Certified physical security

ArxBridge
Installer checking the seal of navy steel fire-rated doors in a UK office corridor

ArxBridge

Fire Door Vision Panels

A vision panel lets people see through a fire door before they open it. The pane, the bead and the fixings go to the test with the leaf as one doorset.

  • ✓Third-party test evidence with every product
  • ✓Written specification you can issue to tender
  • ✓Supplied and installed across the UK
Prefer to talk?+44 7352 267239

Get a free project quote

Rating, written specification and budget range within one working day.

ArxBridge Quote Form

Confidential. No cost, no obligation.

Third-party tested

Evidence with every quote

UK manufactured

Made to your sizes

One accountable team

Specify, supply, install

Confidential handling

Details never shared

A fire door with a glazed panel lets the person on one side see the person on the other before the leaf moves. On a corridor where people walk fast and a stair core where a crowd leaves at once, the pane stops two people meeting in the doorway, and it lets a member of staff see whether the room beyond is clear before they push the leaf open.

The panel is not a hole cut in the leaf after the door is made. The pane, the bead and the fixings are proved with the leaf, the frame and the seals as one doorset, and the proof names the pane the test used. A pane fitted to a leaf that was never proved with glass leaves the door different from the one tested.

The cost of the glass itself is worked through in the fire rated glass cost guide, and the hardware beside the leaf is covered in the fire door hardware guide. A panel ordered without the leaf it belongs to may land on the wrong door, so the pane, the bead and the leaf belong on the same line of the order.

  • FD30 / FD60Fire periods to EN 1634-1
  • 500 to 1,500 mmThe viewing zone on the leaf
  • Bead and tapeThe fixings that hold the pane
  • One scheduleEvery glazed door on one line

Seeing through the leaf: why a fire door takes a pane

A corridor door opens both ways, and the person pushing it cannot see the person coming the other way. A pane in the leaf shows the corridor beyond, so the person pushing slows down and the person on the other side steps aside, and the leaf never strikes anyone.

On an escape route the pane does a second job. A member of staff at the stair door can see whether the stair is full of smoke before they open the leaf, and a person leaving a room can see whether the corridor beyond is clear before they step out.

A pane also lets light through a leaf that would otherwise shut the corridor off from the rooms beside it. A school corridor, a hospital corridor and an office floor each take leaves that let daylight reach the rooms behind them, and the pane in each leaf keeps the corridor from feeling like a tunnel. The periods for the shared parts of a school are set out in the fire door regulations schools guide, and the doors on a hospital site are covered in the hospital security doors guide.

A pane that nobody can see through has stopped doing its job, even when the glass is sound and the door still shuts. A poster goes up over it for a week and stays for a year, a notice is taped across the middle because the wall beside the door is full, and the round walks past a door that looks shut while the room beyond it cannot be seen at all. The pane is there so a person can look before pushing the door open, and a pane that is covered is a pane that has been taken away.

One poster over the pane, and the round sees nothing

The poster is put up by someone who never thinks of the pane as part of the door. It covers the glass, it hides the bead behind it, and it stays because nobody owns the job of taking it down. The round should lift every poster and notice from the glass, check the pane behind it, and put the notice on the wall beside the door instead.

The bead is the part the poster hides best. A bead that has worked loose sits behind the paper, and a bead that has been painted over cannot be seen until the paper comes off. The fixings that hold the bead are listed in the fire door hardware guide and the order names the strip the report names.

Notices breed notices. One poster on the glass gives the next person permission to add another, and the pane ends up covered edge to edge. Glazed doors get a line of their own on the round, and the pane is named on the fire door inspection checklist so the glass is looked at on every visit.

Need this specified for your project?Free rating, written specification and budget range within one working day.
Get a free quote

The bead sits behind a sign, so the round walks past the pane

Cleaning does its own quiet damage. The wrong product leaves a film on the glass that clouds it a little more each week, and the pane grows milky while the door still looks clean. A product made for plain glass may not suit a proved pane, so the cleaner used on the pane is named on the round sheet and nothing else is used on it.

A pane that must stand up to fire and to attack at once needs glass proved for both, and the dual certification guide shows how the two proofs sit together, while the fire rated glass cost guide lists the glass kinds the order may name.

Glass in the wall beside the door is proved to the period the glass in the door carries, and the fire rated windows guide deals with those panes, while a pane that has clouded past seeing through is noted on the round sheet beside a pane that has cracked.

What covers the pane What it hides What the round does
Poster The room beyond Taken down and the pane checked
Notice taped across The bead and its fixings Notice moved to the wall beside the door
Wrong cleaning product Clear glass under a film Cleaner named on the round sheet

Put the pane, the bead and the size on one line of the order, and the security door enquiry checklist wants the glass on it to match the glass in the report.

The glass that holds fire: what the pane must prove

The glass in a fire door is not the glass in a window. It must hold fire back for the same period as the leaf beside it, and the proof is measured in E, EW and EI from 30 to 120 minutes under EN 1634-1, the same letters that sit beside the period on the leaf.

Three kinds of glass meet a fire door: wired glass with a mesh inside it, borosilicate glass that takes heat without breaking, and laminated glass with a layer that turns opaque as it swells. Each one holds the fire in a different way, and the test report names the glass the leaf was proved with.

A pane that holds fire in one frame can fail in another, because the bead, the tape and the fixings round the pane decide whether the glass stays in place while the furnace runs. The glass, the bead and the fixings go to the test with the leaf, and the report names them all.

The bead and the tape: the fixings that hold the pane

The bead is the strip that holds the pane in the leaf, and it takes the same care as the frame. A steel bead holds the pane through the fire, while a timber bead must be proved with the leaf it sits in, and the bead that arrives with the door is the bead the test used.

Intumescent tape sits between the bead and the pane, and it swells when the heat rises, closing the gap round the glass before the flames can reach it. A bead fitted without its tape leaves the pane loose in the leaf, and a pane that rattles in its bead will not hold its line in a fire.

The fixings that hold the bead take the size and the spacing the test report names. A screw left out, or a bead fixed with the wrong fixing, leaves the pane held by less than the proof assumed, and the door that arrives is not the door that was proved.

A pane that has cracked, or a pane that took a blow in a break-in attempt, cannot stay in the leaf. The replacement must match what the test proved, glass for glass, bead for bead, size for size, because the proof belongs to the pane that was tested, not to the pane that happens to fit the hole.

A cracked pane is replaced like for like, or the proof goes with it

The first question after a crack is what glass the leaf was proved with. Wired, borosilicate or laminated, each one holds fire in its own way, and the replacement must be the same kind, because a pane of the wrong kind leaves the leaf with a proof for glass it no longer carries. The report is read before the order is written, so the glass on the order is the glass the leaf was tested with.

The bead and the tape go with the glass, because the pane is held by all three together. A replacement that names the glass but not the bead leaves the fitter to guess which strip holds the new pane, and a guess is not a proof.

The fire rated glass cost guide works through the glass kinds the order can name, so the pane that arrives is the pane the test report names. The fixings that hold the bead are checked in the fire door hardware guide, so the parts on the order match the parts in the report.

Measure the replacement against the report, not against the hole in the leaf

The hole in the leaf is the wrong measure for the replacement, because a pane cut to fill it may be larger than the test allows. The size on the order comes from the report, and the report names the largest pane the leaf may carry.

A replacement pane set higher than the one it replaces changes what the people behind the door can see, so the height is set by the people who use the door, not by the shape of the hole.

Glass in the wall beside the door takes the same period as the glass in the leaf, and the fire rated windows guide covers those panes, while a leaf that must hold fire and resist attack at once takes glass proved for both, as the dual certification guide explains.

Each visit walks the glazed doors in turn, and the fire door inspection checklist is the list the round follows, so a crack is written against the right leaf before the pane gives way.

What is replaced Match it to What voids the proof
Glass Kind named in the report Wrong kind of glass
Bead and tape Size and spacing in the report Bead fitted without tape
Pane size Largest size the test allows Pane larger than the test

The pane, the bead and the size go on the order together, and the security door enquiry checklist is the last check before it goes out, so the glass on the order is the glass the report names.

The size of the pane: what the test allows

A vision panel takes a size the test evidence allows, and a larger pane takes a different proof from a smaller one. A leaf proved with a small rectangular pane carries no proof for a leaf with a pane twice its size, because the glass, the bead and the leaf behave differently when the pane grows.

The shape of the pane follows the leaf and the room behind it. A narrow rectangular pane suits a corridor door where people pass at speed, while a circular porthole suits a door where the view matters more than the light, and the shape on the order is the shape the test proved.

A pane that runs most of the height of the leaf is a different door from a leaf with a small panel at eye height, and the order names the size, the shape and the glass together, so the door that arrives matches the door that was proved. The windows that share the same wall are covered in the fire rated windows guide, and the glass in those windows takes the same period as the doors beside them.

Where the pane sits: the height that lets people see

A vision panel sits where the people who use the door can see through it, and the viewing zone runs from 500 mm to 1,500 mm above the floor, so a child, a person in a wheelchair and a person standing can each see through the same pane.

A pane set too high shows only the ceiling to the person in a wheelchair, and a pane set too low shows only the floor to the person standing. The height on the order follows the people who use the door, not the look of the leaf.

The force to open the leaf must stay below 30 N for the first 30 degrees of travel and below 22.5 N beyond, under BS 8300 and Approved Document M, and a leaf that is hard to open keeps people from using the door at all, pane or no pane. The closers that pull the leaf shut are covered in the fire door closers guide.

One leaf, two proofs: fire and forced entry through glass

A leaf can carry two proofs at once, because the door on an office floor must hold fire back and hold an intruder out at the same time. The fire proof is measured in E, EW and EI from 30 to 120 minutes under EN 1634-1, and the forced entry proof is LPS 1175, with B3, C5 and D10 holding three, five and ten minutes.

The glass in such a leaf takes the same grade as the leaf beside it, because an intruder who cannot break the leaf will break the pane instead. A pane proved for fire alone leaves the door open to the attack the leaf was built to resist, so the glass takes the rating the room behind the leaf demands.

Two proofs on one leaf are covered in the fire and security doors dual certification guide, and the columns the schedule needs are set out in the how to specify security doors guide. A leaf ordered with one proof when the room needs two arrives as a different door from the one the building needs.

The pane beside the leaf: sidelights, fanlights and the wall

The glass beside a fire door takes the same proof as the glass in the leaf, because a door that holds fire can still be reached through the pane beside it. A sidelight beside the leaf and a fanlight above it each take glass proved with the frame they sit in, and the report names each pane.

The windows that share the same wall take the same period as the doors beside them, because the fire moves to the weakest part of the wall. The fire rated windows guide covers those windows, and the fire rated sliding doors guide covers the leaves that close a wide opening another way.

A glazed screen beside a fire door is part of the same compartment wall, so the screen, the door and the wall are proved together, and a screen ordered without the door beside it may land on the wrong opening. The doors that hold smoke back while people move past them are covered in the smoke control doors guide.

One schedule for every glazed door: the pane on the order

Put the glazed door order together as one list, with a line for every door on the building and the pane, the bead, the glass and the fixings beside each one, so the door that arrives matches the door that was proved. A list that names one pane for the whole building leaves the fitter to guess which leaf takes which glass, and a guess is not a proof.

Check each line of the order against the list before it goes out, so no pane, bead or fixing is missed from the order. A bead or a fixing left off the order still has to be found, and cutting a pane into a leaf that is already hung takes longer than glazing the leaf before it leaves the factory. What each step up the scale adds to the price is worked through in the security door cost factors guide.

The round that looks after glazed doors walks the building in turn and looks at the pane, the bead, the fixings and the seals on each leaf. A crack in the pane, a bead that has come away from the leaf, or a seal painted over is noted beside the door it belongs to, so the repair is ordered before the pane fails. The checks a visit should cover are named in the fire door inspection checklist, and the doors that must hold both fire and forced entry are covered in the security door maintenance checklist.

Position Pane Period What to check
Stair core Small rectangular pane FD60 Pane, bead, seals
Corridor Rectangular pane FD30 Pane, bead, fixings
Classroom Rectangular pane FD30 Pane, bead, gap
Office floor Rectangular pane FD30 Pane, glass, closer
Plant room Small pane FD60 Pane, bead, seals

A vision panel is only as good as the pane, the bead and the proof behind it, so the glass, the fixings and the period belong on one line of the order.

What is a vision panel?

A glazed opening in a fire door leaf that lets people see through the door before they open it, proved with the leaf to EN 1634-1.

Does the pane hold fire as long as the leaf?

Yes, when the pane, the bead and the fixings went to the test with the leaf for the same period, FD30 or FD60.

How big can a vision panel be?

As big as the test evidence allows. A larger pane takes a different proof from a smaller one, so the size on the order is the size the test proved.

Can a vision panel sit on a security door?

Yes, where the glass takes the same grade as the leaf beside it, so the pane holds against the same attack as the door.

Who checks the panels?

The person who runs the building, on the round that looks at every door, and a crack or a loose bead is noted beside the door it belongs to.

Specifying glazed fire doors for a building?Send the door schedule and the pane each leaf must carry for a tested door quotation.
Get a free quote

Related

More in guides for specifiers

10 mistakes when specifying certified security doors 10 steps to specify an LPS 1175 door Acceptance and Snagging of a Security Door or Barrier Job Access Control Doors Acoustic Doors: Ratings and Specification After a Forced Entry Attempt: Checking a Security Door Airport Security Doors Anti-Ligature Doors for Mental Health Wards Anti-Ram Bollards Anti-ram gates and barriers: protecting vehicle entrances Arcade Security Doors Explained Automatic Doors Automatic Gates Cost Factors Automatic Vehicle Barriers Ballistic Panels Bank Security Doors Bingo Hall Security Doors Explained Blast doors: glazed vs solid and how they are rated Blast protection window film: what it does and what it cannot do Blast resistant windows: what drives the cost and how to specify them Bollard Cost Factors Explained Bollard regulations in the UK: spacing, height and depth Bookmaker Security Doors Explained Builders Merchant Security Doors Bullet Resistant Glass Cost Factors Bullet resistant glass ratings explained: BR1 to BR7 and SG classes Bullet resistant vs bulletproof glass: what the difference means Buying Security Doors and HVM Through Public Frameworks Car Park Security Doors Explained Car Showroom Security Doors Casino Security Doors Explained CDM 2015 Duties When Security Doors, Shutters or HVM Are Installed Cinema Security Doors Cleanroom Doors Cold Store Doors College Security Doors Commissioning, Handover and the O&M Manual for Security Doors and HVM Communal entrance doors for flats: Secured by Design and what to specify Community Centre Security Doors Control Room Doors Court Security Doors Crash Rated Fences and HVM Fencing Explained Data centre physical security: doors, glazing, HVM and shielding by zone Dental Practice Security Doors Depot Security Doors Explained Door Entry Systems Due Diligence When Selecting Vehicle Security Barriers Emergency Exit Doors EMP Shielding Cost Factors Explained Exhibition Centre Fire Door Rules Exhibition Centre Security Doors Factory Security Doors Faraday cage vs RF shielded room: what a business needs FB4 vs FB6 vs FB7: how to choose a ballistic rating Fire and security doors: how dual certification works Fire Compartmentation Fire Curtains Fire Door Certification Fire Door Closers Explained Fire Door Cost Factors Fire Door Duties of the Accountable Person Fire Door Gaps Fire Door Hardware Explained Fire door inspection checklist for steel and timber doors Fire Door Maintenance Fire Door Regulations Care Homes Fire Door Regulations for A and E Departments Fire Door Regulations for Airports Explained Fire Door Regulations for Bowls Clubs Fire door regulations for commercial buildings in the UK Fire Door Regulations for Dialysis Centres Fire Door Regulations for Hockey Clubs Fire Door Regulations for Hospitals Explained Fire Door Regulations for Offices Explained Fire Door Regulations for Operating Theatres Fire Door Regulations for Retail Explained Fire Door Regulations for Schools Explained Fire Door Regulations for Snooker Clubs Fire Door Regulations for Stadiums Fire Door Regulations for Student Accommodation Fire Door Regulations for Warehouses Fire Door Regulations Leisure Centres Fire Door Regulations Restaurants Fire Door Remediation Programme for Housing Providers Fire Door Rules for Badminton Clubs Fire Door Rules for Bingo Halls Fire Door Rules for Bookmakers Fire Door Rules for Bowling Alleys Fire Door Rules for Car Parks Fire Door Rules for Car Showrooms Fire Door Rules for Cinemas Fire Door Rules for Climbing Centres Fire Door Rules for Colleges Fire Door Rules for Community Centres Fire Door Rules for Cricket Clubs Fire Door Rules for Dental Practices Fire Door Rules for Depots Explained Fire Door Rules for Golf Clubs Fire Door Rules for GP Surgeries Fire Door Rules for Gyms Explained Fire Door Rules for Ice Rinks Fire Door Rules for Maternity Units Fire Door Rules for Mental Health Units Fire Door Rules for Museums Fire Door Rules for Oncology Units Fire Door Rules for Opticians Fire Door Rules for Pawnbrokers Fire Door Rules for Petrol Stations Fire Door Rules for Pharmacies Fire Door Rules for Ports Fire Door Rules for Post Offices Fire Door Rules for Prisons Fire Door Rules for Rehabilitation Centres Fire Door Rules for Self Storage Fire Door Rules for Shopping Centres Fire Door Rules for Squash Clubs Fire Door Rules for Supermarkets Fire Door Rules for Swimming Pools Fire Door Rules for Tennis Clubs Fire Door Rules for Theatres Fire Door Rules for UK Arcades Fire Door Rules for UK Casinos Fire Door Rules for UK Hospices Fire Door Rules for Walk-in Centres Fire Door Signage Fire Doors and Gateway 2 in Higher-Risk Buildings Fire Rated Glass Cost Explained Fire Rated Sliding Doors Explained Fire Rated Windows Cost Factors Fire Rated Windows Explained Fire Safety Enforcement Notices and Fire Doors: What the Responsible Person Must Do Flat Entrance Doors: PAS 24 and Fire Rated Forced Entry vs Ballistic vs Blast: Which Rating a Site Needs Garage Security Doors Explained Gate Automation Explained Golden Thread Records for Fire Doors GP Surgery Security Doors Explained Gym Security Doors Explained High Speed Doors HMO Fire Doors Hospice Security Doors Explained Hospital Security Doors: Wards, A&E, Plant Hospital Security Gates Hotel Fire Doors Hotel Security Doors How to choose HVM bollards: fixed, shallow mount, removable and automatic How to keep an LPS 1175 door rating valid after installation How to Specify Fire Doors in a Housing Tender How to specify security doors: a checklist for architects How to Verify a Secured by Design Listing How to Verify an LPS 1175 Certificate on Red Book Live How to Write an Operational Requirement for Physical Security HVM planters and street furniture: protection that blends in In-Service Care of Vehicle Security Barriers Installation Handover: LPS 1175 Doors and PAS 68 Barriers Intumescent Seals ISO 16933 explained: EXV and SB classes and hazard ratings ISO 22343 vehicle security barriers explained Keeping a Dual-Certified Fire and Security Door Valid in Service Laboratory Security Doors Layered Security for a Site: Deter, Detect, Delay, Mitigate, Respond Lead Times and Programme Risks for LPS 1175 Doors Leisure Centre Security Doors Library Security Doors Listed Building Fire Doors Loading Bay Doors Explained Lockdown and Access Control Hardware on an LPS 1175 Door LPS 1175 Gates and Grilles Explained LPS 1175 Issue 8 explained: from SR1 to SR8 to A1 to H20 LPS 1175 Roller Shutters LPS 1175 vs ASTM F2781 and Other US Ratings Explained LPS 1175 vs EN 1627: how UK and European burglar resistance ratings compare LPS 1175 vs PAS 24: which security standard does your door need? LPS 1175 Windows and Walling Explained Martyn’s Law and Places of Worship: What a Buyer Checks for Doors and Entry Control Martyn’s Law Enhanced Tier: Physical Measures and the Specifier Brief Martyn’s Law Standard Tier: Procedures, Doors and Shutters Martyn’s Law Timeline and the SIA Regulator Martyn’s Law: what premises must do and which physical measures to consider Master Key Systems MRI and RF shielded rooms: how they work and what to specify Museum Security Doors NPSA Catalogue of Security Equipment (CSE) Explained NPSA Forced Entry and Blast Guidance for Government Sites NPSA Guidance on Lockdown and Marauding Attack: What It Asks of Doors and Entrances Office Security Doors Optician Security Doors Explained Panic Hardware PAS 24 requirements for doors and windows explained PAS 68 Bollard Foundations Explained PAS 68 bollards: ratings, spacing and cost factors PAS 68 vs IWA 14 vs ISO 22343: hostile vehicle mitigation standards explained Pawnbroker Security Doors Explained Pedestrian Gates Petrol Station Security Doors Pharmacy Security Doors Planning Permission for Security Shutters, Gates and Bollards on Commercial Premises Plant room doors: fire, security and ventilation requirements Plant Room Fire Doors Port Security Doors Post Office Security Doors Explained Powder coating vs galvanising vs paint for steel Preliminary Market Engagement for Security Doors and HVM Prison Security Doors Programming a Security Door and Barrier Package on a Live Site Public-Sector Tender Response Checklist for Security Door and HVM Supply Reading a PAS 24 and SBD Door Test Report Regulation 38 Fire Safety Information at Handover for Fire-Rated Security Doorsets Replacing Security Doors in an Occupied Building Restaurant Security Doors Retail Security Doors Revolving Doors RF shielding standards and how shielded rooms are tested Rising Bollard Cost Factors Road Blocker Cost Factors Explained Road Blockers Explained Roller Shutter Cost Factors: What Drives the Price Roller shutter regulations in the UK: safety and maintenance Safe room and panic room doors: specification basics Safety Duties for Powered Doors, Gates and Barriers on Commercial Sites School Security Doors Sectional Doors Secured by Design explained: is it mandatory for doors? Secured by Design vs NPSA vs LPCB: Which One You Need Security Door Locks Security Door Maintenance Checklist Security Doors and Access for Everyone: What Approved Document M Asks Security Doors for A and E Departments Security Doors for Badminton Clubs Security Doors for Bowling Alleys Security Doors for Bowls Clubs Security Doors for Climbing Centres Security Doors for Cricket Clubs Security Doors for Dialysis Centres Security Doors for Golf Clubs Security Doors for Hockey Clubs Security Doors for Ice Rinks Security Doors for Maternity Units Security Doors for Mental Health Units Security Doors for Oncology Units Security Doors for Operating Theatres Security Doors for Rehabilitation Centres Security Doors for Snooker Clubs Security Doors for Squash Clubs Security Doors for Swimming Pools Security Doors for Tennis Clubs Security Doors for Walk-in Centres Security Doors West Midlands Explained Security Fencing Security Gates Cost Factors Explained Security shutters vs high performance roller doors Security shutters vs retractable grilles: which suits retail and commercial openings? Security Turnstiles Explained Security Window Film Security Windows for Schools Explained Self Storage Security Doors Server Room Doors Explained Shopping Centre Security Doors Smoke Control Doors Explained Smoke Curtains Specification Mistakes When Mixing LPS 1175, PAS 24 and SBD in One Tender SR2 vs SR3 vs SR4 security doors: choosing the right LPS 1175 level Stadium Security Doors Steel Door Frames Steel vs aluminium security doors: strength, ratings and looks Steel vs timber fire doors: which suits your building? Student Accommodation Security Doors Substation doors: security, ventilation and specification Supermarket Security Doors Telescopic Bollards Tender Evaluation Criteria and Scoring for Security Doors and HVM The Scope of a Maintenance Contract for Security Doors and Barriers Theatre Security Doors Thermal and Weather Performance of External Security Doorsets Thermally broken steel security doors: U-values and certification Traffic Calming as Hostile Vehicle Mitigation Transport hub security requirements Turnstile Cost Factors Explained Turnstile vs speed gate vs security portal: choosing entrance control Types of security doors for commercial buildings University Security Doors Explained Vehicle Dynamics Assessment: What It Tells the Buyer Before a Barrier Is Specified Warehouse Security Doors Explained Warehouse Security Gates Warranty, Defects Liability and Guarantees for Security Doors and Barriers What affects the cost of a bullet resistant door What affects the cost of a high-security door in the UK Window Security Bars View all →

Products

One supplier for the whole building envelope

Ready to specify your project?

Free assessment, written specification and test evidence. Reply within one working day.