ArxBridge
Supermarket Security Doors
A supermarket guards cash, stock and deliveries behind its doors, so each leaf takes the grade the room behind it demands, from the till to the yard.
- ✓Third-party test evidence with every product
- ✓Written specification you can issue to tender
- ✓Supplied and installed across the UK
Get a free project quote
Rating, written specification and budget range within one working day.
Confidential. No cost, no obligation.
Third-party tested
Evidence with every quote
UK manufactured
Made to your sizes
One accountable team
Specify, supply, install
Confidential handling
Details never shared
A supermarket is a shop, a warehouse and a cash office under one roof, and the doors between one part and the next hold the line between them. The sales floor holds the customers, the stock room holds the goods, and the cash office holds the takings, so a door between one part and the next must hold the line between them.
LPS 1175 sets the grade on a supermarket door, and the room behind the leaf decides which category it takes. Issue 8.2, dated September 2024, gives the three categories three, five and ten minutes, named B3, C5 and D10. The entrance takes the lowest of the three, the stock room takes the middle one, and the cash office takes the highest.
The rules for the shared parts of a shop are set out in the fire door regulations retail guide, and the rules for the stores beside the sales floor are set out in the fire door regulations warehouses guide. The store order names every door in the building, with the grade and the lock beside each one, so the door that arrives is the door the room needs.
- LPS 1175 B3 / C5 / D10Forced entry grades to Issue 8.2
- Cash officesWhere the grade rises
- FD30 / FD60Fire periods to EN 1634-1
- One listEvery store door named
Front of store, stock room and delivery bay: one store, three grades
A supermarket splits into three parts, and the grade follows what each part holds. The sales floor feeds the tills, the stock room feeds the shelves, and the delivery bay feeds them both from the yard, so each part takes the doors its work demands.
The sales floor takes the doors the customers pass through all day, and each leaf must open for a shopper with a trolley and shut behind them without a hand on it. The stock room takes the doors the public never sees, and each leaf must hold against the attack the goods behind it invite.
The store writes its schedule before the order goes out, naming every opening and the grade beside it. A leaf with no line on the schedule may arrive for the wrong room, and the wrong leaf on the cash office guards nothing.
The cash office: the room that takes the highest grade
The cash office holds the takings, and the leaf that guards it takes the highest grade on the order. Leaf, frame, fixings and lock are proved together as one doorset, and the test report names each part, so the door that arrives matches the door that was proved.
A cash office leaf takes D10, because it must hold longest, while the stock room beside it takes C5 and the entrance takes B3. The three categories were called SR2, SR3 and SR4 before Issue 8, and the order names the category the product was proved under. A door ordered to LPS 1175 carries LPS 1175 alone, because no published table turns one standard’s rating into another’s.
The cash office takes a lock the manager controls, and the leaf, the frame and the lock are proved together as one doorset, with the report naming each one. What breaks a rating once a door is fitted is named in the keeping an LPS 1175 rating valid guide.
Stock rooms and the delivery bay: where the value waits
The stock room holds the goods the shelves will need next, and the leaf that guards it takes the grade the value behind it demands. A stock room leaf takes C5, because the goods behind it are worth the time it takes to break through, and the leaf must hold long enough for the alarm to be answered.
The delivery bay takes the same care, because the doors at the back of the store face the yard where anyone can walk up to them. A delivery bay leaf takes C5, and the lock on it takes the same key as the stock room, so the staff who work the bay can open both without carrying two keys.
The delivery bay leaf takes a closer that shuts it after every load, because a leaf left open is a door that guards nothing. The closer is set so the leaf comes home quietly after every load, and the pull is checked by opening the leaf and letting it go. Sizes and fitting for closers are worked through in the fire door closers guide.
The front of the store: the leaves customers meet
The front of the store is the leaf every customer passes, and it must open for a shopper with a trolley and shut behind them without a hand on it. The entrance leaf takes B3, because the public passes through it all day, and the leaf must open with one push from whoever reaches it.
The glass in the entrance leaf takes the same proof as the leaf beside it, because a leaf that holds while its pane fails has held nothing. The test report names the bead and the fixings that hold the pane, and the order carries them beside the glass. The fire rated glass cost guide works through what the glass itself costs.
The entrance doors take a panic bar to BS EN 1125, running across at least 60 percent of the leaf, so one push throws the latch for a crowd. The force to open a leaf on the way out stays below 30 N for the first 30 degrees of travel and below 22.5 N beyond, under BS 8300 and Approved Document M.
A store leaf that holds both: fire and forced entry together
One store leaf can carry both proofs at once, because the stock room needs fire held back and an intruder held out. EN 1634-1 writes the fire proof as minutes with letters, E, EW and EI from 30 to 120, and LPS 1175 writes the forced entry proof as B3, C5 and D10. The leaf, the frame and the seals face both tests as one doorset, so the proof for fire and the proof for forced entry sit on the same report.
The period follows the room behind the leaf, because the stock room, the cash office and the sales floor ask different things of the leaf, and the grade follows the value behind it. Minutes run from 30 to 120, and the letters beside the number say what stayed back: flames on their own, flames with some heat, or flames with the heat as well. Smoke seals on the route doors carry a proof to BS EN 1634-3, Sa where the smoke is at room temperature and S200 where it is at 200 degrees. The smoke control doors guide covers how the doors hold smoke back while people move past them.
The gap beside the leaf stays at 4 mm, so the leaf swings without catching and the seal meets the frame all round. Heat near 200 to 250 degrees makes the intumescent seal swell and close the gap the leaf leaves. The fire and security doors dual certification guide works through how two proofs share one doorset.
Locks, readers and the goods-in door: how staff move through the store
The staff route through a supermarket runs from the entrance through the sales floor to the stock room and back, and each leaf on the route opens for staff and stays shut for the public. Each leaf takes a reader beside it, and the list behind the readers names the fobs that open each door. The fire door hardware guide covers the lock the key turns.
The goods-in door takes the deliveries in from the yard, and it takes a leaf wide enough for trolleys and pallets and a lock the staff control. The security door locks guide covers the lock the key turns, and the door entry systems guide covers the readers, releases and wiring beside a leaf.
Before the order goes out, every leaf gets its answer for the night the power fails. The answer sits beside each door on the order, so no leaf is left to guess when it matters most.
The entrance and the checkouts: doors the public passes every day
The checkouts take the doors the customers pass with their trolleys, and each leaf must open for a shopper who has never touched it before. The doors beside the tills take the same care as the entrance, because a leaf that will not open traps the customer behind it.
The doors that guard a shop take the same care with their stores, and the retail security doors guide sets out the doors a shop needs.
The entrance leaf takes the wear of every customer who passes through it, so the hinges, the closer and the seals on the busiest doors belong at the top of the list. A leaf that drags, a closer that has lost its pull, or a seal that has come away from its groove is written beside the door it belongs to, with the part and the day it was found.
The supermarket order: every leaf on one list
The supermarket order is written as one list, with a line for every door in the building and the leaf, the grade, the lock and the closer beside each one, so the door that arrives is the door the sales floor, the stock room and the delivery bay need. A list that names one leaf for the whole store leaves the fitter guessing which room takes which grade, and a leaf in the wrong room guards the wrong thing.
Every leaf, lock, closer and seal on the store is priced from the list before the order goes out, line by line, so the entrance, the cash office and the delivery bay each carry their own figure. The how to specify security doors guide sets out the columns the list needs, and what each step up the scale adds to the price is worked through in the security door cost factors guide.
One day each week the store manager walks the whole estate in a single round, starting at the entrance and ending at the cash office after the stock rooms and the delivery bay. The round opens every leaf, works every lock and watches every closer as the leaf comes back to the frame. Its note stays with the store file, and a leaf that will not close or a lock that will not throw is put right before the next delivery is due. The fire door inspection checklist lists what a visit should cover, and the security door maintenance checklist covers the leaves that must hold fire as well as forced entry.
| Position | Door | Grade | What to check |
|---|---|---|---|
| Entrance | Glazed leaf | LPS 1175 B3 | Leaf, glass, reader |
| Cash office | Steel leaf | LPS 1175 D10 | Leaf, lock, seals |
| Stock room | Steel leaf | LPS 1175 C5 | Leaf, lock, seals |
| Delivery bay | Steel leaf | LPS 1175 C5 | Leaf, closer, lock |
| Plant room | Fire leaf | FD60 | Leaf, seals, gap |
A supermarket door holds only as long as the cash behind it and the stock beside it, so the grade, the period and the lock must all sit on the same list.
What grade should a supermarket door carry?
The grade follows the room behind the leaf: B3, C5 or D10 to LPS 1175, with the cash office taking a higher category than the entrance.
Can one leaf hold fire and forced entry?
Yes, when one leaf, frame and seals face both tests together, the one doorset carries the proof for fire and for forced entry.
Do supermarket doors need access control?
A reader beside each leaf behind the sales floor opens it for staff fobs, so the public stays on the shop side of the door.
What period should a stock room door carry?
FD30 or FD60 to EN 1634-1, with letters beside the minutes naming what the doorset held back. The room behind the leaf decides which period the door takes.
Who checks the supermarket doors?
The store manager walks the round that covers every door, and the record of each visit stays with the store file.
Get a free quote
Related
More in guides for specifiers
Products
One supplier for the whole building envelope
Ready to specify your project?
Free assessment, written specification and test evidence. Reply within one working day.