A casino holds cash, chips and records behind its leaves through day and night, so each door takes the fire period the room behind it demands.
- ✓Third-party test evidence with every product
- ✓Written specification you can issue to tender
- ✓Supplied and installed across the UK
Get a free project quote
Rating, written specification and budget range within one working day.
Confidential. No cost, no obligation.
Third-party tested
Evidence with every quote
UK manufactured
Made to your sizes
One accountable team
Specify, supply, install
Confidential handling
Details never shared
A casino is a gaming floor, a cash desk and a counting room behind one entrance, and the fire rules for the building follow the rooms behind each leaf. The cash desk holds the chips and the notes the crowd hands over, the counting room holds the takings counted after play, and the back office holds the keys and the records.
EN 1634-1 is the test that counts the fire minutes on a casino leaf. FD30 stands for thirty minutes and FD60 stands for sixty, and the letter beside the minutes says what the leaf held back, with E for flames alone, EW for flames with some heat held back and EI for flames with the heat held back as well.
A casino follows the same rules as any other venue that takes a crowd through one entrance at night. The fire door regulations cinemas guide covers the fire rules for a venue that holds a crowd in the dark, and the fire door regulations theatres guide covers the rooms a venue keeps behind its public floor.
- FD30 / FD60Fire periods to EN 1634-1
- Counting roomWhere the period rises
- Sa / S200Smoke ratings to BS EN 1634-3
- One listEvery casino door named
Five casino rooms and the period that protects each one
Five parts make up a casino, and the period follows what each part holds. The entrance holds the crowd coming in, the cash desk holds the chips and the notes the crowd hands over, the counting room holds the takings and the chips, the back office holds the keys and the records, and the plant room keeps the building running.
FD60 sits on the counting room, the back office and the plant room, because those rooms need sixty minutes before the fire reaches them. FD30 sits on the entrance and the cash desk, because the crowd on that route can move to the street in far less time than thirty minutes.
Each opening has its own line on the order, naming the leaf and the period beside it, so no leaf is hung on guesswork and no room ends up with a leaf that holds fire for the wrong length of time. The fire door regulations stadiums guide covers the fire rules for a venue that takes a crowd through wide entrances, and the fire door regulations commercial buildings guide covers the parts the buildings share.
| Position | Leaf | Period | What to check |
|---|---|---|---|
| Counting room | Steel leaf | FD60 | Leaf, lock, seals |
| Back office | Steel leaf | FD60 | Leaf, lock, seals |
| Plant room | Steel leaf | FD60 | Leaf, lock, seals |
| Cash desk | Glazed leaf | FD30 | Leaf, glass, closer |
| Entrance | Glazed leaf | FD30 | Leaf, glass, closer |
What FD30 and FD60 hold back on a gaming floor
A fire period counts minutes from the test, and the doorset that earns it is the leaf, the frame, the fixings and the lock proved as one. The report states the period the doorset holds, and the order writes that period beside the leaf, so the leaf that arrives is the leaf the room asked for. The fire door certification guide covers what the report behind the period must hold.
Some leaves in the casino must hold fire as well as forced entry, and one doorset carries both proofs in one report. EN 1634-1 gives the fire minutes, LPS 1175 Issue 8.2 of September 2024 gives the forced entry grade in B3, C5 and D10, and the fire and security doors dual certification guide shows how the pair is proved on the same leaf. The fire ratings standard page sets out how the letters and the minutes go together.
The counting room, the back office and the plant room: FD60 behind shut leaves
Behind the counting room leaf sit the takings and the chips the casino runs on, so the leaf takes FD60 and stays shut whenever no one is counting cash and chips. Sixty minutes is the hold the room asks for, because the takings and the records behind it cannot be replaced.
The back office holds the keys, the records and the paperwork, and its leaf takes FD60 for the same reason, because the keys and the system behind it are what the casino opens with each night. A leaf that stands open through the night holds nothing back, so the back office leaf is shut each time the last person leaves the room.
The plant room holds the boards and the equipment that keep the lights and the tables running, and its leaf takes FD60 because the boards behind it feed the whole casino. For plant rooms, the plant room fire doors guide takes the leaves in full, and the plant room door requirements guide takes the doors that guard the plant.
The entrance and the cash desk: FD30 on the route the crowd uses
The crowd stands at the cash desk and moves to the street through the entrance, so both leaves take FD30. Thirty minutes is more than the crowd needs to leave, and the route behind the leaves is short, with the street at the end of it.
Where the route serves a crowd, the leaves on the way out carry a bar proved to BS EN 1125, set across at least 60 percent of the leaf width, so a person who reaches the leaf in a crowd can open it with one push. The panic hardware guide covers what the bar must do for a crowd pushing against the leaf, and the emergency exit doors guide covers the leaves on the way out.
A glazed panel in the cash desk leaf lets the staff see the crowd without opening the leaf, and the pane is proved with the leaf round it, with the glass, the bead and the fixings named together in the report. The fire door vision panels guide covers the panels a fire leaf may carry, and the steel vs timber fire doors guide sets the two leaf materials beside each other.
Smoke on the gaming floor route: Sa and S200 beside the period
People on the way out meet smoke before they meet flame, so the leaves on the route carry a smoke rating beside their fire period. BS EN 1634-3 names the two ratings, Sa for smoke at room temperature and S200 for smoke at 200 degrees, and the smoke control doors guide works through how the route leaves keep the smoke back while the crowd moves past them.
A leaf that must stay open through a busy night takes a hold-open device proved to BS EN 1155, which shuts the leaf on its own the moment the alarm sounds. The fire compartmentation guide names how the leaves hold the line between one part of the casino and the next.
Closers, seals and gaps on casino doors: what the period rests on
A gauge measures the 4 mm gap round a hung leaf, so a hinge or a frame that has shifted shows up as a gap that has grown. Heat of 200 to 250 degrees swells the seal in the groove until it closes the gap, and paint over the seal stops it swelling, so the seal is checked as well as the gap.
At least EN 3 is the power size a fire door closer takes, the smallest the rules allow on a fire door, and the leaf must shut on its own from any angle it is opened to. BS EN 1154 runs the power sizes from EN 1 for a leaf 750 mm wide and 20 kg in weight to EN 7 for a leaf 1,600 mm wide and 160 kg in weight.
BS EN 1935 hinges carry the leaf through its working life, with grade 13 proved for 200,000 cycles at 120 kg and grade 14 proved for 200,000 cycles at 160 kg. The fire door hardware guide covers what the hardware on a fire leaf must do, and the fire door closers guide covers the closers in full.
Each fire door carries signs saying what the leaf is, and the fire door signage guide covers what each sign must say. The force to open a leaf on the public route stays below 30 N for the first 30 degrees and below 22.5 N beyond them, to BS 8300 and Approved Document M, so a person in the crowd can push the leaf open. The fire door gaps guide names how the gaps are measured, and the intumescent seals guide names how the seal is fitted.
Getting a crowd out: the way from the tables to the street
When the alarm sounds, the crowd must find the street without knowing the building, so the route is signed at every turn and nothing stands in it. Tables, chairs and displays are kept off the route, and the entrance leaf opens to one push from whoever reaches it first.
Martyns Law sorts premises into tiers by the number of people they hold, with one tier for 200 to 799 people and a higher tier at 800 and above, and the Martyns Law guide for premises sets out what each tier asks for. A casino that holds 200 or more people sits in a tier the guide covers, so the route out is planned with that tier in mind. The law received Royal Assent in April 2025, and the go-live is expected in spring 2027, so the route is planned now rather than when the date arrives.
The casino fire door order: every leaf, its period and its proof
Every opening in the casino gets a line on the order, with the leaf, the period, the lock and the closer written beside it. A single leaf named for the whole casino leaves the fitter to guess, and a leaf in the wrong room holds fire for the wrong length of time.
Each leaf on the order is checked before it is signed, because a closer ordered after the doorset arrives is a closer that holds the job up, and a leaf with no line beside it is a leaf no one can check when it arrives. The how to specify security doors guide covers what the order must hold for every door.
A leaf that will not shut, a closer that leaves the leaf standing open or a seal that has been painted over are the faults that show first, and each one is written against its own door on the day it is found, so the fault is put right before the leaf is asked to hold. The fire door inspection checklist covers what to look for on each leaf, and the fire door maintenance guide covers the work that keeps the leaves holding.
The period on a casino leaf means nothing on its own, so the leaf, the closer and the seal are ordered together and checked together against the room behind the leaf.
What period should a casino fire door carry?
FD60 for the counting room, the back office and the plant room, and FD30 for the entrance and the cash desk, each proved to EN 1634-1.
Can one leaf hold fire and forced entry?
Yes, where one doorset was proved for its fire minutes and its forced entry grade together, so the period and the grade sit in the same report.
Do casino fire doors need a smoke rating?
Yes, the leaves on the route take Sa or S200 to BS EN 1634-3 beside their period, because the people on the way out meet smoke before they meet flame.
Who checks the casino fire doors?
The casino manager keeps the door list and looks over the leaves in turn, so a leaf that will not shut or a seal that has been painted over is found before the leaf is asked to hold.
What happens when a fire door will not shut?
A leaf that will not shut is written up against its own door the day the fault is found, and the casino does not wait for the next look round before the leaf is put right.