Emergency exit doors for crowded buildings: panic bars to BS EN 1125, opening force, fire and escape on one leaf, and the schedule for the whole escape route.
- ✓Third-party test evidence with every product
- ✓Written specification you can issue to tender
- ✓Supplied and installed across the UK
Get a free project quote
Rating, written specification and budget range within one working day.
Confidential. No cost, no obligation.
Third-party tested
Evidence with every quote
UK manufactured
Made to your sizes
One accountable team
Specify, supply, install
Confidential handling
Details never shared
An emergency exit door is the door a crowd pushes through when the alarm sounds. In a hall, a school or a hospital, the people behind the leaf may not know the building, and the door is the last thing between them and the way out. The leaf must open with one push, without a key, a code or a card, and it must open every time.
The door that guards an escape route has two jobs that pull in opposite directions. It must hold fire and smoke back while people move past it, and it must let a crowd through in seconds when the alarm sounds. A door that holds fire but traps people has failed, and a door that opens easily but lets smoke through has failed too. The types of security doors guide works through the doors that guard each part of a building.
The hardware that releases the leaf is set out in the fire door hardware guide, and the fire door closers guide covers the closer that shuts the leaf behind the crowd. The leaf, the frame, the bar and the closer belong on the same line of the order, because the proof covers the doorset as one.
- BS EN 1125Panic bar proved for crowds
- 30 N / 22.5 NOpening force to BS 8300
- 60% of the leafMinimum panic bar width
- FD30 / FD60Fire periods to EN 1634-1
The door that opens when a crowd pushes: what an exit door must do
An exit door opens outwards, towards the way out, because a crowd pushing against a leaf that opens inwards will hold it shut. The leaf swings in the direction people run, and the hinges, the frame and the fixings must carry the weight of the crowd behind it.
One action must open the door. A push on the bar throws the latch and the leaf swings open, and no second action is needed.
The door must also shut behind the crowd, because an exit door left standing open lets smoke through the gap it guards. A closer to BS EN 1154 pulls the leaf shut after each person, and the closer belongs on the order beside the leaf.
Panic bars and push pads: the hardware that releases a crowd
A panic bar runs across the leaf, and a push on any part of it throws the latch. The bar must cover at least 60% of the width of the leaf, so a person reaching for the door in the dark or in smoke finds the bar wherever their hand lands. The bar is proved to BS EN 1125, which covers panic exit devices for use where more than 60 people may need the way out.
A push pad suits a smaller room, where fewer people use the door and the leaf is narrower. The pad sits where the hand falls, and one push throws the latch the same way a bar does. The choice between a bar and a pad follows the number of people behind the leaf, not the look of the handle.
The bar and the pad must work with the lock beside them, not against it. A lock that holds the leaf shut from the outside must still let the bar throw the latch from the inside, because the way out matters more than the way in.
The leaf, the frame and the hinges: the doorset behind the bar
A panic bar is only as strong as the leaf it sits on. A leaf that bends under the push of a crowd will jam in its frame, and a bar on a leaf that jams opens nothing.
Hinges carry the leaf through every opening, and the weight they carry decides the grade they need. A hinge proved to BS EN 1935 is tested to 200,000 cycles, with grade 13 taking a leaf of 120 kg and grade 14 taking one of 160 kg, so the grade on the order follows the leaf. A hinge that gives way under the weight lets the leaf drop and drag on the floor, and a leaf that drags cannot shut on its own.
The frame must hold the leaf square, because a leaf that twists in its frame will not meet its keep. Fixings and anchors hold the frame to the wall, and the frame beside the leaf belongs on the order with the leaf. The steel versus timber fire doors guide works through the choice between leaf materials, and the keeping an LPS 1175 rating valid guide sets out what breaks a rating once a door is fitted.
Opening force and the child at the door: BS 8300 and Approved Document M
The force to open an exit door must stay below 30 N for the first 30 degrees of travel and below 22.5 N beyond, under BS 8300 and Approved Document M. The limit exists for the child, the older person and the person carrying a bag, because the door must open for the weakest person behind it, not the strongest.
A closer that is too strong fights the bar, and a door that needs a hard shove to open will hold a crowd back at the worst moment. The power size of the closer must suit the leaf, with no fire door taking less than EN 3 to BS EN 1154, and the closer is set on site so the leaf shuts without fighting the hand that opens it.
The force is tested on the round, with a gauge on the leaf and the result written against the door. The fire door inspection checklist names what each round should look for.
Holding fire back while letting people out: one leaf, two jobs
An exit door on a fire route must hold fire back for its period and still let people through in seconds. The leaf takes FD30 or FD60 to EN 1634-1, with the period following the fire load behind it, and the seals and the gap round the leaf must hold with it.
Smoke is the first danger on an escape route, before the flames arrive. A door on a smoke path takes FD30S, with the seal proved to BS EN 1634-3, to Sa for smoke at room temperature and S200 for smoke at 200 degrees Celsius, and the seal must be the one the test report names.
The two jobs share one leaf, so the leaf, the frame, the seals and the bar were proved together. A bar swapped for another after the test leaves the doorset different from the one tested, and a doorset that differs from the test has no proof. The fire and security doors dual certification guide works through how two proofs share one leaf, and the smoke control doors guide covers the doors that hold smoke back.
Where exit doors belong: halls, stairs and the rooms that empty fast
Exit doors belong where people gather and where the way out must be found in seconds. Assembly halls, sports halls and dining rooms take exit doors on every route out, because the crowd inside them cannot wait for a key or a code. The doors sit at the end of each escape route, where the corridor meets the stair or the open air.
Stair cores take exit doors at every floor, because every person in the building must reach the stairs through doors that shut behind them. A stair door that stands open lets smoke into the stair, and a stair full of smoke is no way out. The door on each floor takes the period the fire load behind it demands.
Schools, hospitals and stadiums each put exit doors where their crowds gather. The school security doors guide covers the doors on a site where keys change hands often, the hospital security doors guide works through the doors that must move beds and trolleys as well as people, and the stadium security doors guide covers the doors that must release a crowd.
The release that must work without power: keys, codes and the fail safe state
An exit door must open when the power fails, because the alarm that empties a building may sound in a blackout. Readers, fobs and codes open doors for staff who carry them, and the key stays as the override when the power fails or the reader breaks. A door that needs power to open is no door at all in a blackout, so the bar must throw the latch with no power behind it.
Access control on an exit door must fail safe, so the leaf releases when the power drops. The reader, the fob and the fail safe state belong on the order beside the leaf, and the fail position must be written on the order. A door that fails shut in a blackout traps the people behind it.
A hold-open device proved to BS EN 1155 lets an exit door stay open through the day and shuts it the moment the alarm sounds. The fire door regulations commercial buildings guide sets out the periods for the shared parts of a public building, and the how to specify security doors guide sets out the columns the schedule needs.
One schedule for the whole escape route: every exit door on one line
Put the exit door order together as one list, with a line for every door on the escape route and the leaf, the bar, the closer and the period beside each one, so the door that arrives matches the door that was proved. A schedule that names one door for the whole route leaves the fitter to guess which leaf takes which bar, and a guess is not a proof.
Read the quotation beside the schedule before the order goes out, and mark each bar, closer and seal as it is priced, so nothing is left off. A bar left off the price still has to be bought, and fitting it to a door that is already hung costs more than ordering it with the door. The security door cost factors guide sets out what each step up the scale adds to the price.
The round that looks after exit doors walks every escape route in turn and stops at each door. The bar, the closer, the seals and the gap are checked on every door, and a fault is written against the door it belongs to on the same day, so the repair is ordered before the next crowd needs the way out. The security door maintenance checklist covers the doors that must hold both fire and forced entry.
| Position | Door | Bar | What to check |
|---|---|---|---|
| Main entrance | Fire door, FD30 | Panic bar, BS EN 1125 | Bar, closer, seals |
| Assembly hall | Fire door, FD60 | Panic bar, BS EN 1125 | Bar, hinges, gap |
| Stair core | Fire door, FD60 | Panic bar, BS EN 1125 | Closer, seals, latch |
| Corridor | Fire door, FD30S | Push pad | Pad, closer, gap |
| Store | Fire door, FD30 | Push pad | Pad, lock, seals |
An exit door holds only as long as the leaf, the frame and the proof behind it, so the bar, the closer and the record must all sit on the same schedule.
What is a panic bar?
A bar across the leaf proved to BS EN 1125. A push on any part of it throws the latch, so a crowd can open the door with one action.
How wide must a panic bar be?
At least 60% of the width of the leaf, so a hand finds the bar wherever it lands.
Can an exit door also be a fire door?
Yes, where the leaf, the frame, the seals and the bar were proved together to EN 1634-1.
How hard may an exit door be to push?
Below 30 N for the first 30 degrees of travel and below 22.5 N beyond, under BS 8300 and Approved Document M.
Who keeps the record for exit doors?
The person who runs the building, with the building file. The record should name every door, the bar on it and the date each round checked it.