Fire Rated Windows Explained

Fire rated windows in compartment walls and on escape routes: EI30 and EI60, fixed and openable, what the rating covers and what to check before you order.

  • ✓Third-party test evidence with every product
  • ✓Written specification you can issue to tender
  • ✓Supplied and installed across the UK
Prefer to talk?+44 7352 267239

Get a free project quote

Rating, written specification and budget range within one working day.

ArxBridge Quote Form

Confidential. No cost, no obligation.

Third-party tested

Evidence with every quote

UK manufactured

Made to your sizes

One accountable team

Specify, supply, install

Confidential handling

Details never shared

A fire rated window is a window tested as part of a wall. The pane, the frame, the beads and the seals were tested together to EN 1634-1, and the rating belongs to that tested assembly, not to the glass on its own. A pane that carries a fire class in one frame carries no rating at all in a different frame, because the test never covered that combination. The window is only as strong as the weakest part of the assembly, and the test report is the document that names every part.

Windows sit in compartment walls, along corridors, around stair cores and beside escape routes. They let light through a wall that must hold fire, and they let people see what is on the other side before a door is opened. A fixed window never opens, so its rating rests on the pane and the frame alone. An openable window has a sash, hinges and a handle, so its rating rests on the moving parts as well, and on whether the sash is closed when fire breaks out. The two types look alike from the corridor, and the specification must tell them apart.

The two periods a specifier meets most often are EI30 and EI60. The number is the minutes the assembly held its rating in the furnace test to EN 1634-1, and the letters say what it held back. Our fire rated glass cost guide works through what drives the cost of the glass, the class, the period, the build-up and the frame, with factors only and no invented prices. Our fire rated glazed doors page covers the same assembly discipline for a leaf that opens every day.

  • EI30 and EI60Fire resistance periods tested to EN 1634-1
  • E, EW and EIIntegrity, radiated heat limit, insulation
  • BS EN 16034Product standard for fire rated windows and doorsets
  • 140 and 180 degreesTemperature rise limits on the safe side for EI

A window in a compartment wall is part of the wall

Compartmentation divides a building into parts, and a fire in one part is held there long enough for the rest of the building to empty. The walls do the dividing, and the windows are the weak points in the walls, so a window in a compartment wall has to hold as long as the wall it stands in. A window rated EI60 in a 30 minute wall gives a 30 minute opening, and a window rated EI30 in a 60 minute wall gives a 30 minute opening too. The wall and the window are one decision, and the fire strategy is the place where they meet.

The rating of the window must match the rating of the wall, and the glass must match the rating of the window. A 30 minute pane in a 60 minute window leaves the window at 30 minutes, whatever the frame is rated to. The same rule runs through the whole opening: the pane, the beads, the frame and the seals must all carry the classification and the minutes the strategy names. A window ordered as a pane on its own, with the frame and beads to follow, is an assembly with no evidence behind it.

The frame matters as much as the glass. A heavy EI pane needs a frame that can carry its weight for the whole life of the building, and the beads that hold the pane must be the bead system the test evidence names, with the fixings the evidence names beside it. A bead swapped on site for a neater looking one takes the window outside its evidence, because the rating belongs to the tested assembly. Our fire ratings page sets out the three letters, the periods and how to read a rating, and our fire door regulations for commercial buildings guide covers the Order, the 2022 regulations and Approved Document B in full.

Fixed windows: the pane, the frame and the beads

A fixed window has no moving parts, and that is its strength. The pane sits in the frame, the beads hold it, the seals close the edge, and nothing in the assembly depends on someone remembering to shut it. The rating rests on the build-up of the pane and on the frame that carries it. EI glass needs an interlayer or a gel layer that holds the temperature rise on the safe side to an average of 140 degrees Celsius and a maximum of 180 degrees Celsius above ambient, and that build is thicker and heavier than an E pane of the same size. The frame, the beads and the fixings must carry the extra weight, so the whole window moves with the pane.

Ordinary float glass has no place in a fire wall. It cracks under thermal shock and falls out of its beads early in a fire, leaving an open hole where the wall was meant to hold. Only glass named in the test evidence for that window, held in the tested beads, belongs in a compartment wall. A thicker pane does not always mean a longer rating, because two panes of the same thickness can carry different classes. The make-up of the layers decides the class, and the test report is the proof. Ask for the report that states the standard, the class and the period for the exact glass build being bought.

The size of the pane is set by the test evidence too. The tested aperture is the maximum for that window, and a larger pane needs its own evidence, because a bigger pane heats differently and puts more load on the beads. A fixed window that is ordered bigger than the tested aperture is a window outside its evidence, and no certificate can be written for it. Keep the aperture inside the evidence, and keep the beads, the seals and the frame exactly as the evidence names them.

Need this specified for your project?Free rating, written specification and budget range within one working day.
Get a free quote

Openable windows: the sash, the hardware and the closer

An openable window has a sash that moves, and the rating depends on that sash being closed when fire breaks out. Hinges carry the sash, the handle pulls it home, and the closing device holds it shut against the seals. A sash that is left open has no fire performance at all, whatever its certificate says, because the opening is open. The hardware must be the hardware the test evidence names, fitted in the pattern the evidence names, or the window leaves its evidence behind.

A window that is held open for air during the day needs a release that closes it when the alarm sounds. A wedge, a prop or a hook on the wall has no such release, and a sash held open by one of those will stand open in a fire. Fit the right release and the right closing device, so the window can stand open when the building needs it open and still close when it matters. The release must be tested with the window, not added afterwards, because the closing device is part of the tested assembly.

Check the sash at every inspection, and check that it closes and latches on its own. A sash that drags on the frame, a hinge that has dropped, or a handle that no longer pulls the sash home are faults to fix, not to live with. A window that does not close has no rating to check, and the fault should be written down beside the date it was found and the date it was fixed. Our fire door inspection checklist gives the checks that catch a failing leaf before it matters, and the same habit of walking, looking and writing down applies to windows.

EI30 and EI60: reading the letter and the minutes

The letter matters as much as the number. An E window stops flames and hot gases passing through for the stated minutes, but the glass on the safe side can still become hot. An EW window adds a limit on radiated heat, so a person can stand near it without being driven back. An EI window adds insulation, so the temperature rise on the safe side is limited to an average of 140 degrees Celsius and a maximum of 180 degrees Celsius, and the window can be touched. Escape routes and corridors where people pass close to the window usually need EI, because people escape past the window and may need to put a hand near it.

The periods run from E30 to E240, and the number is the minutes the assembly held its rating in the furnace test to EN 1634-1. EI30 and EI60 are the periods a specifier meets most often, because 30 minutes covers most compartment walls and 60 minutes covers the walls that protect longer escape routes and stair cores. The period comes from the building fire strategy, not from the window, so ask the fire engineer for the schedule and specify windows tested to match it. Never order a lower class or a shorter period than the strategy names, and never change the letter or the minutes on site without the fire engineer agreeing.

A higher class or a longer period than the strategy asks for is possible, but the extra build is money spent on performance nobody asked for, and the extra weight has to be carried by the frame and the fixings. The product standard for fire rated windows and doorsets is BS EN 16034, and the test report should state the standard, the class and the period for the exact assembly being bought.

Windows on escape routes: light, sight and the way out

Windows on escape routes do two jobs at once. They let daylight into a corridor or a stair core, and they let people see what is on the other side before they open a door. A corridor window that shows a clear corridor tells a person the route is open, and a stair window that shows smoke on the landing tells them to turn back. The window must hold as long as the door beside it, because a corridor with a 60 minute door and a 30 minute window is a 30 minute corridor. The fire strategy names the period for each opening, and the window and the door on the same route must be read together.

Schools show why this matters. Children escape in groups, teachers lead classes along corridors, and the windows along the route let staff see where the children are and whether the way ahead is clear. A school window needs the same EI rating as the doors on the route, and the same care over seals and gaps, because the corridor is the route every class uses to get out. Our fire door regulations for schools guide covers Building Bulletin 100, FD30 and FD60, and school inspection duties, and our security doors and gates for schools page covers the security side of the same buildings.

Smoke reaches people long before flames do, so a window on an escape route must be judged on smoke as well as fire. A fire rating to EN 1634-1 tests flame and heat, and smoke passes through a cold gap long before heat reaches the seals. Where the fire strategy asks for smoke control, the window needs a smoke rating to BS EN 1634-3, Sa or S200, and the S in a rating such as FD30S marks it. A fire rating on its own does not prove smoke control, so ask for the smoke evidence by name.

Smoke, seals and the gap around the frame

The gap around the frame is the place a window rating is most often lost. The pane can be right, the beads can be right and the frame can be right, and the window can still fail at the edge where the frame meets the wall. That gap must be sealed with the material the test evidence names, fitted in the way the evidence names, or the compartment line is broken at the very point it matters most. A window fitted into a wall with an unsealed gap is a window with a hole beside it.

Intumescent seals close the gap in a fire, expanding at roughly 200 to 250 degrees, and smoke seals close it against cold smoke. Both have to be fitted, intact and unpainted, or the seal is a seal in name only. Paint over an intumescent seal and it cannot expand when heat reaches it, so tell the decorators that the seals are never to be coated.

The frame and the wall must be read together. Check the wall, the head detail and the fixings with the window, and order them as one opening. Our fire rated glazed doors page works through beads, seals and the frame that holds the glass, and the same discipline applies to a window frame.

Windows that must do two jobs: fire and security together

Some windows must hold fire and resist forced entry, and the two jobs need two sets of evidence on one assembly. A fire classification to EN 1634-1 and a forced entry rating to LPS 1175 are separate tests, and each rating needs its own test evidence on the same construction. The glass and the bead fixings sit on both sets of evidence, so a pane that passes the fire test with one bead system and the security test with another has no combined rating at all. Ask for both certificates against one identical specification, and check that the glass, the beads and the frame are the same on both.

The same rule covers a window that must be both fire rated and bullet resistant. The pane carries the layers for both jobs, and the test evidence must name both the fire class and the BR class from EN 1063 on the same build. Our bullet resistant windows page covers the BR classes, and our dual certification guide works through how fire and security sit on one assembly.

Security ratings are read the same way as fire ratings: from the test, not from the label. LPS 1175 runs from A1 to H20, with B3, C5 and D10 as the tool examples a specifier meets most often, and EN 1627 runs from RC1 to RC6. PAS 24 covers doorsets for dwellings, and Secured by Design is a scheme, not a rating, so a window that names the scheme without naming the test has proved nothing.

Writing the order: one window, one set of evidence

Ordering fire rated windows is a specification exercise, not a shopping exercise. The order should name the rating in full, EI30 or EI60 with the letter and the smoke rating where the strategy asks for it, and it should name the pane, the frame, the beads, the seals and the hardware as one assembly. Our how to specify security doors guide covers the same discipline for rated security doors, and our types of security doors guide sets out the range of openings a building may need.

Order the evidence with the windows. The test report, the classification and the hardware schedule should arrive with the assembly, and the handover pack should name the inspection routine the building will follow. A building that files the evidence on the day the windows arrive has a record it can use for the whole life of the building. Our fire rated sliding doors guide sets out the same discipline for a leaf on a track, where the evidence travels with the assembly too.

Finally, check the windows on delivery, before they are fitted. Check the pane against the order, the beads against the evidence, the seals against the schedule, and the hardware against the test report. A window that arrives wrong and is fitted anyway is a window that has to be taken out again, and a window that arrives right and is fitted with the wrong beads is a window outside its evidence.

Window position Period What it must do What to check
Compartment wall, fixed EI60 Hold the wall as a fire line, let light through Pane class, beads, frame to wall seal
Corridor window EI30 Let staff see the corridor, hold the escape route Glass class, seals, frame fixings
Stair core window EI60 Protect the stair while people come down Smoke seals, frame seal, pane class
Escape route window EI30 or EI60 Show the way ahead is clear, hold as long as the door Rating matches the door, seals, gaps
Plant room window EI60 Hold a higher-risk fire inside its own compartment Seals, gaps, self-closing sash

A window with no test evidence behind it is ordinary glass in a fire wall.

What is the difference between E and EI for a window?

E covers integrity only: the window stops flames and hot gases passing through for the stated minutes. EI adds an insulation limit on temperature rise on the safe side, an average of 140 degrees Celsius and a maximum of 180 degrees Celsius above ambient. Compartment walls and escape routes usually specify EI, because people pass close to the window and may need to put a hand near it.

Can a fire rated window open?

Yes, where the openable sash was tested with the window. The sash, the hinges, the handle and the closing device must be the hardware the test evidence names, and the sash must close and latch on its own. A window that is held open during the day needs a release that closes it when the alarm sounds. A sash left open has no fire performance, whatever its certificate says.

Does a window need the same rating as the wall it stands in?

Yes. The window is the weak point in the wall, so a 30 minute pane in a 60 minute wall gives a 30 minute opening, and a 60 minute window in a 30 minute wall gives a 30 minute opening too. The wall and the window are one decision, and the fire strategy names the period for each opening. Never order a lower class or a shorter period than the strategy names.

Can one window be fire rated and bullet resistant?

Yes, with combined evidence. The pane carries the layers for both jobs, and the test evidence must name both the fire class and the BR class from EN 1063 on the same build. Ask for both certificates against one identical specification, and check that the glass, the beads and the frame are the same on both. A bullet resistant window without a fire test is not a fire window.

What paperwork proves a fire rated window?

The EN 1634-1 test report for the exact assembly, stating the classification and the minutes, plus third-party certification under the LPS 1056 scheme where the strategy calls for it. Go through the submittal part by part and confirm each matches the report: the pane, the beads, the frame, the seals and the hardware. If any part is missing from the evidence, the rating is unproven.

What a fire rated window rating does not prove

A rating on a fire rated window proves one thing: the tested assembly held its rating in the test. It proves nothing else. Treat the certificate as a narrow statement, and ask what it leaves out before the order is placed.

It does not prove the glass suits the frame. A pane that carries a fire class in one frame carries no rating at all in a different frame, because the test never covered that combination.

It does not prove the window holds as long as the wall. A window rated EI60 in a 30 minute wall gives a 30 minute opening, and a window rated EI30 in a 60 minute wall gives a 30 minute opening too. The wall and the window are one decision, and the fire strategy names the period for each opening. EI adds an insulation limit on temperature rise on the safe side, an average of 140 degrees Celsius and a maximum of 180 degrees Celsius, and escape routes usually need EI because people pass close to the window.

It does not prove smoke is controlled. A fire rating to EN 1634-1 tests flame and heat, and smoke passes through a cold gap long before heat reaches the seals. Where the fire strategy asks for smoke control, the window needs a smoke rating to BS EN 1634-3, Sa or S200, and the S in a rating such as FD30S marks it. A fire rating on its own does not prove smoke control, so ask for the smoke evidence by name.

It does not prove the sash will close. An openable window has a sash, hinges and a handle, so its rating rests on the sash being closed when fire breaks out. A sash that is left open has no fire performance at all, whatever its certificate says. A window held open for air needs a release that closes it when the alarm sounds.

Mistakes that break a fire rated window order

Most fire rated window orders fail in small ways. Each mistake below has the same result: a window that looks right and cannot be proved.

Mistake Why it fails What to do instead
Pane ordered without the frame The rating belongs to the tested assembly, not the glass alone. Order pane, frame, beads and seals as one assembly.
Beads swapped on site A neater bead takes the window outside its evidence. Fit only the bead system the test evidence names.
Gap around the frame left unsealed The compartment line is broken beside the window. Seal the gap with the material the evidence names.
Paint over the intumescent seals The seals cannot expand when heat reaches them. Tell the decorators the seals are never to be coated.
Sash held open with a wedge A sash left open has no fire performance at all. Fit a release that closes the sash when the alarm sounds.

Keep the evidence with the windows. The test report, the classification and the hardware schedule should travel with the assembly. For the glass behind the order, see our fire rated glass cost guide, and for how fire and security sit on one assembly, see our dual certification guide.

Specifying fire rated windows?Send the window schedule and the fire strategy for a tested assembly quotation.
Get a free quote

Related

More in guides for specifiers

10 mistakes when specifying certified security doors 10 steps to specify an LPS 1175 door Acceptance and Snagging of a Security Door or Barrier Job Access Control Doors Acoustic Doors: Ratings and Specification After a Forced Entry Attempt: Checking a Security Door Airport Security Doors Anti-Ligature Doors for Mental Health Wards Anti-Ram Bollards Anti-ram gates and barriers: protecting vehicle entrances Arcade Security Doors Explained Automatic Doors Automatic Gates Cost Factors Automatic Vehicle Barriers Ballistic Panels Bank Security Doors Bingo Hall Security Doors Explained Blast doors: glazed vs solid and how they are rated Blast protection window film: what it does and what it cannot do Blast resistant windows: what drives the cost and how to specify them Bollard Cost Factors Explained Bollard regulations in the UK: spacing, height and depth Bookmaker Security Doors Explained Builders Merchant Security Doors Bullet Resistant Glass Cost Factors Bullet resistant glass ratings explained: BR1 to BR7 and SG classes Bullet resistant vs bulletproof glass: what the difference means Buying Security Doors and HVM Through Public Frameworks Car Park Security Doors Explained Car Showroom Security Doors Casino Security Doors Explained CDM 2015 Duties When Security Doors, Shutters or HVM Are Installed Cinema Security Doors Cleanroom Doors Cold Store Doors College Security Doors Commissioning, Handover and the O&M Manual for Security Doors and HVM Communal entrance doors for flats: Secured by Design and what to specify Community Centre Security Doors Control Room Doors Court Security Doors Crash Rated Fences and HVM Fencing Explained Data centre physical security: doors, glazing, HVM and shielding by zone Dental Practice Security Doors Depot Security Doors Explained Door Entry Systems Due Diligence When Selecting Vehicle Security Barriers Emergency Exit Doors EMP Shielding Cost Factors Explained Exhibition Centre Fire Door Rules Exhibition Centre Security Doors Factory Security Doors Faraday cage vs RF shielded room: what a business needs FB4 vs FB6 vs FB7: how to choose a ballistic rating Fire and security doors: how dual certification works Fire Compartmentation Fire Curtains Fire Door Certification Fire Door Closers Explained Fire Door Cost Factors Fire Door Duties of the Accountable Person Fire Door Gaps Fire Door Hardware Explained Fire door inspection checklist for steel and timber doors Fire Door Maintenance Fire Door Regulations Care Homes Fire Door Regulations for A and E Departments Fire Door Regulations for Airports Explained Fire Door Regulations for Bowls Clubs Fire door regulations for commercial buildings in the UK Fire Door Regulations for Dialysis Centres Fire Door Regulations for Hockey Clubs Fire Door Regulations for Hospitals Explained Fire Door Regulations for Offices Explained Fire Door Regulations for Operating Theatres Fire Door Regulations for Retail Explained Fire Door Regulations for Schools Explained Fire Door Regulations for Snooker Clubs Fire Door Regulations for Stadiums Fire Door Regulations for Student Accommodation Fire Door Regulations for Warehouses Fire Door Regulations Leisure Centres Fire Door Regulations Restaurants Fire Door Remediation Programme for Housing Providers Fire Door Rules for Badminton Clubs Fire Door Rules for Bingo Halls Fire Door Rules for Bookmakers Fire Door Rules for Bowling Alleys Fire Door Rules for Car Parks Fire Door Rules for Car Showrooms Fire Door Rules for Cinemas Fire Door Rules for Climbing Centres Fire Door Rules for Colleges Fire Door Rules for Community Centres Fire Door Rules for Cricket Clubs Fire Door Rules for Dental Practices Fire Door Rules for Depots Explained Fire Door Rules for Golf Clubs Fire Door Rules for GP Surgeries Fire Door Rules for Gyms Explained Fire Door Rules for Ice Rinks Fire Door Rules for Maternity Units Fire Door Rules for Mental Health Units Fire Door Rules for Museums Fire Door Rules for Oncology Units Fire Door Rules for Opticians Fire Door Rules for Pawnbrokers Fire Door Rules for Petrol Stations Fire Door Rules for Pharmacies Fire Door Rules for Ports Fire Door Rules for Post Offices Fire Door Rules for Prisons Fire Door Rules for Rehabilitation Centres Fire Door Rules for Self Storage Fire Door Rules for Shopping Centres Fire Door Rules for Squash Clubs Fire Door Rules for Supermarkets Fire Door Rules for Swimming Pools Fire Door Rules for Tennis Clubs Fire Door Rules for Theatres Fire Door Rules for UK Arcades Fire Door Rules for UK Casinos Fire Door Rules for UK Hospices Fire Door Rules for Walk-in Centres Fire Door Signage Fire Door Vision Panels Fire Doors and Gateway 2 in Higher-Risk Buildings Fire Rated Glass Cost Explained Fire Rated Sliding Doors Explained Fire Rated Windows Cost Factors Fire Safety Enforcement Notices and Fire Doors: What the Responsible Person Must Do Flat Entrance Doors: PAS 24 and Fire Rated Forced Entry vs Ballistic vs Blast: Which Rating a Site Needs Garage Security Doors Explained Gate Automation Explained Golden Thread Records for Fire Doors GP Surgery Security Doors Explained Gym Security Doors Explained High Speed Doors HMO Fire Doors Hospice Security Doors Explained Hospital Security Doors: Wards, A&E, Plant Hospital Security Gates Hotel Fire Doors Hotel Security Doors How to choose HVM bollards: fixed, shallow mount, removable and automatic How to keep an LPS 1175 door rating valid after installation How to Specify Fire Doors in a Housing Tender How to specify security doors: a checklist for architects How to Verify a Secured by Design Listing How to Verify an LPS 1175 Certificate on Red Book Live How to Write an Operational Requirement for Physical Security HVM planters and street furniture: protection that blends in In-Service Care of Vehicle Security Barriers Installation Handover: LPS 1175 Doors and PAS 68 Barriers Intumescent Seals ISO 16933 explained: EXV and SB classes and hazard ratings ISO 22343 vehicle security barriers explained Keeping a Dual-Certified Fire and Security Door Valid in Service Laboratory Security Doors Layered Security for a Site: Deter, Detect, Delay, Mitigate, Respond Lead Times and Programme Risks for LPS 1175 Doors Leisure Centre Security Doors Library Security Doors Listed Building Fire Doors Loading Bay Doors Explained Lockdown and Access Control Hardware on an LPS 1175 Door LPS 1175 Gates and Grilles Explained LPS 1175 Issue 8 explained: from SR1 to SR8 to A1 to H20 LPS 1175 Roller Shutters LPS 1175 vs ASTM F2781 and Other US Ratings Explained LPS 1175 vs EN 1627: how UK and European burglar resistance ratings compare LPS 1175 vs PAS 24: which security standard does your door need? LPS 1175 Windows and Walling Explained Martyn’s Law and Places of Worship: What a Buyer Checks for Doors and Entry Control Martyn’s Law Enhanced Tier: Physical Measures and the Specifier Brief Martyn’s Law Standard Tier: Procedures, Doors and Shutters Martyn’s Law Timeline and the SIA Regulator Martyn’s Law: what premises must do and which physical measures to consider Master Key Systems MRI and RF shielded rooms: how they work and what to specify Museum Security Doors NPSA Catalogue of Security Equipment (CSE) Explained NPSA Forced Entry and Blast Guidance for Government Sites NPSA Guidance on Lockdown and Marauding Attack: What It Asks of Doors and Entrances Office Security Doors Optician Security Doors Explained Panic Hardware PAS 24 requirements for doors and windows explained PAS 68 Bollard Foundations Explained PAS 68 bollards: ratings, spacing and cost factors PAS 68 vs IWA 14 vs ISO 22343: hostile vehicle mitigation standards explained Pawnbroker Security Doors Explained Pedestrian Gates Petrol Station Security Doors Pharmacy Security Doors Planning Permission for Security Shutters, Gates and Bollards on Commercial Premises Plant room doors: fire, security and ventilation requirements Plant Room Fire Doors Port Security Doors Post Office Security Doors Explained Powder coating vs galvanising vs paint for steel Preliminary Market Engagement for Security Doors and HVM Prison Security Doors Programming a Security Door and Barrier Package on a Live Site Public-Sector Tender Response Checklist for Security Door and HVM Supply Reading a PAS 24 and SBD Door Test Report Regulation 38 Fire Safety Information at Handover for Fire-Rated Security Doorsets Replacing Security Doors in an Occupied Building Restaurant Security Doors Retail Security Doors Revolving Doors RF shielding standards and how shielded rooms are tested Rising Bollard Cost Factors Road Blocker Cost Factors Explained Road Blockers Explained Roller Shutter Cost Factors: What Drives the Price Roller shutter regulations in the UK: safety and maintenance Safe room and panic room doors: specification basics Safety Duties for Powered Doors, Gates and Barriers on Commercial Sites School Security Doors Sectional Doors Secured by Design explained: is it mandatory for doors? Secured by Design vs NPSA vs LPCB: Which One You Need Security Door Locks Security Door Maintenance Checklist Security Doors and Access for Everyone: What Approved Document M Asks Security Doors for A and E Departments Security Doors for Badminton Clubs Security Doors for Bowling Alleys Security Doors for Bowls Clubs Security Doors for Climbing Centres Security Doors for Cricket Clubs Security Doors for Dialysis Centres Security Doors for Golf Clubs Security Doors for Hockey Clubs Security Doors for Ice Rinks Security Doors for Maternity Units Security Doors for Mental Health Units Security Doors for Oncology Units Security Doors for Operating Theatres Security Doors for Rehabilitation Centres Security Doors for Snooker Clubs Security Doors for Squash Clubs Security Doors for Swimming Pools Security Doors for Tennis Clubs Security Doors for Walk-in Centres Security Doors West Midlands Explained Security Fencing Security Gates Cost Factors Explained Security shutters vs high performance roller doors Security shutters vs retractable grilles: which suits retail and commercial openings? Security Turnstiles Explained Security Window Film Security Windows for Schools Explained Self Storage Security Doors Server Room Doors Explained Shopping Centre Security Doors Smoke Control Doors Explained Smoke Curtains Specification Mistakes When Mixing LPS 1175, PAS 24 and SBD in One Tender SR2 vs SR3 vs SR4 security doors: choosing the right LPS 1175 level Stadium Security Doors Steel Door Frames Steel vs aluminium security doors: strength, ratings and looks Steel vs timber fire doors: which suits your building? Student Accommodation Security Doors Substation doors: security, ventilation and specification Supermarket Security Doors Telescopic Bollards Tender Evaluation Criteria and Scoring for Security Doors and HVM The Scope of a Maintenance Contract for Security Doors and Barriers Theatre Security Doors Thermal and Weather Performance of External Security Doorsets Thermally broken steel security doors: U-values and certification Traffic Calming as Hostile Vehicle Mitigation Transport hub security requirements Turnstile Cost Factors Explained Turnstile vs speed gate vs security portal: choosing entrance control Types of security doors for commercial buildings University Security Doors Explained Vehicle Dynamics Assessment: What It Tells the Buyer Before a Barrier Is Specified Warehouse Security Doors Explained Warehouse Security Gates Warranty, Defects Liability and Guarantees for Security Doors and Barriers What affects the cost of a bullet resistant door What affects the cost of a high-security door in the UK Window Security Bars View all →

Products

One supplier for the whole building envelope

Ready to specify your project?

Free assessment, written specification and test evidence. Reply within one working day.