand open while the pool is busy is held by a device proved to BS EN 1155, and the device lets the leaf go on its own the moment the alarm sounds. How the leaves hold the line between one part of the pool and the next is set out in the fire compartmentation guide, and a wedge under a leaf gives it no period at all while it stands open, so the wedge is never the device that holds a fire leaf.
Closers, seals and gaps: what the pool period rests on
An FD60 leaf holds its hour only when the closer shuts it, the seals meet the frame and the gaps stay narrow, because flame slips through a leaf left ajar in seconds and through a wide gap soon after. Its closer carries a proof to BS EN 1154, EN 1 is the smallest power size the standard names, and EN 3 is the lowest size a fire door takes.
Once the temperature at the frame passes 200 degrees and before it reaches 250, the seal grows across the gap, and the swollen seal blocks flame and hot gas from slipping past the leaf. Round a hung leaf the gap is 4 mm, and a gauge held against it on the monthly walk shows at once when the gap has opened wider. The intumescent seals guide covers fitting the seal, the fire door closers guide covers what the closer must do, and the fire door gaps guide covers measuring the gaps.
Hinges on a fire leaf carry a proof to BS EN 1935, grade 13 through 200,000 cycles under a leaf of 120 kg and grade 14 through 200,000 cycles under a leaf of 160 kg, so the hinge suits the weight of the leaf it carries. What each sign on a fire door must say is named in the fire door signage guide.
The swimming pool fire door order: every leaf, its period and its proof
One list holds the whole fire door order, with a line for every opening that names the leaf, the period, the lock and the closer beside it. One leaf named for the whole pool leaves the fitter to guess.
Every leaf on the order is read before the order is signed, because a closer that arrives after the doorset holds the job up, and a leaf with no line beside it cannot be checked on arrival. What the order must hold for every door is named in the how to specify security doors guide.
The duty manager takes the door list round the pool each month and works each leaf in turn. A dragging leaf, a closer that leaves the leaf standing open or a seal that has been painted over goes beside its own door on the list the day it is found, so the fault is put right before the leaf is asked to hold. The fire door inspection checklist sets out what to look for on each leaf, and the fire door maintenance guide covers the work that keeps the leaves holding.
The period on a swimming pool leaf follows the room behind it, so the FD60 and FD30 leaves sit on the same list as the grade and the lock for each leaf.
What period should a swimming pool chemical store door carry?
FD60 to EN 1634-1, because the dosing chemicals sit behind the chemical store leaf, and sixty minutes is the hold that room asks for.
What period should a pool hall door carry?
FD30 to EN 1634-1, because the pool hall leaf holds the hall clear while staff reach the swimmers, and half an hour is the hold that room demands.
Can one leaf hold fire and forced entry?
Yes, where one leaf earned its period and its grade in the two tests, so a single report carries both together.
Do swimming pool fire doors need a smoke rating?
Yes, Sa or S200 to BS EN 1634-3 sits beside the period on the leaves of the way out, because smoke reaches the swimmers leaving before flame does.
What happens when a fire door will not shut?
A leaf that will not shut goes beside its own door on the list the day the fault is found, and the pool does not wait for the next look round before the leaf is put right.
Get a free quote
Related
More in guides for specifiers
Products
One supplier for the whole building envelope
Ready to specify your project?