Depot Security Doors Explained
A depot guards vehicles, fuel and stores behind its yard gate, so each leaf takes the grade the room behind it demands, from gatehouse to plant room.
- ✓Third-party test evidence with every product
- ✓Written specification you can issue to tender
- ✓Supplied and installed across the UK
Get a free project quote
Rating, written specification and budget range within one working day.
Confidential. No cost, no obligation.
Third-party tested
Evidence with every quote
UK manufactured
Made to your sizes
One accountable team
Specify, supply, install
Confidential handling
Details never shared
A depot is a yard, a set of workshops and rows of stores behind one gate, and the doors between those parts decide what stays where it belongs. The yard holds the vehicles, the workshops hold the tools, and the offices behind them hold the keys, the takings and the plant, so each door takes its proof from the room behind it.
LPS 1175 sets the grade on a depot door, and the category follows what sits behind the leaf. Issue 8.2 of September 2024 names the three categories B3, C5 and D10, at three, five and ten minutes. The entrance takes the lowest of the three, the workshops take the middle one, and the cash room takes the highest.
A depot follows the same rules as any other commercial building, and the fire door regulations commercial buildings guide covers the shared parts, while the warehouse security doors guide covers the stores beside the workshops. The depot order names every door, with the grade and the lock beside each one, so the door that arrives is the door its room asked for.
- LPS 1175 B3 / C5 / D10Forced entry grades to Issue 8.2
- WorkshopsWhere the grade rises
- FD30 / FD60Fire periods to EN 1634-1
- One listEvery depot door named
Workshops, stores and offices: one depot, three grades
Three parts make up a depot, and the grade follows what each part holds. The yard holds the vehicles, the workshops hold the tools, and the cash room holds the money the day has taken, so each part takes the doors its work demands.
The entrance leaf opens for every driver who arrives and shuts behind them on its own, because a leaf left standing open guards nothing. The workshop leaf is never seen by the public, and it must hold against the attack the tools behind it invite.
The order is written from a list that names every opening, the leaf it takes and the grade beside it, because a leaf with no line on the list may turn up in the wrong workshop.
The entrance and the gatehouse: the leaves every driver passes
An entrance leaf has two jobs at once: to open for every driver who arrives, and to hold an intruder out once the depot shuts. The leaf, the frame and the lock are proved as one doorset, and the test report names all three.
A closer pulls the entrance leaf shut after every driver who passes, because a leaf left standing open guards nothing. The closer is set so the leaf comes home without a slam, and the pull is checked by opening the leaf and watching it shut on its own.
A glazed panel in the entrance leaf lets the gatehouse see who waits outside before the leaf opens, and the glass takes the same proof as the leaf round it. The fire rated glass cost guide works through what the pane adds to the order, and the test report names the bead and the fixings that hold it.
Workshops and stores: the doors behind the yard
Behind every workshop door sit the tools the depot runs on, and the leaf that guards them takes the grade the value behind it demands. C5 suits the workshops, because the tools behind them justify the minutes it takes to break through, and the leaf must hold until the alarm is answered.
Only the depot team holds the key to the workshops, because drivers must never pass them alone. The workshop leaf takes C5, the cash room beside it takes D10, and the entrance takes B3.
The workshop leaf shuts out the sound of the yard as well as an intruder, so the office stays quiet while vehicles move through. Seals round its edges and a closer that brings it home after every member of staff who passes do that work.
The workshops need a leaf that holds fire back and holds an intruder out, so one doorset carries both proofs. The fire side is proved to EN 1634-1 in E, EW and EI with minutes from 30 to 120, and the forced entry side to LPS 1175 in B3, C5 and D10, with the leaf, the frame and the seals facing both tests together so one report holds both proofs. How one doorset carries both proofs is worked through in the fire and security doors dual certification guide.
The cash room and the office: where the takings and the keys sit
The cash room takes the highest grade on the depot, because the takings sit behind its leaf. The leaf, the frame, the fixings and the lock are proved together as one doorset, and the report names each part, so the door that arrives is the door that was proved.
D10 suits the cash room, because it must hold longest, while the workshops beside it take C5 and the entrance takes B3. Drawings drawn before Issue 8 call the same three categories SR2, SR3 and SR4, so the order carries the new name beside the old one.
The office next to the cash room holds the records and the keys, so its leaf takes the same care. C5 suits the office leaf, and the lock on it takes the same key as the cash room, so one key opens both doors for the staff who work there. The faults that break a rating once a door is fitted are named in the keeping an LPS 1175 rating valid guide.
Plant rooms and the delivery bay: the doors that keep the depot running
The plant room holds the services that keep the depot running, and its leaf takes the grade the value behind it demands. C5 suits the plant room, because the boards and the plant behind it justify the minutes it takes to break through.
Deliveries reach the depot through the bay, so its leaf must be wide enough for pallets and forklifts, with a closer that pulls it shut after each load. The delivery bay leaf takes C5, because the stock passing through it is worth the minutes it takes to break through, and the leaf, the frame, the fixings and the lock are proved together as one doorset, with the report naming the grade the leaf holds. The loading bay doors guide covers the doors that take the deliveries in, and the plant room door requirements guide sets out what the plant room leaf must do.
A delivery bay leaf held open through the working day needs a hold-open device proved to BS EN 1155, which shuts the leaf on its own the moment the alarm sounds.
The leaf hangs with a 4 mm gap round it, so it swings free and the seal meets the frame when the leaf shuts. As the heat climbs toward 200 to 250 degrees the intumescent seal swells to close that gap, unless paint over the seal stops it swelling.
The way out for a full depot: escape routes drivers can follow
A depot alarm sends drivers and fitters to the marked way out, and nothing may stand on it. The leaves on that way open under one push from the first person to reach them, and they open the same way when the supply has failed.
The doors on the route take a smoke rating beside the fire period, proved to BS EN 1634-3. The rating has two marks, Sa for smoke at room temperature and S200 for smoke at 200 degrees, and either mark works only where the seal meets the frame all round, because smoke reaches the route before the flames do. How the doors hold smoke back while people move past them is set out in the smoke control doors guide.
No leaf on the route takes a shorter proof than the route needs, because the route holds only as long as its weakest leaf. A leaf that gives way first takes the route with it, so every leaf on the route carries the same period.
| Position | Door | Grade | What to check |
|---|---|---|---|
| Entrance | Glazed leaf | LPS 1175 B3 | Leaf, glass, closer |
| Workshops | Steel leaf | LPS 1175 C5 | Leaf, lock, seals |
| Stores | Steel leaf | LPS 1175 C5 | Leaf, lock, seals |
| Office | Steel leaf | LPS 1175 C5 | Leaf, lock, reader |
| Cash room | Steel leaf | LPS 1175 D10 | Leaf, lock, reader |
| Plant room | Steel leaf | LPS 1175 C5 | Leaf, lock, seals |
| Delivery bay | Steel leaf | LPS 1175 C5 | Leaf, closer, lock |
Locks, fobs and the depot team: who opens which door
The depot team moves from the gatehouse through the workshops to the plant room and back, and every leaf on that route opens for staff and stays shut for drivers after hours. Beside each leaf on the route sits a reader, and it opens for the passes the list names. What the lock the key turns must do is set out in the fire door hardware guide.
The door entry systems guide covers the readers, the releases and the wiring that sit beside a leaf.
Beside each door on the order sits the answer for the night the power fails, so every leaf knows whether it opens or stays shut when the supply goes. A door with no answer beside it leaves the depot team guessing on the night the answer matters most.
The depot order: every leaf on one list
The whole depot order sits on one list, a line for every door with the leaf, the grade, the lock and the closer beside it, so the door that arrives is the door its room asked for. A list that names a single leaf for the whole depot leaves the fitter to guess which room takes which grade, and a leaf in the wrong room guards the wrong thing.
Each door on the order carries its own figure, and the figures are checked against the schedule one door at a time before the order is sent, because a door left off the quotation is a door the depot still pays for, and a part added once the order has gone out costs more than the same part added before it. The how to specify security doors guide lists what the schedule must hold for every door, and the security door cost factors guide sets out what each step up the grade adds to the figure.
Doors on the depot are tried through the week, a few leaves each day, so none goes untried for long: the entrance at opening, the workshop door before the first vehicle leaves, and the cash room door at closing. A fault goes in the record against its own door on the day it is found, with the part and the date beside it, so the repair is booked before the next day starts. The fire door inspection checklist sets out what a visit should look for, and the doors that must hold both fire and forced entry are covered in the security door maintenance checklist.
A depot door holds only as long as the workshops behind it and the yard beside it, so the grade, the period and the lock must all sit on the same list.
What grade should a depot door carry?
B3, C5 or D10 to LPS 1175, and the room behind the leaf decides which of the three it needs, with the cash room taking the highest category on the depot.
Can one leaf hold fire and forced entry?
Yes, a doorset that faced both tests together, fire and forced entry on the same leaf, frame and seals, holds one report for the pair.
Do depot doors need access control?
The doors behind the gatehouse take a reader beside the leaf, so the leaf opens for the depot team and stays shut for drivers after hours.
What period should a depot door carry?
FD30 or FD60, proved to EN 1634-1, with the period set by the room the leaf guards, and the letters beside the minutes naming what the doorset held back.
Who checks the depot doors?
The depot manager walks the round that covers every door, and the record of each visit stays with the depot file.
Get a free quote
Related
More in guides for specifiers
Products
One supplier for the whole building envelope
Ready to specify your project?
Free assessment, written specification and test evidence. Reply within one working day.