Certified physical security

ArxBridge
Steel door sample in a security test frame with an assessor in a UK test laboratory

ArxBridge

Arcade Security Doors Explained

An arcade runs cash machines, a prize counter and evening crowds behind one entrance, so each leaf takes the LPS 1175 grade its room demands.

  • ✓Third-party test evidence with every product
  • ✓Written specification you can issue to tender
  • ✓Supplied and installed across the UK
Prefer to talk?+44 7352 267239

Get a free project quote

Rating, written specification and budget range within one working day.

ArxBridge Quote Form

Confidential. No cost, no obligation.

Third-party tested

Evidence with every quote

UK manufactured

Made to your sizes

One accountable team

Specify, supply, install

Confidential handling

Details never shared

An arcade runs rows of cash machines, a prize counter and an evening crowd behind one entrance. The entrance takes the crowd in from the street, the cash desk stands where notes change hands for tokens and prizes, and the counting room, the prize store, the back office and the plant room sit behind the machine hall where the players never go.

LPS 1175 Issue 8.2, dated September 2024, sorts a leaf by the minutes it stands against the tools the test names, and an arcade leaf takes its grade from the value behind it. B3 holds for three minutes, C5 for five and D10 for ten, and a drawing from before the rename may still name the same leaves SR2, SR3 and SR4, so the order carries both names beside each leaf.

An arcade is not a casino, because the floor holds amusement machines rather than gaming tables, and it is not a bingo hall, because no numbers are called in a hall and no books are sold. The security doors for bookmakers guide grades the doors round a betting counter that takes cash through the day, and the security doors for cinemas guide grades the doors of a venue that takes an evening crowd through one entrance, while the leaves in an arcade follow the cash desk, the machine hall and the counting room between them.

  • B3 / C5 / D10Grades to LPS 1175 Issue 8.2
  • Counting roomWhere D10 sits in the arcade
  • Prize counterWhere B3 sits in the arcade
  • One listEvery arcade leaf named

Seven rooms in an arcade: the grade each one takes

Seven rooms make up an arcade, and the grade on each leaf follows the value behind it. The entrance takes the crowd in, the cash desk holds the notes and the tokens, the machine hall holds the rows of machines, the counting room holds the takings counted after close, the prize store holds the prizes waiting to be claimed, the back office holds the keys and the records, and the plant room keeps the building running.

B3 sits on the entrance, the cash desk and the machine hall route, because those leaves stand where the floor staff and the crowd can see them. C5 goes on the back office and the plant room, because the keys, the records and the plant behind them ask for a longer hold than the entrance. The counting room and the prize store take D10, because the takings and the prizes behind them are the most portable value in the building and both leaves stay shut and locked when no one is working behind them.

Each opening takes a line of its own on the order, naming the leaf, the grade and the minutes beside it, so the leaf that arrives is checked against its own line before it is hung.

Room Grade Minutes What to check
Entrance B3 3 Leaf, lock, closer
Cash desk B3 3 Leaf, lock, seals
Machine hall B3 3 Leaf, lock, closer
Counting room D10 10 Leaf, lock, hinges
Prize store D10 10 Leaf, lock, hinges
Back office C5 5 Leaf, lock, reader
Plant room C5 5 Leaf, lock, seals

A leaf in the arcade may need to hold fire as well as forced entry, and the two proofs sit in one report for the same doorset. The fire minutes come from EN 1634-1, which counts from 30 to 120, and the letter beside the count names what the leaf kept out: E for flame alone, EW for flame with part of the heat, EI for flame and heat together. The fire and security doors dual certification guide shows the pair proved on one leaf, and the SR2 vs SR3 vs SR4 guide puts the old names beside the new grades.

The arcade entrance: one leaf for the evening crowd

Players arrive in a rush before the evening session and leave in a rush when the machines go quiet, so the entrance leaf opens and shuts for a crowd rather than for one person at a time. The closer must bring the leaf home after each person through without a slam that carries across the machine hall.

The entrance asks for three minutes because it stands in sight of the cash desk while the arcade is open, and three minutes gives the staff time to shut the cash desk leaf and raise help. A key works the lock from the street and a thumb turn works it from inside, so the last person out at closing secures the leaf with a turn of the thumb.

A glazed panel in the entrance leaf lets the cash desk staff see who stands outside before the leaf opens. The door entry systems guide covers the panels and the readers that guard an entrance, and the emergency exit doors guide covers the leaves a crowd pushes through on the way out.

Need this specified for your project?Free rating, written specification and budget range within one working day.
Get a free quote

Cash desk and prize counter: B3 where money changes hands

Notes and tokens pass over the cash desk all evening, and prizes pass over the counter beside it, while the leaf behind the desk keeps the crowd on the public side of it. The cash desk leaf suits B3 because it stands where the staff and the crowd can both watch it.

Staff pass through the cash desk leaf between the till, the prize counter and the counting room, and the leaf must let them through without letting the crowd follow. A reader beside the leaf opens it for staff cards, and the closer pulls the leaf home after each person through.

Where a serving hatch sits in the cash desk so notes and tokens can pass without the leaf opening, LPS 2081 names the grades for that opening: SRA holds for one minute and SRB for three, and the hatch takes the same grade as the cash desk leaf beside it. The LPS 2081 standard page names SRA and SRB for such openings, EN 1627 grades forced entry from RC1 to RC6, and the LPS 1175 vs EN 1627 guide sets the two tests beside each other without calling one the equal of the other.

The machine hall: B3 leaves between the rows of machines

The machine hall is the public floor of the arcade, and its leaves are the doors between the rows of machines, the cash desk and the way out. Those leaves take B3, the same grade as the entrance, because they stand in the open where the staff and the crowd can see them.

The hall leaves carry glazed panels so the staff can watch the rows of machines without opening a leaf, and the glass, the bead and the fixings are named together in the same report as the leaf round them. Machines are moved, swapped and serviced through the year, so a hall leaf must open wide enough for a machine to pass and shut again behind it.

A leaf on the machine hall route must open with one push from a player carrying tokens or a prize, so the force stays below 30 N for the first 30 degrees and below 22.5 N beyond them, to BS 8300 and Approved Document M.

Counting room and prize store: D10 behind shut leaves

The counting room holds the takings counted after close, and the prize store holds the prizes waiting to be claimed, so both leaves take D10, the longest hold LPS 1175 Issue 8.2 names. Leaf, frame, fixings and lock are proved together as one doorset, and the report names ten minutes against the tools the test names.

Glass has no place on either leaf, because a pane would let the corridor see the counting and the prizes, and give a hand a way to the lock, so both leaves are solid steel from edge to edge. Hinges proved to BS EN 1935 carry a D10 leaf, grade 13 for a leaf of 120 kg and grade 14 for a leaf of 160 kg, both proved through 200,000 cycles.

Under TS 007 a cylinder rated 1 star and a handle rated 2 star combine into a 3 star set, so the two are ordered as a pair and the cylinder on each D10 leaf is the one the test saw beside its handle. The manager holds the key to the counting room and the prize store, and the names that may open them sit on the list beside each leaf. The safe room door specification guide sets out how a room that holds value is shut, and the counting room and the prize store follow the same care with their leaves.

Back office and plant room: C5 on the rooms that run the arcade

The back office holds the keys to the other rooms and the papers that record each evening, so its leaf takes C5 and stays locked whenever the room stands empty, because an open room gives a passer by the keys to the rest of the arcade. A reader beside the leaf opens only for the cards the list names.

Boards and equipment in the plant room keep the lights, the machines and the heating running, so the leaf on that room takes C5, because a stranger through it reaches the boards that feed the whole arcade. The plant room door requirements guide covers the leaves of a plant room in full.

Cards and keys after dark: who opens which arcade leaf

After dark a small team staffs the arcade, and each leaf opens to the cards and keys of the staff on duty. The master key systems guide shows how a key plan gives each holder the rooms their own work needs and no other room, while the security door locks guide names the lock each leaf in that plan must carry.

One key in the manager’s hand opens every leaf behind the cash desk, while the cash desk staff hold keys that open only the cash desk and back office. A lost card is struck from the list the same evening it is reported. The 10 steps to specify an LPS 1175 door guide walks the order through from the first leaf to the last.

The arcade order: every leaf, its grade and its lock

The order is one list with a line for every opening, and each line names the leaf, the grade, the lock and the closer that belong in that opening. An opening with no line of its own leaves the fitter to choose.

Once a month the arcade manager takes the door list through the building and works the leaves one by one. When a leaf drags, a bolt misses its keep or a closer leaves the leaf standing open, the fault is written against its own door on the day it is found, and the security door maintenance checklist names what the walk should cover.

How the frame holds the leaf and the lock together is set out in the steel door frames guide, and what can take a rating away is named in the keeping an LPS 1175 rating valid guide.

The grade on an arcade leaf follows the value behind it, so the leaf, the lock and the closer are ordered together and checked together against the room behind the leaf.

What grade should an arcade entrance door carry?

B3 to LPS 1175 Issue 8.2, which holds for three minutes, because the entrance stands in view of the cash desk and the crowd.

What grade should an arcade counting room door carry?

D10 to LPS 1175 Issue 8.2, which holds for ten minutes, because the counting room holds the takings behind a shut leaf.

What grade should an arcade cash desk door carry?

B3 to LPS 1175 Issue 8.2, because the cash desk leaf is watched by the staff and the crowd, and three minutes is the hold a watched leaf asks for.

Can one leaf hold fire and forced entry?

Yes, where the same doorset passed the fire test and the forced entry test, so the period and the grade sit in one report beside the same leaf.

Who checks the arcade doors?

The arcade manager walks the floor with the door list each month and tries the leaves in turn, so a fault is found and put right before the leaf is asked to hold.

Specifying security doors for an arcade?Send the door list with the grade each room must hold for a tested door quotation.
Get a free quote

Related

More in guides for specifiers

10 mistakes when specifying certified security doors 10 steps to specify an LPS 1175 door Acceptance and Snagging of a Security Door or Barrier Job Access Control Doors Acoustic Doors: Ratings and Specification After a Forced Entry Attempt: Checking a Security Door Airport Security Doors Anti-Ligature Doors for Mental Health Wards Anti-Ram Bollards Anti-ram gates and barriers: protecting vehicle entrances Automatic Doors Automatic Gates Cost Factors Automatic Vehicle Barriers Ballistic Panels Bank Security Doors Bingo Hall Security Doors Explained Blast doors: glazed vs solid and how they are rated Blast protection window film: what it does and what it cannot do Blast resistant windows: what drives the cost and how to specify them Bollard Cost Factors Explained Bollard regulations in the UK: spacing, height and depth Bookmaker Security Doors Explained Builders Merchant Security Doors Bullet Resistant Glass Cost Factors Bullet resistant glass ratings explained: BR1 to BR7 and SG classes Bullet resistant vs bulletproof glass: what the difference means Buying Security Doors and HVM Through Public Frameworks Car Park Security Doors Explained Car Showroom Security Doors Casino Security Doors Explained CDM 2015 Duties When Security Doors, Shutters or HVM Are Installed Cinema Security Doors Cleanroom Doors Cold Store Doors College Security Doors Commissioning, Handover and the O&M Manual for Security Doors and HVM Communal entrance doors for flats: Secured by Design and what to specify Community Centre Security Doors Control Room Doors Court Security Doors Crash Rated Fences and HVM Fencing Explained Data centre physical security: doors, glazing, HVM and shielding by zone Dental Practice Security Doors Depot Security Doors Explained Door Entry Systems Due Diligence When Selecting Vehicle Security Barriers Emergency Exit Doors EMP Shielding Cost Factors Explained Exhibition Centre Fire Door Rules Exhibition Centre Security Doors Factory Security Doors Faraday cage vs RF shielded room: what a business needs FB4 vs FB6 vs FB7: how to choose a ballistic rating Fire and security doors: how dual certification works Fire Compartmentation Fire Curtains Fire Door Certification Fire Door Closers Explained Fire Door Cost Factors Fire Door Duties of the Accountable Person Fire Door Gaps Fire Door Hardware Explained Fire door inspection checklist for steel and timber doors Fire Door Maintenance Fire Door Regulations Care Homes Fire Door Regulations for A and E Departments Fire Door Regulations for Airports Explained Fire Door Regulations for Bowls Clubs Fire door regulations for commercial buildings in the UK Fire Door Regulations for Dialysis Centres Fire Door Regulations for Hockey Clubs Fire Door Regulations for Hospitals Explained Fire Door Regulations for Offices Explained Fire Door Regulations for Operating Theatres Fire Door Regulations for Retail Explained Fire Door Regulations for Schools Explained Fire Door Regulations for Snooker Clubs Fire Door Regulations for Stadiums Fire Door Regulations for Student Accommodation Fire Door Regulations for Warehouses Fire Door Regulations Leisure Centres Fire Door Regulations Restaurants Fire Door Remediation Programme for Housing Providers Fire Door Rules for Badminton Clubs Fire Door Rules for Bingo Halls Fire Door Rules for Bookmakers Fire Door Rules for Bowling Alleys Fire Door Rules for Car Parks Fire Door Rules for Car Showrooms Fire Door Rules for Cinemas Fire Door Rules for Climbing Centres Fire Door Rules for Colleges Fire Door Rules for Community Centres Fire Door Rules for Cricket Clubs Fire Door Rules for Dental Practices Fire Door Rules for Depots Explained Fire Door Rules for Golf Clubs Fire Door Rules for GP Surgeries Fire Door Rules for Gyms Explained Fire Door Rules for Ice Rinks Fire Door Rules for Maternity Units Fire Door Rules for Mental Health Units Fire Door Rules for Museums Fire Door Rules for Oncology Units Fire Door Rules for Opticians Fire Door Rules for Pawnbrokers Fire Door Rules for Petrol Stations Fire Door Rules for Pharmacies Fire Door Rules for Ports Fire Door Rules for Post Offices Fire Door Rules for Prisons Fire Door Rules for Rehabilitation Centres Fire Door Rules for Self Storage Fire Door Rules for Shopping Centres Fire Door Rules for Squash Clubs Fire Door Rules for Supermarkets Fire Door Rules for Swimming Pools Fire Door Rules for Tennis Clubs Fire Door Rules for Theatres Fire Door Rules for UK Arcades Fire Door Rules for UK Casinos Fire Door Rules for UK Hospices Fire Door Rules for Walk-in Centres Fire Door Signage Fire Door Vision Panels Fire Doors and Gateway 2 in Higher-Risk Buildings Fire Rated Glass Cost Explained Fire Rated Sliding Doors Explained Fire Rated Windows Cost Factors Fire Rated Windows Explained Fire Safety Enforcement Notices and Fire Doors: What the Responsible Person Must Do Flat Entrance Doors: PAS 24 and Fire Rated Forced Entry vs Ballistic vs Blast: Which Rating a Site Needs Garage Security Doors Explained Gate Automation Explained Golden Thread Records for Fire Doors GP Surgery Security Doors Explained Gym Security Doors Explained High Speed Doors HMO Fire Doors Hospice Security Doors Explained Hospital Security Doors: Wards, A&E, Plant Hospital Security Gates Hotel Fire Doors Hotel Security Doors How to choose HVM bollards: fixed, shallow mount, removable and automatic How to keep an LPS 1175 door rating valid after installation How to Specify Fire Doors in a Housing Tender How to specify security doors: a checklist for architects How to Verify a Secured by Design Listing How to Verify an LPS 1175 Certificate on Red Book Live How to Write an Operational Requirement for Physical Security HVM planters and street furniture: protection that blends in In-Service Care of Vehicle Security Barriers Installation Handover: LPS 1175 Doors and PAS 68 Barriers Intumescent Seals ISO 16933 explained: EXV and SB classes and hazard ratings ISO 22343 vehicle security barriers explained Keeping a Dual-Certified Fire and Security Door Valid in Service Laboratory Security Doors Layered Security for a Site: Deter, Detect, Delay, Mitigate, Respond Lead Times and Programme Risks for LPS 1175 Doors Leisure Centre Security Doors Library Security Doors Listed Building Fire Doors Loading Bay Doors Explained Lockdown and Access Control Hardware on an LPS 1175 Door LPS 1175 Gates and Grilles Explained LPS 1175 Issue 8 explained: from SR1 to SR8 to A1 to H20 LPS 1175 Roller Shutters LPS 1175 vs ASTM F2781 and Other US Ratings Explained LPS 1175 vs EN 1627: how UK and European burglar resistance ratings compare LPS 1175 vs PAS 24: which security standard does your door need? LPS 1175 Windows and Walling Explained Martyn’s Law and Places of Worship: What a Buyer Checks for Doors and Entry Control Martyn’s Law Enhanced Tier: Physical Measures and the Specifier Brief Martyn’s Law Standard Tier: Procedures, Doors and Shutters Martyn’s Law Timeline and the SIA Regulator Martyn’s Law: what premises must do and which physical measures to consider Master Key Systems MRI and RF shielded rooms: how they work and what to specify Museum Security Doors NPSA Catalogue of Security Equipment (CSE) Explained NPSA Forced Entry and Blast Guidance for Government Sites NPSA Guidance on Lockdown and Marauding Attack: What It Asks of Doors and Entrances Office Security Doors Optician Security Doors Explained Panic Hardware PAS 24 requirements for doors and windows explained PAS 68 Bollard Foundations Explained PAS 68 bollards: ratings, spacing and cost factors PAS 68 vs IWA 14 vs ISO 22343: hostile vehicle mitigation standards explained Pawnbroker Security Doors Explained Pedestrian Gates Petrol Station Security Doors Pharmacy Security Doors Planning Permission for Security Shutters, Gates and Bollards on Commercial Premises Plant room doors: fire, security and ventilation requirements Plant Room Fire Doors Port Security Doors Post Office Security Doors Explained Powder coating vs galvanising vs paint for steel Preliminary Market Engagement for Security Doors and HVM Prison Security Doors Programming a Security Door and Barrier Package on a Live Site Public-Sector Tender Response Checklist for Security Door and HVM Supply Reading a PAS 24 and SBD Door Test Report Regulation 38 Fire Safety Information at Handover for Fire-Rated Security Doorsets Replacing Security Doors in an Occupied Building Restaurant Security Doors Retail Security Doors Revolving Doors RF shielding standards and how shielded rooms are tested Rising Bollard Cost Factors Road Blocker Cost Factors Explained Road Blockers Explained Roller Shutter Cost Factors: What Drives the Price Roller shutter regulations in the UK: safety and maintenance Safe room and panic room doors: specification basics Safety Duties for Powered Doors, Gates and Barriers on Commercial Sites School Security Doors Sectional Doors Secured by Design explained: is it mandatory for doors? Secured by Design vs NPSA vs LPCB: Which One You Need Security Door Locks Security Door Maintenance Checklist Security Doors and Access for Everyone: What Approved Document M Asks Security Doors for A and E Departments Security Doors for Badminton Clubs Security Doors for Bowling Alleys Security Doors for Bowls Clubs Security Doors for Climbing Centres Security Doors for Cricket Clubs Security Doors for Dialysis Centres Security Doors for Golf Clubs Security Doors for Hockey Clubs Security Doors for Ice Rinks Security Doors for Maternity Units Security Doors for Mental Health Units Security Doors for Oncology Units Security Doors for Operating Theatres Security Doors for Rehabilitation Centres Security Doors for Snooker Clubs Security Doors for Squash Clubs Security Doors for Swimming Pools Security Doors for Tennis Clubs Security Doors for Walk-in Centres Security Doors West Midlands Explained Security Fencing Security Gates Cost Factors Explained Security shutters vs high performance roller doors Security shutters vs retractable grilles: which suits retail and commercial openings? Security Turnstiles Explained Security Window Film Security Windows for Schools Explained Self Storage Security Doors Server Room Doors Explained Shopping Centre Security Doors Smoke Control Doors Explained Smoke Curtains Specification Mistakes When Mixing LPS 1175, PAS 24 and SBD in One Tender SR2 vs SR3 vs SR4 security doors: choosing the right LPS 1175 level Stadium Security Doors Steel Door Frames Steel vs aluminium security doors: strength, ratings and looks Steel vs timber fire doors: which suits your building? Student Accommodation Security Doors Substation doors: security, ventilation and specification Supermarket Security Doors Telescopic Bollards Tender Evaluation Criteria and Scoring for Security Doors and HVM The Scope of a Maintenance Contract for Security Doors and Barriers Theatre Security Doors Thermal and Weather Performance of External Security Doorsets Thermally broken steel security doors: U-values and certification Traffic Calming as Hostile Vehicle Mitigation Transport hub security requirements Turnstile Cost Factors Explained Turnstile vs speed gate vs security portal: choosing entrance control Types of security doors for commercial buildings University Security Doors Explained Vehicle Dynamics Assessment: What It Tells the Buyer Before a Barrier Is Specified Warehouse Security Doors Explained Warehouse Security Gates Warranty, Defects Liability and Guarantees for Security Doors and Barriers What affects the cost of a bullet resistant door What affects the cost of a high-security door in the UK Window Security Bars View all →

Products

One supplier for the whole building envelope

Ready to specify your project?

Free assessment, written specification and test evidence. Reply within one working day.