ArxBridge
Automatic Doors
Automatic doors for shops, offices and hospitals: sliding and swing operators, safety sensors to EN 12453 and the leaf on fire and escape routes.
- ✓Third-party test evidence with every product
- ✓Written specification you can issue to tender
- ✓Supplied and installed across the UK
Get a free project quote
Rating, written specification and budget range within one working day.
Confidential. No cost, no obligation.
Third-party tested
Evidence with every quote
UK manufactured
Made to your sizes
One accountable team
Specify, supply, install
Confidential handling
Details never shared
An automatic door opens itself when a person reaches it, and shuts itself behind them when they have passed. The operator above the leaf, the sensors that watch the opening and the leaf itself work as one door, so people pass without a hand on the leaf.
The door must open for everyone who should pass and shut behind them, and it must stop when a person stands in its path. The operator, the sensors and the leaf belong on the same line of the order, because the door that arrives must be the door that was proved.
The operators that move a gate leaf are set out in the gate automation guide, and the closer that pulls a manual leaf shut is covered in the fire door closers guide. The types of security doors guide works through the doors that guard each part of a building, so the operator, the sensors and the leaf are named together.
- EN 12453Safety in use of power operated doors
- Sliding or swingThe operator that fits the opening
- Sensors stop the leafPhotocells, edges and loops
- Fail safeThe door when the power goes
The operator, the sensors and the leaf: what an automatic door is made of
An automatic door is three parts that must agree with each other. The operator drives the leaf, the sensors watch the opening, and the leaf itself carries the weight, the glass and the finish. A leaf that is too heavy for its operator moves slowly and wears the drive, while an operator that is too strong for its leaf slams the leaf against its stops.
The sensor is the part that decides when the leaf moves. A radar sensor above the opening watches the approach and opens the leaf before the person reaches it, a photocell beam across the opening holds the leaf open while a person stands in it, and a safety edge on the leaf stops the leaf when it meets resistance.
The leaf must suit the traffic through the opening. A shop entrance takes a leaf with glass that lets people see through before the leaf opens, an office lobby takes a leaf that matches the doors beside it, and a hospital corridor takes a leaf wide enough for a bed to pass.
How many times a day the leaf must open: matching the drive to the traffic
An automatic door is sold on its drive, and the drive is sold on its duty. A shop entrance opens for every customer through the day, an office lobby peaks in the morning and again in the evening, and a hospital corridor takes a steady stream from morning to night. The count of openings a day decides the drive, because a drive built for light use on a shop front wears early and leaves the leaf slow, noisy and short of its opening.
Ask for the duty in cycles and put the number on the order beside the traffic the entrance must take. A drive that runs all day needs a motor and a gearbox built for that count, and it needs a service interval that matches the count as well, because the rollers, the belt and the sensors wear with every opening. The fire door closers guide covers the closer that pulls a manual leaf shut when no operator drives it. A door that opens a few times an hour takes a lighter drive, and the order should say so, so the entrance does not pay for a drive it never uses.
The hold-open time belongs on the same line as the duty. A leaf that stays open too long lets the heat out of the entrance all day, and a leaf that shuts too soon catches the slow walker halfway through. The security turnstiles guide covers the lane beside the door, where the stream of people is counted before it reaches the leaf, and the revolving doors guide covers the drum that takes the same stream without ever standing open.
Radar opens for everyone, a pad opens for one press, a reader opens for the list
The leaf opens when it is called, and the call decides who passes. A radar sensor above the opening watches the approach and opens the leaf for anyone who walks towards it, so it suits a shop or a public entrance where everyone who reaches the door should pass. A radar sensor suits no door that must stay shut, because it cannot tell a customer from a passer-by.
A push pad calls the leaf only when a person presses it, so it suits a door on a route where the leaf should stay shut until it is wanted, and a pad set at wheelchair height lets a person in a wheelchair call the leaf from where they sit. The force to open a door on the route must stay below 30 N for the first 30 degrees of travel and below 22.5 N beyond, under BS 8300 and Approved Document M, and the pad must sit where a person in a wheelchair can reach it.
A card reader ties the leaf to the access control, so the door opens only for the card holders on the list and the record shows who passed and when. A staff door takes a reader, a public entrance takes radar, and a hospital corridor takes radar with a push pad beside it, so the leaf opens for the bed as readily as for the person on foot. The fire rated sliding doors guide covers the sliding leaves that must also hold fire back, and the security door maintenance checklist sets out the round that keeps the sensors, the operator and the release working. The steel door frames guide covers the frame the leaf hangs in and the fixings that hold it. Send the entrance schedule and the traffic each opening must take, and we will send a tested door price back within one working day.
| Call | Who it opens for | Entrance it suits |
|---|---|---|
| Radar | Anyone who approaches | Shop or public entrance |
| Push pad | Whoever presses it | Controlled route, wheelchair height |
| Card reader | Card holders on the list | Staff door, recorded entry |
| Radar and pad | Approach or press | Hospital corridor, beds and feet |
Sliding doors: the leaf that moves along the wall
A sliding door moves its leaf along the wall beside the opening, so the floor in front of the door stays clear. The leaf runs on a track above the opening, and the operator pulls the leaf along the track when the sensor calls for it. A sliding leaf suits an entrance where people walk straight through.
The track must be level and the rollers must run true, because a leaf that drags on its track wears the operator and stops short of the opening. The track, the rollers and the operator belong on the order beside the leaf, so the leaf that arrives covers the opening it was ordered for.
Two sliding leaves can meet in the middle of a wide opening, and each leaf takes its own operator or shares one drive. A wide shop front takes a pair of leaves that part to either side, and the opening between them must be wide enough for the traffic the shop expects.
Swing doors: the leaf that opens on its hinges
A swing door opens its leaf on hinges, like a manual door, and the operator drives the leaf through its arc. The operator sits above the leaf or in the floor below it, and it pushes the leaf open when the sensor calls and pulls it shut when the opening clears. A swing leaf suits an opening where the wall beside it cannot carry a track, because the leaf needs only its hinges and its frame.
The arc of a swing leaf must be clear, because the leaf sweeps across the floor as it opens. A mat, a bin or a queue of people in the arc will meet the leaf, so the safety sensors must watch the arc as well as the opening.
A swing leaf can open in one direction or both, and the direction belongs on the order beside the leaf. A leaf that opens outwards meets the street, while a leaf that opens inwards meets the lobby, and the side the leaf swings to decides where the sensors sit.
Safety in use: EN 12453 and the sensors that stop the leaf
Safety in use of a power operated door is proved to EN 12453, which sets out how a door must behave when a person or a vehicle is in its path. Photocells watch the line the leaf travels, safety edges stop the leaf when they meet resistance, and loops in the ground hold the door open while a vehicle waits. Each device belongs on the order beside the operator, because a door without them is a door that can hurt someone.
The sensors must be tested by breaking the beam and watching the leaf stop, and the test is run on every visit, not only when the door is first fitted. A photocell that has been knocked out of line watches the wrong place, and a safety edge that has hardened with age stops the leaf too late. The security door maintenance checklist names the checks that keep a doorset honest through its life, and the sensors on an automatic door belong on the same round.
| Position | Door | Operator | What to check |
|---|---|---|---|
| Shop entrance | Sliding leaf | Track drive | Track, rollers, sensors |
| Office lobby | Swing leaf | Overhead drive | Hinges, arc, sensors |
| Hospital corridor | Sliding leaf | Track drive | Width, sensors, release |
| Back of house | Swing leaf | Floor drive | Hinges, closer, lock |
| Escape route | Swing leaf | Manual release | Release, hinges, gap |
If the sensor stops seeing people, the door must still let them through
An automatic entrance earns its keep by opening for everyone who reaches it, and the sensor is the part that decides. Dust on the sensor face, a bracket knocked out of line by a trolley, or a cable worked loose by years of vibration can each leave the sensor blind, and a blind sensor leaves the entrance shut to the very people it was fitted to admit.
Test the sensor from the approach, not from beside the frame. Walk towards the opening at the pace a visitor would use, from each side, and watch whether the doorset answers before you reach it. A sensor that answers late, or only when you stand close to the frame, is already failing, and the fault is written on the record the same day. The maintenance checklist gives the round in order: sensors first, then the operator, then the release.
Keep a spare sensor of the same type on the shelf, with the bracket and the fixing beside it. A sensor changed on the day it fails costs the building an hour; a sensor ordered after it fails costs the building a week of a shut entrance. The revolving doors guide deals with the drum that takes the same stream of people without ever standing open, and the door entry systems guide deals with the readers that call the doorset for card holders only.
With the power off, the release is the only way through
Every automatic entrance needs a way through when the power goes. The manual release is that way, and it must work by hand, without a key and without force beyond what a person on the route can manage. A release that needs two hands and a shoulder is no release at all, and it will be found out on the night the lights go out, not on the day it was fitted.
Test the release with the power off, not on. Cut the supply, work the release, and push the doorset open by hand from each side, then restore the power and check that the operator takes up the drive again without a fault. The test belongs on the record beside the sensor test, because a release that has seized through months of disuse is as useless as a sensor that has gone blind. Approved Document M and BS 8300 set the limit on the opening force. For the first 30 degrees of travel it stays below 30 N, and beyond that it stays below 22.5 N.
Where the entrance sits on a fire route, the release is part of the escape, not an extra. The doorset must open when the alarm calls it, and the release must still work if the alarm has cut the power. The fire door closers guide deals with the closer that pulls a manual doorset shut when no operator drives it, and the steel door frames guide deals with the frame the doorset hangs in. Send the entrance schedule with the traffic each opening must take, and the enquiry checklist sets out what to send for each opening.
| Fault | How it shows | What to do |
|---|---|---|
| Sensor blind | Doorset stays shut as people approach | Clean the face, check the bracket |
| Sensor late | Answers only at close range | Record it, change the sensor |
| Release seized | Will not move by hand with power off | Free it, test it, record the test |
| Operator will not take up | Fault after power is restored | Call the service visit forward |
The push that opens the leaf: BS 8300 and Approved Document M
A person who cannot use the sensor must still get through the door, because the entrance belongs to everyone who reaches it. The force to open a door on the route must stay below 30 N for the first 30 degrees of travel and below 22.5 N beyond, under BS 8300 and Approved Document M.
The manual release beside the leaf must work without power, because the way out matters more than the way in. A leaf that needs power to open is no leaf at all in a blackout, so the release is tested by hand on every visit, with the leaf watched as it opens and shuts. The fire door closers guide sets out the sizes and the fitting of closers, and the leaf that must shut on its own takes a closer that pulls it home every time.
Controls must sit where a person in a wheelchair can reach them, and the panel that calls the leaf must be clear enough to read in the light the entrance actually gets.
Automatic doors on fire and escape routes: the leaf that must still open
A door on an escape route must open when the alarm sounds. The leaf on such a route releases from its operator when the alarm sounds, so the person behind it can push the leaf open with one action. A leaf that stays locked to its operator traps the people behind it.
The leaf on a fire route must also hold fire back for its period, and the operator must not break the proof of the leaf. A fire rated leaf takes an operator that was proved with it, because the leaf, the frame and the operator were proved together, and an operator swapped for another after the test leaves the door different from the one tested. The fire door regulations commercial buildings guide sets out the periods for the shared parts of a public building, and the smoke control doors guide covers the doors that hold smoke back while people move past them.
Hold-open devices that keep a fire leaf open through the day must release the moment the alarm sounds, proved to BS EN 1155, and the release belongs on the schedule beside the door. The fire rated sliding doors guide covers the sliding leaves that must also hold fire back.
Where automatic doors belong: shops, offices and hospitals
Shops take automatic doors at the front, where the stream of customers never stops. A shop entrance takes a sliding leaf with glass, so customers can see through before the leaf opens, and the operator takes the cycle count of the shop, because a leaf that opens for every customer through the day needs a drive rated for that cycle. The fire door regulations retail guide sets out the periods for the shared parts of a shop, and the security turnstiles guide covers the lobby line beside the doors.
Offices take automatic doors at the lobby, where staff, visitors and deliveries all pass through one entrance. An office lobby takes a swing leaf where the wall beside the opening cannot carry a track, and the leaf must open for a person carrying a box as readily as for a person carrying nothing. The fire door regulations offices guide sets out the periods for the shared parts of an office.
Hospitals take automatic doors on the corridors, where beds, trolleys and wheelchairs pass through the day. A hospital corridor takes a leaf wide enough for a bed, and the leaf must shut behind the bed without catching the trolley behind it. The hospital security doors guide works through the doors on a site where staff, patients and visitors all need a different way in.
One schedule for the whole entrance: every operator on one line
Put the automatic door order together as one list, with a line for every entrance on the building and the leaf, the operator, the sensors and the fail position beside each one, so the door that arrives matches the door that was proved. A schedule that names one operator for the whole building leaves the fitter to guess which entrance takes which drive, and a drive fitted to the wrong leaf opens the wrong door.
Check every line of each quotation against the schedule before the order goes out, so no operator, sensor or release is left off the price. Anything left off the quotation still has to be bought. The how to specify security doors guide sets out the columns the schedule needs, and the security door cost factors guide works through what each step up the scale adds to the price.
The round that looks after automatic doors walks every entrance in turn and tests the sensor, the operator and the release on each one. Each fault is written against the door it belongs to on the same day, so the repair follows the fault and the entrance never stands open. The fire door inspection checklist names what each visit should look for, and the automatic door that guards the entrance belongs on the same round.
An automatic door holds only as long as the operator, the sensors and the leaf behind it, so the drive, the safety devices and the fail position must all sit on the same schedule.
What is an automatic door?
A leaf with an operator and sensors that open the leaf when a person reaches it and shut it behind them, with a manual release beside the leaf.
Sliding or swing?
Sliding where the wall beside the opening can carry a track and the floor must stay clear, swing where the leaf must open on its hinges.
What stops the leaf hurting someone?
Sensors proved to EN 12453: photocells watch the opening, safety edges stop the leaf on contact, and loops hold the leaf open while a vehicle waits.
Can an automatic door sit on an escape route?
Yes, where the leaf releases from its operator when the alarm sounds, so the leaf opens with one push and no power.
Who checks the doors?
The person who runs the building, on the round that walks every entrance. The record lives with the building file.
If this is one of several openings on the site, the enquiry checklist shows the rating, hardware and evidence to name for each.
Get a free quote
Related
More in guides for specifiers
Products
One supplier for the whole building envelope
Ready to specify your project?
Free assessment, written specification and test evidence. Reply within one working day.