Flat Entrance Doors: PAS 24 and Fire Rated
One doorset for a flat must hold a PAS 24 security rating and an FD30S fire rating, with the letterplate, viewer and closer tested as part of the same assembly.
- ✓Third-party test evidence with every product
- ✓Written specification you can issue to tender
- ✓Supplied and installed across the UK
Get a free project quote
Rating, written specification and budget range within one working day.
Confidential. No cost, no obligation.
Third-party tested
Evidence with every quote
UK manufactured
Made to your sizes
One accountable team
Specify, supply, install
Confidential handling
Details never shared
The door to a flat has two jobs at once. From the corridor it must resist a forced entry attempt, and from the flat it must hold back fire and smoke long enough for the stay-put strategy to work. One doorset carries both duties, and both must be tested on the same construction, with the same locks, closer, seals, letterplate and viewer that will be fitted on site.
A flat entrance door is not a communal entrance door and it is not an ordinary internal door. It sits on the line between one home and the shared parts of the building, so it answers to two sets of rules and two different kinds of threat. The security rating protects the people inside the flat. The fire rating protects the people outside it, in the corridor and on the stairs. Neither rating means much without the other, and neither survives a change to the hardware after the door is fitted.
- FD30S30 minutes of fire integrity plus smoke seals, the normal requirement for a flat entrance door onto common parts.
- PAS 24The security test behind Approved Document Q for doors that give access into a flat from the common parts.
- 260 by 40 mmThe largest letterplate aperture Approved Document Q allows, with a flap or feature to hinder reaching through.
- Checked every yearIn buildings over 11 metres, the responsible person checks flat entrance doors annually under the Fire Safety (England) Regulations 2022.
One door, two jobs: security on the corridor side, fire on the flat side
Each flat is its own fire compartment. The walls and floor around it hold fire back, and the entrance door is the one opening in that compartment that people use every day. When a fire starts inside a flat, the door is what keeps smoke and flame in the flat while the rest of the building stays safe. That is the stay-put strategy: residents in other flats stay where they are because the compartment holds.
From the corridor side the same door faces a different threat. Anyone in the building can reach it, along with visitors, delivery workers and anyone who has talked their way past the communal entrance. The lock, the frame and the fixings must resist a manual attack, because the door is the only barrier between the corridor and the home behind it.
The two duties pull in opposite directions. Security wants the door shut, locked and hard to open from outside. Fire safety wants it to close on its own every time, and wants the people inside to be able to get out fast. The hardware that resolves that tension is the lock and the closer working together, tested as one doorset. A lock fitted after the fire test, or a closer fitted after the security test, is a change to the tested assembly, and the evidence may no longer match. For how two ratings are proved on one doorset, see the dual certification guide, and for what the fire classifications mean, see the fire ratings page.
What the door must do in daily use
A flat entrance door is opened and shut dozens of times a day. Residents come and go with shopping, prams and children. Deliveries arrive. The door is pushed, pulled, kicked shut and held open with a foot while a bag is carried through.
The closer is the part that takes the most punishment. It must shut the door fully from any angle, every time, and it must do so without slamming so hard that it shakes the frame loose. When a closer weakens, the door stops latching, and a door that does not latch is a door that neither rating can stand behind. The closer is not an accessory. It is part of the rated assembly, and it needs the same attention as the lock.
Propping the door open is the most common way a flat entrance door fails. A wedge, a hooked-open closer or a door held on the latch lets smoke travel along the corridor and lets an intruder walk in unchallenged. Residents prop doors open for good reasons, usually because the closer is too strong or the door is heavy, so the answer is a closer that is set correctly and a door that is easy to open, not a lecture. If the door is hard to open, the setting is wrong, and it should be adjusted before someone wedges it.
Wear shows first on the seals, the hinges and the lock case. Seals harden and shrink, hinges drop, and the latch stops meeting the keep. None of this is visible from the corridor, which is why the door needs a named person checking it on a written schedule rather than waiting for a resident to report a problem. For what a check looks at, see the fire door inspection checklist, and for the choice between steel and timber leaves, see steel versus timber fire doors.
Approved Document Q and Approved Document B: the two documents that shape the door
Two documents from the Building Regulations shape a flat entrance door, and each one covers only half of the job. Approved Document Q covers security in dwellings. Approved Document B covers fire safety. A doorset that satisfies one and ignores the other is not a compliant flat entrance door.
Approved Document Q has applied since 1 October 2015 to new dwellings, including dwellings formed by a material change of use. Requirement Q1 covers easily accessible doors that provide access into a flat from the common parts of the building, which is exactly what a flat entrance door is. Secure doorsets should be manufactured to a design shown by test to meet PAS 24, or designed and manufactured to the Appendix B route in the same document. Standards that give similar or better performance are also acceptable, including LPS 1175 security rating 2 and LPS 2081 security rating B. The detail of the test and the certificates sits on the PAS 24 requirements page.
Approved Document B sets the fire side. A flat entrance door opening onto common parts is normally an FD30S doorset, self-closing, with smoke seals. The period comes from the fire strategy for the building, not from the security rating, and the two documents never trade against each other: a high security rating does not shorten the fire period, and a long fire period does not excuse a weak lock. Building control checks both, and the handover pack should hold the evidence for both.
The two documents also differ in scope. Approved Document Q applies to new dwellings, so an existing block replacing its doors is not automatically bound by it, though the replacement doors are usually specified to the same standard because the risk has not changed. Approved Document B applies to new and altered work, and the ongoing duties under the fire safety legislation apply to the building for as long as it is occupied. For the building entrance that sits below the flat doors, see the communal entrance doors guide.
The fire side: FD30S, the closer and the seals
FD30S means 30 minutes of fire integrity with smoke control. The S stands for smoke seals, which limit the leakage of cold smoke at normal temperatures, tested to BS EN 1634-3. The leaf, the frame, the intumescent strips and the cold smoke seals work as one assembly.
The self-closing device is part of the requirement, not an optional extra. Approved Document B expects fire doorsets to flat entrances to be fitted with a self-closing device, and the door must close fully into the frame from any opening angle, unaided, and latch where a latch is fitted. A closer that leaves the door standing open by a few millimetres has failed, even if it looks as if it is working. The gap matters because smoke finds gaps first, and a door that does not shut is a hole in the compartment wall.
Gaps around the leaf are kept small so the seals can do their work. A door that has dropped on its hinges, or a frame that has moved, opens gaps that no seal can bridge. The check is simple: shut the door and look at the gaps. If light shows through, the seals cannot work.
Intumescent strips expand in heat and seal the gap around the leaf. Cold smoke seals, usually a brush or fin, stop smoke before the heat arrives. Both sit in the frame or the leaf edge, and both must be the ones named in the test evidence. A seal replaced with a different profile is a change to the tested assembly. Fire rated steel doors follow the same pattern, and the fire ratings page sets out what E, EW and EI mean where the fire strategy asks for more than integrity.
Letterplates, viewers and chains in the tested doorset
A flat entrance door usually carries a letterplate, a viewer and a chain or limiter, and each of them sits inside the tested doorset. None of them is a separate product that can be swapped after the test. A letterplate cut into a tested leaf after the event is a hole in a fire door and a weak point in a security door, and the evidence will not cover it.
Approved Document Q sets the letterplate rules. The aperture must be no larger than 260 mm by 40 mm, and the letterplate must be located or designed to hinder anyone attempting to remove keys with sticks or to insert a hand, for example by incorporating a flap or other features to restrict access. The Door and Hardware Federation technical specification TS 008 is the test for letterplate security, and letterplates meeting it have been shown to protect against those attacks. A letterplate on its own cannot be a PAS 24 product, because PAS 24 tests the whole doorset. The letterplate is judged as part of the door it sits in.
Fire adds a second condition. A letterplate in a fire door must be part of the fire-tested assembly, with intumescent protection that matches the test evidence. An ordinary letterplate fitted to an FD30S leaf leaves a gap that smoke and flame can use, and the rating will not survive it.
Approved Document Q also asks for a door viewer on the main doors for entering a dwelling, unless other means exist to see callers, such as clear glass within the door or a window next to the doorset. The same doorset should also have a door chain or door limiter. The chain matters because it lets a resident open the door a little and check who is there without giving access. In sheltered housing the chain is not always appropriate, because a warden may need emergency access to residents, and in that case an electronic audio-visual door entry system can identify visitors instead.
One certificate for two ratings: what the evidence must show
Two ratings on one doorset means two sets of evidence, and both must name the same construction. The fire classification to EN 1634-1 and the security test to PAS 24 must each have been carried out on the same doorset, with the same leaf, frame, ironmongery, closer, seals, letterplate and viewer. A fire certificate for one construction and a security certificate for another do not add up to a door that carries both ratings.
The certificate must name the exact doorset, its sizes and its configuration. A certificate for a different model, a different size range or a different glazing arrangement does not cover the order, even if the product name sounds similar. The third-party listing is the record a checker asks for when the rating has to be proved, and it should be kept with the building records rather than filed with the supplier.
Ironmongery is where orders most often drift from the evidence. Every lock, closer, hinge, letterplate and viewer must be the ones named in the test evidence. A lock case changed for a cheaper equivalent, a closer swapped for a different model, or a viewer fitted in a different position can void both ratings at once. The submittal should be compared with the evidence line by line before the order is signed, and where the evidence is missing or does not match, the order should wait. For the changes that cause problems after installation, see keeping an LPS 1175 rating valid, and for the wider specification process, see how to specify security doors.
Inspection in blocks: what the 2022 regulations ask for
Once the doors are in, the law keeps watching them. The Fire Safety (England) Regulations 2022 place duties on the responsible person for the building, and flat entrance doors are named in those duties. The Fire Safety Act 2021 confirmed that the duties extend to the structure, the external walls and the flat entrance doors of a building.
In residential buildings over 11 metres, the responsible person must check communal fire doors at least every three months, and must use best endeavours to check flat entrance doors at least every year. Best endeavours means the check is attempted for every flat, and access is arranged with residents, rather than the check being skipped because a flat was empty on the day. Residents should also be given information on the importance of fire doors to the safety of the building, so that a removed closer or a wedged door is understood as a safety matter, not a housekeeping one.
The check itself is short and practical. The closer must shut the door fully from any angle and latch it. The seals must be intact, with no gaps, splits or missing lengths. The gaps around the leaf must be small and even. The leaf and frame must be free of damage, and the ironmongery must be the ironmongery named in the evidence. For the wider duties on the responsible person, see the fire door regulations guide, and for a check sheet to use on site, see the fire door inspection checklist.
What the 2022 regulations do not cover
The Fire Safety (England) Regulations 2022 set the inspection duties for flat entrance doors and communal doors in blocks. They do not set the fire rating, the door construction or the hardware. Those come from the fire strategy, the test evidence and the doorset specification, and the regulations only ask that the doors are checked.
They do not cover the flat itself. The regulations ask for checks on the communal doors every three months and on flat entrance doors every year, but the doors inside a flat are the leaseholder’s, and the responsible person cannot demand entry to check them. A flat entrance door that fails its annual check still needs the leaseholder’s agreement to fix.
They do not cover the communal areas beyond the door. A corridor with a compliant door and no working emergency lighting, no clear escape route or a blocked stair is still not safe. The regulations ask about the doors, and the fire risk assessment must cover the rest of the escape route.
They do not prove the door was right in the first place. A check records what the inspector saw: the gaps, the seals, the closer and the latch. It cannot prove the leaf, the frame and the hardware were tested together. A door that passes its checks can still sit outside its test evidence if the leaf was swapped or the hardware was changed after fitting.
They do not cover the wall beside the door. The regulations ask about the door, not the corridor wall, the head detail or the riser cupboard beside it. A flat entrance door rated FD30S in a wall that cannot hold fire for 30 minutes gives a 30 minute opening in name only. Check the wall with the door.
Mistakes that break a block-wide door order
Ordering for a whole block means ordering one doorset many times over. A mistake in the first order repeats on every floor.
| Mistake | Why it fails | What to do instead |
|---|---|---|
| One doorset ordered, many leaves fitted | A leaf fitted without its tested frame and seals is not the tested doorset. | Order the full doorset for every flat, not leaves in bulk. |
| Closer sized for a show flat | A closer that suits a light leaf will not close a heavy glazed leaf. | Size the closer to BS EN 1154 for the heaviest leaf in the block. |
| Seals left off the schedule | Intumescent and smoke seals are part of the doorset, not extras. | List the seals and the 4 mm gap on every order. |
| No record of which flat has which door | An inspection cannot check a door it cannot identify. | Record the door, the hardware and the test report by flat number. |
| Checks with no repair plan | A failed check with no repair date stays failed until the next visit. | Agree the repair date when the check is written up. |
Keep the evidence with the block. The test report, the classification and the hardware schedule should sit with the building records, so the next inspection has something to check each door against. For the checks themselves, see our fire door inspection checklist, and for the commercial rules that sit beside the 2022 regulations, see our fire door regulations for commercial buildings guide.
Ordering for a whole block: one doorset, repeated
Blocks of flats are usually ordered as a programme, not as single doors. One tested doorset, repeated across every flat, keeps the specification simple and the spares shelf short. The same lock case, the same closer, the same seals and the same letterplate on every door means one set of spares, one ironmongery schedule and one certificate to check. It also means a fault found on one door is a fault to look for on all of them.
The schedule should name everything. Leaf size and handing for each flat, the fire and security ratings, the lock and cylinder, the closer model, the seals, the letterplate, the viewer and the chain. For the mistakes that most often weaken an order, see security door specification mistakes.
Keying deserves a line of its own. Flat entrance doors in one block usually share a keying plan, so that the management key opens the common parts and each resident key opens only their own flat. The plan should be agreed before the order, with a record of which key opens which door, and a procedure for changing a cylinder when a key is lost.
Replacement cycles should be planned before the doors fail. Closers, seals and lock cases wear out well before the frame does. The handover pack should hold the certificates, the ironmongery schedule and the keying record, so that the next specifier knows what the opening was built to achieve. For the residential context, see the residential sector page and residential security doors.
| Requirement | What it means | Where it is set |
|---|---|---|
| Security | Resists manual attack to PAS 24 | Approved Document Q |
| Fire | 30 minutes integrity, FD30S | Approved Document B |
| Smoke | Cold smoke seals limit leakage, tested to BS EN 1634-3 | FD30S, Approved Document B |
| Viewer and chain | See the caller before opening the door | Approved Document Q, paragraph 1.4 |
| Letterplate | No larger than 260 by 40 mm, with a flap | Approved Document Q, paragraph 1.3 |
A flat entrance door is the compartment line for one home. If it cannot close, latch and seal, neither rating counts.
Is a flat entrance door the same as a communal entrance door?
No. A flat entrance door serves one flat from the corridor, while a communal entrance door serves the whole building from outside. The two doors answer to different threats and different hardware, and they are specified separately. For the building entrance, see the communal entrance doors guide.
Does every flat entrance door need to be a fire door?
Normally yes where the door opens onto common parts. The usual requirement is FD30S, self-closing, with smoke seals. The period comes from the fire strategy for the building and the fire risk assessment, not from the security rating.
Can one door carry PAS 24 and FD30S together?
Yes, when the exact combination has been tested on the same doorset construction. One certificate never stands in for the other. For how the two ratings are proved together, see the dual certification guide.
Who checks flat entrance doors after handover?
The responsible person for the building, under the Fire Safety (England) Regulations 2022. In buildings over 11 metres, flat entrance doors are checked at least every year on a best-endeavours basis, and communal fire doors every three months.
What happens if the closer is removed or the door is wedged open?
The fire and smoke performance is lost, because the door cannot shut and seal on its own, and the security performance goes with it, because the door no longer latches. The closer must stay fitted and the door must shut fully from any angle.