A bingo hall is a hall of players, a cash desk and a counting room behind one entrance, and the fire rules for the building follow the rooms behind each leaf. The entrance and the cash desk take FD30, and the counting room, the back office and the plant room take FD60, because the rooms behind the cash desk hold cash, prizes and records that need a longer hold than the public route.
The minutes on a bingo hall leaf are counted by EN 1634-1, which runs from 30 to 120 and puts a letter beside the count to say what the leaf held back. E names a leaf that held flame alone, EW names a leaf that held flame with part of the heat, and EI names a leaf that held flame and heat together, so the minutes name the count and the letter names what was held.
A bingo hall follows the same rules as any other hall that takes a crowd through one entrance in the evening, and the leaf on each room takes its period from what sits behind it. The fire door regulations cinemas guide covers the fire rules for a venue that holds a crowd in the dark, and the fire door regulations leisure centres guide covers the rooms a hall keeps behind its public floor.
- FD30 / FD60Fire periods to EN 1634-1
- Counting roomWhere the period rises
- Sa / S200Smoke ratings to BS EN 1634-3
- One listEvery bingo hall door named
Five rooms in a bingo hall: the period each leaf takes
Five rooms make up a bingo hall, and the period follows what each room holds. The players come in through the entrance, the cash desk takes the notes and hands out the books, the counting room keeps the takings and the prize float counted after the session, the back office keeps the keys and the session records, and the plant room keeps the building running through the evening.
FD60 sits on the counting room, the back office and the plant room, because the takings, the papers and the boards behind those leaves need sixty minutes before flame reaches them. FD30 sits on the entrance and the cash desk, because the players on that route can reach the street in far less time than thirty minutes.
Each opening takes its own line on the order, with the leaf and the period written beside it, so no leaf is hung on guesswork and no room ends up with a leaf that holds fire for the wrong length of time. The table names the five rooms, the period each one takes and the grade beside the period, so the fitter checks each leaf against its own line as it is hung.
| Room | Period | Grade | What to check |
|---|---|---|---|
| Entrance | FD30 | B3 | Leaf, glass, closer |
| Cash desk | FD30 | B3 | Leaf, glass, closer |
| Counting room | FD60 | D10 | Leaf, lock, seals |
| Back office | FD60 | C5 | Leaf, lock, seals |
| Plant room | FD60 | C5 | Leaf, lock, seals |
What FD30 and FD60 hold back in a bingo hall
A fire period is a count of minutes the doorset earned in the test, and the doorset is the leaf, the frame, the fixings and the lock proved as one. The report states the period the doorset holds, and the order writes that period beside the leaf, so the leaf that arrives matches the room that asked for it. What the report behind a period must hold is named in the fire door certification guide.
A leaf in the hall may need to hold fire as well as forced entry, and one doorset carries both proofs in a single report. EN 1634-1 gives the fire minutes and LPS 1175 Issue 8.2 of September 2024 gives the forced entry grade, in B3, C5 and D10, and the fire and security doors dual certification guide shows how the pair is proved on the same leaf.
FD60 on the counting room, back office and plant room
Behind the counting room leaf sit the takings and the prize float the hall runs on, so the leaf takes FD60 and stays shut whenever no one is counting cash. Sixty minutes is the hold the room asks for, because flame that reaches it takes the takings and the records the hall cannot replace.
The back office holds the keys, the session records and the paperwork, and its leaf takes FD60, because the keys and the papers behind it are what the hall opens with each evening. A leaf left standing open through the session holds nothing back, so the back office leaf is shut each time the last person leaves the room.
The plant room holds the boards and the equipment that keep the lights and the caller system running, and its leaf takes FD60 because the boards behind it feed the whole hall. The plant room fire doors guide takes the leaves of a plant room in full.
Entrance and cash desk: FD30 on the route the players use
Both the cash desk leaf and the entrance leaf take FD30, because the players stand at the cash desk and walk to the street through the entrance. Half an hour is more than the players need to leave, and the route behind the leaves is short, with the street at the end of it.
Where the route serves a crowd, the leaves on the way out carry a push bar proved to BS EN 1125, and the bar spans at least 60 percent of the leaf width, so a player reaching the leaf in a crowd opens it with one push. The panic hardware guide sets out what the bar must do when a crowd pushes against the leaf, and the emergency exit doors guide covers the leaves on the way out.
Staff see the players through a glazed panel in the cash desk leaf, so the leaf stays shut while the players are watched, and the pane is proved with the leaf round it, with the glass, the bead and the fixings named together in the report. What panels a fire leaf may carry is covered in the fire door vision panels guide, and the two leaf materials are set beside each other in the steel vs timber fire doors guide.
Smoke in the hall: Sa and S200 beside the period
People leaving the hall meet smoke before flame, so the leaves on the way out carry a smoke rating beside their fire period. The two ratings come from BS EN 1634-3, Sa for smoke at room temperature and S200 for smoke at 200 degrees, and how the route leaves keep the smoke back while the players move past them is worked through in the smoke control doors guide.
Where a leaf must stay open through a session, a hold-open device proved to BS EN 1155 holds it, and the device lets the leaf go on its own the moment the alarm sounds. The fire compartmentation guide names how the leaves hold the line between one part of the hall and the next, and a chair wedged under a leaf gives it no period at all while it stands open, so the wedge is never the device that holds a fire leaf.
Closers, seals and gaps on bingo hall doors: what the period rests on
The hour a FD60 leaf gives rests on the closer shutting it, the seals meeting the frame and the gaps staying narrow, because flame passes through a leaf left ajar in seconds and through a wide gap soon after. Closers are proved to BS EN 1154, and the power size runs from EN 1 for a leaf 750 mm wide and 20 kg in weight to EN 7 for a leaf 1,600 mm wide and 160 kg in weight, with EN 3 the minimum a fire door takes.
Once heat round the frame reaches 200 to 250 degrees the seal swells and closes the gap, so flame and hot gas cannot pass. The gaps round a hung leaf measure 4 mm, and a gauge on the monthly round shows whether a gap has grown past that figure. The intumescent seals guide covers fitting the seal, the fire door closers guide covers what the closer must do, and the fire door gaps guide covers measuring the gaps.
A fire leaf hangs on hinges proved to BS EN 1935, grade 13 for 200,000 cycles at 120 kg and grade 14 for 200,000 cycles at 160 kg, so the heavier leaf takes the heavier hinge. To BS 8300 and Approved Document M, the force to open a leaf on the public route stays below 30 N for the first 30 degrees and below 22.5 N beyond them, so a player can push the leaf open without help. What each sign on a fire door must say is named in the fire door signage guide.
Getting the players out: the way from the tables to the street
The alarm may sound while players who have never used the building sit at the tables, so the route to the street is signed at every turn. Nothing stands on the route, and the entrance leaf opens to one push from whoever reaches it first, whether the supply to the building is on or off.
Martyns Law puts a hall in a tier by how many people it holds, one tier for 200 to 799 people and a higher tier at 800 and above, with Royal Assent in April 2025 and the go-live expected in spring 2027. What each tier asks for is set out in the Martyns Law guide for premises, and a bingo hall holding 200 or more people falls in a tier that guide covers.
The bingo hall fire door order: every leaf, its period and its proof
The order gives every opening its own line, with the leaf, the period, the lock and the closer written beside it. One leaf named for the whole hall leaves the fitter to guess, and a leaf in the wrong room holds flame for the wrong length of time.
The order is read leaf by leaf before it is signed, because a closer that arrives after the doorset holds the job up, and a leaf with no line beside it cannot be checked when it arrives. What the order must hold for every door is set out in the how to specify security doors guide.
The hall manager takes the door list round the building once a month and tries the leaves in turn. A dragging leaf, a closer that leaves the leaf standing open or a seal that has been painted over is written against its own door on the day it is found, so the fault is put right before the leaf is asked to hold. For what to look for on each leaf, the fire door inspection checklist is the list to use, and the fire door maintenance guide covers the work that keeps the leaves holding.
The period on a bingo hall leaf follows the room behind it, so FD60 and FD30 must sit on the same list as the grade and the lock for each leaf.
What period should a bingo hall counting room door carry?
FD60 to EN 1634-1, because the counting room holds the takings and the prize float, and an hour is the hold that room demands.
What period should a bingo hall entrance door carry?
FD30 to EN 1634-1, because the entrance is the way out for the players and the public route needs half an hour.
Can one leaf hold fire and forced entry?
Yes, where the same leaf passed the fire test and the forced entry test, so the period and the grade are named together in one report.
Do bingo hall fire doors need a smoke rating?
Yes, the leaves on the route carry Sa or S200 to BS EN 1634-3 beside their period, because the players on the way out meet smoke before they meet flame.
What happens when a fire door will not shut?
A leaf that will not shut is written up against its own door the day the fault is found, and the hall does not wait for the next look round before the leaf is put right.