Fire Door Rules for Petrol Stations
A petrol station holds fuel, cash and stock behind its kiosk counter, so each fire door takes its period from the room behind it and the way out.
- ✓Third-party test evidence with every product
- ✓Written specification you can issue to tender
- ✓Supplied and installed across the UK
Get a free project quote
Rating, written specification and budget range within one working day.
Confidential. No cost, no obligation.
Third-party tested
Evidence with every quote
UK manufactured
Made to your sizes
One accountable team
Specify, supply, install
Confidential handling
Details never shared
A petrol station is a shop, a store and a fuel site under one roof, and the fire doors must hold the fire where it starts while drivers and staff reach the way out. The leaf holds fire back for its period, and it opens for people who have never walked the route, so each door takes the period the room behind it demands.
The period on a forecourt door follows the room behind the leaf, because the kiosk, the stores and the back office ask different things of the doors that guard them. The order carries the period beside each opening, so the leaf that arrives is the leaf the room needs.
The rules for the shared parts of a shop are set out in the fire door regulations retail guide, and the rules for the stores beside the kiosk are set out in the fire door regulations warehouses guide. The forecourt order names every door in the building, with the period and the hardware beside each one.
- FD30 / FD60Fire periods to EN 1634-1
- E / EW / EI 30-120What the letters beside the period mean
- 4 mmThe gap round the leaf
- One listEvery forecourt door named
Kiosk, stores and back offices: one forecourt, three parts
A petrol station is three buildings in one: the kiosk where the drivers pay, the stores where the goods wait, and the back office where the records sit. The rules follow those parts, because a door between one part and the next must hold the fire where it started while the drivers reach the way out.
The kiosk takes the doors that let a driver in and out, and each leaf must open for people who have never seen the building before. The stores take the doors that guard the goods, and each leaf must hold fire back where the stock sits. The route that joins them takes the doors the staff pass through, and each leaf takes the period the escape needs.
The forecourt writes its fire strategy first, naming every opening with the door beside it, and the order follows the strategy, so no leaf is ordered without the room it guards behind it.
FD30 and FD60 on a forecourt: the periods each room takes
Each part of a forecourt asks a different period of its doors, because the load behind each leaf is different. The kiosk holds the drivers and the goods on the shelves, the stores hold the goods in boxes and crates, and the back office holds the records, so the period on each door follows the room, not the leaf.
EN 1634-1 is the test behind every fire door, and its result is written as minutes with letters beside them. Thirty minutes is the shortest proof on the scale and 120 the longest, while the letters say what the leaf held back: flames alone, flames with some heat, or flames with the heat as well. Minutes without letters say only half of what the door proved, so the order names both together.
A leaf that must hold for longer weighs more, and the frame that carries it runs deeper, so the figure on the quotation rises with the weight. Where an opening needs 60 minutes, a leaf proved for 30 has no place in it, because the shorter leaf is the one that gives way first.
The kiosk: glass, tills and the doors between the counter and the stock
The kiosk is mostly glass, and the doors on it must hold their proof while letting drivers see the tills beyond them. A glazed leaf lets a driver see the counter without opening the leaf, and the pane takes the same proof as the leaf, because the leaf and the glass are proved as one doorset. The bead and the fixings the test report names are written on the order beside the glass.
The goods on the kiosk shelves carry a fire load of their own, and the doors between the kiosk and the stores must hold the fire where it starts. A leaf between the kiosk and the stores takes the period the stores demand, because the fire that starts among the goods must stay among the goods while the drivers move out.
Windows on the same wall are covered in the fire rated windows guide, and the fire rated glass cost guide sets out what the glass itself costs.
Stores and the fuel controls: the doors behind the counter
The stores take the heaviest fire load on the forecourt, because the goods sit there in boxes and crates all day. A store leaf takes FD60 where the load is heaviest, and the period follows the fire load, not the size of the kiosk.
The fuel controls sit behind their own door, because the pumps and the tanks are shut down from the kiosk. A leaf that guards the fuel controls takes FD60, and it shuts after every person who passes, because a leaf left open lets smoke reach the route before the drivers do.
The stores take doors that stand open through the day, so the staff can move goods without stopping at every leaf. A leaf that must stand open takes a hold-open device proved to BS EN 1155, so the leaf shuts on its own the moment the alarm sounds. A leaf wedged open with a crate holds nothing back when the fire comes, and the wedge belongs in the store, not under the leaf.
The back office and the plant room: the doors that guard the records and the services
The back office holds the records and the takings, and the leaf that guards it takes the period the room beside it takes. A back office leaf takes FD30 where the office sits beside the kiosk, because the fire that starts among the shelves must not reach the records.
The plant room takes the same care, because the electrical boards and the refrigeration plant sit behind its doors all day. A plant room leaf takes FD60, and the gap round it is kept to 4 mm, with the seal checked with the leaf shut.
The kiosk and the stores need a leaf that holds fire and holds an intruder out, so some forecourt leaves carry both proofs at once. What the leaf must hold decides the category: B3 for three minutes, C5 for five and D10 for ten, under Issue 8.2, dated September 2024. The LPS 1175 vs PAS 24 guide shows the two ratings beside each other, and the keeping an LPS 1175 rating valid guide names what can break a rating once a door is fitted. How one doorset carries both proofs is covered in the fire and security doors dual certification guide.
When a back office door stands shut for weeks, the seal tells first
A back office door on a forecourt can stand shut for weeks at a time, because the records inside are fetched only now and then. The plant room door beside it waits the same way, opened only when a contractor calls to service the pumps. A door that waits that long does not stay as it was hung, and the fault shows first where the seal meets the frame, because a strip that has sat pressed against one spot takes the shape of that spot and then sticks when the door is finally pulled.
Heat is what the seal is made for, and the strip stays ready through the quiet weeks. The strip swells once heat passes 200 degrees, and it closes the opening beside the door before the temperature reaches 250. A coat of paint holds the strip down, and a strip out of its groove opens the same gap to flame, so the monthly try must look at the strip as well as the swing. The seals guide gives the heat at which the strip starts to swell and the heat at which it closes the opening.
Hinges stiffen where they sit still, and a lock seizes where its bolt has not moved for a month. The opening left beside a hung door is four millimetres, enough for the door to swing clear and tight enough for the seal to close it, and a hinge that has stiffened lets the door drop until it scrapes the threshold. EN 3 is the lowest closer size BS EN 1154 allows on a fire door, and the back office door is given a size above that mark. The closer guide works through the sizes a forecourt door takes.
| Part | What weeks of stillness do | Monthly try |
|---|---|---|
| Seal | Sticks to the frame in one spot | Strip seated, unpainted, unbroken |
| Hinge | Stiffens and lets the door drop | Door swings free without dragging |
| Lock | Bolt seizes in the keep | Key turns and bolt throws cleanly |
| Closer | Loses pull and stops short | Door meets the frame on its own |
Which part fails first on a door that nobody opens for a month?
The answer is found by trying the door, not by looking at it from the corridor. Each back office and plant room door is pulled wide once a month and left to find its frame, and a door that stops short gets a note beside its room that same day. The hardware guide names the fittings proved with the door, and the gap guide gives the figure the gauge must show against the door.
A door that will not open on the day it is needed holds the records behind it and the plant behind it alike, and a door that will not shut opens the office to vapour from the pumps. The walk that tries them is short, one turn round the back of the building in daylight. The inspection checklist gives the monthly walk its order, room after room, so a quiet month skips none of them.
The back office list goes to the enquiry checklist with the seal, the hinges and the lock written beside the door, so the room that waits weeks still opens on the day it must.
Escape routes on a forecourt: the way out for drivers and staff
The drivers and staff on a forecourt follow the route the building gives them, and the way out must be clear when the alarm sounds. Each door on the route opens with one push from anyone who reaches it, because the leaf must open whether the power is there or not.
The smoke proof on a route door comes from BS EN 1634-3, with Sa for smoke at room temperature and S200 for smoke at 200 degrees. Smoke moves faster than flame, so it reaches the route ahead of the fire, and a seal holds only where it meets the frame all round. How the doors hold smoke back while people move past them is covered in the smoke control doors guide.
The route takes one period on every leaf it passes, because the leaf with the shortest proof decides how long the route stands. No leaf on the route takes a shorter proof than the leaves beside it, and the leaf that fails first is the leaf the route cannot spare. The doors that guard a warehouse are covered in the warehouse security doors guide, and a forecourt takes the same care with its stores as a warehouse takes with its own.
| Position | Door | Period | What to check |
|---|---|---|---|
| Kiosk | Glazed leaf | FD30 | Leaf, glass, closer |
| Stores | Steel leaf | FD60 | Leaf, lock, seals |
| Back office | Fire leaf | FD30 | Leaf, lock, closer |
| Plant room | Fire leaf | FD60 | Leaf, seals, gap |
| Public route | Fire leaf | FD30 | Leaf, bar, closer |
The moving parts: closers, seals and the gap on a forecourt leaf
A kiosk leaf opens and shuts all day, so its closer works harder than any other closer on the site. BS EN 1154 sets the smallest power for a fire door closer at EN 3, and the test is to open the leaf and watch it shut on its own. Where the closer has lost its pull the leaf stands open after the driver has passed, and an open leaf holds nothing back.
The leaf is hung with a 4 mm gap beside it, so it swings free and the seal meets the frame all round when the leaf shuts. As the heat climbs towards 200 to 250 degrees the intumescent seal swells and closes the gap the leaf leaves, unless paint over the seal holds it down. When a seal slips from its groove it is noted against its door that same day, with the part and the date beside it.
Each hinge takes its share of the leaf through every opening of the day, and a loose hinge lets the leaf sink month by month until it drags and smoke slips through the gap at the top. What the lock the key turns must do is set out in the fire door hardware guide, and the fire door closers guide covers sizes and fitting.
Which closer pulls a forecourt leaf shut against the wind?
A forecourt never shelters its kiosk leaf. The wind runs straight off the pumps and catches the leaf on every opening, so the closer earns its keep in gusts rather than in calm air. Drivers push through a hundred times a day, and the leaf has to find its frame again after each of them without a hand to help it. BS EN 1154 puts EN 3 as the lowest closer size a fire leaf may take, and a leaf that faces the forecourt wind is given a size above that lowest mark, because a closer at the minimum is the first to lose the fight on a blustery day.
Vapour from the pumps sits low and drifts towards the kiosk, so the strip round the leaf has to touch the frame without a break. Heat does the work: past 200 degrees the intumescent strip swells, and before the temperature reaches 250 it has grown across the opening the leaf leaves. Paint laid over the strip holds it down, and a strip that has worked free of its groove leaves the same opening bare. The seals guide names the temperatures at which the strip starts to grow and the point where it closes the opening.
Four millimetres is the opening left beside a hung leaf, enough for the leaf to swing clear in a gust and narrow enough for the seal to close it. Hinges take the weight of that leaf through a hundred openings a day, and one that loosens lets the leaf drop until it scrapes the threshold and the wind pins it open. Closer sizes for a leaf that faces the wind are listed in the closer guide, and the fittings tested with the leaf are named in the hardware guide.
| Part | What the wind does | Check |
|---|---|---|
| Closer | Pushes the leaf back open | Leaf meets the frame on its own |
| Seal | Dries and shrinks in the draught | Strip seated, unpainted, unbroken |
| Gap | Widens as the leaf sinks | Even round the leaf at 4 mm |
| Hinge | Works loose under daily use | Leaf swings free without dragging |
The seal and the gap earn their check at the end of the day
At the end of trading the leaves are worked in turn, kiosk first and back office last. Each leaf is pushed wide and left to find its frame, and one that stops short is written down beside its door that same night, closer and date alongside, so the mending is booked before the morning drivers arrive. The gap guide names the figure to look for when the gauge goes against the leaf.
A leaf that stays open overnight leaves the kiosk open to vapour and to the wind, and the route beside it loses its guard before the first driver of the morning. After a storm the leaves are tried again, because a gust that throws a leaf back can bend a hinge or shake a fixing loose. The inspection checklist gives the night walk its order, leaf after leaf, so a tired evening skips none of them.
The forecourt order puts the closer, the seal and the opening beside each leaf, and the order goes to the security door enquiry checklist, where each leaf is listed with its period and its closer.
The forecourt order: every door on one list
The forecourt order is written as one list, and each line names a door, its leaf, its period, its lock and its closer, so the door that arrives is the door the room needs. A single leaf named for the whole forecourt leaves the fitter to guess which room takes which period, and a leaf in the wrong room guards the wrong thing.
Before the order goes out the quotation is checked figure by figure against the list, each one sitting beside the door it belongs to, so a figure left off still has to be paid and a part added after the order costs more than the same part ordered with the building. The how to specify security doors guide names the columns the list must hold, and the security door cost factors guide works through what a higher grade adds to the price.
Before the kiosk opens each morning the staff try the leaves in turn, from the kiosk through the stores to the back office. A leaf that drags, a seal that has slipped from its groove, or a closer that has lost its pull is noted against its door on the day it is found, and the repair is booked while the fault is still small. The record stays with the forecourt file, and what the visit should cover is set out in the fire door inspection checklist.
A forecourt leaf holds only as long as the fuel behind it and the route beside it, so the period, the release and the closer must all sit on the same list.
What period should a petrol station door carry?
FD30 or FD60 to EN 1634-1. The letters beside the minutes say what the doorset held back, and the room behind the leaf decides which period the door takes.
Can one leaf hold fire and forced entry?
Yes, when one doorset was tested for fire and for forced entry together, so the one report covers both jobs.
Do petrol station doors need panic hardware?
Yes, the leaf on the way out takes a panic bar proved to BS EN 1125, across at least 60 percent of the leaf, so one push throws the latch for the drivers behind it.
What grade should a store door carry?
The grade follows the room: B3, C5 or D10 to LPS 1175, with the stores taking a higher category than the kiosk.
Who checks the petrol station doors?
The forecourt manager walks the round that covers every door, and each visit is written into the record the forecourt keeps.