Fire Door Rules for Post Offices
A post office needs FD60 on the rooms that hold cash and parcels and FD30 on the public route, so each leaf takes the period its room demands.
- ✓Third-party test evidence with every product
- ✓Written specification you can issue to tender
- ✓Supplied and installed across the UK
Get a free project quote
Rating, written specification and budget range within one working day.
Confidential. No cost, no obligation.
Third-party tested
Evidence with every quote
UK manufactured
Made to your sizes
One accountable team
Specify, supply, install
Confidential handling
Details never shared
A post office door takes its fire period from the room behind it. The cash office, the parcels store, the back office and the plant room take FD60, and the counter and the entrance take FD30, because the rooms behind the counter hold cash, parcels and records that need a longer hold than the public route. The period sits beside the leaf on the order, and the leaf, the frame and the seals are proved together for that period.
The proof comes from EN 1634-1, which names the period in minutes from 30 to 120 and the letters E, EW and EI that say what the leaf held back. FD30 holds for 30 minutes and FD60 holds for 60 minutes, and the letters beside the number say whether the leaf held flame alone or flame and heat together. A leaf ordered as FD60 without its letters leaves the branch unsure what the leaf was proved to hold. The fire ratings standard page names how the letters and the minutes sit together.
A post office leaf may also need to hold forced entry, and the grade beside the period comes from LPS 1175 Issue 8.2 of September 2024. The entrance and the counter take B3, the parcels store, the back office and the plant room take C5, and the cash office takes D10, and the minutes behind those grades are three, five and ten. The bank security doors guide takes the same pairing of period and grade for a branch that holds cash behind a counter, and the fire and security doors dual certification guide shows how the two proofs are taken on one doorset. The LPS 1175 Issue 8 explained guide sets out what Issue 8.2 changed.
- FD60 / FD30Periods to EN 1634-1
- Cash officeWhere FD60 sits
- 4 mmGap round a hung leaf
- One listEvery leaf on one line
Six rooms behind the counter: which period each one takes
Six rooms make up a post office, and the period follows what each room holds. The entrance meets the queue from the street, the counter holds the cash the queue hands over, the cash office holds the takings, the parcels store holds the parcels the branch moves, the back office holds the records and the keys, and the plant room keeps the lights and the heat running through the working day.
The cash office, the parcels store, the back office and the plant room take FD60, because the takings, the parcels, the records and the machinery behind those leaves need an hour before flame passes the leaf. The counter and the entrance take FD30, because the public route must hold long enough for the queue to reach the street and no longer than the rooms behind the counter demand.
The table below names the six rooms, the period each one takes and the grade that sits beside the period, so the fitter can check each leaf against its line as it is hung and the branch can see at a glance which leaf holds for an hour and which holds for half an hour.
| Room | Period | Grade | What to check |
|---|---|---|---|
| Entrance | FD30 | B3 | Leaf, closer, vision panel |
| Counter | FD30 | B3 | Leaf, lock, seals |
| Cash office | FD60 | D10 | Leaf, lock, reader |
| Parcels store | FD60 | C5 | Leaf, lock, seals |
| Back office | FD60 | C5 | Leaf, lock, reader |
| Plant room | FD60 | C5 | Leaf, lock, seals |
The cash office holds FD60 behind a shut steel leaf
The cash office holds the takings of the branch, and its leaf takes FD60 because an hour is the hold the takings demand when flame reaches the corridor outside. The leaf is steel, and it stands shut through the working day, opening only for the staff the list names and shutting on its own behind each person through it.
The leaf, the frame and the seals are proved together as one doorset for FD60, and the report names the period and the letters beside it, so the branch knows the leaf was proved as a whole rather than as parts that were never tested together. The fire door certification guide names what the report must hold before the leaf is accepted on site, and the steel vs timber fire doors guide names why a steel leaf suits a room that holds cash. The keeping an LPS 1175 rating valid guide names what can undo a rating after a door is hung.
Parcels, back office and plant room: why FD60 sits on the stores
The parcels store holds the parcels the branch moves each day, and a stack of parcels feeds flame fast once it catches, so its leaf takes FD60 and stands shut between deliveries. The back office holds the records and the keys, and the plant room holds the boilers and the boards that run the branch, so both leaves take FD60 for the same reason as the parcels store.
The three leaves sit behind the same corridor as the cash office, and the order names FD60 beside each one so the fitter does not hang a FD30 leaf where the corridor asks for an hour. The fire door regulations warehouses guide takes the same care with the stores of a warehouse, the fire door regulations retail guide takes it with the stock rooms behind a shop, the fire door regulations supermarkets guide takes it with the stores behind a supermarket, the fire door regulations offices guide takes it with the back office of an office, and the plant room fire doors guide takes it with the leaf on a plant room.
The counter and the public route take FD30
The counter leaf stands between the staff and the queue, and it takes FD30 because the public route must hold flame for half an hour while the queue reaches the street. The leaf stays shut while the counter serves, and it opens only for the staff who work behind it, so the period is proved on a leaf that is shut when flame reaches it.
The entrance leaf takes FD30 for the same reason, because the entrance is the way out for the queue and the leaf must hold while the last person through it reaches the street. A glazed panel in the entrance leaf lets the staff see who waits outside, and the pane is proved with the leaf round it, with the beads and the fixings named in the same report. The fire door vision panels guide names what a glazed leaf must hold, and the fire door regulations shopping centres guide takes the same care with the public route through a centre.
Closers, seals and gaps: the hardware that keeps FD60 honest
A FD60 leaf holds for an hour only when its closer shuts it, its seals meet the frame and its gaps stay narrow, because flame passes through a leaf left ajar in seconds and through a wide gap soon after. The closer on each leaf is proved to BS EN 1154, and the power size runs from EN 1 for a leaf 750 mm wide and 20 kg in weight to EN 7 for a leaf 1,600 mm wide and 160 kg in weight, with EN 3 as the minimum on a fire door.
The intumescent seal in the frame swells when the heat round it reaches 200 to 250 degrees, and the swollen seal closes the gap between the leaf and the frame so flame and hot gas cannot pass. The gaps round the leaf are 4 mm once the leaf is hung, and a gauge on the monthly round shows whether a gap has widened past that figure. The intumescent seals guide names how the seal is fitted, the fire door closers guide names what the closer must do, and the fire door gaps guide names how the gaps are measured.
Getting the queue out: the route from the counter to the street
The queue at the counter has never used the building before, so the route from the counter to the street is signed at every turn and kept clear of parcels, trolleys and displays. A leaf on the route opens to one push from whoever reaches it first, and it opens whether the supply to the building is on or off, because the moment the alarm sounds is the moment the route must work.
Where the route serves a crowd, the leaves on the way out take a bar proved to BS EN 1125, set across at least 60 percent of the leaf width, and the bar is the answer where more than 60 people use the route. The emergency exit doors guide names what the way out must do, the panic hardware guide names how the bar is fitted and proved, and the fire door signage guide names what the signs on the route must say.
Smoke on the public route: Sa and S200 beside the period
People on the escape route meet smoke before they meet flame, so the leaves on the public route carry a smoke rating beside their period. The two smoke ratings come from BS EN 1634-3, with Sa for smoke at room temperature and S200 for smoke at 200 degrees, and the seal that earns either rating must meet the frame all round without a break.
A leaf that must stay open through a delivery takes a hold-open device proved to BS EN 1155, which shuts the leaf on its own the moment the alarm sounds. The smoke control doors guide works through how the doors keep smoke back, and the fire compartmentation guide names how the leaves hold the line between one part of the branch and the next.
The post office fire door order: every leaf, its period and its proof
One list carries the whole post office order, with a line for every opening that names the leaf, the period, the grade and the lock beside it. A list that names one leaf for the whole branch leaves the fitter to guess which room takes FD60 and which takes FD30, and a leaf in the wrong room holds for the wrong number of minutes while the branch believes it is covered.
The branch manager walks the post office with the door list each month, trying a few leaves on each walk so every leaf is tried before the month ends. The entrance is tried at opening, the counter before the first customer, and the cash office at closing, and each fault found is written against its own leaf on the day it is found, with the date and the leaf beside it, so a closer that is losing its pull is seen before the leaf stops shutting.
The fire door inspection checklist names what the walk should cover, the fire door maintenance guide names what the walk should find, and the how to specify security doors guide names what the order must hold for every leaf.
The period on a post office leaf follows the room behind it, so FD60 and FD30 must sit on the same list as the grade and the lock for each leaf.
What period should a post office cash office door carry?
FD60 to EN 1634-1, because the cash office holds the takings and an hour is the hold the room behind the leaf demands.
What period should a post office entrance door carry?
FD30 to EN 1634-1, because the entrance is the way out for the queue and half an hour is the hold the public route needs.
Can one post office leaf hold fire and forced entry?
Yes, where a single doorset passed the fire test and the forced entry test together, so the period and the grade sit in one report.
What gap should a post office fire door carry?
4 mm round the leaf once it is hung, and a gauge on the monthly round shows whether the gap has widened past that figure.
Who tries the post office fire doors each month?
The branch manager, who walks the branch with the door list and tries a few leaves on each walk until every leaf has been tried.