ArxBridge
Control Room Doors
Control room doors: rated doorsets for operations and monitoring rooms, with access control, fire proof, glazing and one schedule for the whole suite.
- ✓Third-party test evidence with every product
- ✓Written specification you can issue to tender
- ✓Supplied and installed across the UK
Get a free project quote
Rating, written specification and budget range within one working day.
Confidential. No cost, no obligation.
Third-party tested
Evidence with every quote
UK manufactured
Made to your sizes
One accountable team
Specify, supply, install
Confidential handling
Details never shared
A control room door guards the people who watch the building. Behind it sit the screens, the radios and the staff who answer the alarm, and a door that fails on either side leaves the room open to the wrong person, or shuts the right person out when the alarm sounds.
The order starts with the room, not with the leaf. A monitoring room that runs through the night asks for a different door from a plant room that holds the servers, and a corridor door that staff pass a hundred times a day asks for a different lock from the door on the room where the keys are kept.
One list should hold every door in the suite, with each one named plainly, so the right door lands on the right opening. The server room doors guide covers the doors on the rooms that hold the machines, and the data centre physical security by zone guide sets out doors zone by zone in a building that must stay controlled.
- LPS 1175 B3 / C5 / D10Forced entry ratings, three, five and ten minutes
- FD30 / FD60Fire resistance periods tested to EN 1634-1
- TS 007 3-starCylinder and handle sets
- BS EN 1125Panic hardware for escape routes
Where a control room puts its doors: the suite, the plant and the corridor
The operations room is the heart of the suite, where staff watch the screens and take the calls. Its door must open for the duty team and stay shut for everyone else, because the screens behind it show the whole building, and a stranger at the door can see what the room is watching.
Behind the operations room sit the plant rooms, the server rooms and the stores that feed the building. The doors on those rooms take a higher rating than the corridor doors, because the equipment behind them is worth more than the corridor, and the rating on the order should match what the room holds.
The corridor doors link the suite to the rest of the building, and they must take the daily traffic without failing. A door that is opened a hundred times a day needs hinges and a closer chosen for that duty, and the data centres sector page sets out the buildings these doors guard.
The door that guards the operations room: rating the leaf by the threat
Forced entry is proved to LPS 1175, with B3 holding three minutes against category B tools, C5 holding five minutes against category C tools and D10 holding ten minutes against category D tools, all under Issue 8.2, dated September 2024. The rating on the order should match the value of what the room holds, not the door the catalogue shows first.
A control room that guards a whole estate takes a higher grade than a room that watches one floor, because the threat follows the building, not the door. The grades in full are set out on our LPS 1175 page.
Where the room empties at night, LPS 2081 adds a stealth rating, with SRA holding one minute and SRB holding three minutes against an attack that must not be heard. The keeping an LPS 1175 rating valid guide sets out what breaks a rating once the door is fitted.
Access control and the audit trail: who passed, and when
Give the control room a card or a fob, not a key. A fob can be stopped the day a member of staff leaves, while a key that walks out with them stays live until the lock is changed, and the list of who holds each fob belongs on the file beside the door.
Keep the control room on the same access system as the rest of the site, so a single card opens the suite, the plant rooms and the yard, and a card that is stopped dies everywhere at once. Readers, fobs and biometrics in the lane are covered in our security turnstiles guide.
The audit trail matters as much as the lock, because the record shows who opened the door and when. After an incident, the trail is the first thing the duty manager reads, so the system that keeps it belongs on the order beside the reader.
Glazing and vision: seeing the room without opening the door
A vision panel in the control room door lets the duty team see who is outside before the door opens, and a glazed screen beside it lets them watch the corridor without leaving the room. The glass in both must carry its own proof, because an untested pane is a gap in the door, whatever the leaf around it can hold.
The glass in them is proved to EN 356, with the top classes set by axe blows: 30 to 50 for P6B, 51 to 70 for P7B, and 70 or more for P8B. A control room that holds the keys to the building takes a higher class than a corridor door, so the class follows the risk the room faces.
Glazing that must hold fire is proved to EN 1634-1, with FD30 or FD60 naming the period and the letters E, EW or EI naming what the furnace measured. Order the frame, the beads and the fixings on the same line as the glass, so the window that arrives is the one that was tested. Windows that share the wall with the control room take the same proof as the door beside them, and the fire rated windows guide sets out the periods for those windows.
Fire and security on one leaf: the two proofs together
A control room door that must hold fire and resist attack carries two proofs on the same leaf. Fire is proved to EN 1634-1 and forced entry to LPS 1175, and each proof must name the same leaf, frame and hardware, because a test that names only the leaf leaves the frame and the fixings unproved.
Most control room doors carry thirty minutes, while doors on a compartment wall or a room with a heavier fire load carry sixty, and a door on a smoke path takes FD30S, with the seal proved to BS EN 1634-3, to Sa for smoke at room temperature and S200 for smoke at 200 degrees Celsius.
The fire and security doors dual certification guide works through how the two proofs share one leaf. The closer on the door must pull the leaf shut every time, and the fire door closers guide covers the sizes and the fitting, while the fire door hardware guide covers the grades and the parts behind a working fire door.
Sound and the door that must keep the room quiet
A control room runs on talk, on radios and on alarms, so the door must keep the noise of the corridor out and the talk of the room in. A leaf that lets sound through leaves the operators shouting over the corridor, and a door that seals the room keeps the calls clear.
Sound is measured as Rw, the weighted sound reduction index in decibels, and the number on the order should name the quiet the room needs. The whole doorset is tested as one, leaf, frame and seals together, because a leaf that is quiet in a frame that leaks is no quiet door at all.
One doorset can carry three proofs at once, acoustic, fire and security, and each is proved on its own test. A door that must hold fire takes FD30 or FD60 proved to EN 1634-1, and a door that must resist attack takes B3, C5 or D10 proved to LPS 1175, and the order should name all three.
Fail safe on power loss: the door that must still open
The control room door must open when the power goes, because the people inside must be able to leave and the people outside must be able to get in. A lock that needs power to open is no lock at all in a blackout, so the release must work without power as well as with it.
Fail safe means the door releases when the power fails, and fail secure means it stays locked. A control room door that guards people takes fail safe, so no one is held inside when the lights go out, and the release is written into the order beside the reader. Doors that must hold smoke back while people move past them are covered in the smoke control doors guide.
Rooms that fill for an incident need panic hardware to BS EN 1125, a bar across at least 60 percent of the leaf width, because a crowd that cannot open the door in a fire is a crowd held inside. The opening force must stay below 30 N for the first 30 degrees of travel and below 22.5 N beyond, under BS 8300 and Approved Document M, so anyone in the room can push the door open.
One schedule for the whole control suite: every door on one line
Put the order together as one list with a line for every door in the suite, naming the position, the fire period, the forced entry rating, the glazing and the hardware beside each one, so the door that arrives matches the door that was proved.
Read every quote against the list before anything is ordered. Parts left off a quote do not vanish; they turn up later, fitted round a door that is already in use, at a higher cost than ordering them with the door. The security door cost factors guide works through what each step up the scale adds, and the how to specify security doors guide runs through the same discipline column by column.
Put the test reports in the file with the doors on the day they arrive, so the proof stays with the leaf it belongs to. The fire door inspection checklist names what each round should look for, and the security door maintenance checklist covers the doors that must hold both fire and forced entry.
| Position | Door | Rating | What to check |
|---|---|---|---|
| Operations room | Glazed security door | LPS 1175 C5 | Glass, frame, reader |
| Plant room | Solid security door | LPS 1175 B3 | Lock, hinges, closer |
| Server room | Fire and security door | FD30 + B3 | Seals, reader, release |
| Escape route | Fire door | FD30S | Seals, closer, release |
| Corridor | Security door | LPS 1175 B3 | Closer, seals, latch |
A control room door must guard the people who watch the building, so the rating, the credential and the release must all sit on the same schedule.
What rating do control room doors need?
It depends on the room. LPS 1175 grades forced entry, with B3, C5 and D10 naming three, five and ten minutes, and EN 1634-1 proves the fire side, with FD30 or FD60 naming the period.
Who may open a control room door?
Only the staff the system knows. A card or a fob opens the door for the duty team, and a fob that has been stopped must stop working everywhere at once.
Do control room doors need a fire rating?
Yes, where the door guards an escape route or sits in a compartment wall. The proof is to EN 1634-1, leaf, frame and fixings together, and the period follows the fire load behind the door.
What happens to the door when the power goes?
It must still open. A fail safe release lets everyone out without power, and the release is checked on the inspection round.
Who checks control room doors?
The duty manager walks the suite on the routine the site keeps. Each round looks at the closers, the seals, the locks and the readers, and each fault goes on the record the day it is found.