ArxBridge
Exhibition Centre Security Doors
An exhibition centre fills with crowds between shows, so each leaf takes the grade the room behind it demands, from entrance hall to cash room.
- ✓Third-party test evidence with every product
- ✓Written specification you can issue to tender
- ✓Supplied and installed across the UK
Get a free project quote
Rating, written specification and budget range within one working day.
Confidential. No cost, no obligation.
Third-party tested
Evidence with every quote
UK manufactured
Made to your sizes
One accountable team
Specify, supply, install
Confidential handling
Details never shared
An exhibition centre is a set of halls joined by corridors and loading bays, and the doors between those parts decide what stays where it belongs. The halls hold the crowds and the stands, the stores hold the exhibits and the kit, and the offices behind them hold the bookings, the takings and the plant, so each door takes its proof from the room behind it.
Under Issue 8.2 of September 2024 the three LPS 1175 categories are B3, C5 and D10, proved at three, five and ten minutes. The entrance takes the lowest of the three, the halls take the middle one, and the cash room takes the highest.
An exhibition centre follows the same rules as any other commercial building, and the fire door regulations commercial buildings guide covers the shared parts, while the stadium security doors guide covers the stands of a stadium rather than the halls of a centre. The centre order names every door, with the grade and the lock beside each one, so the door that arrives is the door its room asked for.
- LPS 1175 B3 / C5 / D10Forced entry grades to Issue 8.2
- HallsWhere the grade rises
- FD30 / FD60Fire periods to EN 1634-1
- One listEvery centre door named
Halls, stores and offices: one exhibition centre, three grades
Three parts make up an exhibition centre, and the grade follows what each part holds. The halls hold the crowds and the stands, the stores hold the exhibits, and the cash room holds the money the show has taken, so each part takes the doors its work demands.
The entrance leaf opens for every visitor who arrives and shuts behind them on its own, because a leaf left standing open guards nothing. The hall leaf stands shut through the show, and it must hold against the attack the exhibits behind it invite.
The order is written from a list that names every opening, the leaf it takes and the grade beside it, because a leaf with no line on the list may turn up in the wrong hall.
The entrance and the ticket hall: the leaves every visitor passes
An entrance leaf has two jobs at once: to open for every visitor who arrives, and to hold an intruder out once the centre shuts. The leaf, the frame and the lock are proved as one doorset, and the test report names all three.
A closer pulls the entrance leaf shut after every visitor who passes, because a leaf left standing open guards nothing. The closer is set so the leaf comes home without a slam, and the pull is checked by opening the leaf and watching it shut on its own.
A glazed panel in the entrance leaf lets the ticket hall see who waits outside before the leaf opens, and the glass takes the same proof as the leaf round it. The fire rated glass cost guide works through what the pane adds to the order, and the test report names the bead and the fixings that hold it.
The halls: crowds, stands and the doors between them
Behind every hall door sit the stands the centre runs on, and the leaf that guards them takes the grade the value behind it demands. C5 suits the halls, because the exhibits behind them justify the minutes it takes to break through, and the leaf must hold until the alarm is answered.
Only the centre team holds the key to the halls, because visitors must never pass them alone. The hall leaf takes C5, the cash room beside it takes D10, and the entrance takes B3.
A hall leaf can carry both proofs at once, because the hall needs fire held back and an intruder held out. Both proofs sit on one doorset where the same leaf, frame and seals faced the two tests together, so one report covers the pair, and the fire and security doors dual certification guide shows how the pair is held.
The hall leaf shuts out the sound of the crowds as well as an intruder, so the offices stay quiet while visitors move through. Seals round its edges and a closer that brings it home after every member of staff who passes do that work.
Stores, loading bay and plant room: the doors behind the halls
The stores hold the exhibits and the kit that the shows run on, and the leaf that guards them takes the grade the value behind it demands. C5 suits the stores, because the exhibits behind them justify the minutes it takes to break through.
Deliveries reach the centre through the loading bay, so its leaf must be wide enough for crates and forklifts, with a closer that pulls it shut after each load. The loading bay leaf takes C5, because the stock passing through it is worth the minutes it takes to break through, and the leaf, the frame, the fixings and the lock are proved together as one doorset, with the report naming the grade the leaf holds. The loading bay doors guide covers the doors that take the deliveries in, and the plant room door requirements guide sets out what the plant room leaf must do.
The plant room holds the services that keep the centre running, and its leaf takes the grade the value behind it demands. C5 suits the plant room, because the boards and the plant behind it justify the minutes it takes to break through.
Each leaf hangs with a 4 mm gap round it, so it swings without catching and the seal meets the frame when the leaf shuts. As the heat passes 200 degrees the seal swells and closes the gap, unless a coat of paint over the seal stops it swelling.
The cash room and the back office: where the takings and the bookings sit
The cash room takes the highest grade in the centre, because the takings sit behind its leaf. The leaf, the frame, the fixings and the lock are proved together as one doorset, and the report names each part, so the door that arrives is the door that was proved.
D10 suits the cash room, because it must hold longest, while the halls beside it take C5 and the entrance takes B3. Drawings drawn before Issue 8 call the same three categories SR2, SR3 and SR4, so the order carries the new name beside the old one.
The back office next to the cash room holds the bookings and the keys, so its leaf takes the same care. C5 suits the back office leaf, and the lock on it takes the same key as the cash room, so one key opens both doors for the staff who work there. The faults that break a rating once a door is fitted are named in the keeping an LPS 1175 rating valid guide.
The way out of a full hall: escape routes visitors can follow
When the alarm sounds in a hall, the visitors head for the exit the signs name, and the way must be clear of stands, cases and anything left against the doors. Each leaf on that way gives way under one push, whether the power is on or off, so no visitor waits for a key.
A route door needs a smoke rating as well as a fire period, and the rating comes from BS EN 1634-3. Sa covers smoke at room temperature, and S200 covers smoke at 200 degrees, and either mark holds only where the seal meets the frame all round. The smoke control doors guide works through how the doors hold smoke back while visitors move past them.
Every leaf on the route carries the period the route needs, because the route holds only as long as its weakest leaf. A leaf that gives way first takes the route with it, so no leaf on the route takes a shorter proof than the rest. The same care with crowds is taken in the fire door regulations stadiums guide.
| Position | Door | Grade | What to check |
|---|---|---|---|
| Entrance | Glazed leaf | LPS 1175 B3 | Leaf, glass, closer |
| Halls | Steel leaf | LPS 1175 C5 | Leaf, lock, seals |
| Stores | Steel leaf | LPS 1175 C5 | Leaf, lock, seals |
| Back office | Steel leaf | LPS 1175 C5 | Leaf, lock, reader |
| Cash room | Steel leaf | LPS 1175 D10 | Leaf, lock, reader |
| Plant room | Steel leaf | LPS 1175 C5 | Leaf, lock, seals |
| Loading bay | Steel leaf | LPS 1175 C5 | Leaf, closer, lock |
Locks, passes and the centre team: who opens which door
The centre team moves from the ticket hall through the halls to the plant room and back, and every leaf on that route opens for staff and stays shut for visitors after hours. Beside each leaf on the route sits a reader, and it opens for the passes the list names. What the lock the key turns must do is set out in the fire door hardware guide, and the security door locks guide names what the lock on a hall leaf must hold.
What sits beside a leaf, readers, releases and wiring, is named in the door entry systems guide.
Beside each door on the order sits the answer for the night the power fails, so every leaf knows whether it opens or stays shut when the supply goes. A door with no answer beside it leaves the centre team guessing on the night the answer matters most.
The exhibition order: every leaf on one list
The whole exhibition order sits on one list, a line for every door with the leaf, the grade, the lock and the closer beside it, so the door that arrives is the door its room asked for. A list that names a single leaf for the whole centre leaves the fitter to guess which room takes which grade, and a leaf in the wrong hall guards the wrong thing.
Each leaf on the order carries its own figure, and the figures are laid beside the schedule and checked one door at a time before the order goes out, because a door left off the quotation is a door the centre still pays for, and a lock added once the order has gone costs more than the same lock added with it. What the schedule must hold for every door is listed in the how to specify security doors guide, and what each step up the grade adds to the figure is set out in the security door cost factors guide.
Between shows the centre team walks the halls and tries the leaves in turn, a few each day, so no door goes untried for long. A fault found on the round is written against its door the same day, with the part and the date beside it, and the repair is booked before the next show opens. The fire door inspection checklist names what the visit should cover, and the doors that must hold both fire and forced entry are covered in the security door maintenance checklist.
An exhibition centre door holds only as long as the halls behind it and the crowds beside it, so the grade, the period and the lock must all sit on the same list.
What grade should an exhibition centre door carry?
B3, C5 or D10 to LPS 1175. The halls take the middle category, the entrance takes the lowest, and the cash room takes the highest, so the grade follows the room behind the leaf.
Can one leaf hold fire and forced entry?
Yes. A leaf that faced the fire test and the forced entry test together holds one report for the pair, because the leaf, the frame and the seals were proved as one doorset.
Do exhibition centre doors need access control?
The doors behind the entrance take a reader beside the leaf, so the leaf opens for the centre team and stays shut for visitors after hours.
What period should an exhibition centre door carry?
A hall leaf takes FD30 or FD60, proved to EN 1634-1, and the period follows the room behind the leaf, with the letters beside the minutes naming what the leaf held back.
Who checks the exhibition centre doors?
Between shows the centre team tries every door on the round, and each visit is written into the record the centre keeps.
Get a free quote
Related
More in guides for specifiers
Products
One supplier for the whole building envelope
Ready to specify your project?
Free assessment, written specification and test evidence. Reply within one working day.