Certified physical security

ArxBridge
Steel door sample in a security test frame with an assessor in a UK test laboratory

ArxBridge

Master Key Systems

Master key systems for estates and commercial buildings: one key for many doors, staff keys that open only their own, cylinders, key control and the record.

  • ✓Third-party test evidence with every product
  • ✓Written specification you can issue to tender
  • ✓Supplied and installed across the UK
Prefer to talk?+44 7352 267239

Get a free project quote

Rating, written specification and budget range within one working day.

ArxBridge Quote Form

Confidential. No cost, no obligation.

Third-party tested

Evidence with every quote

UK manufactured

Made to your sizes

One accountable team

Specify, supply, install

Confidential handling

Details never shared

A master key system lets one key open many doors while a staff key opens only the doors its holder needs. The estate manager holds the key that opens the whole building, the cleaner holds the key that opens the rooms they clean, and the tenant holds the key that opens only their own flat.

The system is a hierarchy, not a pile of keys. Each door takes a cylinder that answers to its own key and to the keys above it, so the right key opens the right doors and no key opens a door it should not. A system planned on paper first works on the doors, and a system that grows one key at a time stops working.

The doors a keyed system guards are set out in the commercial buildings fire door regulations guide, and the fire door hardware guide covers the grades and the parts behind a working fire door.

  • TS 007 3-starCylinder and handle sets
  • BS EN 1935Hinge grades 13 and 14
  • BS EN 1125Panic hardware for escape routes
  • FD30 / FD60Fire resistance periods tested to EN 1634-1

One key, many doors: how a keyed system is put together

A keyed system starts with the doors, not with the keys. Each door on the estate is listed, the people who need it are named, and the keys are cut to match the list. The master key opens every door on the estate, the sub-master opens the doors on one floor or in one wing, and the individual key opens one door and no other.

The cylinder is the part that reads the key. A cylinder that answers to more than one key is pinned to accept each of them, and the pinning is set when the cylinder is made. A cylinder pinned for three keys cannot be changed by cutting a fourth key, because the pinning is fixed in the metal.

Plan the whole hierarchy before the first cylinder is ordered, because a system extended later has to be re-pinned, and re-pinning a building full of cylinders costs more than planning it once. The how to specify security doors guide sets out the columns a schedule needs, and the keying belongs on one of them.

The hierarchy: who opens which door, and who opens them all

The top of the hierarchy is the grand master key, held by the person who runs the estate. It opens every door, including the plant rooms, the stores and the rooms that hold the keys, and it should be kept in a safe when it is not in use.

Below it sit the sub-master keys, one for each floor, wing or department. A sub-master opens the doors in its own part of the building and no other, so the cleaner for the north wing cannot open the south wing, and the manager of one department cannot open another.

At the bottom sit the individual keys, one for each door or each small group of doors. A member of staff takes the keys for the rooms they use and no more, and a tenant takes the key for their own flat and the shared doors they need. The hotel fire doors guide covers the doors on bedroom corridors and stair cores, where the hierarchy matters most.

Need this specified for your project?Free rating, written specification and budget range within one working day.
Get a free quote

Cylinders and keys: the parts that carry the system

The cylinder is the part that must match the leaf it sits in. A TS 007 3-star set, made of a 1-star cylinder with a 2-star handle or escutcheon, keeps the lock proved, and the cylinder should be chosen for the door it guards, not for the key it takes.

A key that can be copied at any shop is a key that cannot be controlled. A restricted keyway, where blanks are held by the supplier and cut only on the order of the person who runs the estate, keeps the copies in known hands. Ask the supplier who holds the blanks and who may order a copy, and put the answer in the file.

Hinges must match the leaf they carry, because a door that sags on its hinges no longer meets its frame, and a lock that no longer meets its keep is a lock that no longer works. Hinges to BS EN 1935 carry the leaf through 200,000 cycles, with grade 13 rated for 120 kg and grade 14 for 160 kg, so the hinge should be chosen for the weight of the leaf it carries.

Key control: the record that names who holds each key

Key control is the record that names who holds each key, and it matters as much as the cylinders. Every key issued should be written down with the name of the person who holds it, the doors it opens and the date it was given out, so the next manager can see who can open which door.

Check the record every month against the keys in hand. A key issued to a member of staff who has left should be written down as returned or lost, and a key that cannot be found should be treated as a key in the wrong hands, because a missing key is a door left open.

Keep the record in one place, with the person who runs the estate. A record kept on a scrap of paper in a drawer is a record that will be lost, and a record that is lost leaves the estate guessing who holds its keys. The fire door inspection checklist names what each round should look for, and the key record should be checked on the same round.

When a key is lost: the change that follows

A lost key is a door left open until the cylinder is changed. First work out which doors the key opened, then change the cylinders on those doors, because a key that is lost cannot be called back. A master key lost is a building of cylinders to change, and that is the cost of holding the key that opens everything.

Change the cylinder, not the whole lock, where the lock allows it. A cylinder swap takes minutes and leaves the hardware in place, while a lock change takes longer and costs more. The new cylinder should be pinned to the same hierarchy, so the keys above it still work and the keys below it still open only their own doors.

Tell the people who hold the keys above and below the lost one what has changed, because a sub-master that no longer opens a door will be tried at the door, and a door that will not open for its own key will be forced. The security door maintenance checklist covers the doors that must hold both fire and forced entry.

Keys beside the access system: cards, fobs and the override

A keyed system and a card system can share the same doors. The card opens the door for the staff who use it every day, and the key opens the door when the card system fails, because a door that will not open when the power goes is a door that holds people inside.

Give the doors a card or a fob where the traffic is heavy, and keep the key for the override. A fob can be stopped the day a member of staff leaves, while a key that walks out with them stays live until the cylinder is changed, and the live fobs should be checked every month. The security turnstiles guide covers readers, fobs and biometrics in the lane.

Escape doors must still release on alarm, whatever the keying says, so no one is held inside when the alarm sounds. Rooms that fill for the evening need panic hardware to BS EN 1125, a bar across at least 60 percent of the leaf width, and the opening force must stay below 30 N for the first 30 degrees of travel and below 22.5 N beyond, under BS 8300 and Approved Document M. The fire door closers guide covers the sizes and the fitting of the closer that pulls the leaf shut.

The handover pack: what the estate keeps on file

The handover pack holds the keying plan, the record of who holds each key, and the pinning chart that shows which key opens which door. Without the chart, a cylinder that needs changing cannot be re-pinned, and without the record, a key that needs stopping cannot be traced.

Keep the pinning chart away from the keys themselves, because a chart left beside the key cabinet is a map of the building for anyone who finds it. The chart belongs in the file with the person who runs the estate, and a copy in the safe with the grand master key.

The pack should also hold the test reports for the doors the keys guard. A fire door only works when it is shut, and a door that must hold fire takes FD30 or FD60 proved to EN 1634-1, with the period following the fire load behind the door. The fire and security doors dual certification guide works through how the two proofs share one leaf, where a door must hold fire and resist attack at once.

The key plan for the whole estate

Put every door on one list before the order goes out, with the key level, the cylinder and the hardware written beside each position, so the door that turns up is the door that was planned. A list that names one key for the whole estate leaves the fitter to guess which cylinder goes where, and a guess is not a plan.

Go through each quote line by line against the list before ordering. A cylinder left off a quote still has to be bought, and fitting it round a door already in use costs more than ordering it with the door. The security door cost factors guide sets out what each step up the scale adds to the build, and the keeping an LPS 1175 rating valid guide sets out what breaks a rating once a door is fitted.

Keep the key record with the doors from the day they arrive, so the proof is never far from the leaf it belongs to. The plant room door requirements guide covers the doors on the rooms that feed a building, and the loading bay doors guide covers the bays where deliveries arrive and leave.

Key level Opens Held by What to check
Grand master Every door Estate manager Safe, record, chart
Sub-master One floor or wing Department manager Record, return on leaving
Individual One door Member of staff Record, return on leaving
Service Plant rooms Contractor, one day Record, expiry, return
Override Escape doors Fire service access Release, panic bar, closer

A master key system is a hierarchy on paper first, so the keying plan, the cylinders and the record must all sit on the same schedule.

What is a master key system?

A keying hierarchy where one key opens many doors and a staff key opens only the doors its holder needs. The master key opens every door, sub-master keys open one floor or wing, and individual keys open one door.

Who should hold the master key?

One person, the person who runs the estate, and it should be kept in a safe when it is not in use. A master key lost means every cylinder it opened has to be changed.

How are lost keys handled?

Work out which doors the key opened, then change the cylinders on those doors. A cylinder swap takes minutes and leaves the hardware in place, and the new cylinder is pinned to the same hierarchy.

Can keys be copied without permission?

Not where the keyway is restricted. Blanks are held by the supplier and cut only on the order of the person who runs the estate, so the copies stay in known hands.

Do keyed doors still need a fire rating?

Yes, where the door guards an escape route or a compartment wall. The proof is to EN 1634-1, and the period follows the fire load behind the door, FD30 for most rooms and FD60 where the load is heaviest.

Specifying a master key system for an estate?Send the door schedule and the keying hierarchy for a tested door quotation.
Get a free quote

Related

More in guides for specifiers

10 mistakes when specifying certified security doors 10 steps to specify an LPS 1175 door Acceptance and Snagging of a Security Door or Barrier Job Access Control Doors Acoustic Doors: Ratings and Specification After a Forced Entry Attempt: Checking a Security Door Airport Security Doors Anti-Ligature Doors for Mental Health Wards Anti-Ram Bollards Anti-ram gates and barriers: protecting vehicle entrances Arcade Security Doors Explained Automatic Doors Automatic Gates Cost Factors Automatic Vehicle Barriers Ballistic Panels Bank Security Doors Bingo Hall Security Doors Explained Blast doors: glazed vs solid and how they are rated Blast protection window film: what it does and what it cannot do Blast resistant windows: what drives the cost and how to specify them Bollard Cost Factors Explained Bollard regulations in the UK: spacing, height and depth Bookmaker Security Doors Explained Builders Merchant Security Doors Bullet Resistant Glass Cost Factors Bullet resistant glass ratings explained: BR1 to BR7 and SG classes Bullet resistant vs bulletproof glass: what the difference means Buying Security Doors and HVM Through Public Frameworks Car Park Security Doors Explained Car Showroom Security Doors Casino Security Doors Explained CDM 2015 Duties When Security Doors, Shutters or HVM Are Installed Cinema Security Doors Cleanroom Doors Cold Store Doors College Security Doors Commissioning, Handover and the O&M Manual for Security Doors and HVM Communal entrance doors for flats: Secured by Design and what to specify Community Centre Security Doors Control Room Doors Court Security Doors Crash Rated Fences and HVM Fencing Explained Data centre physical security: doors, glazing, HVM and shielding by zone Dental Practice Security Doors Depot Security Doors Explained Door Entry Systems Due Diligence When Selecting Vehicle Security Barriers Emergency Exit Doors EMP Shielding Cost Factors Explained Exhibition Centre Fire Door Rules Exhibition Centre Security Doors Factory Security Doors Faraday cage vs RF shielded room: what a business needs FB4 vs FB6 vs FB7: how to choose a ballistic rating Fire and security doors: how dual certification works Fire Compartmentation Fire Curtains Fire Door Certification Fire Door Closers Explained Fire Door Cost Factors Fire Door Duties of the Accountable Person Fire Door Gaps Fire Door Hardware Explained Fire door inspection checklist for steel and timber doors Fire Door Maintenance Fire Door Regulations Care Homes Fire Door Regulations for A and E Departments Fire Door Regulations for Airports Explained Fire Door Regulations for Bowls Clubs Fire door regulations for commercial buildings in the UK Fire Door Regulations for Dialysis Centres Fire Door Regulations for Hockey Clubs Fire Door Regulations for Hospitals Explained Fire Door Regulations for Offices Explained Fire Door Regulations for Operating Theatres Fire Door Regulations for Retail Explained Fire Door Regulations for Schools Explained Fire Door Regulations for Snooker Clubs Fire Door Regulations for Stadiums Fire Door Regulations for Student Accommodation Fire Door Regulations for Warehouses Fire Door Regulations Leisure Centres Fire Door Regulations Restaurants Fire Door Remediation Programme for Housing Providers Fire Door Rules for Badminton Clubs Fire Door Rules for Bingo Halls Fire Door Rules for Bookmakers Fire Door Rules for Bowling Alleys Fire Door Rules for Car Parks Fire Door Rules for Car Showrooms Fire Door Rules for Cinemas Fire Door Rules for Climbing Centres Fire Door Rules for Colleges Fire Door Rules for Community Centres Fire Door Rules for Cricket Clubs Fire Door Rules for Dental Practices Fire Door Rules for Depots Explained Fire Door Rules for Golf Clubs Fire Door Rules for GP Surgeries Fire Door Rules for Gyms Explained Fire Door Rules for Ice Rinks Fire Door Rules for Maternity Units Fire Door Rules for Mental Health Units Fire Door Rules for Museums Fire Door Rules for Oncology Units Fire Door Rules for Opticians Fire Door Rules for Pawnbrokers Fire Door Rules for Petrol Stations Fire Door Rules for Pharmacies Fire Door Rules for Ports Fire Door Rules for Post Offices Fire Door Rules for Prisons Fire Door Rules for Rehabilitation Centres Fire Door Rules for Self Storage Fire Door Rules for Shopping Centres Fire Door Rules for Squash Clubs Fire Door Rules for Supermarkets Fire Door Rules for Swimming Pools Fire Door Rules for Tennis Clubs Fire Door Rules for Theatres Fire Door Rules for UK Arcades Fire Door Rules for UK Casinos Fire Door Rules for UK Hospices Fire Door Rules for Walk-in Centres Fire Door Signage Fire Door Vision Panels Fire Doors and Gateway 2 in Higher-Risk Buildings Fire Rated Glass Cost Explained Fire Rated Sliding Doors Explained Fire Rated Windows Cost Factors Fire Rated Windows Explained Fire Safety Enforcement Notices and Fire Doors: What the Responsible Person Must Do Flat Entrance Doors: PAS 24 and Fire Rated Forced Entry vs Ballistic vs Blast: Which Rating a Site Needs Garage Security Doors Explained Gate Automation Explained Golden Thread Records for Fire Doors GP Surgery Security Doors Explained Gym Security Doors Explained High Speed Doors HMO Fire Doors Hospice Security Doors Explained Hospital Security Doors: Wards, A&E, Plant Hospital Security Gates Hotel Fire Doors Hotel Security Doors How to choose HVM bollards: fixed, shallow mount, removable and automatic How to keep an LPS 1175 door rating valid after installation How to Specify Fire Doors in a Housing Tender How to specify security doors: a checklist for architects How to Verify a Secured by Design Listing How to Verify an LPS 1175 Certificate on Red Book Live How to Write an Operational Requirement for Physical Security HVM planters and street furniture: protection that blends in In-Service Care of Vehicle Security Barriers Installation Handover: LPS 1175 Doors and PAS 68 Barriers Intumescent Seals ISO 16933 explained: EXV and SB classes and hazard ratings ISO 22343 vehicle security barriers explained Keeping a Dual-Certified Fire and Security Door Valid in Service Laboratory Security Doors Layered Security for a Site: Deter, Detect, Delay, Mitigate, Respond Lead Times and Programme Risks for LPS 1175 Doors Leisure Centre Security Doors Library Security Doors Listed Building Fire Doors Loading Bay Doors Explained Lockdown and Access Control Hardware on an LPS 1175 Door LPS 1175 Gates and Grilles Explained LPS 1175 Issue 8 explained: from SR1 to SR8 to A1 to H20 LPS 1175 Roller Shutters LPS 1175 vs ASTM F2781 and Other US Ratings Explained LPS 1175 vs EN 1627: how UK and European burglar resistance ratings compare LPS 1175 vs PAS 24: which security standard does your door need? LPS 1175 Windows and Walling Explained Martyn’s Law and Places of Worship: What a Buyer Checks for Doors and Entry Control Martyn’s Law Enhanced Tier: Physical Measures and the Specifier Brief Martyn’s Law Standard Tier: Procedures, Doors and Shutters Martyn’s Law Timeline and the SIA Regulator Martyn’s Law: what premises must do and which physical measures to consider MRI and RF shielded rooms: how they work and what to specify Museum Security Doors NPSA Catalogue of Security Equipment (CSE) Explained NPSA Forced Entry and Blast Guidance for Government Sites NPSA Guidance on Lockdown and Marauding Attack: What It Asks of Doors and Entrances Office Security Doors Optician Security Doors Explained Panic Hardware PAS 24 requirements for doors and windows explained PAS 68 Bollard Foundations Explained PAS 68 bollards: ratings, spacing and cost factors PAS 68 vs IWA 14 vs ISO 22343: hostile vehicle mitigation standards explained Pawnbroker Security Doors Explained Pedestrian Gates Petrol Station Security Doors Pharmacy Security Doors Planning Permission for Security Shutters, Gates and Bollards on Commercial Premises Plant room doors: fire, security and ventilation requirements Plant Room Fire Doors Port Security Doors Post Office Security Doors Explained Powder coating vs galvanising vs paint for steel Preliminary Market Engagement for Security Doors and HVM Prison Security Doors Programming a Security Door and Barrier Package on a Live Site Public-Sector Tender Response Checklist for Security Door and HVM Supply Reading a PAS 24 and SBD Door Test Report Regulation 38 Fire Safety Information at Handover for Fire-Rated Security Doorsets Replacing Security Doors in an Occupied Building Restaurant Security Doors Retail Security Doors Revolving Doors RF shielding standards and how shielded rooms are tested Rising Bollard Cost Factors Road Blocker Cost Factors Explained Road Blockers Explained Roller Shutter Cost Factors: What Drives the Price Roller shutter regulations in the UK: safety and maintenance Safe room and panic room doors: specification basics Safety Duties for Powered Doors, Gates and Barriers on Commercial Sites School Security Doors Sectional Doors Secured by Design explained: is it mandatory for doors? Secured by Design vs NPSA vs LPCB: Which One You Need Security Door Locks Security Door Maintenance Checklist Security Doors and Access for Everyone: What Approved Document M Asks Security Doors for A and E Departments Security Doors for Badminton Clubs Security Doors for Bowling Alleys Security Doors for Bowls Clubs Security Doors for Climbing Centres Security Doors for Cricket Clubs Security Doors for Dialysis Centres Security Doors for Golf Clubs Security Doors for Hockey Clubs Security Doors for Ice Rinks Security Doors for Maternity Units Security Doors for Mental Health Units Security Doors for Oncology Units Security Doors for Operating Theatres Security Doors for Rehabilitation Centres Security Doors for Snooker Clubs Security Doors for Squash Clubs Security Doors for Swimming Pools Security Doors for Tennis Clubs Security Doors for Walk-in Centres Security Doors West Midlands Explained Security Fencing Security Gates Cost Factors Explained Security shutters vs high performance roller doors Security shutters vs retractable grilles: which suits retail and commercial openings? Security Turnstiles Explained Security Window Film Security Windows for Schools Explained Self Storage Security Doors Server Room Doors Explained Shopping Centre Security Doors Smoke Control Doors Explained Smoke Curtains Specification Mistakes When Mixing LPS 1175, PAS 24 and SBD in One Tender SR2 vs SR3 vs SR4 security doors: choosing the right LPS 1175 level Stadium Security Doors Steel Door Frames Steel vs aluminium security doors: strength, ratings and looks Steel vs timber fire doors: which suits your building? Student Accommodation Security Doors Substation doors: security, ventilation and specification Supermarket Security Doors Telescopic Bollards Tender Evaluation Criteria and Scoring for Security Doors and HVM The Scope of a Maintenance Contract for Security Doors and Barriers Theatre Security Doors Thermal and Weather Performance of External Security Doorsets Thermally broken steel security doors: U-values and certification Traffic Calming as Hostile Vehicle Mitigation Transport hub security requirements Turnstile Cost Factors Explained Turnstile vs speed gate vs security portal: choosing entrance control Types of security doors for commercial buildings University Security Doors Explained Vehicle Dynamics Assessment: What It Tells the Buyer Before a Barrier Is Specified Warehouse Security Doors Explained Warehouse Security Gates Warranty, Defects Liability and Guarantees for Security Doors and Barriers What affects the cost of a bullet resistant door What affects the cost of a high-security door in the UK Window Security Bars View all →

Products

One supplier for the whole building envelope

Ready to specify your project?

Free assessment, written specification and test evidence. Reply within one working day.