ArxBridge
Petrol Station Security Doors
A petrol station guards cash, stock and fuel controls behind its doors, so each leaf takes the grade the room behind it demands, from the kiosk to the yard.
- ✓Third-party test evidence with every product
- ✓Written specification you can issue to tender
- ✓Supplied and installed across the UK
Get a free project quote
Rating, written specification and budget range within one working day.
Confidential. No cost, no obligation.
Third-party tested
Evidence with every quote
UK manufactured
Made to your sizes
One accountable team
Specify, supply, install
Confidential handling
Details never shared
A petrol station is a shop, a store and a fuel yard under one canopy, and the doors between those parts decide what stays where it belongs. The forecourt holds the pumps and the drivers, the kiosk holds the till and the shelves, and the back rooms hold the stock, the takings and the fuel controls, so each door takes its proof from the room behind it.
LPS 1175 sets the grade on a forecourt door, and the category follows what sits behind the leaf. B3 holds for three minutes, C5 for five and D10 for ten, all to Issue 8.2, dated September 2024. The kiosk front takes the lowest of the three, the store takes the middle one, and the cash office takes the highest.
A shop on a forecourt follows the same rules as any other shop, and the fire door regulations retail guide covers the shared parts, while the retail security doors guide covers the shopfront leaves. Every door on the forecourt goes on one order, with its grade and its lock beside it, so what arrives matches what each room asked for.
- LPS 1175 B3 / C5 / D10Forced entry grades to Issue 8.2
- Night hatchServing drivers after the doors shut
- FD30 / FD60Fire periods to EN 1634-1
- One listEvery forecourt door named
The kiosk, the store and the cash office: one forecourt, three grades
A petrol station splits into three parts, and the grade follows what each part holds. The kiosk serves the drivers, the store feeds the shelves, and the cash office holds the money the day has taken, so each part takes the doors its work demands.
The kiosk takes the doors the public walks through all day, and each leaf must open for a driver with a coffee in one hand and shut behind them on its own. The store door never meets the public, and it must hold against the attack the goods behind it invite, because the shelves are worth the effort of breaking in.
The schedule comes first: every opening on the forecourt, the leaf it takes and the grade beside it. Without a line on that schedule, a leaf may arrive for the wrong room and guard the wrong thing.
The kiosk front: the leaf the public meets day and night
The kiosk front is glass from the counter to the roof, and the doors in it are glazed leaves that let the staff see the forecourt while they serve. A glazed leaf takes the same proof as the leaf beside it, because a pane that fails lets the leaf fail with it.
The test report names the bead and the fixings that hold the pane, and the frame beside the leaf carries the same proof as the leaf itself. The fire rated glass cost guide works through what the glass itself costs, and the ballistic glass ratings guide sets out the panes that carry a ballistic rating.
The kiosk leaf takes a closer that brings it home after every driver who passes, because a leaf that stands open after closing lets the cold in and the takings out. The closer is set so the leaf comes back to the frame without a slam, and the pull is checked by opening the leaf and letting it go.
The night hatch and the counter: serving drivers after the doors shut
After the kiosk doors shut for the night, the hatch takes over. A driver pays through the hatch and the goods pass back the same way, so the hatch leaf takes C5, the same grade as the store door behind the counter, while letting a hand and a card through.
The hatch is proved as one doorset with its frame and its lock, and the report names all three, so the hatch that arrives is the hatch that was tested. The counter beside it takes the same grade as the hatch, because the till sits behind both.
A kiosk that trades through the night takes a leaf wide enough for the hatch and the till, and the glass above the counter takes the same proof as the leaf. The bullet resistant glass cost guide works through what the kiosk glass costs.
The stock room and the back office: where the value waits
Behind the kiosk, the stock room holds the goods the shelves will need next, and its leaf takes the grade the value behind it demands. C5 suits the store, because the goods behind it justify the minutes it takes to break through, and the leaf must hold until the alarm is answered.
The back office beside the store takes the same care, because the records and the keys sit behind its doors. Its leaf takes a lock the manager controls, and the doorset is proved as one piece, leaf, frame and lock together, with the report naming each part.
The delivery bay takes the goods in from the yard, and it takes a leaf wide enough for pallets and a closer that pulls it shut after each load. Its leaf, frame, fixings and lock are proved as one doorset, and the report carries the grade the leaf holds.
The cash office: the highest grade on the forecourt
No room on the forecourt takes a higher grade than the cash office, because the takings, the keys and the records sit behind its leaf. The cash leaf takes D10, because it must hold longest, while the store beside it takes C5 and the kiosk front takes B3.
Drawings drawn before Issue 8 call the same three categories SR2, SR3 and SR4, and the order carries the new name beside the old one. No published table converts an LPS 1175 category into a category from another standard, so the order names LPS 1175 on its own.
The manager holds the key to the cash office, and its leaf is proved with its frame and its lock as one doorset, the report naming each part. What breaks a rating once a door is fitted is named in the keeping an LPS 1175 rating valid guide.
Fire and fuel on the same leaf: one doorset, two proofs
A forecourt leaf can be proved for fire and for forced entry on the same doorset, because the kiosk needs the fire held back while the cash office needs an intruder held out. The fire proof comes from EN 1634-1, in E, EW and EI with minutes from 30 to 120, and the forced entry proof comes from LPS 1175, in B3, C5 and D10. The leaf, the frame and the seals face both tests together, so the proof for fire and the proof for forced entry sit on one report. The fire and security doors dual certification guide works through how one doorset carries both proofs.
The period follows the room behind the leaf, because the kiosk, the store and the fuel controls ask different things of the leaf, and the grade follows the value behind it. The minutes run from 30 to 120, and the letters beside the number say what stayed back: flames on their own, flames with some heat, or flames with the heat as well. The route doors carry a smoke proof beside the fire proof, to BS EN 1634-3, with Sa for smoke at room temperature and S200 for smoke at 200 degrees. The smoke control doors guide covers how the doors hold smoke back while people move past them.
A 4 mm gap sits round the leaf, so it swings free and the seal meets the frame all round. Heat near 200 to 250 degrees makes the intumescent seal swell, closing the gap the leaf leaves.
Locks, fobs and the fuel controls: who opens which door
Staff move from the kiosk through the store to the back office and back, and every leaf on that route opens for staff and stays shut for the public. Each leaf on the route takes a reader beside it, and the fobs the list names open the doors the list allows. What the lock the key turns must do is named in the fire door hardware guide.
The fuel controls sit behind a leaf of their own, and only the staff who run the forecourt hold its key. The tank gauges, the shut-off and the delivery records sit behind that leaf, so it takes the same grade as the cash office beside it. Readers, releases and wiring beside a leaf are covered in the door entry systems guide.
Every leaf gets its answer for the night the power fails before the order goes out. Each answer is written beside its door on the order, so no leaf is left to guess on the night the power fails.
The forecourt order: every leaf on one list
One list carries the whole forecourt, a line for every door with the leaf, the grade, the lock and the closer beside it, so the door that arrives is the door the kiosk, the store and the cash office need. A list that names one leaf for the whole forecourt leaves the fitter guessing which room takes which grade, and a leaf in the wrong room guards the wrong thing.
The forecourt order is costed from the list the order is built from, with a figure beside every leaf, lock, closer and seal before it goes out, so the kiosk, the cash office and the delivery bay each carry their own number. What the list must hold is set out in the how to specify security doors guide, and what a higher grade adds is worked through in the security door cost factors guide.
The manager tries the forecourt doors through the week, a few leaves each day, so no door goes untried for long: the kiosk front at opening, the store door before the first delivery, and the cash office door at closing. A leaf that drags, a closer that has lost its pull, or a seal that has come away from its groove is written beside the door it belongs to, with the part and the day it was found. What a visit should look for is listed in the fire door inspection checklist, and the security door maintenance checklist covers the doors that must hold both fire and forced entry.
| Position | Door | Grade | What to check |
|---|---|---|---|
| Kiosk front | Glazed leaf | LPS 1175 B3 | Leaf, glass, reader |
| Night hatch | Steel leaf | LPS 1175 C5 | Leaf, lock, hatch |
| Store | Steel leaf | LPS 1175 C5 | Leaf, lock, seals |
| Cash office | Steel leaf | LPS 1175 D10 | Leaf, lock, reader |
| Delivery bay | Steel leaf | LPS 1175 C5 | Leaf, closer, lock |
On a forecourt the grade, the period and the lock decide together whether the kiosk, the store and the cash office hold, so all three sit on the same list before the order goes out.
What grade should a petrol station door carry?
The grade follows the room behind the leaf: B3, C5 or D10 to LPS 1175, with the cash office taking a higher category than the kiosk front beside it.
Can one leaf hold fire and forced entry?
Yes, where a single doorset went through both tests, fire and forced entry, so one report holds the proof for both jobs.
Do petrol station doors need access control?
The doors behind the kiosk counter take a reader beside the leaf, so the leaf opens for staff and stays shut for the public.
What period should a petrol station door carry?
FD30 or FD60 to EN 1634-1, with letters beside the minutes naming what the doorset held back, and the room behind the leaf decides which period the door takes.
Who checks the petrol station doors?
The manager walks the round that covers every door, and the record of each visit stays with the forecourt file.
Get a free quote
Related
More in guides for specifiers
Products
One supplier for the whole building envelope
Ready to specify your project?
Free assessment, written specification and test evidence. Reply within one working day.