Fire curtains for wide openings that cannot take a fire door: the fabric, the drop, the period to EN 1634-1 and the curtain on the order for the whole building.
- ✓Third-party test evidence with every product
- ✓Written specification you can issue to tender
- ✓Supplied and installed across the UK
Get a free project quote
Rating, written specification and budget range within one working day.
Confidential. No cost, no obligation.
Third-party tested
Evidence with every quote
UK manufactured
Made to your sizes
One accountable team
Specify, supply, install
Confidential handling
Details never shared
A wide opening cannot take a fire door. A shop front, an atrium and the gap between two parts of a warehouse may be too wide for a leaf, or the opening must stay clear through the day for trolleys, forklifts and people. A fire curtain hangs above the opening and waits, and when the alarm sounds it drops and closes the gap the door cannot close.
The curtain is not a door that hangs in a different shape. It has no leaf, no hinges and no handle. The fabric that drops must hold fire back for its period, the guides at each side must hold the fabric in place while it drops, and the release that lets it fall must work when the power fails.
The doors that guard the smaller openings are set out in the fire door regulations commercial buildings guide, and the smoke control doors guide covers the doors that hold smoke back. A curtain ordered without the fire strategy it belongs to may land in the wrong opening. The curtain, the opening and the period are named together on one line of the order.
- E / EW / EI 30-120Fire resistance to EN 1634-1
- Gravity dropThe curtain that falls without power
- EN 12101-1Smoke curtains hold smoke back
- One scheduleEvery curtain on one line
The opening that cannot take a door: what a fire curtain must do
A fire curtain stands above the opening it guards, rolled up in a box, and it is out of sight while the building is in use. The opening below it stays clear for people, trolleys and forklifts, and nothing hangs in the way. When the alarm sounds, the curtain drops from its box and closes the opening from the top to the floor.
The curtain must close the whole opening, edge to edge. A gap at the side lets fire through beside the fabric, and a curtain that stops short of the floor leaves the fire a way under it. The fire rated sliding doors guide covers the doors that close a wide opening another way.
Wide openings take curtains because no leaf can span them. An atrium, a warehouse bay and a shop front each hold an opening wider than any doorset. The opening decides the curtain, so the width, the height and the way the opening is used belong on the order beside the curtain. The types of security doors guide works through the doors that guard each part of a building.
The fabric that holds fire back: how a curtain is proved
The fabric of a fire curtain is proved against fire, not against forced entry. The test heats the fabric as a fire would, and the fabric must hold the flames back for its period without letting flame through. A fabric that holds for 30 minutes carries a different proof from one that holds for 60, and the period on the order is the period the test proved. The fire rated windows guide covers the windows that share the same wall.
Fire resistance is measured in E, EW and EI from 30 to 120 minutes under EN 1634-1, and the letters beside the number say what the curtain held back. E holds the flames back, EW holds the flames and some of the heat, and EI holds the flames and the heat. The letters belong on the order beside the period.
The curtain, the guides and the box were proved together, and the proof covers the curtain as one. A fabric swapped for another after the test leaves the curtain different from the one tested, and a curtain that differs from the test has no proof. The fire rated glass cost guide works through what each step up the scale adds to the price.
The drop that closes the opening: gravity, motors and the release
A fire curtain drops by gravity, because the release that lets it fall must work when the power fails. The curtain is held up by a motor or a magnet, and when the alarm sounds the hold lets go and the weight of the bottom bar pulls the fabric down. A curtain that needs power to drop is no curtain at all in a blackout, so the drop is tested on the round.
The speed of the drop matters as much as the drop itself. A curtain that falls too fast can hurt a person under it, and a curtain that falls too slowly leaves the opening open while the fire spreads. The drop is set on site, with a brake that slows the fall to the speed the order names.
The release must answer the alarm, and the alarm must reach the curtain. A curtain wired to the fire alarm drops when the alarm sounds. The wiring, the detector and the release belong on the order beside the curtain, because a curtain that never hears the alarm never drops. The fire rated roller shutters page covers the shutters that drop over a shop front, and a curtain drops over an opening the same way, without the steel leaf.
The period on the curtain: 30, 60 and the letters beside them
The period on a curtain follows the fire load behind the opening, not the size of the opening. A curtain that guards a store takes the period the fire load behind it demands, while a curtain on a stair core takes the period the escape route needs, and the period on each curtain matches the opening it guards. The fire door regulations warehouses guide sets out the periods for the shared parts of a warehouse.
Matching the period starts on the schedule, where the curtain is named beside the opening it closes. A curtain proved for 30 minutes on an opening that must hold 60 runs out before the wall beside it does, because the curtain and the wall were never proved together for the longer period. The fabric, the guides and the box were proved together, and the period on the order is the period all three were tested to.
Curtains on escape routes: the way out must stay clear
A curtain on an escape route must not block the way out. People on the route must get out without a key, whatever the curtain says, because the way out matters more than the way in. A curtain that drops across the only way out traps the people behind it, so an escape route takes a curtain that leaves a way through, or no curtain at all.
Where a curtain must sit on an escape route, it drops in stages or leaves a gap at the side, so people can pass while the fire is held back. The staged drop is set on site, and the gap beside the curtain is marked on the floor.
Doors on the same route take panic bars to BS EN 1125, and the bar must work with the lock beside it, not against it, so the leaf opens for a crowd even when the power has gone. The fire door hardware guide covers the hardware beside the leaf, and the curtain beside the door is tested the same way on the round.
The drop lands on whatever is stored under the curtain
A fire curtain hangs in a box above the opening, out of sight, and the floor below it looks like free space. A pallet is parked under it, a display unit is pushed against it, or a cleaning trolley is left there at the end of the day, and each one sits in the path of the drop. The bottom bar must reach the floor for the opening to close, and a bar that lands on a pallet stops short of the floor, so the fire passes under the fabric while it hangs above it. A drop that cannot reach the floor holds nothing, whatever period its test report names, because the period was proved with the opening clear.
The floor below the box takes a marked line, and the line is kept clear every day, not only on the round. The line is painted or taped on the floor, and the people who work beside the opening are told what it means, so a pallet is never parked across it and a display is never pushed onto it. Warehouse shared parts get their periods from the fire door regulations warehouses guide, and doors that keep smoke back as people move past are taken up in the smoke control doors guide. Fabric, guides and box were tested as one, so the order carries the period the three were proved to under EN 1634-1.
| What is stored | What it does to the drop | What to do |
|---|---|---|
| Pallet | Bottom bar stops short | Move it off the line |
| Display unit | Fabric catches and tears | Push it clear of the opening |
| Trolley | Bar lands on the handle | Park it away from the line |
| Cleaning kit | Guides blocked at the floor | Store it off the line |
What has crept back under the opening moves off the line on the round
The round that looks after the curtains walks the line under each one and looks at the floor before it looks at the fabric. A pallet that has crept back onto the line is moved the same day, and the move is written beside the opening it belongs to, so the next round starts from a clear floor and not from a guess. The guides are looked at where they meet the floor, because dust and goods at the foot of the guides can slow the drop, and the bottom bar is wiped down before the round ends, so nothing stuck to it slows the next drop. The fire door inspection checklist gives each visit its list, and sliding doors that close a wide opening a different way are taken up in the fire rated sliding doors guide. Where the opening beside the drop takes a door with two proofs, the dual certification guide sets out how two proofs share one leaf.
A curtain that can reach the floor holds the opening it guards, and the round that keeps the floor clear is the round that keeps the proof. Shutters that drop over a shop front are taken up on the fire rated roller shutters page, and a shutter that lands on goods stored under it fails the same way, so the line on the floor belongs under every closure that drops.
Smoke beside the fire: the curtain that holds smoke too
Smoke reaches people before the flames do, so a curtain that holds fire and lets smoke through holds only half the line. A fire curtain holds the flames back, and a smoke curtain holds the smoke back. Smoke curtains are proved to EN 12101-1 for smoke containment, while fire curtains hold fire back to EN 1634-1.
An opening that needs both takes a curtain proved for both, or two curtains side by side. The smoke seal on a fire door is proved to BS EN 1634-3, to Sa for smoke at room temperature and S200 for smoke at 200 degrees Celsius, and the curtain takes the same idea: the edge of the fabric must meet the guides and the floor without a gap the smoke can slip through. What each step up the scale adds to the price is set out in the security door cost factors guide.
The smoke control doors guide covers the doors that hold smoke back while people move past them, and the curtain on the same line is checked the same way on the round.
The curtain beside the doors: one fire strategy, one schedule
Curtains and doors share the fire strategy, so they share the schedule. A wall where the door carries FD60 and the opening beside it carries a curtain proved for 30 minutes is a wall with a hole in it, because the fire moves to the weakest part. The curtain and the door beside it should carry the same period. The keeping an LPS 1175 rating valid guide sets out what breaks a rating once a door is fitted.
The fire strategy names every opening in the wall, with the door or the curtain beside each one. The fire and security doors dual certification guide works through how two proofs share one leaf, and the curtain beside the leaf takes the same line on the schedule: the opening, the closure and the period, all on one row.
A curtain ordered without the doors beside it may land in the wrong opening, so the curtain, the door and the period are named together. The steel versus timber fire doors guide works through the choice between leaf materials, and the curtain that guards the opening beside those leaves takes its period from the same fire load.
A curtain that drops once a year on test proves it will drop on the night it matters
A fire curtain spends its life rolled up in a box, out of sight, and the only proof it will drop is the drop it has already made. The test drops the curtain on the round, and the fabric, the guides and the release are looked at as it falls, because a curtain that has never dropped may not drop when the alarm sounds. The bottom bar must reach the floor, the fabric must sit in the guides on both sides, and the release must let go the moment the alarm calls it. The fire door inspection checklist states what each visit should cover, and the fire rated sliding doors guide takes the doors that close a wide opening another way.
The test is written down beside the opening it belongs to, with the date, the drop and each fault found. A curtain that drops too fast is reset before the round ends, because a curtain that falls too fast can hurt a person under it, and a curtain that drops too slowly is reset too, because a slow drop leaves the opening open while the fire spreads. A curtain that fails the test stays down until it is repaired, and the opening it guards is not left to a curtain that may not drop. The person who runs the building keeps the test record with the curtain, so the next round starts from the last drop and not from a guess.
| Test | What is looked at | What a fail means |
|---|---|---|
| Drop | Bottom bar reaches the floor | Curtain stays down until repaired |
| Guides | Fabric sits in both guides | Fabric may leave the line |
| Fabric | Tears, creases, wear | Fire may pass the fabric |
| Release | Lets go on the alarm | Curtain may never drop |
The opening that changes its use takes a curtain proved for the new use
An opening changes its use as the building changes. A store becomes a workshop, a shop front becomes a store room, and the fire load behind the opening changes with it, so the period the opening must hold changes too. A curtain proved for the old use may not hold the new one, because the period follows the fire load behind the opening, not the size of the opening. The fire door regulations warehouses guide lists the periods the shared parts of a warehouse need, and the smoke control doors guide takes the doors that hold smoke back while people move past them. The new use is written on the schedule beside the opening, with the period the new fire load demands, so the curtain that arrives matches the opening it guards.
The opening, the use and the period are named together on the schedule, and the next round checks the curtain against the use the opening carries now, not the use it carried when it was fitted. A curtain that no longer matches its opening goes beside that opening on the same day, and the dual certification guide shows how two proofs sit on one leaf, while the fire rated roller shutters page takes the shutters that drop over a shop front.
One schedule for the whole building: every curtain on one line
Put the curtain order together as one list, with a line for every opening on the building and the curtain, the period and the release beside each one, so the curtain that arrives matches the curtain that was proved. A schedule that names one curtain for the whole building leaves the fitter to guess which opening takes which fabric, and a guess is not a proof.
Read the quotation beside the schedule before the order goes out, and mark each curtain, guide and release as it is priced. A curtain left off the price still has to be bought, and fitting it to an opening that is already in use costs more than ordering it with the building. The how to specify security doors guide sets out the columns the schedule needs, and the fire door closers guide sets out the sizes and the fitting of closers.
The round that looks after fire curtains walks the building in turn and looks at the fabric, the guides, the box and the release. Each fault is written against the opening it belongs to on the same day, so the repair follows the fault and the opening never stands open. The fire door inspection checklist names what each visit should look for, and the security door maintenance checklist covers the doors that must hold both fire and forced entry.
| Position | Curtain | Period | What to check |
|---|---|---|---|
| Atrium | Fire curtain | EI 60 | Fabric, guides, drop |
| Warehouse bay | Fire curtain | EI 60 | Fabric, guides, release |
| Shop front | Fire curtain | EI 30 | Fabric, guides, bottom bar |
| Corridor | Smoke curtain | EN 12101-1 | Fabric, guides, drop |
| Stair core | Fire curtain | EI 60 | Release, guides, gap |
A curtain holds only as long as the fabric, the guides and the proof behind it, so the period, the release and the drop must all sit on the same schedule.
What is a fire curtain?
A fabric closure that drops from a box above a wide opening when the alarm sounds, holding fire back for its period.
How long does a fire curtain hold fire back?
From 30 to 120 minutes to EN 1634-1, in E, EW and EI. The letters beside the number say what the curtain held back.
What is the difference between a fire curtain and a smoke curtain?
A fire curtain holds fire back to EN 1634-1. A smoke curtain holds smoke back to EN 12101-1.
Can a fire curtain sit on an escape route?
Only where the way out stays clear, with a staged drop or a gap beside the curtain so people can pass.
Who checks the curtains?
The person who runs the building, on the round that walks every opening. Each fault is written against the opening it belongs to on the same day it is found.