ArxBridge
Garage Security Doors Explained
Roller, sectional and side-hinged garage doors compared for security: ratings, locks, power safety, insulation and what the order must name.
- ✓Third-party test evidence with every product
- ✓Written specification you can issue to tender
- ✓Supplied and installed across the UK
Get a free project quote
Rating, written specification and budget range within one working day.
Confidential. No cost, no obligation.
Third-party tested
Evidence with every quote
UK manufactured
Made to your sizes
One accountable team
Specify, supply, install
Confidential handling
Details never shared
A garage door is the largest opening in most homes and the weakest point in many of them. It guards vehicles, tools, bicycles and stored goods, and in a home with an internal door it also guards the way into the house itself. Yet it is often bought as a curtain that keeps the weather out, not as a security door that must resist attack. Judge it the way you would judge any other security door: by the leaf, the frame, the guides or tracks, the locking and the fixings, and by the test evidence that covers all of them together.
Three types do this work: roller doors, sectional doors and side-hinged doors. Each opens in a different way, each has different weak points, and each suits a different opening. The sections below take them in turn, then set out the ratings that apply, the safety rules for powered doors, and what the order must name. Our types of security doors guide places garage doors beside the other security door types, and our security shutter versus roller door guide compares the roller principle with the high performance door used on commercial openings.
- Three typesRoller, sectional and side-hinged garage doors
- LPS 1175 A1 to H20Forced entry ratings, with B3, C5 and D10 the common levels
- EN 12453Safety in use of power operated garage doors
- One tested assemblyLeaf, guides, frame and locks tested together
A garage door is a security door, not a curtain
Start with what the door protects. A garage holds more than a car. It holds power tools, bicycles, ladders, garden machinery and boxes that are easy to carry away, and in many homes the internal door from the garage into the house is a standard internal door, not a security doorset. Once the garage door is open, the house is open too. That is why the garage door deserves the same treatment as a front door: a rating, a tested assembly and locks that hold the leaf in its frame.
The attack on a garage door is usually simple. The leaf is lifted from the bottom, prised from the side, or the guides are spread so the curtain or the panels can be pulled out. A door with a strong leaf and a single lock point fails at the lock, because the rest of the leaf can be flexed away from the frame. Security comes from the whole assembly holding together: the leaf resists the tool, the guides or tracks hold the edges, and the locking holds the leaf to the frame at enough points to stop it being prised open.
Size works against the garage door. A single garage opening is often more than two metres wide, and a double garage opening wider still, so the leaf is large and the leverage on it is large too. A rating earned on a small test opening does not automatically apply to a wide one, so check that the evidence names the size being ordered.
Roller garage doors: the coil, the guides and the lock
A roller garage door is a curtain of horizontal laths that rolls up into a box above the opening. It needs no room inside the garage for the door to swing or slide, so it suits a garage where the car is parked close to the opening or where the ceiling is used for storage. The curtain runs in guides on each side of the opening, and the guides are the part that decides how secure the door is. Deep guides with the curtain held firmly inside them resist prising far better than shallow guides, and the fixings that hold the guides to the wall matter as much as the guides themselves.
Locking on a roller door works in one of two ways. A manual roller door is locked by bolts that shoot into the guides, or by a ground lock at the bottom of the curtain. A powered roller door is held by the motor and its brake, and by any separate locking fitted with it. Ask which of these the door relies on, and whether the lock holds the curtain at one point or at both sides. For how the same roller principle is priced on commercial openings, see our roller shutter cost factors guide, and for the fire rated version of the curtain, see our fire rated roller shutters page.
Insulated laths are common on roller garage doors, and they do two jobs at once: they slow heat loss through the opening and they stiffen the curtain. The box above the opening needs attention too: it must be fixed soundly, and the curtain must roll freely inside it without catching, because a curtain that catches does not close fully and a door that does not close fully does not lock.
Sectional garage doors: panels, tracks and the weak points
A sectional garage door is made of horizontal panels hinged together, running on tracks that carry the door up and then back along the ceiling. Each panel is rigid, so the door as a whole is stiffer than a roller curtain, and the panels can carry thick insulation, which makes the sectional door the warmest of the three types. It needs headroom inside the garage for the tracks and the horizontal run, so it suits a garage with a clear ceiling and a car parked well back from the opening.
The weak points of a sectional door are the joints between the panels and the fixings that hold the tracks to the wall and ceiling. The panels are joined by hinges, and the hinges and the rollers that run in the tracks carry the whole weight of the door. Check that the hinges are sized for the panel weight and that the track fixings go into solid structure, not into plasterboard or a weak lintel.
Locking on a sectional door is usually by the operator, which holds the door closed through the drive, or by manual bolts into the tracks. Ask whether the operator alone holds the door, and what happens when the power fails: a door that can be lifted by hand once the power is off is a door with no lock. A sectional door with a pedestrian wicket, a small door set into one of the panels, needs the same attention, because the wicket is a door inside a door and its hinges and lock must be part of the tested assembly. For the commercial doors that use the same sectional principle at larger sizes, see our loading bay doors guide.
Side-hinged garage doors: the simplest leaf, the strongest hinges
Side-hinged garage doors are two leaves hung on hinges, opening outwards like a pair of double doors. They are the simplest of the three types and the easiest to understand, because they work like any other hinged door. There is no curtain to coil and no track to run, so there is nothing overhead to maintain, and the leaves can be opened one at a time for pedestrian access without opening the whole garage. They suit a garage used as a workshop, where the door is opened and closed by hand many times a day and where a powered door would be a nuisance.
The hinges carry everything on a side-hinged door, so they must be sized for the weight of the leaf and fixed into solid structure. A leaf that sags on weak hinges does not close squarely, and a door that does not close squarely does not lock. The locking should be multipoint, with shoot bolts at the top and bottom of each leaf as well as a lock at the meeting point, so the leaf is held to the frame along its full height.
Side-hinged doors need clear space outside the opening to swing, so they do not suit a garage with a short drive or a car parked close to the door. They also need a threshold that the leaves can close against, and the threshold must be fixed soundly, because the shoot bolts at the bottom of each leaf lock into it. Where the garage floor is uneven, the threshold and the leaves must be fitted to match it, or the bottom bolts will not engage.
Security ratings on a garage door: LPS 1175, PAS 24 and RC classes
Three rating systems apply to garage doors, and each answers a different question. LPS 1175 is the forced entry test for security products, with ratings from A1 to H20. The common levels are B3, C5 and D10, each naming the tools and the attack time the product resisted. Our LPS 1175 page sets out the full rating table and how to read it.
EN 1627 gives the RC classes, from RC1 to RC6, for burglar resistant doorsets and windows. The RC class describes the resistance of the whole doorset, including the frame, the locking and the glazing where there is any, against a defined set of tools and methods. A garage door carrying an RC class has been tested as a complete doorset, and the class should be read with the test report behind it. LPS 2081 sits beside these two: it tests security doorsets against a short, intense attack, with SRA rated at one minute and SRB at three minutes, and it suits openings where the threat is a fast, forceful entry rather than a long, quiet one.
PAS 24 is the enhanced security test for doorsets in new dwellings, and it is the standard that Approved Document Q points to for doors in new homes. A garage door on a new dwelling, or the pedestrian door from the garage into the house, may need to meet PAS 24, so check the building regulations position for the project before ordering. The cylinder in the lock deserves the same attention as the door: a TS 007 rated cylinder, with a 1-star cylinder and a 2-star handle giving a 3-star combination, resists snapping and picking far better than an unrated cylinder. Secured by Design is a scheme, not a rating, and it describes products that meet its requirements; it is not a test standard on its own. Our PAS 24 requirements guide and our Secured by Design guide set out both in full.
The leaf, the frame and the floor: where a garage door fails
A garage door is a security door, not a curtain, and the attack takes the weakest part of the assembly. A strong leaf set in a weak frame fails at the frame, a frame fixed to a wall that cannot take the fixings fails at the wall, and a leaf that leaves a gap at the floor fails at the floor. Buy the leaf, the frame and the fixings together, as one tested assembly, and ask for the test report that names all three, because a rating proved on one assembly does not carry to another.
The LPS 1175 grade comes from the tools and the time: what the doorset resists and how long it holds. Three minutes against screwdrivers, pliers and hand saws is B3. Five minutes against crowbars, drills and chisels is C5. Ten minutes against sledgehammers, disc cutters and jigsaws is D10. Issue 8.2 of LPS 1175, dated September 2024, holds the current names, and older drawings still carry SR2, SR3 and SR4, which read as B3, C5 and D10 in that order. The full forced entry ratings sit on our LPS 1175 page.
A garage door that must also meet a building regulation needs a second proof beside the first. PAS 24 covers the enhanced security doorset, and EN 1627 sets its own classes, RC1 to RC6, and each one needs its own test report behind it. No published table converts an LPS 1175 rating into an EN 1627 class, so name the standard the insurer or the client will accept before the order is placed. Our roller shutter regulations guide sets out the rules that govern a shutter, and the same discipline runs through a garage door.
Locks, cylinders and the door that must still open by hand
The lock must resist attack without trapping anyone inside. A thumb turn on the inside lets the resident leave without a key, and a cylinder that meets TS 007, a 1-star cylinder with a 2-star handle or escutcheon giving a 3-star set, resists attack from the outside. A lock that resists attack but traps the people inside has failed its other duty, and the lock on an escape route must still release in one action, without a key.
A hinge carries the leaf through thousands of openings in a year, and a hinge that sags leaves a gap the seals cannot close. Hinges are graded by cycles and load to BS EN 1935: grade 13 covers 200,000 cycles at 120 kg, and grade 14 covers 200,000 cycles at 160 kg. A heavy leaf on a hinge grade too light for it drops on its hinges, drags on the floor and stops latching, so put the hinge grade on the schedule beside the rating.
| Part | Rating | What to check |
|---|---|---|
| Leaf and frame | B3, C5 or D10 | Tested together as one assembly |
| Lock and cylinder | TS 007 3-star set | Thumb turn inside, release in one action |
| Hinges | Grade 13 or 14 | Cycles and load against the leaf weight |
| Floor seal | Intact, no gap | Gap at the floor lets tools under the leaf |
Keep the test report, the rating and the hardware schedule with the door from the day it arrives, and ask for the evidence on the whole doorset, a rating to LPS 1175 or PAS 24, not a rating for the leaf alone. Our how to specify security doors guide sets the columns for the same discipline.
Power, safety and the door that must stop when it meets something
A powered garage door is a machine, and the safety rules for it are set out in EN 12453, the standard for safety in use of power operated doors, and EN 13241, the product standard for garage doors. EN 12453 covers power operated vertically moving commercial doors such as rolling shutters, and the same principles apply to a powered garage door at home: the door must stop or reverse when it meets an obstruction, and it must not close on a person, a pet or a vehicle.
The safety devices that do this are a safety edge on the bottom of the door, which stops the door when it touches something, and photocells across the opening, which stop the door when the beam is broken. Both should be part of the order, not extras added later, and both should be tested at handover. A door with no safety edge and no photocells relies on the force limit of the operator alone, and a force limit set too high will not stop the door in time. Ask for the safety devices by name in the specification, and check that they are fitted and working before the door is accepted.
Manual override matters as much as the safety devices. When the power fails, the door must still be openable from inside. Check the release mechanism, make sure everyone who uses the garage knows where it is and how it works, and test it before the door is signed off. The duty of the door also matters: a door on a home garage may cycle a few times a day, while a door on a workshop may cycle far more often. The live comparison on our shutter pages gives the shape of it: under ten cycles a day a shutter wins, over thirty a day a high performance roller door pays back, and a busy warehouse roller door may cycle fifty or a hundred times a day. Match the operator and the door to the use, not to the price. Our high performance roller doors page covers the doors built for heavy daily use.
Insulation, draughts and the garage that doubles as a workshop
Many garages are no longer just a place to park. They are workshops, gyms, storage rooms and home offices, and the door is the part of the room that loses the most heat. An uninsulated single skin door lets heat out in winter and lets condensation form on the inside face, and condensation on a steel door runs down onto tools and stored goods. Insulated laths on a roller door, insulated panels on a sectional door, or insulated leaves on a side-hinged door all slow that loss, and the seals around the opening matter as much as the insulation in the leaf.
Draughts come through the gaps, not through the leaf. The seal at the bottom of the door, the seals at the sides and the seal at the head all need to meet the opening when the door is closed, and a door that is not adjusted squarely leaves a gap at one corner that no seal can close. Check the seals in daylight: stand inside the garage with the door closed and look for light coming through around the edges. Light coming through is air coming through, and air coming through is heat leaving. A door that has been fitted squarely and adjusted properly shows no light at the edges.
Ventilation is the other side of the same question. A garage that is sealed tight with no air movement will hold damp inside, and damp inside a garage rots timber, rusts steel and grows mould on stored goods. Where the garage is used as a workshop, name the ventilation in the specification alongside the insulation, so the room stays dry without losing all its heat. The door is one part of that balance, not the whole of it, and the specification should treat the garage as a room, not as a box with a curtain on it.
What the order must name, and the checks that keep the door working
Most garage door problems are ordering problems. The door that arrives is the door that was written down, so write the order as a list, not as a single line. Name the type, the opening size, the leaf or curtain build, the guides or tracks, the locking and how many points it holds, the safety devices, the operator and its duty, the insulation and the seals, and the rating with the test report behind it. Where a rating is claimed, ask for the report number and check that the size, the type and the locking in the report match the order. A rating for a different size or a different locking set is not a rating for the door being bought.
Fixings belong on the list too. The guides, tracks, hinges and frame must be fixed into solid structure, and the specification should say what that structure is and how the fixings go into it. A door fixed into a weak lintel or into plasterboard will pull away under attack or under its own weight, and no leaf can make up for fixings that fail. Where the wall is not solid, name the steel or timber frame that carries the door, and check that the frame itself is fixed soundly.
After fitting, the door needs a routine. Check the guides or tracks for damage, the seals for wear, the locking for smooth operation and the safety devices for a proper stop, and do it on a schedule rather than waiting for a failure. Our fire door inspection checklist gives the shape of a good routine, and the same habit of regular checks applies to a garage door. For the cost factors that shape a garage door quote, see our security door cost factors guide and our how to specify security doors guide, and for keeping a doorset working after fitting, see our maintenance page.
| Type | How it opens | Security strength | Best for |
|---|---|---|---|
| Roller | Curtain of laths rolls into a box above the opening | Deep guides and both side locking; insulated laths stiffen the curtain | Short drives and garages where ceiling space is used |
| Sectional | Hinged panels run on tracks up and back along the ceiling | Rigid panels; hinges and track fixings carry the load | Workshops needing insulation and a warm, draught free room |
| Side-hinged | Two leaves swing outwards on hinges | Multipoint locking with shoot bolts top and bottom | Workshops opened by hand many times a day |
Buy the tested assembly, not the leaf. A garage door with no test evidence for the rating it claims has no rating to check.
Which garage door type is most secure?
No type is most secure on its own. Security comes from the tested assembly: the leaf, the guides or tracks, the locking and the fixings, with a rating such as LPS 1175 or an RC class from EN 1627 behind them. A roller door with deep guides and both side locking can outdo a sectional door with weak track fixings, and a side-hinged door with multipoint locking can outdo both.
Can a roller garage door carry an LPS 1175 rating?
Yes, where the whole doorset has been tested to LPS 1175 and the rating names the door type, the curtain, the guides, the locking and the size. The rating belongs to the tested assembly, so ask for the test report and check that what was tested matches what is being ordered.
Does PAS 24 apply to garage doors?
PAS 24 is the enhanced security test for doorsets in new dwellings, and it is the standard Approved Document Q points to for doors in new homes. Whether it applies to a particular garage door depends on the project and the building regulations position, so check that position before ordering rather than assuming the standard applies or does not apply.
What safety devices does a powered garage door need?
A safety edge on the bottom of the door and photocells across the opening, both named in the specification and tested at handover. EN 12453 sets out safety in use for power operated doors, and EN 13241 is the product standard for garage doors. A door with neither device relies on the operator force limit alone.
How often should a garage door be checked?
On a schedule, not when it fails. Check the guides or tracks, the seals, the locking and the safety devices regularly, and test the manual release so the door can still be opened when the power fails. A door that is checked on a routine stays square, stays locked and stays safe.
Get a free quote
Related
More in guides for specifiers
Products
One supplier for the whole building envelope
Ready to specify your project?
Free assessment, written specification and test evidence. Reply within one working day.