Bank door rules: rated doorsets for branches, strongrooms and cash handling areas, with the access control and ratings that order a whole estate.
- ✓Third-party test evidence with every product
- ✓Written specification you can issue to tender
- ✓Supplied and installed across the UK
Get a free project quote
Rating, written specification and budget range within one working day.
Confidential. No cost, no obligation.
Third-party tested
Evidence with every quote
UK manufactured
Made to your sizes
One accountable team
Specify, supply, install
Confidential handling
Details never shared
A bank branch holds cash, records and people in the same building, and the doors between them decide what an intruder can reach and how fast. The counter meets the public all day, the cash room sits behind it, and the strongroom sits behind that, so each door on the way in has to hold longer than the one before it.
The order starts with the risk, not with the leaf. A branch on a busy high street faces a different attack from a branch on a quiet road, and a strongroom faces a different attack from a staff entrance, so the rating follows the opening, not the building.
The rating, the access control, the fire proof and the records all sit inside one schedule, and an order that names each one plainly puts the right doorset on the right opening. The columns for that schedule are set out in our how to specify security doors guide, and the banking sector page covers the branches, strongrooms and cash rooms the doors guard.
- LPS 1175 B3 / C5 / D10Forced entry ratings, three, five and ten minutes
- LPS 2081 SRA / SRBStealth ratings, one and three minutes
- PAS 24Enhanced security doorset
- FD30 / FD60Fire resistance periods tested to EN 1634-1
Branches, strongrooms and cash rooms: where a bank puts its doors
Every branch has three kinds of space: the floor the public walks on, the rooms where staff handle cash, and the strongroom where the cash rests overnight. Each kind of space asks for its doors in a different place, and the rating rises as the cash gets closer.
The counter door separates the public floor from the staff area, and it works all day. Staff pass through it with cash, documents and keys, so it has to open quickly for the right hands and hold against the wrong ones, and a door that fails at either duty leaves the cash room open to the floor.
Walk the branch and note every door a person can reach, then set each one by the attack it could face. A staffed main entrance faces less risk than a rear door onto a lane nobody watches after dark, so the rating follows the door, not the branch. Our security door specification mistakes guide covers the errors that leave a rating short of the opening.
The strongroom door: the highest rating on the branch
The strongroom holds the most value in the branch, so its door takes the highest rating on the site. A strongroom door that holds for ten minutes against the heaviest tools gives the alarm time to work and the response time to arrive, and a door rated below the value behind it leaves the strongest room guarded by the weakest proof.
The wall behind the strongroom door carries the rating as much as the leaf does. A D10 leaf fitted into a weak surround lets the attack pass beside the door, so the schedule must name the wall and the fixings beside the leaf, and the test report must cover the whole assembly as fitted.
The strongroom door needs a lock that matches the leaf. A lock that resists the same tools for the same minutes belongs on the schedule beside the rating, and a door whose lock gives way before the leaf does has no rating at all in practice. Our safe room door specification guide works through the same discipline for rooms that hold value.
B3, C5 and D10 across a branch: matching the rating to the opening
LPS 1175 grades a doorset by the tools it resists and the minutes it holds. A doorset that holds for three minutes against the category B tool set carries B3, five minutes against the category C tool set carries C5, and ten minutes against the category D tool set carries D10, and the current labels come from Issue 8.2, dated September 2024.
Older drawings still show the earlier labels, so read SR2 as B3, SR3 as C5 and SR4 as D10, and ask for the current label on the order rather than the one on the drawing. For the full rating tables, see the LPS 1175 page; for the choice between the two routes, see our LPS 1175 versus PAS 24 guide.
A branch entrance usually takes B3, a cash room C5, and a strongroom D10, but the risk assessment sets the rating for each opening, not the habit of the last order. A doorset to PAS 24 is the enhanced security route, while EN 1627 grades doorsets from RC1 to RC6 on its own scale. The two scales are proved by different tests, so naming one when the order means the other asks for evidence that was never produced. The comparison between them is set out in our LPS 1175 vs EN 1627 guide.
The strongroom and the branch door: two ratings on one estate
A branch holds two kinds of value. The strongroom holds cash and documents behind a door that takes the highest rating, while the branch doors open for staff and customers all day. The rating follows the value behind the door, not the size of the branch.
Under LPS 1175, the grade names the minutes a door holds against the tool set for its category. B3 stands for three minutes against category B tools, C5 for five minutes against category C tools and D10 for ten minutes against category D tools, all under Issue 8.2, dated September 2024. The strongroom takes the highest grade the estate can justify, and the branch doors take the grade that matches the room they guard. Our LPS 1175 page lists the grades in full.
A branch door that takes the same grade as the strongroom wastes the budget, and a strongroom door that takes a branch grade leaves the cash unguarded. The order should name the grade beside each opening, so the fitter knows which door goes where and the test report names the same door. How a schedule should name each proof is set out in our how to specify security doors guide.
The frame, the hinges and the lock carry the rating as much as the leaf does. Hinges to BS EN 1935, grade 13 carrying 120 kg and grade 14 carrying 160 kg, each through 200,000 cycles, and a TS 007 3-star set, made of a 1-star cylinder with a 2-star handle or escutcheon, keep the hardware proved with the leaf.
Fire and forced entry share the branch door where the room needs both. A door that must hold fire takes FD30 or FD60 proved to EN 1634-1, and the two proofs sit on separate lines because each is proved on its own test, and one test report cannot prove both. How the two proofs sit together is worked through in our fire and security doors dual certification guide.
Stealth after hours: the branch that empties at night
A branch that empties at night faces a quiet attack, so the rating must hold when no one is watching. LPS 2081 grades doors that must resist a stealth attack, with SRA holding one minute and SRB holding three minutes, and the grade on the order should match the hours the branch stands empty.
Unmanned branches and ATM rooms take the stealth grade beside the forced entry grade, because a thief who works quietly needs a different proof from one who works fast. The two grades sit on the same schedule line, and the test report must name both.
Access control keeps the branch doors together, so one card opens the rooms a member of staff uses and one stopped card stops working everywhere at once. The record should name who holds each card and each key, and a card that belongs to staff who have left must be stopped the same day.
Grilles and hatches guard the line behind the counter, where cash passes from hand to hand. The grille, the hatch and the door behind them belong on the same line as the leaf, so the counter that arrives is the counter that was tested.
| Opening | Rating | Hardware | Evidence |
|---|---|---|---|
| Branch door | LPS 1175 B3 | TS 007 3-star, grade 13 hinges | Test report names the doorset |
| Strongroom | LPS 1175 D10 | TS 007 3-star, grade 14 hinges | Test report names the doorset |
| ATM room | LPS 2081 SRB | TS 007 3-star, reader | Test report names the doorset |
| Counter grille | LPS 1175 B3 | Frame, fixings | Test report names the assembly |
Put the rating, the stealth grade and the hardware on one schedule line for every branch, so the next reader can see what was tested and what holds it. What each step up the scale adds to the build is worked through in our security door cost factors guide.
Stealth at night: LPS 2081 for unmanned branches and ATM rooms
A branch that empties at night faces a different attack from one that stays staffed. LPS 2081 tests a doorset against an attack that stays quiet, with SRA at one minute and SRB at three, and the minutes follow the site: a branch watched by cameras spots the attempt quickly, while an unmanned ATM room gives the attack longer to work.
The stealth proof says nothing about a loud attack with hand tools, so a door that needs both proofs carries both ratings on the same line of the schedule. An ATM room door that holds against a quiet attack but falls to a crowbar in three minutes has only half a rating, so the schedule names both proofs for every door that stands empty overnight.
Access control in a branch: who opens which door, and when
The reader, the fob and the intercom each suit a different door. Staff who pass the same door every day take a card or a fob, a visitor with no card takes the intercom, and a door that many hands use takes a code that can be changed when staff leave.
When the power goes, the doors must fail safe, so staff can still leave. The release on power failure belongs in the specification beside the reader, because a door that locks shut in a power cut traps staff inside with the cash.
One card system should cover the whole estate, not one system per door. A card that opens the branch entrance should open the staff areas and the service yard as well, and the office that issues the cards should be able to stop one card without stopping the rest. Readers, fobs and biometrics in the lane are covered in our security turnstiles guide.
Fire and forced entry on one doorset: the dual proof
A single leaf can carry both proofs, but only where the test evidence names both jobs for the assembly that will be fitted. How the two proofs sit on one doorset is worked through in our dual certification guide.
Fire and forced entry are proved by different tests, and both proofs must name the doorset that will be fitted: the fire side to EN 1634-1, the forced entry side to LPS 1175 or PAS 24. A branch door on an escape route usually takes FD30, a door in a compartment wall usually takes FD60, and a door on a smoke path takes FD30S, with a smoke seal proved to BS EN 1634-3 and the gap round the leaf held at 4 mm.
Closers, hinges and seals carry the fire rating as much as the leaf does. A closer to BS EN 1154 must pull the leaf shut every time, with no fire door taking less than EN 3, and hinges to BS EN 1935 carry the leaf through its life: grade 13 is proved for 200,000 cycles at 120 kg, and grade 14 for the same cycles at 160 kg. The grades and the parts that make a fire door work are covered in our fire door hardware guide.
Grilles, hatches and the line behind the counter
Not every opening in a bank takes a leaf. A cash hatch lets staff pass documents and cash without opening a door, and a grille lets air and speech through while the counter stays shut, so the hatch and the grille belong on the schedule beside the doors. The security hatches page covers the hatches, and our LPS 1175 gates and grilles guide covers the ratings behind them.
The glass behind a counter is proved to EN 1063, from BR1 to BR7, and each step up the scale adds layers, weight and thickness to the pane. The frame and the fixings must carry that weight, and the wall behind the frame must take the fixings, or the pane holds a rating the opening cannot. How the glass and the frame are proved together is set out in our choosing a ballistic rating guide, and the scales sit side by side on the ballistic ratings page.
A branch that faces a road needs more than a door on the front. The vehicle line outside takes its own rating from ISO 22343-1, proved against vehicles from a 1,500 kg car to a 30,000 kg truck at 48, 64 or 80 km/h, and the barrier, the gate and the bollards on that line all carry the same rating. The options are worked through in our anti-ram gates and barriers guide, and the blockers that rise from the road are covered in our road blockers guide.
Ordering for the whole estate: one schedule, every branch on it
Build the enquiry as a specification, with one line for every door in every branch. Each line names the branch and the position, the forced entry rating, the stealth rating where one is needed, the fire period and the smoke seal, and the leaf, frame, glass, seals and hardware as one doorset. Where a door must resist attack as well as fire, the rating belongs on the whole doorset, proved to LPS 1175 or PAS 24, and never on the leaf alone.
Have the test report, the classification and the hardware schedule travel with the doors, and file them the day the doors arrive. The handover pack should name the inspection routine the estate will follow, so the record covers the whole life of the doors. What each check looks for is set out in the fire door inspection checklist.
| Door position | Door | Rating | What to check |
|---|---|---|---|
| Branch entrance | Swing security door | LPS 1175 B3 | Closer, reader, self-closing |
| Counter to cash room | Security door | LPS 1175 C5 | Lock, closer, seals |
| Strongroom | Vault door | LPS 1175 D10 | Lock, hinges, fixings |
| ATM room | Security door | LPS 2081 SRB | Lock, seals, self-closing |
| Staff entrance | Security door | LPS 1175 B3 | Reader, closer, latch |
A bank door guards cash, records and people in the same building, so the rating, the access control and the fire proof must all sit on the same schedule.
What security rating do bank doors need?
The estate decides, by the opening and the value behind it. A branch entrance often takes B3, a cash room C5, and a strongroom D10, and the risk assessment names the rating for each door.
Do bank doors need a stealth rating?
Where a branch or an ATM room stands empty overnight, yes. LPS 2081 proves the doorset against a quiet attack, with SRA at one minute and SRB at three, and the rating sits beside the forced entry rating on the same line.
Can one bank doorset hold a fire rating and a security rating?
Yes, where the doorset carries a test report for each job. EN 1634-1 proves the fire side and LPS 1175 or PAS 24 proves the forced entry side, and each report must name the doorset that will be fitted.
What breaks a bank door rating?
A lock that gives way before the leaf, a hinge that drops, a closer that cannot shut the leaf, or a wall that cannot take the fixings. Repair or replace it, and record the work.
Who checks bank doors?
The team that runs the estate, on the routine the security plan sets. Each record names the door, the fault, the repair and the date it was fixed.