An airport door works in two worlds at once. On one side it opens for passengers with bags and trolleys, on the other it guards the rooms and routes the public never sees. A door that fails on either side leaves the terminal open to the wrong person, or shuts the wrong person in.
The order starts with the terminal map, not with the leaf. A check-in hall that fills at dawn asks for a different door from a baggage hall where trolleys roll all day, and an airside door that only badged staff may open asks for a different lock from a door on a public concourse.
Every door in the terminal sits on one schedule, and an order that names each one plainly gets the right door on the right opening. The transport hubs sector page sets out the buildings these doors guard, and the transport hub security requirements guide covers the doors on the hub in full.
- LPS 1175 B3 / C5 / D10Forced entry ratings, three, five and ten minutes
- FD30 / FD60Fire resistance periods tested to EN 1634-1
- ISO 22343-1Vehicle security barrier ratings
- Martyn’s Law enhanced tierPremises holding 800 or more people
Terminals, baggage halls and airside: where an airport puts its doors
The public side of a terminal is check-in halls, departure lounges and arrivals, where doors open for crowds all day. The doors here must take constant use, trolleys and bags, and still shut on their own, because a door left open on a public concourse is a gap in the line.
Behind the public side sit the baggage halls, where trolleys and carts move goods between the terminal and the aircraft. The doors here are wider, the leaves heavier, and the hardware must take the knocks of the working day, so the hinge and the closer belong on the schedule beside the leaf.
Airside is the third world, the stands and service roads where only badged staff may go. A door onto airside must open for a pass the system knows and stay shut for the rest, and the fire door regulations for airports guide sets out the periods for the doors inside a terminal.
Public doors and restricted doors: the line between the two
Every door in a terminal sits on one side of a line. Public doors open for anyone in the building, while restricted doors open only for a pass, and the line between them is drawn on the plan before the order is placed, so no door is left to decide for itself.
The restricted side holds the baggage halls, the plant rooms, the server rooms and the corridors that lead airside. A door on this side takes a reader and a lock that records who passed, because the record matters as much as the leaf.
A door that straddles the line fails both sides. A public door with a reader nobody uses is a lock with no purpose, and a restricted door that stands open is a gap, so each door should be named public or restricted on the schedule.
Airside passes and access control: who opens which door
An airside pass is the credential that opens the doors beyond the public side. A card or a fob opens the door for the staff who hold it, and a pass that has been stopped must stop working everywhere at once, so one stopped pass cannot open a door at the far end of the terminal.
The credential is checked at the door, and the lock answers it. A pass that belongs to a member of staff who has left must be stopped on the system the same day, because a pass that still works is a door left open.
Contractors who work airside for a day take a pass that dies at the end of the shift. The pass should end on its own, without anyone having to remember to stop it, and the record should name the person, the door and the day the pass ended. The turnstiles at the staff entrance are covered in the security turnstiles guide, and the choice between a turnstile, a speed gate and a portal is worked through in the turnstile versus speed gate versus portal guide.
A pass that outlives the person who holds it opens a door it should not
A pass is given to a person for a job, and the pass should end when the job ends. A member of staff who leaves takes no pass with them, because a pass that still works after the person has gone opens every door it ever opened, and the terminal has no way of knowing who holds it. The pass list is checked against the staff list on a set day each month, and every pass that belongs to a person no longer on the staff list is stopped that day, not at the next review. The check is written down beside each pass, with the name, the doors it opened and the day it was stopped, so the record shows the pass ended when the person left.
A contractor takes a pass for the work in hand, and the pass carries the end date of that work on the record beside it. A pass for a project that runs for weeks is signed by a named sponsor, and the sponsor signs again each week the pass stays live, so no pass runs on past the week it was needed for. A pass that is lost is reported the same day it is missed, and it is stopped everywhere at once, because a lost pass that still opens one door at the far end of the terminal is a door left open. A pass found after it was stopped stays stopped, and the person takes a new pass, because the stopped pass may have been copied while it was lost. The transport hub security requirements guide sets out the doors on the hub in full, and the fire door regulations airports guide sets out the periods for the doors inside a terminal.
| Pass | Who holds it | When it ends |
|---|---|---|
| Staff pass | A member of staff | The day the person leaves |
| Contractor pass | A contractor on a named job | The end date on the record |
| Visitor pass | A visitor under escort | The end of the visit |
| Lost pass | No one | The day it is reported lost |
The night the terminal empties, the doors still work
The terminal empties at night, but the doors do not stop working. Cleaning crews and maintenance staff move through the building after the last flight, and the readers still record each door they open, so the night has a record as full as the day. A door propped open for a cleaning trolley is a gap no one sees, and the night round checks each leaf is shut and each closer has pulled it home before the crew moves on. A fire door that stands open at night leaves the compartment open with it, and the closer that pulls it shut is part of the proof the door carries. The Martyn’s Law guide for premises sets out what the law asks of a premises and when, and the vehicle line outside the terminal is proved to ISO 22343-1, with the ISO 22343 vehicle security barriers guide setting out the ratings in full.
The handover between the day staff and the night staff names each door that was checked and each fault that was found, so the morning starts from the night record and not from a guess. A fault found at night goes beside the door it belongs to before the shift ends, and the repair is ordered before the next sitting of the day. The bollards on the forecourt take the same care, and the anti-ram bollards guide covers the rated options for the line outside the terminal. Put the pass list and the door schedule on one enquiry, and the security door enquiry checklist lists what to send so each door is quoted with its pass and its release.
Fire and security on one leaf: the terminal door that must do both
Some terminal doors carry two proofs. The fire proof names the period the leaf holds back fire, and the forced entry proof names the minutes it holds back attack, and each proof must name the same leaf, frame and hardware, because a door proved for one job and not the other leaves one side of the terminal unguarded.
Fire periods in a terminal follow the risk behind each door. A door on a corridor takes FD30, a door on a compartment wall takes FD60, and a door that guards a smoke path takes FD30S, with the seal proved to BS EN 1634-3, to Sa for smoke at room temperature and S200 for smoke at 200 degrees Celsius.
The dual certification guide covers how fire and forced entry proofs share one doorset. A closer that pulls the leaf shut every time is part of both proofs, with no fire door taking less than EN 3 to BS EN 1154, and the fire door closers guide covers the sizes and the fitting, while the fire door hardware guide covers the grades and the parts behind a working fire door.
Each door needs its fail position set before the power goes
A terminal runs on power, and a power cut asks every door the same question at once. A public door on the concourse must open so the crowd can leave, while a door onto airside must stay shut so the restricted side stays restricted, and a fire door must shut on its own so the compartment stays closed. The answer for each door is set before the order goes out, because a door that has never been told what to do on power loss will do whatever its lock does by default. Power operated doors take the rule in EN 12453, and terminal doors take the periods the fire door regulations airports guide gives them. A door on the baggage hall takes the same care, because trolleys roll through it all day and the hardware must take the knocks.
A reader that has lost power answers no pass, so the key beside it matters. A door that guards airside takes a key override that only named staff hold, and the turnstile beside it takes the same care, because a staff entrance that cannot open strands the people who must keep the terminal running. The security turnstiles guide takes the turnstiles at the staff entrance, and the doors on the hub in full are taken up in the transport hub security requirements guide. A hold-open device to BS EN 1155 lets go when the power or the alarm calls it, so the doorset it holds swings shut on its closer, and the closer that pulls it home belongs to the proof the door carries.
| Door | On power loss | Why |
|---|---|---|
| Public entrance | Opens | The crowd must leave |
| Airside door | Stays shut | The restricted side stays shut |
| Fire door | Shuts on its closer | The compartment stays closed |
| Hold-open door | Released, then shuts | The alarm or the power lets it go |
The blackout test sits on the round, beside the closer check
The round that looks after the doors should cut the power to one door at a time and watch what it does. A door that should open is pushed from the public side, a door that should stay shut is tried from the restricted side, and a door that should shut is watched until its closer pulls it home. Each result goes on the schedule beside its door, with the date and the name of the person who ran the test, so the next round starts from the last test and not from a guess. The fire door inspection checklist gives each round its list, and what the law asks of a premises that holds a crowd is set out in the Martyn’s Law guide for premises.
A fault found on the test goes on the list the same day, with the door, the lock and the release named beside it, because a door whose fail position is wrong is a door that will fail the same way on the night it really goes. A door that fails the test stays on the list until the repair is done, and its opening is not left to a door that may not shut. Send the fail position of every door on the schedule. The security door enquiry checklist shows what the enquiry must hold, so each door is quoted with its power supply and its release.
The vehicle line outside the terminal: bollards, barriers and the forecourt
The forecourt is where vehicles reach the terminal, and the line outside it decides what may pass. Bollards, barriers and gates stand between the road and the frontage, so a vehicle that will not stop meets steel before it meets glass.
Vehicle ratings are proved to ISO 22343-1, which supersedes PAS 68:2013, with test vehicles from a 1,500 kg car to a 30,000 kg truck at 48, 64 or 80 km/h. The rating on the order should match the vehicle the approach could bring, and the ISO 22343 vehicle security barriers guide sets out the ratings in full.
ProtectUK sets the spacing on the line, with no more than 1,200 mm clear between bollards and a minimum height of 500 mm. The hostile vehicle mitigation page covers the line in full, and the anti-ram gates and barriers guide covers the rated options for the gate line.
Blast on the frontage: glass, frame and the stand-off
A terminal frontage faces the road, so the glass on it must be proved for the blast it could face. Windows are proved to ISO 16933, with EXV for a charge carried in a vehicle at a stand-off distance and SB for a hand-carried charge at the face, and the class on the order should match the threat the frontage faces.
The frame carries the rating as much as the glass does, because a blast that passes the pane still meets the frame. The frame, the beads and the fixings belong on the same line as the glass, so the window that arrives is the window that was tested.
The ratings in full are set out on the blast ratings page, and the windows that carry the rating are covered in the blast resistant windows guide. The vehicle ratings that guard the same frontage are set out on the vehicle impact ratings page, and the two proofs must stay on separate lines, because one test report cannot prove both.
Martyn’s Law and the crowded terminal: the enhanced tier
A terminal holds crowds, so it sits in the enhanced tier of Martyn’s Law, which covers premises that hold 800 or more people at a time. The law was given Royal Assent in April 2025, with go-live expected in spring 2027, and it asks the largest premises to plan for a terror attack and to keep the plan in practice.
Doors play their part in that plan. Escape routes must open when the alarm sounds, with no key, no card and no code standing between the crowd and the street, and the doors on those routes must release at once, for everyone in the building, including a passenger who has never seen the terminal before.
The Martyn’s Law guide for premises sets out what the law asks of a premises and when. The doors that serve the escape routes are covered in the smoke control doors guide, which covers the doors that must hold smoke back while people move past them.
One schedule for the whole airport: every door on one line
Write the enquiry as one schedule with a line for every door in the terminal, and put the position, the fire period, the forced entry rating, the glazing and the hardware on each line, so the door that arrives is the door that was proved.
Check each quote against the schedule before the order is placed, because a quote that leaves a closer or a seal off the list will cost the same part later, fitted round a door that is already in use. The security door cost factors guide sets out what each step up the scale adds to the build, and the how to specify security doors guide sets out the columns the schedule needs.
File the test reports and the inspection routine with the doors when they arrive, so the record covers the whole life of every door in the terminal. The fire door inspection checklist names what each round should look for, and the keeping an LPS 1175 rating valid guide sets out what breaks a rating.
| Position | Door | Rating | What to check |
|---|---|---|---|
| Check-in hall | Glazed security door | LPS 1175 B3 | Glass, frame, closer |
| Baggage hall | Solid security door | LPS 1175 C5 | Lock, hinges, closer |
| Airside door | Fire and security door | FD30 + B3 | Seals, reader, release |
| Escape route | Fire door | FD30S | Seals, closer, release |
| Plant room | Fire door | FD60 | Seals, closer, latch |
Terminals, baggage halls and airside each ask a different door, so the rating, the credential and the release must all sit on the same schedule.
What rating do airport security doors need?
The opening decides. Forced entry is proved to LPS 1175, with B3, C5 and D10 naming three, five and ten minutes, and fire is proved to EN 1634-1, with FD30 or FD60 naming the period.
Who may open an airside door?
Only a person who holds a pass the system knows. A pass that has been stopped must stop working everywhere at once, and a door onto airside must stay shut for anyone without one.
Do terminal doors need a fire rating?
Where the door sits on an escape route or a compartment wall, yes. Fire is proved to EN 1634-1 with the frame and the fixings, and the period follows the fire load behind the door.
What guards the forecourt outside the terminal?
Bollards, barriers and gates, proved to ISO 22343-1, with no more than 1,200 mm clear between bollards and a minimum height of 500 mm.
Who checks airport security doors?
The terminal team, on the routine the fire risk assessment sets. Every round covers the closers, the seals, the locks and the readers, and every fault found is written on the record the same day.