A student block holds hundreds of people behind flat doors, so each door takes the grade and period the room behind it demands, flat by flat.
- ✓Third-party test evidence with every product
- ✓Written specification you can issue to tender
- ✓Supplied and installed across the UK
Get a free project quote
Rating, written specification and budget range within one working day.
Confidential. No cost, no obligation.
Third-party tested
Evidence with every quote
UK manufactured
Made to your sizes
One accountable team
Specify, supply, install
Confidential handling
Details never shared
A student block holds hundreds of people behind flat doors, and the doors must work for every one of them. The flat entrance holds the student in and the intruder out, the communal doors take the whole floor through, and the plant room doors guard what the block runs on, so each door takes the grade and the period the room behind it demands.
The grade on a student door is LPS 1175, and the category follows the room behind the leaf. Under Issue 8.2, dated September 2024, B3 holds three minutes, C5 holds five and D10 holds ten. The flat entrance takes the lowest grade of the three, the communal doors take a higher one, and the room that holds the plant takes the highest.
The rules for the block are set out in the fire door regulations student accommodation guide, and the rules for the shared parts of a public building are set out in the fire door regulations commercial buildings guide. The block order names every door in the building, with the grade and the lock beside each one, so the door that arrives is the door the flat needs.
- LPS 1175 B3 / C5 / D10Forced entry grades to Issue 8.2
- Flat entrancesWhere the grade starts
- FD30 / FD60Fire periods to EN 1634-1
- One listEvery block door named
Flat entrances, communal areas and plant rooms: one block, three grades
A student block is three buildings in one: the flats where students live, the communal areas they share, and the plant rooms that serve them. The rules follow those parts, because a door between one part and the next must hold the fire on the side where it started while the students reach the way out.
The flat takes the doors the students lock behind them, and each leaf must hold against the attack the flat behind it invites. The communal areas take the doors the whole floor passes through, and each leaf takes the period the way out needs.
The block schedule is written before the order goes out, naming every opening and the grade beside each one. A leaf ordered without a line on the schedule may arrive for the wrong flat, and the wrong leaf on a flat entrance guards nothing.
The flat entrance door: the leaf a student locks behind them
The flat entrance door takes two jobs at once. It must hold an intruder out for its rating, and it must hold fire back for its period, so the leaf, the frame and the lock are proved together as one doorset, and the report names each one.
The flat leaf takes a lock the student controls from inside, because the student must be able to lock the door behind them, and the warden must still be able to open it from outside. A leaf that cannot be opened by the staff who run the block is a leaf that traps the student behind it. The lock the key turns is covered in the security door locks guide.
A glazed flat leaf lets the student see who stands outside before the leaf opens, and the pane takes the same proof as the leaf itself. The flat entrance doors guide covers the doors that guard a flat, and the bead and the fixings that hold the pane are the ones named in the test report.
Communal areas: the doors a whole floor shares
The communal areas take the doors the whole floor shares: the kitchen, the lounge and the laundry, and each leaf must open for students who have never touched it before. Each communal leaf takes a release that throws the latch with one push, so the leaf opens even when the power has gone.
The corridor between the communal areas and the flats takes doors that stand open through the day and shut at night. A leaf that stands open through the day takes a hold-open device proved to BS EN 1155, and the device lets the leaf shut on its own when the alarm sounds. A leaf held open by a wedge is a fire door that holds nothing when the fire comes.
The communal doors take the same care as the doors of a leisure building, and the fire door regulations leisure centres guide sets out the rules for buildings that fill with people. The doors that hold smoke back while students move past them are covered in the smoke control doors guide.
The plant room and the bin store: the doors behind the block
The plant room holds the boilers and the machinery that serve the block, and the leaf that guards it takes the grade the machinery behind it demands.
The bin store beside the plant room takes a leaf of its own, because the waste the block throws out draws the people the plant room must keep out. A bin store leaf takes the same grade as the plant room door beside it, and the lock on it takes the same key as the warden’s office.
The plant room leaf takes a closer that pulls it shut after every person who passes, because a leaf left open is a fire door that holds nothing. The closer is set to pull the leaf shut without a slam, and the fitting is proved by opening the leaf and seeing it come home on its own.
The way out for a whole floor: the route that must stay clear
The students in a block follow the route the building gives them, and the way out must be clear when the alarm sounds. Each door on the route opens with one push from anyone who reaches it, because the leaf must open whatever the power is doing.
The route doors take smoke seals proved to BS EN 1634-3, Sa for smoke at room temperature and S200 for smoke at 200 degrees. The seal must meet the frame all round, because smoke moves faster than flame and reaches the students on the route before the fire does. Every leaf on one route takes the same period, because a leaf proved shorter than the leaves beside it is the leaf that fails first.
The stair cores take the doors that keep the way out clear, and each leaf takes the period the stair beside it takes. A fire that starts on one floor must stay on that floor, so the leaf between the floors holds the line while the students move down. The hotel fire doors guide covers the doors that guard sleeping guests, and a student block takes the same care with its stairs.
Access control in a block: fobs, codes and the warden
Access control in a block is a list, and the list decides which fob opens which door. The student fob opens the flat entrance and the communal areas, and the staff fob opens the plant room and the warden’s office as well. A list that gives every fob every door gives the plant room to anyone with a room.
The turnstile at the front takes the students who live there and turns away the ones who do not, and the leaf beside it takes the students who cannot pass through the turnstile. Gates that count people in and out are covered in the security turnstiles guide.
The warden’s office takes the highest grade on the order, because the room behind it holds the keys, the records and the takings. A leaf that guards the keys takes D10, because it must hold longest, while the plant room beside it takes C5 and the flat entrances take B3. The three categories carried the names SR2, SR3 and SR4 before Issue 8, and the order names the category the product was proved under. LPS 1175 categories have no published equivalent in another standard, so the order carries LPS 1175 alone.
One leaf, two proofs: fire and forced entry in a flat
One leaf in a flat can hold fire back and hold an intruder out, because the flat entrance needs both proofs on the same doorset. EN 1634-1 proves the fire side in E, EW and EI from 30 to 120 minutes, and LPS 1175 proves the forced entry side in B3, C5 and D10. Both proofs are run on the same leaf, frame and seals, so one doorset carries the report for both jobs.
The LPS 1175 vs PAS 24 guide puts the two ratings beside each other, and what breaks a rating once a door is fitted is named in the keeping an LPS 1175 rating valid guide.
The gap round the leaf is kept at 4 mm, so the leaf swings free and the seal closes the opening when the leaf shuts. The seal wakes when the heat reaches around 200 to 250 degrees, and paint laid over the seal holds it down, so it cannot swell when the fire comes. The fire and security doors dual certification guide works through how two proofs share one doorset.
The block order: one list for every flat
The block order is written as one list, with a line for every door and the leaf, the period, the lock and the closer beside each one, so the door that arrives is the door the flat, the corridor and the plant room need. A list that leaves the period off a line leaves the fitter guessing, and a leaf ordered on a guess carries no proof.
Every leaf, lock, closer and seal on the block is priced from the list before the order goes out, line by line, so a flat entrance, a communal door and a plant room door each carry their own figure. The security door cost factors guide works through what each step up the scale adds to the price, and the how to specify security doors guide sets out the columns the list needs.
The warden tries every door in the block on the same round: the flat entrances on each floor, the communal doors, the plant room and the bin store, one floor at a time from the top down. A fault is noted at the door where it was found, with the leaf, the part and the date beside it, so the repair is booked before the next term starts. What a visit should look for is set out in the fire door inspection checklist, and the security door maintenance checklist covers the doors that must hold both fire and forced entry.
| Position | Door | Grade | What to check |
|---|---|---|---|
| Flat entrance | Steel leaf | LPS 1175 B3 | Leaf, lock, seals |
| Communal area | Fire leaf | FD30 | Leaf, closer, seals |
| Plant room | Steel leaf | LPS 1175 C5 | Leaf, lock, seals |
| Warden’s office | Steel leaf | LPS 1175 D10 | Leaf, lock, reader |
| Stair core | Fire leaf | FD60 | Leaf, bar, closer |
A student door holds only as long as the flat behind it and the route beside it, so the grade, the period and the lock must all sit on the same list.
What grade should a flat entrance door carry?
The grade follows the room behind the leaf: B3, C5 or D10 to LPS 1175, with the flat entrance taking B3 and the warden’s office taking a higher category.
Can one leaf hold fire and forced entry?
Yes, where the leaf, the frame and the lock faced both tests as one doorset, so the proof for fire and the proof for forced entry sit on the same report.
Do student doors need access control?
The flat entrances take a reader so only students and staff walk in, and the list behind the reader decides which fob opens the plant room and the office.
What period should a flat door carry?
FD30 or FD60 to EN 1634-1, with the letters beside the number naming what the doorset held back, and the flat behind the leaf decides which period the door takes.
Who checks the student doors?
The warden walks the round that covers every door, and the record of each visit stays with the building file.