ArxBridge
Stadium Security Doors
Stadium security doors: rated doors for stands, concourses, hospitality and back of house, with the vehicle line and one schedule for the venue.
- ✓Third-party test evidence with every product
- ✓Written specification you can issue to tender
- ✓Supplied and installed across the UK
Get a free project quote
Rating, written specification and budget range within one working day.
Confidential. No cost, no obligation.
Third-party tested
Evidence with every quote
UK manufactured
Made to your sizes
One accountable team
Specify, supply, install
Confidential handling
Details never shared
A stadium fills in an hour and empties in minutes, and the doors on its boundary decide who gets in and how fast they leave. Tens of thousands of supporters pass through the turnstiles, hospitality guests arrive through separate entrances, staff and players use doors the public never sees, and each door has to hold against attack while letting a crowd move.
The order comes from the venue, not from one door. A turnstile line takes the crowd, a hospitality entrance takes guests, a players tunnel takes the teams and a service yard takes deliveries, and each door needs a rating, a control and hardware to fit it.
The rating, the access control, the vehicle line and the records sit inside one schedule, and an order that names them plainly gets the right doors on the right openings. Our security turnstiles guide covers readers, fobs and biometrics in the lane, and the public spaces sector page covers the buildings the doors protect.
- LPS 1175 B3 / C5 / D10Forced entry ratings, three, five and ten minutes
- ISO 22343-1Vehicle security barrier ratings
- BS EN 1125Panic hardware for doors serving more than 60 people
- Martyn’s LawEnhanced tier for premises holding 800 or more
Stands, concourses and the turnstile line: where a stadium puts its security doors
A stadium divides into parts that meet the crowd in different ways, and each part puts its doors in a different place. The turnstile line meets supporters on foot, the concourse moves them to their seats, the hospitality areas meet guests behind separate doors, and the service yard meets deliveries and team coaches.
Every one of those parts has doors that must hold against attack and doors that must open for a crowd, and the two duties sit on the same schedule. A door that holds against a forced entry attempt but traps a stand full of supporters inside has failed its other duty, and a door that opens freely but lets any stranger into the players tunnel has failed its first.
Walk the venue and note every door a person or a vehicle can reach, then set each one by the attack it could face. A staffed main entrance faces less risk than a rear gate onto a road nobody watches after a night match, so the rating follows the door, not the stadium.
The turnstile line and the doors behind it: sorting a crowd on the way in
Turnstiles sort a crowd, and the doors behind them hold the line when the turnstiles stop. Supporters arrive in waves before kick-off, tickets are checked at the lane, and a failed door leaves the crowd outside.
A door on the turnstile line must close behind the person who passes through, and a door left standing open is no door at all. A closer or a motor that pulls the leaf shut belongs on the schedule beside the door, and the inspection round should look for the door that no longer shuts on its own.
Every lane on the way in must open freely on the way out when the alarm sounds, so the release on a turnstile or a speed gate belongs on the inspection round beside the reader. Test the release every round, because a lane that stays locked in an evacuation has failed the one job it was fitted for. The turnstile versus speed gate versus portal guide works through which lane suits which entrance.
Reading the rating on a stadium order: B3, C5 and D10
Under LPS 1175 the rating on a doorset names the tool set it stood against and the time it stood for. Three minutes against light hand tools is B3, five minutes against heavier hand tools is C5, and ten minutes against heavy tools is D10. Issue 8.2, dated September 2024, carries those labels, and older drawings still show SR2, SR3 and SR4 for the same three ratings, in the same order.
The rating follows the door, not the building. A hospitality entrance that faces a quiet street takes a lower rating than a rear door onto an unlit service road, and a door into the control room takes the highest rating on the site, because the room behind it runs the venue. The forced entry ratings are set out in full on our LPS 1175 page, and the two routes are compared in our LPS 1175 versus PAS 24 guide.
A stadium door can carry a fire period and a forced entry rating together, but only where one doorset has been tested for both jobs. The EN 1634-1 classification proves the fire side and the LPS 1175 or PAS 24 rating proves the security side, and each proof must name the doorset that will be fitted, because a door with one proof has proved one job only. How the two proofs sit on one doorset is worked through in our dual certification guide.
The concourse doors that hold a crowd and release it
A concourse door works in two directions at once. Before the match it lets supporters through to their seats, and after the final whistle it must empty a stand in minutes, so the leaf must open under a crowd leaning on it.
Any door that serves more than 60 people takes panic hardware to BS EN 1125, and the bar on it must run across at least 60 percent of the leaf and release in one push. Fit the bar to the leaf it was tested with, because a bar on an untested leaf leaves the doorset with no proven rating at all.
The force needed to open a concourse door is capped by BS 8300 and Approved Document M, below 30 N through the first 30 degrees and below 22.5 N beyond that, so a closer set too strong puts the door outside the rules and a supporter carrying a child or using a walking stick cannot open it. Closer power sizes come from BS EN 1154, and no fire door takes less than EN 3. Our fire door hardware guide covers the grades and the parts that make a fire door work, and the fire door closers guide lists the power sizes and the adjustments that keep a closer inside the rules.
The turnstile line first: sorting a crowd before the door
A crowd is sorted at the turnstile line before it reaches the doors, and the doors behind the line must open for the people the turnstiles let through. The turnstile sorts the crowd on the way in, and the concourse doors take the flow that follows, so the doors must open with a light push and shut behind the last person through.
Concourse doors must hold a crowd and release it, and the two jobs ask for different proofs. The leaf must hold against the pressure of a crowd leaning on it, and it must still open the moment the alarm sounds, so the panic hardware and the closer belong on the same line as the leaf. The bar that releases the crowd is proved to BS EN 1125, taking a bar across at least 60 percent of the leaf width, and it is the hardware for a room that holds more than 60 people.
Whether the bar works for everyone in the ground comes down to the force it takes to open the door. The force must stay below 30 N for the first 30 degrees of travel and below 22.5 N beyond, under BS 8300 and Approved Document M, so a child or an older supporter can push the leaf open with one hand.
The grade on a stadium order follows the room the door guards, and forced entry is proved to LPS 1175, with B3, C5 and D10 holding three, five and ten minutes against the tool sets for their categories, all under Issue 8.2, dated September 2024.
Outside the ground: the gates and bollards on the approach
The rooms the public never sees take a different door from the concourse, because the stores and the plant behind them hold a heavier fire load. A hospitality door must welcome guests and still resist a person who tries to force it, while a back of house door guards the rooms that feed the ground. The period follows the fire load behind the door, so most rooms take FD30 and the heaviest loads take FD60.
Outside the ground, the approach takes gates and bollards that close the line a vehicle could drive through. The rating is proved to ISO 22343-1, which supersedes PAS 68:2013, with test vehicles from a 1,500 kg car to a 30,000 kg truck at 48, 64 or 80 km/h, and the order should name the rating the approach could bring. The spacing on the line follows ProtectUK, with no more than 1,200 mm clear between bollards and a minimum height of 500 mm.
The enhanced tier and the security plan set the duties a stadium carries, and the doors must prove they can empty the ground. The fire strategy must show how the building empties and how the doors release, and the schedule should name the rating, the reader and the release beside every door, so the door that arrives is the door that was tested.
| Position | Door | Rating | What to check |
|---|---|---|---|
| Turnstile line | Concourse door | LPS 1175 B3 | Lock, closer, release |
| Concourse | Panic bar door | BS EN 1125 | Bar, closer, force |
| Hospitality | Glazed fire door | FD30 | Glass, seals, closer |
| Approach gate | Vehicle gate | ISO 22343-1 | Rating, release, motor |
Put the rating, the bar and the release on the same line as every stadium door on the order, so the leaf that arrives matches the leaf that was tested. The lanes and readers at the staff entrance are covered in our security turnstiles guide, and the rated options for the gate line are covered in our anti-ram gates and barriers guide. The ratings in full are set out in our ISO 22343 vehicle security barriers guide, and the periods for the shared parts of a public building are set out in our commercial buildings fire door regulations guide.
Hospitality areas and back of house: the doors the public never sees
The rooms behind the public face carry their own risks. A hospitality suite door needs a lock that keeps strangers out of the boxes, a kitchen door needs a closer that survives heat and steam through a match day, and a plant room door needs FD60 and a closer strong enough to shut a heavy leaf against the draught.
Deliveries come in through the back of the ground, so the bay door and the personnel door beside it belong on the same schedule as the concourse doors. Nobody should have to lift a shutter to walk out, so the personnel door goes in the same order as the shutter. Bay doors in full are covered in our loading bay doors guide.
Staff, players and officials pass through doors the public never sees, and those doors take a lock that resists attack from the corridor. A thumb turn on the inside lets a person leave without a key, and a cylinder that meets TS 007, a 1-star cylinder with a 2-star handle or escutcheon giving a 3-star set, resists attack from the outside.
The vehicle line outside the ground: gates, bollards and the approach
A vehicle barrier earns its ISO 22343-1 rating in a live test, with a vehicle driven at it and the result written into one string. Cars from 1,500 kg up to trucks of 30,000 kg are driven at 48, 64 or 80 km/h, and the string records the vehicle class, the speed, the angle and the penetration, so a rating such as V/7500[N3]/80/90:0/0 can be written straight onto the schedule for the approach.
Vehicle ratings moved on from PAS 68:2013, and ISO 22343-1:2023 is the standard a schedule should name now. A line that still asks for PAS 68 asks for a rating no test house issues, so write the current standard beside each barrier and the rating beside the standard. The ratings in full are in our ISO 22343 vehicle security barriers guide, and the change from PAS 68 and IWA 14-1 to the current standard is worked through in our PAS 68 bollards guide.
The gap beside a barrier and the height of the barrier both belong on the schedule, because ProtectUK guidance puts a 1,200 mm cap on the clear gap and a 500 mm floor under the height. Leave a wider gap and a vehicle slips past the barrier; fit a lower barrier and a vehicle climbs it. The hostile vehicle mitigation page covers the line in full, and our anti-ram gates and barriers guide works through the options, while our road blockers guide covers the blockers that rise from the road.
The enhanced tier and the security plan: duties a stadium carries
Every stadium falls under Martyn’s Law, and the tier follows the crowd it holds. Premises holding 200 to 799 people sit in the standard tier, and premises holding 800 or more sit in the enhanced tier, so a stadium is an enhanced tier premises. The law reached Royal Assent in April 2025, go-live is expected in spring 2027, and the Security Industry Authority regulates the scheme.
The security plan for the venue should name the doors beside the measures they carry. A door that holds against attack, a gate that releases on alarm and a barrier that stops a vehicle each belong on the same plan, with the rating beside each one, so the next operator can see each door’s duty.
Our Martyn’s Law guide sets out the tiers and what each one asks of a building, and the Martyn’s Law standards page sets out the law itself.
Ordering for the whole venue: one schedule, one set of evidence
Build the enquiry as a specification, with one line for every door on the venue. Each line names the position, the door type, the forced entry rating, the fire period, the access control and the automation, and the leaf, the frame, the fixings and the hardware as one assembly. Where a door must resist a vehicle as well, ask for the rating on the whole line, not on the leaf alone.
Have the test report, the classification and the hardware schedule travel with the doors, and file them the day the doors arrive. The handover pack should name the inspection routine the venue will follow, so the record covers the whole life of the line.
| Position | Door | Rating | What to check |
|---|---|---|---|
| Turnstile line | Pedestrian door | LPS 1175 B3 | Closer, reader, self-closing |
| Concourse escape route | Fire and security doorset | B3, FD30 | Panic hardware, seals |
| Control room | Security door | LPS 1175 D10 | Lock, hinges, fixings |
| Hospitality entrance | Security door | LPS 1175 C5 | Lock, closer, reader |
| Vehicle approach | Bollards and barriers | ISO 22343-1 | Fixings, spacing, height |
A stadium door guards a crowd on one side and a rating on the other, so the forced entry rating, the release on alarm and the vehicle line must all sit on the same schedule.
What security rating do stadium doors need?
The venue decides, by the attack each door could face. A turnstile line door often takes B3, a hospitality door takes C5, and a control room door takes D10, all to LPS 1175.
Can one stadium doorset hold a fire rating and a security rating?
Yes, where the doorset is tested for both. The fire proof is a classification to EN 1634-1 and the forced entry proof a rating to LPS 1175 or PAS 24, and both must name the doorset that will be fitted.
Do stadium turnstiles need to release on alarm?
Yes. Turnstiles and speed gates sit on the way in, not on the way out, and they must release when the alarm sounds so the crowd can leave.
What vehicle rating does a stadium approach need?
The venue decides, by the vehicle the line must stop. ISO 22343-1 tests barriers against vehicles from a 1,500 kg car to a 30,000 kg truck, at 48, 64 or 80 km/h.
Who checks stadium security doors?
The venue team, on the routine the security plan and the fire strategy set. Each record names the door, the fault, the repair and the date.
Get a free quote
Related
More in guides for specifiers
Products
One supplier for the whole building envelope
Ready to specify your project?
Free assessment, written specification and test evidence. Reply within one working day.