ArxBridge
Security shutters vs retractable grilles: which suits retail and commercial openings?
Security shutters or retractable grilles for retail and commercial openings? Compare ratings, appearance, noise, planning and upkeep across the UK.
- ✓Third-party test evidence with every product
- ✓Written specification you can issue to tender
- ✓Supplied and installed across the UK
Get a free project quote
Rating, written specification and budget range within one working day.
Confidential. No cost, no obligation.
Third-party tested
Evidence with every quote
UK manufactured
Made to your sizes
One accountable team
Specify, supply, install
Confidential handling
Details never shared
Choose shutters where the priority is a solid barrier and a tidy appearance; choose retractable grilles where visibility into the display matters and there is no room for a shutter box. Both can be specified to LPS 1175 ratings. The right choice follows the opening, the planning constraints and what the insurer expects to see.
- Security shuttersSolid or perforated curtain that coils above the opening
- Retractable grillesSee-through lattice that folds or slides aside
- RatingsBoth can be specified to LPS 1175 SR ratings
- PlanningExternal shutters often need permission; internal grilles rarely do
What each product is
A security shutter is a curtain of interlocking steel or aluminium slats that rolls up into a coil housed in a box above the opening. Closed, it covers the opening completely; open, it disappears into the box and the shopfront looks untouched. Slats come solid, perforated or punched, which changes how much can be seen through the closed shutter. Our security shutters page describes the build in detail.
A retractable grille is built from steel links or rods in a lattice or brick pattern that you can see through. It runs in guides and folds or slides to one side when the premises open, stacking into a fraction of the opening width. Because it does not need a coil box, it suits openings with limited headroom. Our retractable security grilles page covers the construction.
The two are sometimes combined on one site: shutters on the rear service doors where appearance matters less, grilles on the glazed frontage where the display should stay visible. Treat each opening on its own merits rather than picking one product for the whole building.
If a roller door is also on the shortlist, the comparison widens. Our guide comparing security shutters vs high performance roller doors covers speed, security and use.
LPS 1175 ratings for shutters and grilles
Both product types can be tested to LPS 1175, the LPCB forced entry standard. The rating combines a tool category letter with the minutes of resistance: A1 for basic hand tools, B3 for tools such as screwdrivers and hand saws over three minutes, C5 for crowbars and drills over five minutes, and D10 for heavy tools such as sledgehammers and disc cutters over ten minutes. Our LPS 1175 guide explains the full table.
Ask for the test evidence for the exact product and rating, not a general claim about the range. A shutter tested to C5 and a grille tested to B3 are different propositions, and the rating applies to the tested construction including its guides, locks and fixings. The rating of the curtain alone means little if the guides can be prised from the wall.
Match the rating to the threat and the location. A high street jeweller and a suburban convenience store face different risks, and the rear of a building usually needs a higher rating than the front, because attacks there go unseen for longer. Where the risk assessment is unclear, our security consultancy service can define the threat before you specify.
The shutter that must also hold fire: two proofs on one opening
A shutter and a grille guard the same frontage in different ways. The shutter covers the whole opening after hours, while the grille lets light and air through and still bars the way, so the choice follows what the frontage must do when the shop is shut. The shutters themselves are covered on our security shutters page.
Forced entry is proved to LPS 1175 for both, with B3 holding three minutes, C5 holding five minutes and D10 holding ten minutes, all under Issue 8.2, dated September 2024. The rating on the order should match the goods behind the frontage, not the shutter the catalogue shows first.
A fire shutter is not a security shutter. Where the opening needs both, the fire proof and the forced entry proof sit on separate lines, each proved on its own test, fire to EN 1634-1 and forced entry to LPS 1175, because one test report cannot prove both.
A powered shutter is a machine, and BS EN 12453 sets out how it must be made safe to use. Photocells, safety edges and loops each stop the shutter when a person or a vehicle is in its way, and a shutter without them has no proven safety at all. The rules the shutter must meet are set out in our roller shutter regulations guide.
Retractable or fixed: the grille that fits the frontage
A retractable grille folds away by day and closes tight at night, so the shop keeps its open front while it trades and its barred front after hours. The tracks, the lock and the fixings belong on the order beside the grille, because a grille that folds is only as strong as the track it runs on.
A fixed grille stays in place, so it suits a window or a vent that never opens. The frame it fixes to must hold the rating, because a grille fixed to a weak frame has no proof, and the test report must name the whole assembly as fitted.
The grille lets the shop breathe after hours, while the shutter seals it shut, so a shop that needs air through the frontage takes a grille and a shop that needs the frontage closed takes a shutter. The choice belongs on the order beside the rating, because a shutter ordered for a frontage that needs air leaves the shop to cook behind it.
Planning and conservation areas can limit what the frontage may carry. A shutter box on a listed frontage needs approval before the order is placed, so the approval belongs on the file beside the rating, and the order should wait for it.
Ask for the test report before the order is placed, with the rating, the assembly and the fixings named on the same line. A report that names the shutter alone leaves the frame and the fixings unproved, and the frontage that arrives is not the frontage that was tested. The bays that feed the frontage are covered in our loading bay doors guide.
| Product | What it guards | Rating | What to check |
|---|---|---|---|
| Roller shutter | Whole frontage | LPS 1175 B3 | Fixings, motor, safety devices |
| Retractable grille | Shopfront | LPS 1175 B3 | Tracks, lock, fixings |
| Fixed grille | Window or vent | LPS 1175 B3 | Frame, fixings |
| Fire shutter | Compartment opening | FD30 or FD60 | Seals, closer, release |
Put the product, the rating and the fixings on one schedule line, so whoever reads the file next can see what was tested and what holds it. What each step up the scale adds to the build is worked through in our roller shutter cost factors guide.
Visibility and appearance after hours
This is where the two products differ most. A closed solid shutter blanks the shopfront completely: nothing can be seen in, and the street loses an active frontage overnight. Perforated or punched slats soften this by letting light and partial views through, so the display stays faintly visible and the frontage keeps some life.
A retractable grille keeps the window display visible after closing, which suits retailers who trade on presentation. The lattice reads as a security layer rather than a closed shop, and window lighting can stay on behind it. The trade off is that stock remains on show, so the grille must be backed by a sensible display policy: high value goods come out of the window at night.
By day the difference is smaller. A shutter hides in its box above the opening; a grille stacks to one side in a slim bundle. Both leave the trading frontage clear, though the grille’s stacked bundle and its floor track remain visible. Where the shutter box cannot be concealed, for example under a low fascia, the grille’s smaller footprint can decide the matter.
Noise, ventilation and daily use
Roller shutters make noise. The curtain rattles in its guides as it moves, and a large shutter closing at the end of the day is heard through the building. Perforated slats tend to run louder than solid ones, and a shutter that is slightly out of adjustment gets louder still. In flats above shops this matters, and it is worth raising at the survey.
Grilles run quieter because there is less metal moving in guides, and they need less headroom to operate. Ventilation is another practical difference: a closed solid shutter seals the opening, while a grille lets air move through, which helps where the opening also serves as ventilation for the space behind. The comparison table below summarises the practical points.
| Aspect | Security shutters | Retractable grilles |
|---|---|---|
| Visibility after hours | Solid slats block the view; perforated slats allow partial views | Display stays visible through the lattice |
| Appearance by day | Curtain hidden in the coil box above | Grille stacks to one side in a slim bundle |
| Headroom needed | Room for the coil box above the opening | Little headroom; needs stacking space at the side |
| Ventilation when closed | Solid curtain seals the opening | Air moves through the lattice |
| Noise in operation | Audible rattle in the guides | Quieter in daily use |
| Test evidence | Ask for the LPS 1175 rating on the test certificate | Ask for the LPS 1175 rating on the test certificate |
Planning permission and conservation areas
External shutters often need planning permission, and in conservation areas or on listed buildings the planners take a close interest. Councils generally dislike solid shutters that blank off shop windows outside opening hours, because a row of closed shutters deadens the street. Perforated shutters or internal grilles are usually received better, but every authority applies its own policy, so check before ordering.
Internal grilles and internal shutters rarely need planning permission, since they do not alter the external appearance of the building. Listed building consent is a separate question and can still apply to internal work. If the building is listed, assume consent is needed and confirm it early.
Fit the product inside wherever the opening allows it. An internal shutter or grille is out of the weather, out of reach of graffiti, keeps the shopfront looking like a shopfront, and sidesteps most planning objections in one move. External mounting is for openings with no internal room for the coil or the stack, or where the glass itself must be protected from impact.
Insurance and test evidence
Insurers take an interest in physical security, and some policies name the standard the products must meet. Read the policy wording before specifying: it may ask for products tested to a named standard such as LPS 1175, and it may set a minimum rating. Specifying above the minimum is straightforward; discovering the requirement after installation is not.
Keep the test evidence with the policy documents. The certificate should name the product, the standard and the rating achieved, and it should come from third party testing, not from the manufacturer’s own claims. Photographs of the installed product, showing the guides, locks and fixings, complete the file.
An insurer may also ask about the alarm and how it interacts with the shutter or grille. An internal grille works well with an alarm: the intruder must break glass first, which triggers the alarm, and still faces the grille. Tell the insurer how the layers work together rather than listing products in isolation.
Fit inside where you can. An internal shutter or grille avoids most planning objections, stays out of the weather and works with the alarm instead of against it. External mounting should be the exception, not the default.
Operation, maintenance and the glass behind
Both products are used daily, sometimes several times a day, so the operation must suit the staff. Manual shutters need a steady pull and a working lock; anything stiff gets left half open. Electric operation with a key switch or remote suits large or heavy curtains and removes the excuse for leaving the shutter up. Grilles are lighter to move by hand, but the lattice must run freely in its tracks.
Maintenance is simple but regular: keep guides and tracks clear of debris, check the locks, and have the curtain or lattice inspected at planned intervals. Maintenance covers shutters and grilles alongside doors and gates, and is done by our own team or by our installation partners. A shutter that is serviced lasts; one that is ignored gets noisy, then stiff, then stuck.
Remember what each product does not do. A grille stops entry but does not protect the glass: a thrown object can still reach the window through the lattice. Where the glass itself must survive impact, the glazing needs its own specification, and our security windows page explains the options. In retail projects the glass, the grille and the alarm should be specified as one layered design, not three separate purchases. In hospitals the clinical rooms need a different kind of enclosure altogether, covered in our guide to MRI and RF shielded rooms; and where the opening protects people rather than stock, for example a staff refuge, see our guide to safe room and panic room doors. You can browse all our guides for related reading.
Safety and maintenance rules apply however the opening is secured. Our guide to roller shutter regulations in the UK covers powered doors, safety devices and servicing.
Frequently asked questions
Do I need planning permission for a security shutter?
Often, for an external shutter, and especially in conservation areas or on listed buildings. Internal shutters and grilles rarely need planning permission, though listed building consent can still apply. Check with the local authority before ordering.
Can a grille be as strong as a shutter?
It can carry the same kind of rating. Both product types are tested to LPS 1175, so compare the ratings on the test certificates rather than assuming the solid product is stronger. The fixings and guides matter as much as the curtain or lattice.
Do shutters or grilles stop the glass being broken?
A solid shutter protects the glass behind it; a grille does not, because objects can pass through the lattice. If the glazing itself must resist impact, specify the glass separately.
How noisy are roller shutters in daily use?
Audibly. The curtain rattles in its guides, and perforated slats run louder than solid ones. In buildings with flats above, raise noise at the survey and keep the shutter adjusted and serviced.
What maintenance do shutters and grilles need?
Keep guides and tracks clear, check locks regularly, and have the product inspected at planned intervals. Daily-use products that are ignored become stiff and unreliable.
Get a free quote
Related
More in guides for specifiers
Products
One supplier for the whole building envelope
Ready to specify your project?
Free assessment, written specification and test evidence. Reply within one working day.