A port is a quay, a terminal and a yard under one fence line, and the doors between those parts decide what stays where it belongs. The quay holds the ships and the cargo, the terminal holds the passengers and the paperwork, and the yards behind them hold the stores, the workshops and the fuel, so each door takes its proof from the room behind it.
LPS 1175 sets the grade on a port door, and the category follows what sits behind the leaf. B3 holds for three minutes, C5 for five and D10 for ten, all to Issue 8.2, dated September 2024. The terminal front takes the lowest of the three, the stores take the middle one, and the control room takes the highest.
A port follows the same rules as any other transport hub, and the transport hub security requirements guide covers the shared parts, while the warehouse security doors guide covers the stores beside the quay. Every door on the port goes on one order, with its grade and its lock beside it, so what arrives matches what each room asked for.
- LPS 1175 B3 / C5 / D10Forced entry grades to Issue 8.2
- PAS 68 / ISO 22343Vehicle impact ratings on the quay
- FD30 / FD60Fire periods to EN 1634-1
- One listEvery port door named
The quay, the terminal and the control room: one port, three grades
A port splits into three parts, and the grade follows what each part holds. The terminal serves the passengers, the stores feed the ships, and the control room holds the systems that run the quay, so each part takes the doors its work demands.
The terminal takes the doors the public walks through all day, and each leaf must open for a passenger with luggage in hand and shut behind them on its own. The stores take the doors the public never sees, and each leaf must hold against the attack the cargo behind it invites, because the goods are worth the effort of breaking in.
The schedule comes first: every opening on the port, the leaf it takes and the grade beside it.
The terminal front: the leaves the public meets
The terminal front is glass from the counter to the roof, and the doors in it are glazed leaves that let the staff see the quay while they serve. A glazed leaf takes the same proof as the leaf beside it, because a pane that fails lets the leaf fail with it.
The bead and the fixings that hold the pane are named in the test report, and the frame beside the leaf carries the same proof as the leaf itself. What the glass itself costs is worked through in the fire rated glass cost guide, and the panes that carry a ballistic rating are set out in the ballistic glass ratings guide.
The terminal leaf takes a closer that brings it home after every passenger who passes, because a leaf left open lets the weather in. The closer is set so the leaf comes back to the frame without a slam, and the pull is checked by opening the leaf and letting it go.
Stores and workshops: where the cargo waits
Behind the terminal, the stores hold the goods the ships will need next, and the leaf takes the grade the value behind it demands. C5 suits the stores, because the cargo behind it justifies the minutes it takes to break through, and the leaf must hold until the alarm is answered.
The workshop beside the stores takes the same care, because the tools and the spares sit behind its doors. Its leaf takes a lock the supervisor controls, and the doorset is proved as one piece, leaf, frame and lock together, with the report naming each part.
The fuel store takes the goods in from the yard, and it takes a leaf wide enough for drums and a closer that pulls it shut after each load. Its leaf, frame, fixings and lock are proved as one doorset.
The control room: the highest grade on the quay
No room on the port takes a higher grade than the control room, because the systems, the keys and the records sit behind its leaf. The control room leaf takes D10, because it must hold longest, while the stores beside it take C5 and the terminal front takes B3.
Older drawings call the same three categories SR2, SR3 and SR4, and the order carries the new name beside the old one so the fitter is not left guessing. No published table converts an LPS 1175 category into a category from another standard, so the order names the LPS 1175 category and nothing else.
The duty manager holds the key to the control room, and its leaf is proved with its frame and its lock as one doorset. What breaks a rating once a door is fitted is named in the keeping an LPS 1175 rating valid guide.
Gates, fences and the vehicle line: the perimeter that feeds the doors
The doors on a port are only as strong as the line that leads to them, because a vehicle that reaches the quay unchecked can strike a leaf that was never meant to stop it. The vehicle line is rated to PAS 68 or ISO 22343-1, and the rating names the vehicle, the speed and the distance the barrier held it back.
ISO 22343-1 supersedes PAS 68, and its rating reads as a line of figures: V/7500[N3]/80/90:0/0 names a 7,500 kg vehicle at 80 km/h, stopped 90 cm past the line. Test vehicles run from a 1,500 kg car to a 30,000 kg truck, at speeds of 48, 64 and 80 km/h. The HVM standards guide works through PAS 68, IWA 14 and ISO 22343 side by side.
The gap between the barriers matters as much as the barriers themselves, because a gap wider than 1,200 mm lets a vehicle through, and the barriers must stand at least 500 mm high to meet it. The PAS 68 bollards guide covers the bollards that guard the quay, the crash rated fences guide covers the fences that run between them, and the bollard regulations guide covers the rules that decide where each one stands. Gates that carry a rating are covered in the anti-ram gates and barriers guide, and what the gates themselves cost is worked through in the security gates cost factors guide.
One leaf, two tests: the fire proof beside the forced entry proof
A port leaf can be proved for both jobs on one doorset, because the terminal needs fire held back and the control room needs an intruder held out. The fire proof is proved to EN 1634-1, in E, EW and EI with minutes from 30 to 120, and the forced entry proof to LPS 1175, in B3, C5 and D10, with the leaf, the frame and the seals facing both tests together so both proofs sit on one report. The fire and security doors dual certification guide works through how one doorset carries both proofs.
Each room on the port asks a different period of its doors, because the terminal, the stores and the control room put different loads behind each leaf, while the grade follows the value behind it. Minutes run from 30 to 120 beside letters that name what stayed back: flames on their own, flames with some heat, or flames with the heat as well. Doors on the route carry a smoke rating beside the fire period, proved to BS EN 1634-3, with Sa for smoke at room temperature and S200 for smoke at 200 degrees. How smoke is held back while people move past is covered in the smoke control doors guide.
A 4 mm gap is left beside the leaf so it can swing without catching, and the seal meets the frame all round once the leaf is shut. Once the heat reaches 200 to 250 degrees the intumescent seal swells and shuts the gap.
Locks, readers and the gatehouse: who opens which door
Staff move from the terminal through the stores to the control room and back, and every leaf on that route opens for staff and stays shut for the public. Each leaf on the route takes a reader beside it, and the passes the list names open the doors the list allows. What the lock the key turns must do is named in the fire door hardware guide.
The gatehouse sits at the entrance to the yard, and only the staff who run the port hold its key. The vehicle logs, the permits and the delivery records sit behind that leaf, so it takes the same grade as the stores beside it. Readers, releases and wiring beside a leaf are covered in the door entry systems guide, and the gates that move with the traffic are covered in the gate automation guide.
Before the order goes out, each leaf is given its answer for the night the power fails, written beside its door on the order. A leaf with no answer written beside it is a leaf the staff must guess at on the night it matters most.
The port order: every leaf on one list
One list carries the whole port, a line for every door with the leaf, the grade, the lock and the closer beside it, so the door that arrives is the door the terminal, the stores and the control room need. A list that names one leaf for the whole port leaves the fitter guessing which room takes which grade, and a leaf in the wrong room guards the wrong thing.
The port order is priced from the schedule it is built on, with a figure beside every leaf, lock, closer and seal before it goes out, so the terminal, the control room and the stores each carry their own figure. What the schedule must hold is set out in the how to specify security doors guide, and what a higher grade adds is worked through in the security door cost factors guide.
Port doors are tried through the week, a few leaves each day, so none goes untried for long: the terminal front when the port opens, the stores door before the first ship, and the control room door at closing. A leaf that drags, a closer that has lost its pull, or a seal that has slipped from its groove is noted against its door on the day it is found, with the part and the date beside it. The fire door inspection checklist sets out what a visit should look for, and the security door maintenance checklist covers the doors that must hold both fire and forced entry.
| Position | Door | Grade | What to check |
|---|---|---|---|
| Terminal front | Glazed leaf | LPS 1175 B3 | Leaf, glass, reader |
| Stores | Steel leaf | LPS 1175 C5 | Leaf, lock, seals |
| Workshops | Steel leaf | LPS 1175 C5 | Leaf, lock, seals |
| Control room | Steel leaf | LPS 1175 D10 | Leaf, lock, reader |
| Gatehouse | Steel leaf | LPS 1175 C5 | Leaf, closer, lock |
On a port the grade, the period and the lock decide together whether the terminal, the stores and the control room hold, so all three sit on the same list before the order goes out.
What grade should a port door carry?
The grade follows the room behind the leaf: B3, C5 or D10 to LPS 1175, with the control room taking a higher category than the terminal front beside it.
Can one leaf hold fire and forced entry?
Yes, when one leaf was proved for fire and for forced entry on the same doorset, so a single report holds the proof for both jobs.
Do port doors need access control?
The doors behind the terminal counter take a reader beside the leaf, so the leaf opens for staff and stays shut for the public.
What period should a port door carry?
The door takes FD30 or FD60 to EN 1634-1, and the letters beside the minutes name what the doorset held back. Which of the two periods the door takes depends on the room behind the leaf.
Who checks the port doors?
The duty manager walks the round that covers every door, and the record of each visit stays with the port file.