ArxBridge
Security Door Locks
Security door locks for estates and commercial buildings: TS 007 3-star cylinders, restricted keyways, boltwork and the key record naming who holds each key.
- ✓Third-party test evidence with every product
- ✓Written specification you can issue to tender
- ✓Supplied and installed across the UK
Get a free project quote
Rating, written specification and budget range within one working day.
Confidential. No cost, no obligation.
Third-party tested
Evidence with every quote
UK manufactured
Made to your sizes
One accountable team
Specify, supply, install
Confidential handling
Details never shared
A security door is only as strong as the lock that holds it shut. A leaf proved to LPS 1175 can still be forced in seconds if the lock behind it is weak, because the test that proves the leaf also proves the lock, the frame and the fixings as one doorset. The lock is not an extra on the order; it is part of the proof.
Locks for security doors are chosen by the attack they must face, not by the look of the handle. A cylinder that resists drilling, a bolt that throws deep into the frame, and a keyway that cannot be copied on the high street each add a layer.
The locks that suit a door are set out in the fire door hardware guide, and the fire door closers guide covers the closer that works beside the lock. A lock ordered without the leaf behind it may fit the wrong door, so the leaf, the frame and the lock belong on the same line of the order.
- TS 007 3-starCylinder and handle proved as a set
- B3 / C5 / D10Forced entry periods to LPS 1175
- BS EN 1935 grade 13 / 14Hinges proved to 200,000 cycles
- Restricted keywayBlanks held by the supplier
The lock that holds the line: what a security door lock must do
A lock on a security door has one job above all others: to keep the leaf shut against a person trying to force it. The bolt must throw deep into the frame, the cylinder must resist the drill and the snap, and the keep must hold when the leaf is pushed, pulled and levered.
The rating on the order follows the room the door guards. Forced entry is proved to LPS 1175, with B3 holding three minutes, C5 holding five minutes and D10 holding ten minutes, each against the tool set for its category, all under Issue 8.2, dated September 2024. The door that guards a bank vault takes a higher grade than the door that guards a store, because the risk behind the leaf decides the grade.
A lock must also work for the people who use the door every day. A key that turns stiffly, a handle that needs two hands, or a bolt that sticks in the keep will be left open, and a lock left open holds nothing back.
Cylinders that resist the drill: TS 007 and the 3-star set
The cylinder is the part an intruder attacks first, because it sits in the middle of the leaf where the key goes in. A cylinder proved to TS 007 carries a star rating, with a 1-star cylinder and a 2-star handle or escutcheon together making a 3-star set.
A cylinder that resists drilling takes hardened pins and plates inside, so the drill meets steel where it expects brass. A cylinder that resists snapping takes a sacrificial front, so the part that breaks away leaves the locking part still in the leaf. Each of those features must be the one the test report names, because a cylinder swapped for another after the test leaves the doorset different from the one tested.
The cylinder belongs on the order beside the leaf, with the star rating named beside it. The bank security doors guide works through the doors that guard cash and valuables, and the prison security doors guide covers the doors that must hold from the inside. A cylinder ordered without a rating leaves the fitter to guess, and a guess is not a proof.
Deadbolts, latches and multipoint: the boltwork behind the leaf
A latch holds a door shut for daily use, and a deadbolt holds it shut against force. The latch catches when the leaf meets the frame, and the deadbolt throws into the keep when the key turns, so the leaf is held by steel on both sides of the frame. A door with a latch and no deadbolt can be pushed open once the latch is slipped, and a door with a deadbolt and no latch must be locked every time it shuts.
Multipoint locking throws bolts at the top, the middle and the bottom of the leaf, so the leaf is held along its full height. A tall leaf held by one bolt in the middle can be levered at the top and the bottom, while a leaf held at three points spreads the force across the frame.
The boltwork must suit the leaf it sits in. The steel versus timber fire doors guide works through the choice between leaf materials, and the factory security doors guide covers the doors that take the shift on a factory floor.
Restricted keyways: blanks that cannot be cut on the high street
Control starts with the blank, not with the key. A restricted keyway means the blanks live with the supplier, and a new key is cut only when the person who runs the building asks for one in writing.
Name the keyway on the order beside the cylinder, with the number of keys beside it. A building that needs forty keys should order forty from the start, because a key cut later by a locksmith who was never told about the restriction may be cut on a blank that fits the lock but was never proved with it. The school security doors guide covers the doors on a site where keys change hands often, and the record that names who holds each key belongs with the order.
A lost key tests the restriction. On a restricted system the answer is to change the cylinder the key opened, and the change is made the same day the loss is found. On an open system every key on the building is suspect, because a key that can be copied anywhere may already have been copied.
Keying beside the access system: one key for the doors that belong together
A building with many doors needs its keys planned, not piled up. One key can open the doors that belong together, while each door still takes only the keys it should. A cleaner opens the rooms they clean and no others, a manager opens the whole floor, and the master key opens every door on the site.
The access system sits beside the keying, not instead of it. Readers, fobs and codes open doors for staff who carry them, and the key stays as the override when the power fails or the reader breaks. A door that needs power to open is no door at all in a blackout, so the key must work when the reader does not. The fire door regulations commercial buildings guide sets out the periods for the shared parts of a public building.
The key plan belongs on the schedule with the locks, naming each door, the key that opens it, and the person who holds that key. The how to specify security doors guide sets out the columns the schedule needs.
Locks on a fire door: the proof that must stay together
A lock on a fire door must be the lock the test report names, because the leaf, the frame, the seals and the lock were proved together to EN 1634-1. A lock swapped for another after the test leaves the doorset different from the one tested, and a doorset that differs from the test has no proof.
People must still get out without a key, whatever the lock says, because the way out matters more than the way in. A panic bar to BS EN 1125 throws the latch when pushed, and it must work with the lock beside it, not against it. The fire and security doors dual certification guide works through how the two proofs share one leaf, where a door must hold fire and resist attack at once.
Closers on a fire door need a power size of EN 3 or above to BS EN 1154, and a closer that is too strong fights the lock while a closer that is too weak leaves the leaf standing open. The keeping an LPS 1175 rating valid guide sets out what breaks a rating once a door is fitted.
The cylinder that stands proud: the grip an intruder looks for
A cylinder that stands proud of the furniture gives an intruder something to grip, so the cylinder is set flush with the furniture on both faces of the leaf. The three-star rating comes from a one-star cylinder with a two-star handle under TS 007, and the order names the pair together, because one without the other leaves the rating short.
Every lock needs a pocket cut into the leaf, and the pocket weakens the very leaf the fire must be held back by. The depth of the pocket and the width of the cylinder hole are set by the test report, so a lock that needs a deeper pocket than the report allows leaves the leaf thinner where the fire reaches it first. The order should name the lock by model, so the pocket cut on site matches the pocket the report describes.
A latch that stops short of the strike leaves the leaf free to swing, so the latch is tried by shutting the leaf and pulling it without touching the handle. Where the latch sits only halfway in the strike, the strike is moved before the lock is blamed, and where the leaf has dropped on its hinges the hinges are put right first.
Multipoint boltwork throws bolts at the top, the middle and the foot of the leaf, so the leaf is held at three points rather than one, and the bolts should move together when the handle turns. A bolt that lags behind the rest shows as a handle that will not turn fully, and the keep it meets is checked before the lock is blamed.
The key that opens too many doors: the record that names every holder
The record should name who holds each key, because a key that opens a door it should not open can be traced back to its holder only where the record names them. A key reported lost is struck off the list the same day, and the lock it opened is changed where the key could reach the rooms behind it.
Restricted keyways take blanks that cannot be cut on the high street, so a key cannot be copied without the order that names it. The blanks are held by the supplier, and a copy is cut only against a written order from the person the record names, so no copy leaves the supplier without a name beside it.
Keying beside the access system lets one key open the doors that belong together, so the staff who work the office can open the office and the cash room without carrying two keys. The keying is written on the order beside each door, with the doors that share a key named together, so the fitter is not left guessing which key opens which leaf.
The lock, the leaf and the frame face the fire test together, so a lock changed on site for a model the report never names breaks the proof the doorset was ordered with. The replacement is ordered by model, and the cut it needs is the cut the report allows, so the leaf that stands in the opening is the leaf the report describes.
| Part | What to check | What breaks it | When |
|---|---|---|---|
| Cylinder | Flush both faces | Stands proud | At handover |
| Lock case | Pocket matches report | Cut too deep | At handover |
| Boltwork | Bolts move together | Bolt lags behind | Each round |
| Keyway | Blanks held by supplier | Copied on high street | Before the order |
| Record | Every holder named | Lost key untraced | Each month |
What the hinges that carry the leaf must do is named in the fire door hardware guide, and readers, releases and wiring beside a leaf are covered in the door entry systems guide. What can break a rating once a door is fitted is named in the keeping an LPS 1175 rating valid guide, and the columns the order must hold are worked through in the how to specify security doors guide.
The lock record: who holds each key, and what happens when one is lost
The record shows the keying is under control. Each key given out should leave a line naming the key, the doors it opens, the person who holds it and the date it was given, so the next person who opens the file can see where every key is without walking the building.
When a key is lost, the record decides the response. A lost key on a door that guards a store means the cylinder on that door is changed, while a lost master key means every cylinder on the plan is changed, because the key that opens every door opens every door.
The person who runs the building owns the record, and a responsible person will ask to see it first. It lives with the building file, in one place, and it is kept current, because a record that is months out of date tells no one where the keys are. The fire door inspection checklist names what each round should look for, and the security door maintenance checklist covers the doors that must hold both fire and forced entry.
One schedule for the whole estate: every lock on one line
Put the lock order together as one list, with a line for every door on the estate and the lock, the cylinder, the keyway and the keys beside each one, so the lock that arrives matches the lock that was proved. A schedule that names one lock for the whole estate leaves the fitter to guess which leaf takes which cylinder, and a guess is not a proof.
Check every line of each quotation against the schedule before the order goes out, so no lock, cylinder or key is left off the price. Anything missed from the quotation still has to be bought, and fitting it to a door that is already in place costs more than ordering it with the door. The security door cost factors guide works through what each step up the scale adds to the price.
The choosing a ballistic rating guide works through the grades a pane can carry, and the fire rated windows cost factors guide covers the windows that share the same wall.
| Position | Lock | Proof | What to check |
|---|---|---|---|
| Main entrance | Multipoint, TS 007 3-star | LPS 1175 B3 | Bolts, cylinder, keeps |
| Plant room | Deadbolt, restricted keyway | LPS 1175 C5 | Bolt, keyway, frame |
| Office corridor | Latch and deadbolt | FD30 | Latch, closer, seals |
| Store | Deadbolt, TS 007 3-star | LPS 1175 B3 | Bolt, cylinder, record |
| Safe room | Multipoint, TS 007 3-star | LPS 1175 D10 | Bolts, keeps, record |
A lock holds only as long as the leaf, the frame and the proof behind it, so the cylinder, the boltwork and the key record must all sit on the same schedule.
What is a TS 007 3-star lock?
A set proved as one: a 1-star cylinder with a 2-star handle or escutcheon. The set resists drilling and snapping, and the rating belongs to the set.
What is a restricted keyway?
A keyway whose blanks are held by the supplier and cut only on the order of the person who runs the building, so a key cannot be copied on the high street.
Can one key open many doors?
Yes, where the key plan says so. Keying lets one key open the doors that belong together, while each door still takes only the keys it should.
Can a lock sit on a fire door?
Yes, where it is the lock the test report names. The leaf, the frame, the seals and the lock were proved together to EN 1634-1.
Who keeps the key record?
The person who runs the building, with the building file. The record should name every key, the doors it opens, the person who holds it and the date it was given.
Get a free quote
Related
More in guides for specifiers
Products
One supplier for the whole building envelope
Ready to specify your project?
Free assessment, written specification and test evidence. Reply within one working day.