ArxBridge
Security Windows for Schools Explained
School windows that must hold fire, resist forced entry and vandalism, and still let light and air in: one tested assembly, from classroom to corridor.
- ✓Third-party test evidence with every product
- ✓Written specification you can issue to tender
- ✓Supplied and installed across the UK
Get a free project quote
Rating, written specification and budget range within one working day.
Confidential. No cost, no obligation.
Third-party tested
Evidence with every quote
UK manufactured
Made to your sizes
One accountable team
Specify, supply, install
Confidential handling
Details never shared
A school window has to do more than let light in. It must hold fire long enough for a corridor of children to leave, resist a forced entry from outside, stand up to daily knocks from inside, and still open for air on a warm afternoon. A window that does one of those jobs and fails another has not done the job it was bought for, and a school that orders windows one job at a time will end up with windows that fail in different ways in different rooms.
The answer is one tested assembly for each opening: glass, frame, beads, seals and fixings tested together, with the evidence naming all of them. A pane that carries a fire class in one frame carries no rating at all in a different frame, because the test never covered that combination. The same rule holds for security: a rating belongs to the complete tested assembly, not to the glass alone. Our fire rated windows guide sets out how glass, frame and beads are tested together, and our schools sector page covers the doors and gates that guard the same buildings.
The sections below work through the jobs one by one: fire, forced entry and vandalism, escape, safeguarding, the frame that holds the glass, the rooms that need more, and the order itself. Our education sector page covers the buildings a school estate holds, and our fire door regulations for schools guide covers the doors that stand beside these windows in the same corridors.
- EN 1627Resistance classes RC1 to RC6 for windows, doors and shutters
- EI 140 / 180CTemperature rise limits on the safe side of a fire window
- LPS 1270Security glazing standard for windows and screens
- BS EN 1634-1Fire resistance test for doors and windows
What a school window must do: light, air, escape and resistance
Classrooms need daylight. Children learn better in rooms with natural light, and a classroom with small, high windows that admit little light is a classroom that needs electric light all day. At the same time the window must open for air, because a classroom full of children warms quickly and stale air makes concentration harder. Light and air are the first two jobs, and they are the jobs that pull against the other two: a window that opens wide for air is a window that can be climbed through, and a window that admits light through a large pane is a window with a large pane to break.
The specification that serves a school names all four jobs for each opening. A ground floor classroom window needs a security rating and a restrictor that limits how far it opens. A first floor window needs the same rating where it can be reached from a flat roof, a canopy or a low wall. A corridor window needs a fire rating where the corridor is a protected route. A library window needs a quiet closer and a pane that holds the compartment line. Write the schedule first, one line per opening, then order against it, so every window is bought for the opening it stands in.
Fire rated glass in a classroom: E, EW and EI
A fire rating to EN 1634-1 tests flame and heat, and the letters name what the window holds back. E holds back flame and hot gases. EW holds back flame, hot gases and some radiant heat. EI holds back flame, hot gases and heat, with a limit on temperature rise on the safe side: an average of 140 degrees Celsius and a maximum of 180 degrees Celsius. Escape routes usually need EI because children pass close to the window, and a pane that lets heat through can stop an escape even while it holds back flame.
The rating belongs to the window as tested: glass, frame, beads and seals together. A window rated EI30 in a 60 minute wall gives a 30 minute opening, and a window rated EI60 in a 30 minute wall gives a 30 minute opening too. The wall and the window are one decision, and the fire strategy names the period for each opening. Our fire rated glazed doors page covers the same letters on a doorset, and our fire rated glass cost guide covers the glass behind the order in factors-only form.
Smoke needs its own evidence. A fire rating to EN 1634-1 tests flame and heat, and smoke passes through a cold gap long before heat reaches the seals. Where the fire strategy asks for smoke control, the window needs a smoke rating to BS EN 1634-3, Sa or S200. A fire rating on its own does not prove smoke control, so ask for the smoke evidence by name.
Forced entry and vandalism: the rating behind the glass
A school window must resist two kinds of attack: a forced entry from outside, and vandalism from inside and outside. The two are not the same. A forced entry is a deliberate attempt to get in, with tools and time. Vandalism is a thrown stone, a kick, or a chair pushed through a pane by a pupil who is angry or bored. A window that resists a forced entry may still fail under a single heavy impact, and a window that resists impact may still fail under a sustained attack with tools.
EN 1627 sets resistance classes RC1 to RC6 for windows, doors and shutters, and the class names the tools and the time the assembly resists. LPS 1270 is the security glazing standard for windows and screens, and it rates the glazing itself. The class belongs to the complete tested assembly, not to the pane alone, so a rated pane in an untested frame is not a rated window. Ask for the test report, not the class alone, and ask for the exact window, its frame detail and its configuration.
Ground floor windows need the most. A window at ground level can be reached by anyone walking past the building, and it can be attacked without a ladder and without being seen from inside. A window on an upper floor needs the same rating where it can be reached from a flat roof, a canopy, a low wall or a climbing frame. Walk the building from outside and note every window a person can reach, then rate those windows for the attack they could face.
Opening windows and the escape route
An openable window has a sash, hinges and a handle, so its rating rests on the sash being closed when fire breaks out. A sash that is left open has no fire performance at all, whatever its certificate says. A window held open for air needs a release that closes it when the alarm sounds, just as a fire door held open needs a hold-open device to BS EN 1155 that releases the door when the alarm sounds.
Restrictors limit how far a window opens, and they serve two jobs at once: they stop a child climbing out, and they stop an intruder climbing in. A restrictor that can be undone by a child is a restrictor that will be undone, so the release should need a key or a tool that staff hold. Check the restrictor at every inspection, and write down that it worked. A window that opens wide for air in a classroom where small children sit needs a restrictor that holds.
Escape windows need their own check. A window that serves as an escape route must open in one action, without a key and without a tool, and the opening must be large enough for the people who will use it. A window that needs a key to open is a window that traps the children behind it. The fire risk assessment names which windows are escape windows, and the routine should check them as often as the doors.
Safeguarding: who can see in, who can get in
Safeguarding shapes the glass as much as the frame. A classroom window lets a teacher see the corridor and lets the corridor see the classroom, and that visibility is part of how a school keeps children safe. A window with a glazed panel lets staff see whether a room is occupied before opening the door, and lets children see whether the corridor is clear before they leave. The glass must carry the same fire rating as the frame where the fire strategy asks for it, with beads and seals tested as part of the assembly.
Visibility cuts both ways. A ground floor window that lets staff see out also lets a stranger see in, and a window beside an entrance lets a visitor watch the corridor before they are admitted. Obscured glass, a high sill, or a window that starts above head height can keep the light while cutting the view in, and the choice should be made room by room with the safeguarding lead. Our schools sector page covers lockdown and intruder resistance at entrances, and the windows beside those entrances need the same thought.
Visitor entrances need windows that admit light and resist attack at the same time. A glazed entrance screen lets reception see who is at the door before it is opened, and a rated screen holds while the door is checked. A screen that is not rated is a screen that fails at the first blow, and the entrance behind it is open. Rate the screen for the attack it could face, and order it as one assembly with the door beside it.
Frames, beads and fixings: the assembly that holds the glass
The frame is half the window. A steel frame holds a heavy pane and resists a forced entry, a timber frame suits a listed building or a conservation area, and an aluminium frame suits a large glazed screen. The frame must carry the same rating as the glass, because a rated pane in a frame that fails early is a window that fails early. Ask for the frame, the beads, the seals and the fixings as one assembly, and ask for the test evidence naming all of them.
Beads hold the pane in the frame, and a bead swapped on site for a neater one takes the window outside its evidence. Fit only the bead system the test evidence names, and check that the beads are fixed all the way round the pane. Fixings hold the frame in the wall, and a frame fixed into a partition that was never built to hold it will move when the window is used. A rated window in an unrated wall gives an unrated opening.
Seals close the gap between the pane and the frame, and between the frame and the wall. Intumescent seals close the gap in a fire, expanding at roughly 200 to 250 degrees, and a seal that has been painted over cannot expand. Tell the decorators that seals are never to be coated, and check the seals after any painting work in the building.
The bead that holds the glass: fixings a school window cannot do without
A school window is opened, shut, leaned on and cleaned every day, and the bead that holds the glass takes more of that life than any other part. An internal bead sits on the room side of the frame, so it cannot be prised from outside, and a bead that has been screwed or clipped in place should be checked for fixings that have worked loose. A bead that a pupil can lift with a fingertip has already failed, and a pane that can be lifted out of its frame is no barrier at all, whatever the glass rating says.
Check the fixings into the wall on the same visit as the bead. A frame fixed into solid masonry holds differently from a frame fixed into a stud wall, and a fixing that has loosened in a soft block wall will let the frame move every time the sash is shut. Look for fixings that have pulled, packers that have slipped, and sealant that has cracked away from the frame, because a frame that moves lets the sash sit short of its seal and lets draughts and rain through.
Read the glass rating whole before ordering. LPS 1270 grades a pane with three digits for hand, arm and body passage, so a pane that stops a hand may still let an arm through, and all three digits belong on the schedule. For manual attack on glass, EN 356 runs from P1A to P8B, and the top classes are set by axe blows: 30 to 50 for P6B, 51 to 70 for P7B, and 70 or more for P8B. EN 1627 sets resistance classes RC1 to RC6 for windows, doors and shutters, so ask which standard tested the glass and read the rating whole. Our fire rated windows guide covers how glass, frame and beads are tested together as one assembly.
Ground floor glass: the rooms where the rating rises
Ground floor rooms ask more of a window than rooms upstairs. A classroom at ground level faces the playground, the car park and the street, and the glass there meets balls, bags and hands every day, so the rooms at ground level take the higher rating and the rooms above take the lower one. A science room, a hall and a sports changing room ask for more again, because the activity inside them throws harder and more often. Put the rating on the schedule beside the room, not beside the building, so a ground floor classroom is never fitted with the glass meant for a first floor office.
Safeguarding shapes the glass as much as resistance does. A window that lets staff see into a room from the corridor keeps pupils safe, and a vision panel at the right height does that job without opening the room to the corridor. One-way vision, blinds and manifestation all change what can be seen from outside, and the choice belongs on the schedule beside the rating, because a pane that is easy to see through from the playground is a different pane from one that is not. Our fire door regulations for schools guide covers the doors that share the same corridors.
| Part | What to check | Why it matters |
|---|---|---|
| Bead | Internal bead, fixings tight | A loose bead lets the pane out |
| Frame fixings | Fixings suit the wall, packers firm | A moving frame breaks the seal |
| Glass rating | LPS 1270 digits, EN 356 class | A partial rating proves nothing |
| Escape opening | Opens fully, stays open, no key | A stuck sash blocks the route |
File the test report, the classification and the schedule with the order, so the next specifier can see which standard proved which window, and which room each rating belongs to.
Ground floor, first floor and the rooms that need more
Not every school window needs the same rating. A ground floor classroom window needs a security rating and a restrictor. A first floor window needs the same where it can be reached from a roof or a canopy. A corridor window needs a fire rating where the corridor is a protected route. A plant room window needs a higher fire rating, because the room behind it holds a higher risk. A library window needs a quiet sash and a pane that holds the compartment line.
Science laboratories, design workshops and kitchens need more than a classroom window. A laboratory holds chemicals and gas, a workshop holds tools that can break glass, and a kitchen holds heat and steam. The windows in those rooms need a rating that suits the room behind them, and the fire strategy names the period for each opening. Our types of security doors guide sets out the range of doors a school may need, and the same habit serves the windows: write the schedule room by room, then order against it.
Sports halls and assembly halls need windows that take impact. A ball struck at a window, a pupil pushed against a pane, or a chair knocked into the glass are all part of daily use in a hall. The glazing in those rooms should resist impact as well as forced entry, and the frame should hold the pane when it is struck. A pane that breaks under a ball is a pane that will be broken often, and each break is a week with a boarded window.
What the order should name for a school window
Ordering windows for a school is a specification exercise, not a shopping exercise. The order should name the rating in full, fire and security together where the opening needs both, and it should name the glass, the frame, the beads, the seals and the fixings as one assembly. The security side needs its own evidence where the window must also resist attack: a class to EN 1627 or a rating to LPS 1270, on the whole window, not on the pane alone.
Finally, order the evidence with the windows. The test report, the classification and the hardware schedule should arrive with the assembly, and the handover pack should name the inspection routine the school will follow. A school that files the evidence on the day the windows arrive has a record it can use for the whole life of the estate. Our how to specify security doors guide covers the same discipline for rated doors, and our dual certification guide works through how fire and security sit on one assembly.
| Room | Window position | What it must do | What to check |
|---|---|---|---|
| Classroom, ground floor | External window | Hold fire, resist forced entry, open for air | Rating, restrictor, seals |
| Corridor | Glazed screen or window | Hold the corridor as a protected route | EI rating, beads, smoke seals |
| Library | Reading room window | Close quietly, hold the compartment line | Sash, latch, hold-open release |
| Entrance | Glazed screen beside the door | Let reception see out, resist attack | Rating, frame, fixings |
| Plant room and store | High-risk room window | Hold a higher-risk fire inside its own room | Higher rating, seals, gaps |
In a school, a window is not a hole in the wall with glass in it. It is a tested assembly that must hold fire, resist attack and still let a classroom breathe.
Do school windows need a fire rating?
They need the rating the fire strategy names for their position. A window in a corridor that serves as a protected route needs a fire rating, usually EI because children pass close to it, while a window in an external wall that is not part of a compartment line may need none. The fire strategy names the period for each opening.
What is the difference between E, EW and EI for a school window?
E holds back flame and hot gases, EW holds back flame, hot gases and some radiant heat, and EI holds back flame, hot gases and heat, with a limit on temperature rise on the safe side: an average of 140 degrees Celsius and a maximum of 180 degrees Celsius. Escape routes usually need EI because children pass close to the window.
Can one window carry a fire rating and a security rating?
Yes, where both sets of evidence cover the same construction. The fire classification comes from a test to EN 1634-1 and the forced entry rating from a test to EN 1627 or LPS 1270, and the two must be proved on the same window. A pane that carries a fire class in one frame carries no rating at all in a different frame.
How do window restrictors fit with fire escape?
A restrictor limits how far a window opens, so it stops a child climbing out and stops an intruder climbing in. A window that serves as an escape route must open in one action, without a key and without a tool, so the fire risk assessment names which windows are escape windows and the routine checks them as often as the doors.
What should a school window schedule name for each opening?
The room, the position, the fire rating, the security rating where one is needed, and the glass, the frame, the beads, the seals and the fixings as one assembly. The schedule should travel with the order, and the test report, the classification and the hardware schedule should arrive with the windows.
Phased rooms: the order that keeps lessons running
A school cannot close a classroom block for a window programme, so the work runs room by room while lessons continue next door. The order of rooms matters more than the speed of the work. Start with the rooms the school can empty without moving a class, then move to the rooms that need a timetable change. A room that is worked on while pupils sit in it is a room where the work stops every few minutes, so plan the sequence with the school, not around it.
Each room should be finished and handed back before the next room is opened up. A half finished room leaves a window without its bead and fixings in place, and a window without its bead is a window that cannot hold its glass. The security windows page sets out how the glass, frame, beads and fixings work as one assembly, and the same rule holds during a retrofit. Nothing should be left overnight with a pane held in by a temporary fix.
Escape routes stay open through the whole programme. A window that serves as an escape route must open in one action, without a key and without a tool, so the route must be checked at the end of each working day, not only at the end of the job. Where a room has only one escape window, that window is replaced last in the room, after the other windows are finished and signed off. The fire strategy names which windows are escape windows, and the day plan should name them too.
Safeguarding shapes the working day as much as the timetable does. Workers should not pass through rooms where pupils are taught, and tools and glass should not sit in corridors pupils use between lessons. The school names the routes workers may use and the times they may use them, and the work stops while pupils move between rooms. A window programme that respects those routes runs slower on paper and faster in practice, because nothing has to be cleared away in a hurry.
Handover checks: what the school signs off room by room
Handover happens room by room, not at the end of the whole job. When a room is handed back, the school checks the window it has just received while the work is still fresh and the team is still on site. A fault found in that room is fixed the same day, while a fault found at the end of the job waits for a return visit. The maintenance checklist gives the same habit for doors, and it works for windows too.
| Room check | What to look at | What it proves |
|---|---|---|
| Restrictor | Opens to the set limit and no further | The window cannot be opened wide enough to climb through |
| Escape window | Opens in one action, without a key and without a tool | The escape route works on the day it is needed |
| Beads and fixings | Beads seated, fixings tight, no gaps at the corners | The glass stays in the frame under attack |
| Seals and sash | Seals touch all round, sash shuts and latches | Draughts and rattles do not follow the new window |
The evidence pack travels with the handover, room by room. The test report, the classification and the hardware schedule for the windows in that room should be filed when the room is signed off, not collected at the end of the job. The education sector page sets out the standards that apply across a school estate, and the handover pack is where that evidence is kept. A school that files the evidence room by room has a record it can use for the whole life of the estate.
Get a free quote
Related
More in guides for specifiers
Products
One supplier for the whole building envelope
Ready to specify your project?
Free assessment, written specification and test evidence. Reply within one working day.