Certified physical security

ArxBridge
Red-brick warehouse conversion with a navy steel entrance door in Manchester

Security · LPS 1175 SR2 to SR5

Security Doors in Manchester

Security doors for Manchester offices, warehouses and logistics yards: ratings, gates and yards, fire and security on one doorset, and the order.

  • ✓Third-party test evidence with every product
  • ✓Written specification you can issue to tender
  • ✓Supplied and installed in Manchester
Prefer to talk?+44 7352 267239

Get a free quote in Manchester

Rating, written specification and budget range within one working day.

ArxBridge Quote Form

Confidential. No cost, no obligation.

Third-party tested

Evidence with every quote

UK manufactured

Made to your sizes

One accountable team

Specify, supply, install

Confidential handling

Details never shared

Supplied and installed in Manchester

What we supply in Manchester

More on this

A Manchester buyer should start from the opening, not the catalogue. A rated steel door at B3 or C5 suits most warehouse and office entrances, a fire rated doorset suits any escape route, and a gate beside the yard needs its own rating.

Manchester holds offices in the city centre, warehouses and logistics yards on out-of-town sites, and each kind of site asks a different question of its doors. A warehouse needs a steel personnel door that takes a forklift, a pallet and a shift of workers every day. A logistics yard needs a gate, a turnstile lane and a door that guards the stores behind them. A city centre office needs an entrance that admits a crowd and lets it out fast.

The answer is a door schedule with one line per opening. Each line names the building, the position, the fire rating, the security rating where one is needed, and the leaf, the frame, the glass, the seals and the hardware as one doorset. Our Manchester page covers the city as a whole, and our Liverpool page covers the city to the west.

  • LPS 1175Forced entry rating, B3 to D10
  • ISO 22343-1Vehicle impact test for gates and yards
  • FD30 / FD60Fire resistance periods tested to EN 1634-1
  • BS EN 1935Hinge grades 13 and 14 for heavy leaves

Warehouses and logistics yards: the buildings that set the brief

A warehouse is a building where the door takes daily use and the stock inside is worth protecting. Staff come and go through the personnel door, deliveries arrive at the side door, and the rear door faces a yard that is quiet after hours. A door on a warehouse must resist a forced entry from a quiet side and still open easily for the people who use it every day.

A logistics yard runs to a different rhythm. Lorries arrive and leave through the gate, staff pass through the personnel door at every shift change, and the stores behind the door hold goods in transit. A personnel door on a yard needs a rating that suits the approach it faces. Our warehouses and logistics sector page covers the buildings that hold the stock.

City centre offices: doors that take a crowd and let it out

A city centre office in Manchester meets the public every day, and its entrance doors must admit staff and visitors and keep strangers out. A glazed entrance lets reception see who is at the door before it is opened, and a rated screen holds while the door is checked. A screen that is not rated is a screen that fails at the first blow, and the entrance behind it is open. Our fire rated windows guide sets out how glass, frame and beads are tested together.

The same doors must release a crowd in one action if the alarm sounds. Panic hardware to BS EN 1125 belongs on these doors, with a bar across the leaf covering at least 60 percent of the leaf width, on doors that serve more than 60 people. A door must open with less than 30 N in the first 30 degrees and less than 22.5 N beyond that, under BS 8300 and Approved Document M. Premises that hold crowds face duties under Martyn’s Law, which sets tiers for premises that hold 200 or more people, with Royal Assent in April 2025 and go-live expected in spring 2027. Our Martyn’s Law guide sets out the tiers and what they ask of a premises.

Need this specified for your project?Free rating, written specification and budget range within one working day.
Get a free quote

The Etihad Campus and the AO Arena: doors for event crowds

The Etihad Stadium stands in east Manchester, built for the 2002 Commonwealth Games, and holds 53,400 people. Co-op Live stands beside it on the Etihad Campus, opened on 14 May 2024, and holds 23,500 people with standing, which makes it the largest indoor arena in the United Kingdom. The AO Arena stands above Manchester Victoria station, just north of the city centre, and holds 21,000 people. Three large venues in one city put crowds through their doors in waves, before an event starts, at the break and when it ends.

Doors at the Etihad Campus and the AO Arena work in two directions. Before an event they admit a crowd at walking pace, and at the end they must let the same crowd out fast, without a key or a code. Where a room holds more than 60 people, its doors need panic hardware to BS EN 1125, and the push bar must cover at least 60 percent of the leaf width. Co-op Live holds 23,500 people, so it sits in the enhanced tier of Martyn’s Law, which covers premises that hold 800 or more people. The Act received Royal Assent in April 2025. The Security Industry Authority expects it to come into force in spring 2027. See the Martyn’s Law guide for premises, which covers the tiers in full.

A wide leaf on an arena exit needs a closer sized for its mass and its traffic. Door closers take their power sizes from BS EN 1154, and EN 3 is the smallest size for a fire door. A closer below EN 3 cannot shut the leaf against its seals, and a closer set too strong fails the opening force test. BS 8300 and Approved Document M keep the force to open a door below 30 N for the first 30 degrees, then below 22 and a half newtons after that. The stadium security doors guide works through arena and stadium doors.

Building Door Rating to name
Etihad Stadium Turnstile and concourse entrances Panic hardware to BS EN 1125
Co-op Live Concourse and exit doors BS EN 1125 panic hardware
AO Arena Arena exit doors BS EN 1154 closer, EN 3 minimum
Manchester Royal Infirmary Ward and entrance doors Fire to EN 1634-1 with low opening force

Oxford Road: university and hospital doors in constant use

Oxford Road runs south from the city centre past the University of Manchester and Manchester Metropolitan University, and on to Manchester Royal Infirmary. The infirmary stands on its Oxford Road campus in central Manchester, where it shares a site with the Royal Manchester Children’s Hospital, the Manchester Royal Eye Hospital and Saint Mary’s Hospital. A campus door and a hospital door both work from early morning to late evening, and both must still latch, lock and release when needed.

Hospital doors on Oxford Road divide into two kinds. Public doors in the main entrance stay in use around the clock, while ward and plant room doors stay closed and locked. A ward door must shut on its own and hold fire for its rated period, and it must still open with a push a patient can manage. Ward and plant room doors that lock by key need a cylinder that stands up to snapping and picking. TS 007 tests the cylinder and the handle as a pair. A 1 star cylinder and a 2 star handle together make a 3 star door. Write the stars on the schedule, because the set is only as strong as its weakest part. The hospital security doors guide gives ward and department doors in full, and the university security doors guide explains campus doors in full.

Write the Etihad Campus, the AO Arena and Oxford Road into the same door schedule as the offices and the warehouses. Put one rating beside each opening, and file the evidence with the doors when they arrive.

What a rating means for a Manchester buyer

LPS 1175 rates a doorset by the tools and the time it resists. B3 is three minutes against category B tools, screwdrivers, pliers and hand saws. C5 is five minutes against category C tools, crowbars, drills and chisels. D10 is ten minutes against category D tools, sledgehammers, disc cutters and jigsaws. The old labels still appear on drawings and certificates: SR2 is the old name for B3, SR3 is the old name for C5, and SR4 is the old name for D10.

The rating should follow the risk, not the postcode. A warehouse door that guards stock and equipment needs a forced entry rating to LPS 1175 or PAS 24, on the whole doorset, while a corridor door in the same building may need none. Walk the site from outside and note every door a person can reach, then rate those doors for the attack they could face. Our keeping an LPS 1175 rating valid guide sets out the changes that void a rating, and our LPS 1175 vs PAS 24 guide compares the two routes side by side.

PAS 24 is the enhanced security standard for doorsets, and EN 1627 sets resistance classes RC1 to RC6. Secured by Design is a scheme, not a rating, and a door that carries the scheme mark without a test rating has no proven resistance behind it. Our SR2 vs SR3 vs SR4 guide works through the three ratings buyers meet most often.

Fire and security on one Manchester doorset

Many doors in Manchester must do two jobs: hold fire and resist forced entry. A server room door must hold fire and resist an attack on the equipment inside, and a plant room door must hold fire and resist a forced entry. The two jobs need two sets of evidence on one assembly, and a change to the leaf, the frame, the glass, the seals or the hardware can break the tested construction. Ask for the evidence when a change is proposed, not after it is made. The test report, the classification and the hardware schedule should name the exact doorset.

FD30 and FD60 are fire resistance periods tested to EN 1634-1, and the number is the minutes the doorset holds its rating in the furnace test. A door marked FD30S carries 30 minutes of integrity plus smoke control, tested to BS EN 1634-3. Check the wall the door fixes into: a rated leaf in an unrated wall gives an unrated opening, and a frame fixed into a partition that was never built to hold it will move when the door is used. Our dual certification guide works through how fire and security sit on one assembly.

Access control across a Manchester estate

An estate that holds sites across Manchester needs one access system, not one per site. Staff carry cards, visitors use a code or a pass, and contractors use a temporary credential that expires when the work ends. Each method suits a different entrance: a warehouse needs cards that work at shift change, and an office building needs readers that work at walking pace.

The fail state must be agreed in advance and tested with the power off. A door that must stay locked for security and a door that must release for escape need different answers, and the answer should be written down where the facilities team can find it. The doors should talk to the same system as the turnstiles, the lifts and the car park, so a person who loses access loses it everywhere at once. Our security turnstiles guide works through readers, fobs and biometrics and how the lane is wired into the access system.

Loading bays, gates and the yard line

A loading bay door opens and closes all day, and the personnel door beside it lets staff in and out without opening the bay. A high performance roller door suits a busy bay, so specify the personnel door beside the bay at the same time, and the two work as one entrance. Our loading bay doors guide covers the bay doors in full.

Where the yard must stop a vehicle as well as a person, the gate needs an impact rating beside its forced entry rating. ISO 22343-1:2023 is the current vehicle barrier test standard, and it supersedes PAS 68:2013 and cancels and replaces IWA 14-1:2013. The example rating V/7500[N3]/80/90:0/0 shows the parts: the vehicle type and mass, the impact speed, the impact angle and the penetration distance. Test vehicles run from a 1,500 kg car to a 30,000 kg truck, and test speeds are 48, 64 and 80 km per hour. ProtectUK guidance sets 1,200 mm as the maximum clear gap between barriers in a line and 500 mm as the minimum height, so check the whole frontage. Our anti-ram gates and barriers guide works through the gate that closes the opening.

Planning checks with Manchester City Council

Most like-for-like door replacements inside an existing opening need no planning permission, but three cases need a check with Manchester City Council before ordering. First, major alterations to the outside of a building, including a new opening or a changed frontage, can need planning permission. Second, work in a conservation area faces additional controls. Third, listed buildings need separate consent, and this is the case buyers miss most often.

Get the consent before the order, not after it. A listed building carries duties a new building does not, and a door fitted without the right consent can be ordered out again. Ask the conservation officer what the facade will accept, and put the time the consent takes in the programme from the start. A door ordered before the planning is settled is a door that may never be fitted.

One concierge desk stands between a tower and the street

Deansgate Square South Tower stands on the southern edge of Manchester city centre, 201 m tall with 65 floors, completed in 2018, the tallest building in the United Kingdom outside London. Beetham Tower stands at 301 Deansgate, 169 m tall with 47 storeys, completed in 2006, with a hotel up to level 22 and apartments above. No. 1 Spinningfields, between Deansgate and the River Irwell, is a 92 m office tower completed in March 2018. The entrance pattern is the same in all three: a concierge desk, a controlled lobby, and a lift lobby behind it.

The concierge desk is the control point for a residential tower. Visitors are checked at the desk and parcels are held at the lobby. The shared entrance doorset must resist attack from the street, so name a rating to LPS 1175 or PAS 24 on the whole doorset, not on the leaf alone. A staffed front entrance suits B3, and a rear door that faces a quiet approach suits C5. The residential security doors page sets out the ratings for flat entrances, and the security turnstiles guide works through the lane a busy lobby needs.

Behind the lobby, the lift lobby doors hold fire while residents pass through them all day. Give those doors an FD30 or FD60 rating to EN 1634-1, and check the closer shuts the leaf against its seals. In Beetham Tower a hotel sits below and apartments above, so the guest room doors and the flat doors each need a fire period and a lock that suits the people behind them. The hotel security doors guide covers guest room and corridor doors.

Building Door Rating to name
Deansgate Square South Tower Shared entrance LPS 1175 B3 or C5 where rated
Beetham Tower Hotel and apartment doors FD30 or FD60, EN 1634-1
No. 1 Spinningfields Lobby and lift lobby Speed gate lane, LPS 1175 where rated
Murrays’ Mills, Ancoats Mill entrance and flat doors FD30, listed consent first

A listed mill opening accepts a rated doorset only on the conservation officer’s terms

Murrays’ Mills stands in Ancoats, next to the Northern Quarter, on the northern side of Manchester city centre. Old Mill was begun in 1797 and is the world’s oldest surviving urban steam-powered cotton spinning factory, and Old Mill and Decker Mill are listed at Grade II*. Ancoats was designated a conservation area in June 1989. A mill of that age holds openings a modern tower never has: wide brick arches and deep reveals. Each opening takes a doorset built for its own size, and none of them can be widened or cut without consent.

Order the doorset to the opening, never the opening to the doorset. A steel leaf in a listed mill facade needs a finish and fixings the conservation officer accepts, with a fire period to EN 1634-1 on the same assembly. A flat door in a converted mill must shut on its own, hold fire for its rated period, and still open with a push a resident can manage. Consent and fire ratings in old fabric are worked through in the listed building fire doors guide, and the residential sector page sets out the doors a block of flats needs.

The ground floor of a converted mill often holds a cafe or a restaurant beside the flats, so the commercial door and the residential door in the same facade need different answers. The commercial door faces the street all day, while the flat doors behind it need a fire period and a lock for the people who live there. The restaurant security doors guide covers the ground floor doors in full. Name the building, the opening and the listing, and order the rating and the hardware for what that door will face.

What the enquiry should name for a Manchester site

Ordering doors for a Manchester site is a specification exercise, not a shopping exercise. The enquiry should name the building, the position, the fire rating, the security rating where one is needed, and the leaf, the frame, the glass, the beads, the seals and the hardware as one doorset. The security side needs its own evidence where the door must also resist attack: a rating to LPS 1175 or PAS 24, on the whole doorset, not on the leaf alone. Where the site needs a gate as well as doors, the enquiry should name the gate type, the width and the impact rating where one is needed. Our how to specify security doors guide covers the same discipline column by column.

Order the evidence with the doors. The test report, the classification and the hardware schedule should arrive with the doorset, and the handover pack should name the inspection routine the site will follow. A site that files the evidence on the day the doors arrive has a record it can use for the whole life of the estate. Write the schedule first, then order against it. Our security door cost factors guide covers the factors behind a quote, and our fire door inspection checklist gives the checks that catch a failing leaf before it matters.

Premises Door position Rating What to check
Warehouse unit Personnel door LPS 1175 B3 or C5 Steel leaf, hinges, latch
Logistics yard Vehicle and pedestrian gates ISO 22343-1 where rated Posts, foundations, gaps
City centre office Escape and entrance doors FD30 or FD60 Panic hardware, opening force
Stores and plant room Internal doors FD60 Seals, gaps, self-closing

In Manchester, the door that suits a warehouse does not suit a city centre office, and the yard that stops a person but not a vehicle has a gap in its line.

What LPS 1175 rating do I need for a Manchester warehouse door?

For most warehouse entrances, B3 suits a staffed front entrance and C5 suits a rear or side door facing a quiet approach. The rating should follow the risk assessment for that opening.

What impact rating does a Manchester yard gate need?

Where the yard must stop a vehicle, the gate needs a rating to ISO 22343-1:2023, with a test report for the leaf, the posts and the foundations. A rating string alone is not evidence.

Can a fire exit door also be a security door?

Yes, where the same doorset carries both ratings and the escape hardware opens in one action from the inside, with no key and no code.

Do I need planning permission to replace a door in Manchester?

Most like-for-like replacements inside an existing opening need none, but a new opening, work in a conservation area, or work to a listed building needs a check with Manchester City Council before ordering.

What should a Manchester yard enquiry name?

Name the gate type, the width, the impact rating where one is needed, and the leaf, the posts, the fixings, the foundations, the operator and the access control as one system.

For a building with more than one opening, our enquiry checklist for security doors sets out the rating, hardware and evidence to name for each door.

Specifying doors for a Manchester site?Send the door schedule and the fire strategy for a tested doorset quotation.
Get a free quote

Ready to specify your project?

Free assessment, written specification and test evidence. Reply within one working day.