Certified physical security

ArxBridge
Steel door sample in a security test frame with an assessor in a UK test laboratory

ArxBridge

Security Doors for Maternity Units

A maternity unit holds mothers and newborns through the night with a drugs store on the ward, so each leaf takes the LPS 1175 grade its room demands.

  • ✓Third-party test evidence with every product
  • ✓Written specification you can issue to tender
  • ✓Supplied and installed across the UK
Prefer to talk?+44 7352 267239

Get a free project quote

Rating, written specification and budget range within one working day.

ArxBridge Quote Form

Confidential. No cost, no obligation.

Third-party tested

Evidence with every quote

UK manufactured

Made to your sizes

One accountable team

Specify, supply, install

Confidential handling

Details never shared

A maternity unit keeps mothers and newborn babies in the building through the night, and the leaves round the ward draw the line between the rooms any visitor may enter and the rooms only staff may open. Births happen in the delivery rooms, mothers rest with their babies on the postnatal ward, and a drugs store stands on the same corridor, so the entrance, the reception desk and the ward entrance sit in front of rooms that ask for a shut leaf at all hours.

Minutes sit behind every grade on a maternity leaf, and Issue 8.2 of LPS 1175, published in September 2024, counts them by timing the leaf, the frame and the lock together against the tools the test names. Three minutes sit behind B3, five behind C5 and ten behind D10, while the older names SR2, SR3 and SR4 line up with B3, C5 and D10 in that order.

A maternity unit is not a hospice, because babies are born here rather than people receiving end-of-life care, and it is not a general hospital ward, because births and newborns fill the rooms rather than patients of every kind. It is not a care home either, because mothers stay for days after a birth rather than living in the building for years. The fire door rules for care homes name the fire rules for a home where residents live for years, and the hospital security doors guide grades the leaves round wards where treatment happens through the day.

  • B3 / C5 / D10Grades to LPS 1175 Issue 8.2
  • Drugs storeWhere D10 sits on the ward
  • Mothers and newbornsThrough the night on the ward
  • One listEvery maternity leaf named

Seven openings on a maternity unit: a grade beside each room

Seven openings make up the maternity order, and the grade beside each one follows what waits behind the leaf. Mothers and visitors come in through the entrance, reception watches the ward entrance, and the delivery rooms, the postnatal ward, the drugs store, the staff office and the plant room sit behind leaves the public never passes.

The entrance, reception and the postnatal ward all take B3, a three minute hold that fits leaves in sight of staff through the day. Delivery rooms, the staff office and the plant room take C5, five minutes for rooms that stand empty between uses and hold things worth carrying away. D10 goes on the drugs store alone, ten minutes for the most portable stock on the unit, and that leaf stays locked whenever the store stands empty.

Each opening gets a line of its own on the order, with the leaf, the grade and the minutes written beside the room, and the fitter works down that list as each leaf is hung. The table below puts the seven rooms beside their grades and their minutes.

Room Grade Minutes What to check
Entrance B3 3 Leaf, lock, closer
Reception B3 3 Leaf, lock, seals
Delivery rooms C5 5 Leaf, lock, reader
Postnatal ward B3 3 Leaf, lock, closer
Drugs store D10 10 Leaf, lock, hinges
Staff office C5 5 Leaf, lock, reader
Plant room C5 5 Leaf, lock, seals

One leaf can carry fire minutes as well as a forced entry grade, and a single report can name both proofs for the same doorset. EN 1634-1 counts the fire minutes from 30 to 120, with E for flame alone, EW for flame with part of the heat and EI for flame and heat together. The dual certification guide for fire and security doors shows the pair proved on one leaf, the LPS 1175 Issue 8 explained guide sets out what Issue 8.2 changed, and the SR2 vs SR3 vs SR4 guide puts the older names beside the new grades.

At the ward entrance: B3 with a newborn behind the leaf

Partners and family arrive at all hours with bags and a pushchair, and the entrance leaf opens and shuts for people with both hands full rather than for one person at a time. A closer that brings the leaf home gently keeps the corridor quiet for mothers resting a few steps away.

The ward entrance is the point where a newborn leaves the ward, so the leaf there matters more than any other public leaf in the building. A reader beside the leaf opens only for the cards the list names, and the reception desk watches everyone who passes through it. The door entry systems guide covers the panels and readers that guard an entrance like this, and the automatic doors guide covers leaves that open for a pushchair without a hand on them.

Reception keeps the entrance in sight through the day, which is why a three minute hold fits there, and the time lets staff shut the inner leaf and call for help before anyone reaches the ward. A thumb turn on the inside lets the last person out secure the leaf at night without a key in hand. The emergency exit doors guide covers the leaves on the way out when the alarm sounds.

Need this specified for your project?Free rating, written specification and budget range within one working day.
Get a free quote

Delivery rooms behind C5: quiet, shut and watched

A birth happens behind a shut leaf, and the delivery room leaf takes C5 because the room holds drugs, equipment and notes while it stands empty between births. The leaf stays shut while a birth is under way, and only the midwife opens it for the mother and her partner.

Equipment in a delivery room is light enough to carry, and the notes beside it name the mother and the baby, so a leaf left open hands a passer by both. A reader beside the leaf opens only for the cards the list names, and the access control doors guide covers the readers and cards that guard a room like this.

Five minutes is the hold a delivery room leaf takes, because the room stands empty between births and unwatched while the midwives are elsewhere on the ward. The closer brings the leaf home after each person through, so nobody leaves the room standing open by mistake.

Postnatal ward leaves: B3 for mothers who move slowly

Mothers on the postnatal ward have just given birth, and many cannot move quickly, so the ward leaf must shut for privacy yet open for a midwife without delay. A thumb turn on the ward side lets a mother shut the leaf without a key, while a key on the corridor side lets staff open it.

A small glazed panel set high in the ward leaf lets a midwife look in without opening the leaf and waking a mother and her baby, and the bed stays out of sight below the panel. The fire door vision panels guide names the panels a leaf may carry.

A mother on the ward may push a leaf while carrying her baby or leaning on a chair, so the leaf must move under a light hand. BS 8300 and Approved Document M set the push below 30 N while the leaf moves through its first 30 degrees, and below 22.5 N once it has passed them.

Drugs store: D10 and no glass in the leaf

The drugs store holds the drugs given to mothers through the day and the night, and its leaf takes D10, the longest hold LPS 1175 Issue 8.2 names. The doorset is proved as one piece, leaf, frame and lock together, and the report states the ten minute hold against the tools the test names.

The drugs store leaf carries no glass, because a pane would let the corridor see what is kept behind it and give a hand a route to the lock, so solid steel runs from edge to edge. Hinges proved to BS EN 1935 carry the weight, grade 13 taking 120 kg and grade 14 taking 160 kg, each proved through 200,000 cycles.

A 1 star cylinder and a 2 star handle join under TS 007 into a 3 star set, so the pair is ordered together rather than apart. The midwife in charge keeps the key, and the list beside the leaf names who else may open it. The same leaf guards the stock in a pharmacy, as the pharmacy security doors guide shows, and a GP surgery fits it too, as the GP surgery security doors guide shows.

Staff office and plant room: C5 where the unit is run

Keys to every other room and records naming each mother and baby sit in the staff office, so its leaf takes C5 and stays locked when the room stands empty. An open office would hand a passer by the keys to the rest of the unit.

The plant room holds the boards and the equipment that keep the lights, the heating and the call system running, and its leaf takes C5 because a stranger through it reaches the boards that feed the whole unit. The plant room leaves are covered in full by the plant room door requirements guide, and the lock each leaf must carry is named in the security door locks guide.

Both rooms sit down the far end of the corridor, past the rooms visitors use, and the evening round reaches their leaves last.

Cards, keys and the night: who may open a maternity leaf

Mothers stay for days, and staff change across shifts, so the keys and the cards must follow the people on duty. A key plan gives each holder the rooms their own work needs and no other room, as the master key systems guide shows, and the lock each leaf in that plan must carry is named in the security door locks guide.

The midwife in charge holds a key that opens every leaf in the clinical corridors, while the midwives hold keys that open only the delivery rooms and the staff office. A mother holds no key to any staff room, and the ward key opens only her own room. A lost card is struck from the list the same day it is reported.

From the first leaf to the last, the order is taken step by step in the 10 steps to specify an LPS 1175 door guide.

Placing the maternity unit order: leaf, grade and lock on one line

One list carries the whole order, a line for every opening with its leaf, grade, lock and closer written beside the room. Without a line of its own a leaf may be hung in the wrong room, and a C5 leaf on the drugs store would hold for five minutes where ten is asked for.

The unit manager walks the building with the door list once a month, working each leaf in turn. A leaf that drags, a bolt that misses its keep or a closer that leaves a leaf standing open goes on the list against its own door the same day. What the walk should cover is named in the security door maintenance checklist.

How the frame holds the leaf and the lock together is named in the steel door frames guide, and what can take a rating away is named in the guide to keeping an LPS 1175 rating valid.

Send the leaf, the lock and the closer as one set for each room, and match the set to its room before anything is hung.

What grade should a maternity unit entrance door carry?

B3 to LPS 1175 Issue 8.2, a three minute hold, because reception watches the entrance through the day.

What grade should a maternity unit drugs store door carry?

D10 to LPS 1175 Issue 8.2, a ten minute hold for the drugs kept behind a shut leaf.

What grade should a maternity unit delivery room door carry?

C5 to LPS 1175 Issue 8.2, because the delivery room leaf is shut while births happen, and five minutes is the hold that room asks for.

Can one leaf hold fire and forced entry?

Yes, where one doorset passed both the fire test and the forced entry test, so a single report names its period and its grade.

Who checks the maternity unit doors?

The unit manager goes round with the door list once a month and works every leaf, so a fault is found and put right before the leaf is asked to hold.

Specifying security doors for a maternity unit?Send the door list with the grade each room must hold for a tested door quotation.
Get a free quote

Related

More in guides for specifiers

10 mistakes when specifying certified security doors 10 steps to specify an LPS 1175 door Acceptance and Snagging of a Security Door or Barrier Job Access Control Doors Acoustic Doors: Ratings and Specification After a Forced Entry Attempt: Checking a Security Door Airport Security Doors Anti-Ligature Doors for Mental Health Wards Anti-Ram Bollards Anti-ram gates and barriers: protecting vehicle entrances Arcade Security Doors Explained Automatic Doors Automatic Gates Cost Factors Automatic Vehicle Barriers Ballistic Panels Bank Security Doors Bingo Hall Security Doors Explained Blast doors: glazed vs solid and how they are rated Blast protection window film: what it does and what it cannot do Blast resistant windows: what drives the cost and how to specify them Bollard Cost Factors Explained Bollard regulations in the UK: spacing, height and depth Bookmaker Security Doors Explained Builders Merchant Security Doors Bullet Resistant Glass Cost Factors Bullet resistant glass ratings explained: BR1 to BR7 and SG classes Bullet resistant vs bulletproof glass: what the difference means Buying Security Doors and HVM Through Public Frameworks Car Park Security Doors Explained Car Showroom Security Doors Casino Security Doors Explained CDM 2015 Duties When Security Doors, Shutters or HVM Are Installed Cinema Security Doors Cleanroom Doors Cold Store Doors College Security Doors Commissioning, Handover and the O&M Manual for Security Doors and HVM Communal entrance doors for flats: Secured by Design and what to specify Community Centre Security Doors Control Room Doors Court Security Doors Crash Rated Fences and HVM Fencing Explained Data centre physical security: doors, glazing, HVM and shielding by zone Dental Practice Security Doors Depot Security Doors Explained Door Entry Systems Due Diligence When Selecting Vehicle Security Barriers Emergency Exit Doors EMP Shielding Cost Factors Explained Exhibition Centre Fire Door Rules Exhibition Centre Security Doors Factory Security Doors Faraday cage vs RF shielded room: what a business needs FB4 vs FB6 vs FB7: how to choose a ballistic rating Fire and security doors: how dual certification works Fire Compartmentation Fire Curtains Fire Door Certification Fire Door Closers Explained Fire Door Cost Factors Fire Door Duties of the Accountable Person Fire Door Gaps Fire Door Hardware Explained Fire door inspection checklist for steel and timber doors Fire Door Maintenance Fire Door Regulations Care Homes Fire Door Regulations for A and E Departments Fire Door Regulations for Airports Explained Fire Door Regulations for Bowls Clubs Fire door regulations for commercial buildings in the UK Fire Door Regulations for Dialysis Centres Fire Door Regulations for Hockey Clubs Fire Door Regulations for Hospitals Explained Fire Door Regulations for Offices Explained Fire Door Regulations for Operating Theatres Fire Door Regulations for Retail Explained Fire Door Regulations for Schools Explained Fire Door Regulations for Snooker Clubs Fire Door Regulations for Stadiums Fire Door Regulations for Student Accommodation Fire Door Regulations for Warehouses Fire Door Regulations Leisure Centres Fire Door Regulations Restaurants Fire Door Remediation Programme for Housing Providers Fire Door Rules for Badminton Clubs Fire Door Rules for Bingo Halls Fire Door Rules for Bookmakers Fire Door Rules for Bowling Alleys Fire Door Rules for Car Parks Fire Door Rules for Car Showrooms Fire Door Rules for Cinemas Fire Door Rules for Climbing Centres Fire Door Rules for Colleges Fire Door Rules for Community Centres Fire Door Rules for Cricket Clubs Fire Door Rules for Dental Practices Fire Door Rules for Depots Explained Fire Door Rules for Golf Clubs Fire Door Rules for GP Surgeries Fire Door Rules for Gyms Explained Fire Door Rules for Ice Rinks Fire Door Rules for Maternity Units Fire Door Rules for Mental Health Units Fire Door Rules for Museums Fire Door Rules for Oncology Units Fire Door Rules for Opticians Fire Door Rules for Pawnbrokers Fire Door Rules for Petrol Stations Fire Door Rules for Pharmacies Fire Door Rules for Ports Fire Door Rules for Post Offices Fire Door Rules for Prisons Fire Door Rules for Rehabilitation Centres Fire Door Rules for Self Storage Fire Door Rules for Shopping Centres Fire Door Rules for Squash Clubs Fire Door Rules for Supermarkets Fire Door Rules for Swimming Pools Fire Door Rules for Tennis Clubs Fire Door Rules for Theatres Fire Door Rules for UK Arcades Fire Door Rules for UK Casinos Fire Door Rules for UK Hospices Fire Door Rules for Walk-in Centres Fire Door Signage Fire Door Vision Panels Fire Doors and Gateway 2 in Higher-Risk Buildings Fire Rated Glass Cost Explained Fire Rated Sliding Doors Explained Fire Rated Windows Cost Factors Fire Rated Windows Explained Fire Safety Enforcement Notices and Fire Doors: What the Responsible Person Must Do Flat Entrance Doors: PAS 24 and Fire Rated Forced Entry vs Ballistic vs Blast: Which Rating a Site Needs Garage Security Doors Explained Gate Automation Explained Golden Thread Records for Fire Doors GP Surgery Security Doors Explained Gym Security Doors Explained High Speed Doors HMO Fire Doors Hospice Security Doors Explained Hospital Security Doors: Wards, A&E, Plant Hospital Security Gates Hotel Fire Doors Hotel Security Doors How to choose HVM bollards: fixed, shallow mount, removable and automatic How to keep an LPS 1175 door rating valid after installation How to Specify Fire Doors in a Housing Tender How to specify security doors: a checklist for architects How to Verify a Secured by Design Listing How to Verify an LPS 1175 Certificate on Red Book Live How to Write an Operational Requirement for Physical Security HVM planters and street furniture: protection that blends in In-Service Care of Vehicle Security Barriers Installation Handover: LPS 1175 Doors and PAS 68 Barriers Intumescent Seals ISO 16933 explained: EXV and SB classes and hazard ratings ISO 22343 vehicle security barriers explained Keeping a Dual-Certified Fire and Security Door Valid in Service Laboratory Security Doors Layered Security for a Site: Deter, Detect, Delay, Mitigate, Respond Lead Times and Programme Risks for LPS 1175 Doors Leisure Centre Security Doors Library Security Doors Listed Building Fire Doors Loading Bay Doors Explained Lockdown and Access Control Hardware on an LPS 1175 Door LPS 1175 Gates and Grilles Explained LPS 1175 Issue 8 explained: from SR1 to SR8 to A1 to H20 LPS 1175 Roller Shutters LPS 1175 vs ASTM F2781 and Other US Ratings Explained LPS 1175 vs EN 1627: how UK and European burglar resistance ratings compare LPS 1175 vs PAS 24: which security standard does your door need? LPS 1175 Windows and Walling Explained Martyn’s Law and Places of Worship: What a Buyer Checks for Doors and Entry Control Martyn’s Law Enhanced Tier: Physical Measures and the Specifier Brief Martyn’s Law Standard Tier: Procedures, Doors and Shutters Martyn’s Law Timeline and the SIA Regulator Martyn’s Law: what premises must do and which physical measures to consider Master Key Systems MRI and RF shielded rooms: how they work and what to specify Museum Security Doors NPSA Catalogue of Security Equipment (CSE) Explained NPSA Forced Entry and Blast Guidance for Government Sites NPSA Guidance on Lockdown and Marauding Attack: What It Asks of Doors and Entrances Office Security Doors Optician Security Doors Explained Panic Hardware PAS 24 requirements for doors and windows explained PAS 68 Bollard Foundations Explained PAS 68 bollards: ratings, spacing and cost factors PAS 68 vs IWA 14 vs ISO 22343: hostile vehicle mitigation standards explained Pawnbroker Security Doors Explained Pedestrian Gates Petrol Station Security Doors Pharmacy Security Doors Planning Permission for Security Shutters, Gates and Bollards on Commercial Premises Plant room doors: fire, security and ventilation requirements Plant Room Fire Doors Port Security Doors Post Office Security Doors Explained Powder coating vs galvanising vs paint for steel Preliminary Market Engagement for Security Doors and HVM Prison Security Doors Programming a Security Door and Barrier Package on a Live Site Public-Sector Tender Response Checklist for Security Door and HVM Supply Reading a PAS 24 and SBD Door Test Report Regulation 38 Fire Safety Information at Handover for Fire-Rated Security Doorsets Replacing Security Doors in an Occupied Building Restaurant Security Doors Retail Security Doors Revolving Doors RF shielding standards and how shielded rooms are tested Rising Bollard Cost Factors Road Blocker Cost Factors Explained Road Blockers Explained Roller Shutter Cost Factors: What Drives the Price Roller shutter regulations in the UK: safety and maintenance Safe room and panic room doors: specification basics Safety Duties for Powered Doors, Gates and Barriers on Commercial Sites School Security Doors Sectional Doors Secured by Design explained: is it mandatory for doors? Secured by Design vs NPSA vs LPCB: Which One You Need Security Door Locks Security Door Maintenance Checklist Security Doors and Access for Everyone: What Approved Document M Asks Security Doors for A and E Departments Security Doors for Badminton Clubs Security Doors for Bowling Alleys Security Doors for Bowls Clubs Security Doors for Climbing Centres Security Doors for Cricket Clubs Security Doors for Dialysis Centres Security Doors for Golf Clubs Security Doors for Hockey Clubs Security Doors for Ice Rinks Security Doors for Mental Health Units Security Doors for Oncology Units Security Doors for Operating Theatres Security Doors for Rehabilitation Centres Security Doors for Snooker Clubs Security Doors for Squash Clubs Security Doors for Swimming Pools Security Doors for Tennis Clubs Security Doors for Walk-in Centres Security Doors West Midlands Explained Security Fencing Security Gates Cost Factors Explained Security shutters vs high performance roller doors Security shutters vs retractable grilles: which suits retail and commercial openings? Security Turnstiles Explained Security Window Film Security Windows for Schools Explained Self Storage Security Doors Server Room Doors Explained Shopping Centre Security Doors Smoke Control Doors Explained Smoke Curtains Specification Mistakes When Mixing LPS 1175, PAS 24 and SBD in One Tender SR2 vs SR3 vs SR4 security doors: choosing the right LPS 1175 level Stadium Security Doors Steel Door Frames Steel vs aluminium security doors: strength, ratings and looks Steel vs timber fire doors: which suits your building? Student Accommodation Security Doors Substation doors: security, ventilation and specification Supermarket Security Doors Telescopic Bollards Tender Evaluation Criteria and Scoring for Security Doors and HVM The Scope of a Maintenance Contract for Security Doors and Barriers Theatre Security Doors Thermal and Weather Performance of External Security Doorsets Thermally broken steel security doors: U-values and certification Traffic Calming as Hostile Vehicle Mitigation Transport hub security requirements Turnstile Cost Factors Explained Turnstile vs speed gate vs security portal: choosing entrance control Types of security doors for commercial buildings University Security Doors Explained Vehicle Dynamics Assessment: What It Tells the Buyer Before a Barrier Is Specified Warehouse Security Doors Explained Warehouse Security Gates Warranty, Defects Liability and Guarantees for Security Doors and Barriers What affects the cost of a bullet resistant door What affects the cost of a high-security door in the UK Window Security Bars View all →

Products

One supplier for the whole building envelope

Ready to specify your project?

Free assessment, written specification and test evidence. Reply within one working day.