A bookmaker is a betting shop where cash changes hands at a counter all day, and the doors in the building divide the public side from the rooms where the cash, the betting slips and the records sit. The entrance takes the queue in from the street, the counter stands between the queue and the staff, and the cash office, the back office and the plant room sit behind the counter where the public never goes.

The grades a bookmaker orders come from LPS 1175 Issue 8.2 of September 2024, which grades a leaf by the minutes it holds against the tools the test names. B3 is the three-minute grade, C5 the five-minute grade and D10 the ten-minute grade, and the leaf on each room takes the grade that matches what sits behind it. Older drawings call the same three grades SR2, SR3 and SR4, so the schedule lists both names beside each leaf and the fitter who works from an old drawing orders the right leaf.

A bookmaker is not a bank, and the doors are graded for a betting shop rather than a branch with vaults and safes. The bank security doors guide shows how a bank grades the doors round its cash, and the retail security doors guide shows how a shop grades the doors round its stock, while the leaves in a bookmaker follow the cash desk and the counter that sit between them.

  • B3 / C5 / D10Grades to LPS 1175 Issue 8.2
  • Cash officeWhere D10 sits in the shop
  • CounterWhere B3 sits in the shop
  • One listEvery bookmaker door named

Five rooms behind one betting shop front: the grade each room takes

Five rooms make up a bookmaker, and the grade follows what each room holds. The entrance takes the queue in, the counter holds the cash the queue hands over, the cash office holds the takings and the slips, the back office holds the keys and the screens, and the plant room keeps the building running through the working day.

The entrance leaf takes B3, and the counter leaf takes B3, because both leaves stand in view of the queue all day and must resist a quick attempt while the staff can see them. The back office and the plant room take C5, because the keys, the screens and the plant behind those leaves need a longer hold than the entrance. The cash office takes D10, because the takings behind it are the most valuable thing in the building and the leaf is shut and locked whenever no one is counting cash.

Every opening gets its own line on the order, with the leaf and the grade written beside it, so no leaf is hung on guesswork and no room ends up with a leaf that holds for the wrong number of minutes. The table below names the five rooms, the grade each one takes and the minutes behind the grade, so the fitter can check each leaf against its line as it is hung.

Room Grade Minutes What to check
Entrance B3 3 Leaf, lock, closer
Counter B3 3 Leaf, lock, seals
Cash office D10 10 Leaf, lock, hinges
Back office C5 5 Leaf, lock, seals
Plant room C5 5 Leaf, lock, seals

The shop entrance: a queue in, a shut leaf after closing

The entrance is the only leaf the public uses, and it opens and shuts for every person who comes in to place a bet, so its closer must bring it home after each person through without a slam that startles the queue. The leaf carries a glazed panel so the staff at the counter can see who is coming in, and the panel is tested as part of the doorset, with the glass, the bead and the fixings named together in the report.

Three minutes is the hold the entrance asks for, because the leaf stands where the counter staff can watch it through the whole working day, and a leaf that holds for three minutes gives the staff time to lock the counter leaf and call for help. The lock on the entrance leaf is a cylinder that takes a key from outside and a thumb turn from inside, so the staff can lock the shop at closing without searching for a key while the last customer is still at the counter.

At closing the entrance leaf is locked from inside by the thumb turn, so the last person out can secure the shop without a key in hand, and the cylinder on the outside takes a key for the first person in at opening. The leaves on the way out are covered in the emergency exit doors guide, and the panic hardware guide names what the bar on those leaves must do.

Need this specified for your project?Free rating, written specification and budget range within one working day.
Get a free quote

The counter: slips over, cash under, hands on the shop side

Cash passes over the counter all day, and the leaf behind the counter keeps the queue on the public side of it. B3 suits the counter leaf, because the leaf stands where the staff and the queue can both see it, and three minutes is the hold a leaf in full view asks for.

Staff pass through the counter leaf between the till, the printer and the cash office, and the leaf must let them through without letting the queue follow. A fob reader beside the leaf opens it for the staff cards named on the list, and the closer brings the leaf home after each person through. The security doors for supermarkets guide grades the doors of a shop that takes cash at tills all day, and the counter leaf in a bookmaker answers the same need on a smaller shop front.

Where a hatch or a screen sits in the counter so slips and cash can pass without the leaf opening, LPS 2081 names the grades for that opening. SRA holds for one minute and SRB holds for three minutes, and the hatch takes the grade the counter leaf beside it demands. The LPS 2081 standard page names both grades, EN 1627 names its own grades from RC1 to RC6, and the LPS 1175 vs EN 1627 guide sets the forced entry tests beside each other without naming one the equal of the other.

The cash office: takings and records behind D10

No other room in the shop holds as much cash as the cash office, so its leaf takes D10, the longest hold in the building. Ten minutes is the time the leaf must resist the tools named in the test, and the leaf, the frame, the fixings and the lock are proved together as one doorset, with the grade written in the report beside the leaf.

The cash office leaf carries no glass, so no one in the corridor can see when cash is being counted, and no panel gives a hand a way through the leaf to the lock. Hinges to BS EN 1935 carry the cash office leaf through its working life, with grade 13 proved for 200,000 cycles at 120 kg and grade 14 proved for 200,000 cycles at 160 kg, so the heavier leaf takes the heavier hinge and the bolt keeps meeting its keep.

Only the names on the list open the cash office, and the manager holds the key that opens it, so a leaf that stands open through the day is seen as a fault and shut at once. TS 007 puts a 1 star cylinder with a 2 star handle together to make a 3 star set, and the cylinder and the handle are ordered as a pair so the leaf is not fitted with a cylinder that the test never saw.

The back office and the plant room: keys, screens and the building plant

The back office holds the keys and the screens that run the betting system, so its leaf takes C5 and stays locked when the room stands empty. Keys left behind an open leaf are keys any passer by can lift, so the leaf is shut and locked each time the last person leaves the room.

The plant room holds the boards and the equipment that keep the lights, the screens and the heating running, and its leaf takes C5 because a leaf that gives way there lets a stranger reach the boards that run the whole shop. The plant room door requirements guide covers the leaves of a plant room in full, and the fire door regulations offices guide takes the same care with the back office of a shop.

Who carries which key: the shop team and the leaves they open

Staff cards open the leaves behind the counter, and the public side of the shop has no card that opens them. The security door locks guide names the lock each leaf must carry, and the master key systems guide shows how a key plan is drawn so a key opens the rooms its holder works in and no other room.

Glazed leaves and the view of the queue: seeing without opening

Light from the shop front and a view of the queue both matter in a betting shop, so the entrance and counter leaves carry glass that lets staff watch the queue while the leaf stays shut. The glass is proved with the leaf round it, and the report names the glass, the bead and the fixings together, so a pane is never ordered on its own.

One doorset, two proofs: fire minutes beside the forced entry grade

Some leaves in the shop must hold fire as well as forced entry, and the two proofs sit in one report for the same doorset. EN 1634-1 counts the fire minutes from 30 to 120, with E for flames alone, EW for flames with some heat held back and EI for flames with the heat held back as well, while LPS 1175 Issue 8.2 of September 2024 names the grade in B3, C5 and D10.

How the pair is proved on one leaf is shown in the fire and security doors dual certification guide, and what Issue 8.2 changed is set out in the LPS 1175 Issue 8 explained guide. The SR2 vs SR3 vs SR4 guide puts the old names beside the new grades, and the keeping an LPS 1175 rating valid guide names what can take a rating away once the leaf is hung.

A leaf that drags on the floor, a bolt that misses its keep or a seal painted over are the faults that show first, and each one is written against its own door on the day it is found, so the fault is put right before the leaf is asked to hold. The security door maintenance checklist names what to look for on each leaf, and the how to specify security doors guide lists what the order must hold for every door.

The grade on a bookmaker leaf means nothing on its own, so the leaf, the lock and the closer are ordered together and checked together against the room behind the leaf.

What grade should a bookmaker entrance door carry?

B3 to LPS 1175 Issue 8.2, which holds for three minutes, because the entrance stands in view of the counter and the queue all day.

What grade should a bookmaker cash office door carry?

D10 to LPS 1175 Issue 8.2, which holds for ten minutes, because the cash office holds the takings and the records behind a shut leaf.

Can one leaf hold fire and forced entry?

Yes, where one doorset was proved for fire minutes and for a forced entry grade together, so both proofs sit in one report.

What grade should a bookmaker counter door carry?

B3 to LPS 1175 Issue 8.2, which holds for three minutes, because the counter leaf stands where the staff and the queue can both see it.

Who checks the bookmaker doors?

The shop manager keeps the door list and looks over the leaves in turn, so a dragging leaf or a bolt that misses its keep is found before the leaf is asked to hold.

Specifying security doors for a bookmaker?Send the door list and the grade each room must hold for a tested door quotation.
Get a free quote

Related

More in guides for specifiers

10 mistakes when specifying certified security doors 10 steps to specify an LPS 1175 door Acceptance and Snagging of a Security Door or Barrier Job Access Control Doors Acoustic Doors: Ratings and Specification After a Forced Entry Attempt: Checking a Security Door Airport Security Doors Anti-Ligature Doors for Mental Health Wards Anti-Ram Bollards Anti-ram gates and barriers: protecting vehicle entrances Arcade Security Doors Explained Automatic Doors Automatic Gates Cost Factors Automatic Vehicle Barriers Ballistic Panels Bank Security Doors Bingo Hall Security Doors Explained Blast doors: glazed vs solid and how they are rated Blast protection window film: what it does and what it cannot do Blast resistant windows: what drives the cost and how to specify them Bollard Cost Factors Explained Bollard regulations in the UK: spacing, height and depth Builders Merchant Security Doors Bullet Resistant Glass Cost Factors Bullet resistant glass ratings explained: BR1 to BR7 and SG classes Bullet resistant vs bulletproof glass: what the difference means Buying Security Doors and HVM Through Public Frameworks Car Park Security Doors Explained Car Showroom Security Doors Casino Security Doors Explained CDM 2015 Duties When Security Doors, Shutters or HVM Are Installed Cinema Security Doors Cleanroom Doors Cold Store Doors College Security Doors Commissioning, Handover and the O&M Manual for Security Doors and HVM Communal entrance doors for flats: Secured by Design and what to specify Community Centre Security Doors Control Room Doors Court Security Doors Crash Rated Fences and HVM Fencing Explained Data centre physical security: doors, glazing, HVM and shielding by zone Dental Practice Security Doors Depot Security Doors Explained Door Entry Systems Due Diligence When Selecting Vehicle Security Barriers Emergency Exit Doors EMP Shielding Cost Factors Explained Exhibition Centre Fire Door Rules Exhibition Centre Security Doors Factory Security Doors Faraday cage vs RF shielded room: what a business needs FB4 vs FB6 vs FB7: how to choose a ballistic rating Fire and security doors: how dual certification works Fire Compartmentation Fire Curtains Fire Door Certification Fire Door Closers Explained Fire Door Cost Factors Fire Door Duties of the Accountable Person Fire Door Gaps Fire Door Hardware Explained Fire door inspection checklist for steel and timber doors Fire Door Maintenance Fire Door Regulations Care Homes Fire Door Regulations for A and E Departments Fire Door Regulations for Airports Explained Fire Door Regulations for Bowls Clubs Fire door regulations for commercial buildings in the UK Fire Door Regulations for Dialysis Centres Fire Door Regulations for Hockey Clubs Fire Door Regulations for Hospitals Explained Fire Door Regulations for Offices Explained Fire Door Regulations for Operating Theatres Fire Door Regulations for Retail Explained Fire Door Regulations for Schools Explained Fire Door Regulations for Snooker Clubs Fire Door Regulations for Stadiums Fire Door Regulations for Student Accommodation Fire Door Regulations for Warehouses Fire Door Regulations Leisure Centres Fire Door Regulations Restaurants Fire Door Remediation Programme for Housing Providers Fire Door Rules for Badminton Clubs Fire Door Rules for Bingo Halls Fire Door Rules for Bookmakers Fire Door Rules for Bowling Alleys Fire Door Rules for Car Parks Fire Door Rules for Car Showrooms Fire Door Rules for Cinemas Fire Door Rules for Climbing Centres Fire Door Rules for Colleges Fire Door Rules for Community Centres Fire Door Rules for Cricket Clubs Fire Door Rules for Dental Practices Fire Door Rules for Depots Explained Fire Door Rules for Golf Clubs Fire Door Rules for GP Surgeries Fire Door Rules for Gyms Explained Fire Door Rules for Ice Rinks Fire Door Rules for Maternity Units Fire Door Rules for Mental Health Units Fire Door Rules for Museums Fire Door Rules for Oncology Units Fire Door Rules for Opticians Fire Door Rules for Pawnbrokers Fire Door Rules for Petrol Stations Fire Door Rules for Pharmacies Fire Door Rules for Ports Fire Door Rules for Post Offices Fire Door Rules for Prisons Fire Door Rules for Rehabilitation Centres Fire Door Rules for Self Storage Fire Door Rules for Shopping Centres Fire Door Rules for Squash Clubs Fire Door Rules for Supermarkets Fire Door Rules for Swimming Pools Fire Door Rules for Tennis Clubs Fire Door Rules for Theatres Fire Door Rules for UK Arcades Fire Door Rules for UK Casinos Fire Door Rules for UK Hospices Fire Door Rules for Walk-in Centres Fire Door Signage Fire Door Vision Panels Fire Doors and Gateway 2 in Higher-Risk Buildings Fire Rated Glass Cost Explained Fire Rated Sliding Doors Explained Fire Rated Windows Cost Factors Fire Rated Windows Explained Fire Safety Enforcement Notices and Fire Doors: What the Responsible Person Must Do Flat Entrance Doors: PAS 24 and Fire Rated Forced Entry vs Ballistic vs Blast: Which Rating a Site Needs Garage Security Doors Explained Gate Automation Explained Golden Thread Records for Fire Doors GP Surgery Security Doors Explained Gym Security Doors Explained High Speed Doors HMO Fire Doors Hospice Security Doors Explained Hospital Security Doors: Wards, A&E, Plant Hospital Security Gates Hotel Fire Doors Hotel Security Doors How to choose HVM bollards: fixed, shallow mount, removable and automatic How to keep an LPS 1175 door rating valid after installation How to Specify Fire Doors in a Housing Tender How to specify security doors: a checklist for architects How to Verify a Secured by Design Listing How to Verify an LPS 1175 Certificate on Red Book Live How to Write an Operational Requirement for Physical Security HVM planters and street furniture: protection that blends in In-Service Care of Vehicle Security Barriers Installation Handover: LPS 1175 Doors and PAS 68 Barriers Intumescent Seals ISO 16933 explained: EXV and SB classes and hazard ratings ISO 22343 vehicle security barriers explained Keeping a Dual-Certified Fire and Security Door Valid in Service Laboratory Security Doors Layered Security for a Site: Deter, Detect, Delay, Mitigate, Respond Lead Times and Programme Risks for LPS 1175 Doors Leisure Centre Security Doors Library Security Doors Listed Building Fire Doors Loading Bay Doors Explained Lockdown and Access Control Hardware on an LPS 1175 Door LPS 1175 Gates and Grilles Explained LPS 1175 Issue 8 explained: from SR1 to SR8 to A1 to H20 LPS 1175 Roller Shutters LPS 1175 vs ASTM F2781 and Other US Ratings Explained LPS 1175 vs EN 1627: how UK and European burglar resistance ratings compare LPS 1175 vs PAS 24: which security standard does your door need? LPS 1175 Windows and Walling Explained Martyn’s Law and Places of Worship: What a Buyer Checks for Doors and Entry Control Martyn’s Law Enhanced Tier: Physical Measures and the Specifier Brief Martyn’s Law Standard Tier: Procedures, Doors and Shutters Martyn’s Law Timeline and the SIA Regulator Martyn’s Law: what premises must do and which physical measures to consider Master Key Systems MRI and RF shielded rooms: how they work and what to specify Museum Security Doors NPSA Catalogue of Security Equipment (CSE) Explained NPSA Forced Entry and Blast Guidance for Government Sites NPSA Guidance on Lockdown and Marauding Attack: What It Asks of Doors and Entrances Office Security Doors Optician Security Doors Explained Panic Hardware PAS 24 requirements for doors and windows explained PAS 68 Bollard Foundations Explained PAS 68 bollards: ratings, spacing and cost factors PAS 68 vs IWA 14 vs ISO 22343: hostile vehicle mitigation standards explained Pawnbroker Security Doors Explained Pedestrian Gates Petrol Station Security Doors Pharmacy Security Doors Planning Permission for Security Shutters, Gates and Bollards on Commercial Premises Plant room doors: fire, security and ventilation requirements Plant Room Fire Doors Port Security Doors Post Office Security Doors Explained Powder coating vs galvanising vs paint for steel Preliminary Market Engagement for Security Doors and HVM Prison Security Doors Programming a Security Door and Barrier Package on a Live Site Public-Sector Tender Response Checklist for Security Door and HVM Supply Reading a PAS 24 and SBD Door Test Report Regulation 38 Fire Safety Information at Handover for Fire-Rated Security Doorsets Replacing Security Doors in an Occupied Building Restaurant Security Doors Retail Security Doors Revolving Doors RF shielding standards and how shielded rooms are tested Rising Bollard Cost Factors Road Blocker Cost Factors Explained Road Blockers Explained Roller Shutter Cost Factors: What Drives the Price Roller shutter regulations in the UK: safety and maintenance Safe room and panic room doors: specification basics Safety Duties for Powered Doors, Gates and Barriers on Commercial Sites School Security Doors Sectional Doors Secured by Design explained: is it mandatory for doors? Secured by Design vs NPSA vs LPCB: Which One You Need Security Door Locks Security Door Maintenance Checklist Security Doors and Access for Everyone: What Approved Document M Asks Security Doors for A and E Departments Security Doors for Badminton Clubs Security Doors for Bowling Alleys Security Doors for Bowls Clubs Security Doors for Climbing Centres Security Doors for Cricket Clubs Security Doors for Dialysis Centres Security Doors for Golf Clubs Security Doors for Hockey Clubs Security Doors for Ice Rinks Security Doors for Maternity Units Security Doors for Mental Health Units Security Doors for Oncology Units Security Doors for Operating Theatres Security Doors for Rehabilitation Centres Security Doors for Snooker Clubs Security Doors for Squash Clubs Security Doors for Swimming Pools Security Doors for Tennis Clubs Security Doors for Walk-in Centres Security Doors West Midlands Explained Security Fencing Security Gates Cost Factors Explained Security shutters vs high performance roller doors Security shutters vs retractable grilles: which suits retail and commercial openings? Security Turnstiles Explained Security Window Film Security Windows for Schools Explained Self Storage Security Doors Server Room Doors Explained Shopping Centre Security Doors Smoke Control Doors Explained Smoke Curtains Specification Mistakes When Mixing LPS 1175, PAS 24 and SBD in One Tender SR2 vs SR3 vs SR4 security doors: choosing the right LPS 1175 level Stadium Security Doors Steel Door Frames Steel vs aluminium security doors: strength, ratings and looks Steel vs timber fire doors: which suits your building? Student Accommodation Security Doors Substation doors: security, ventilation and specification Supermarket Security Doors Telescopic Bollards Tender Evaluation Criteria and Scoring for Security Doors and HVM The Scope of a Maintenance Contract for Security Doors and Barriers Theatre Security Doors Thermal and Weather Performance of External Security Doorsets Thermally broken steel security doors: U-values and certification Traffic Calming as Hostile Vehicle Mitigation Transport hub security requirements Turnstile Cost Factors Explained Turnstile vs speed gate vs security portal: choosing entrance control Types of security doors for commercial buildings University Security Doors Explained Vehicle Dynamics Assessment: What It Tells the Buyer Before a Barrier Is Specified Warehouse Security Doors Explained Warehouse Security Gates Warranty, Defects Liability and Guarantees for Security Doors and Barriers What affects the cost of a bullet resistant door What affects the cost of a high-security door in the UK Window Security Bars View all →

Products

One supplier for the whole building envelope

Ready to specify your project?

Free assessment, written specification and test evidence. Reply within one working day.