Security · LPS 1175 SR2 to SR5
Security Doors in Cambridge
Security doors in Cambridge for colleges, hospitals and offices, with LPS 1175 grades, fire classes and access that suits daily use and opening force.
- ✓Third-party test evidence with every product
- ✓Written specification you can issue to tender
- ✓Supplied and installed in Cambridge
Get a free quote in Cambridge
Rating, written specification and budget range within one working day.
Confidential. No cost, no obligation.
Third-party tested
Evidence with every quote
UK manufactured
Made to your sizes
One accountable team
Specify, supply, install
Confidential handling
Details never shared
Supplied and installed in Cambridge
What we supply in Cambridge
One Cambridge entrance gets one security door, and the lock, the leaf, the frame and the glazing suit the risk found at that entrance. One written specification sets the rating for the whole doorset, and that rating fits the building the door guards. Security doors are built to a named grade, and no order goes out until the specification names the grade.
Students, staff and visitors move through the doors of the University of Cambridge colleges from morning to night, while at Addenbrooke’s Hospital a ward door must open fast for trolleys and shut firm behind them. On Cambridge Science Park, offices and laboratories need doors that follow staff routes and the flow of deliveries, and the city centre and the railway station keep people moving through halls where the exits must stay clear. Each place needs a doorset that fits its own risk and the traffic through it.
Each door job starts at the opening, where the survey looks at the traffic, the wall and the risk, and the visit leaves a written specification naming the hardware, the leaf and frame, and the grade. The Cambridge order rests on that document, and the physical security in Cambridge page sets out the wider range across the city. A written reply follows within a working day.
Doorset built for the risk at its own Cambridge opening
A hospital ward door in Cambridge answers a different risk from a college entrance door, and the choice follows the risk at that one opening. The core sits in the leaf and the frame keeps the leaf true; the ratings for lock, hinges and glazing all come from that same document. Where a door must stop a bullet, the leaf and the glazing need matching ratings, so the glass grade stands beside the door grade in the specification. The hospital security doors guide covers the balance between opening fast for trolleys and shutting firm behind them, and the university security doors guide shows what a doorset faces from students and staff each day.
At the railway station, doors hold staff routes apart from the routes travellers use through the public areas. The transport hub security requirements guide has a section on those staff entrances. Offices round the Science Park need doors that let staff in and out without holding up the working day, and the grade for each door follows its own entrance. The office security doors guide and the retail security doors guide cover those working entrances, and the school security doors guide covers doors for teaching buildings.
Grades a Cambridge buyer should ask for
The buyer plans LPS 1175 Issue 8.2 (September 2024) planning each grade from what the survey found at the opening, not from a catalogue line. Grades span A1 through H20, and the four named ratings carry one, three, five and ten minutes in that order, from SR1 to SR4. The risk assessment at the opening sets the grade for a door under a forced entry risk, and the specification carries that grade before any order goes out.
PAS 24 covers homes only, so a Cambridge buyer fitting doors for a college, a hospital or an office should not ask for it there. The RC1 to RC6 scale for forced entry comes from BS EN 1627:2021, and BS EN 1522 and EN 1523 cover doorsets from FB1 to FB7. EN 1063 sets the glass rating, BR1 to BR7. BS EN 1634-1:2014+A1:2018 anchors the fire test for the doorset and the frame it sits in. E, EW and EI appear on the fire ratings page, each with its minutes, 30 to 120. Where a doorset stands beside a fire escape route, it may also need a fire rating, and the page for fire rated steel doors in Cambridge shows the doorset that carries it.
What each Cambridge building asks of its doors
| Cambridge place | Door | What the survey checks |
|---|---|---|
| University of Cambridge colleges | Doors for college entrances and stair halls | Daily use by students and staff, with hinges and locks picked for that traffic |
| Addenbrooke’s Hospital | Doors for wards, clinics and departments | Porters and trolleys moving fast, with the door opening fast and shutting firm |
| Cambridge Science Park | Doors for offices and laboratories | Staff routes kept apart from visitor routes at each entrance |
| City centre | Doors for shops and public rooms | Entry control at each door without slowing the working day |
| Railway station | Doors for staff routes and service areas | Routes for staff kept apart from the public areas where travellers pass |
Five Cambridge places fill the table above, with a door and a survey check for each. At each place, the survey notes the size of the opening, the traffic and the wall, and those notes alone shape what the specification says for that place.
Martyn’s Law and the public premises of Cambridge
Cambridge premises that hold large numbers of people will fall under Martyn’s Law. Two hundred people mark the low end of the standard tier and 799 the high end, while 800 people and more put premises at enhanced tier level. The Security Industry Authority is due to take on regulation, and the scheme is planned to begin in spring 2027.
Settle the headcount before the specification is written: the number of people sets the tier, and each entrance takes its duties from that tier. Duties of each tier are laid down in the Martyn’s Law premises guide. Headcounts for each tier are stated in the Martyn’s Law standard. The other Cambridge entrances are covered by bullet resistant windows in Cambridge, blast resistant doors in Cambridge and fire rated steel doors in Cambridge.
Access, opening force and daily use
A door that opens hard fails the people who use it most. Past the first 30 degrees the limit drops to 22.5 N, while BS 8300 and Approved Document M allow 30 N up to that point. The access control doors guide shows how entry control sits with the doorset, and the school security doors guide covers doors for teaching buildings where children and staff pass all day.
A college door sees students with bags and books all day, a hospital door sees trolleys and beds, and a station door sees travellers with luggage. Each one needs hinges, closers and locks picked for that traffic, and the specification names the leaf, the frame and the hardware as one unit. The maintenance service in Cambridge looks after the doorsets once fitting ends.
How the work moves from survey to fitting in Cambridge
The job runs in sequence: survey, rating, written specification, supply, then fitting. Each opening is measured for width, wall, traffic and risk, and those notes grow into the specification. That list gives the hardware, the grade, the leaf and the frame, and fitting holds off until it is complete. Design in Cambridge writes the specification for the building, and manufacture in Cambridge builds the doorset from that specification.
Email [email protected] continuing the sizes, the wall type and the grade you need, and the answer in writing will set out what happens next.
Put the drawings for each opening in a satchel Saffron Road, Romford, Essex RM5 3ES. Post again if the drawings do not arrive, and the survey will be booked from the copies that reach us.
Before anything is ordered, the written specification lists the glazing rating, the grade and the hardware, and each one must suit the opening on the survey.
What Cambridge buyers ask before they order
What grade should a Cambridge security door hold?
The risk assessment at the entrance decides the grade, with A1 at the bottom and H20 at the top. The four ratings run one minute, three minutes, five minutes and ten minutes, SR1 to SR4 in that order. The grade stands in the specification before the order goes out.
Does PAS 24 cover a Cambridge college or office door?
No. PAS 24 covers homes only, so a college, a hospital or an office door takes its grade from LPS 1175 instead. The specification names the grade for each opening, and the risk at that opening sets the rating.
Can a security door hold a fire rating as well?
One doorset can carry the fire rating and the forced entry grade together when the specification names both. Fire ratings run 30 minutes to two hours. Beside the fire class in the same specification sits the forced entry grade, so one door meets both ratings.
How soon does a written quote for Cambridge security doors arrive?
The surveyor notes the opening, the traffic, the wall and the risk, and the specification follows those notes. The written answer comes to you inside one working day.
Ask about security doors for your Cambridge building
Give the sizes of the doors and of each opening, and the written quote will name grade, glazing and fitting. Get a free quote
Other areas
Security doors in other areas
Ready to specify your project?
Free assessment, written specification and test evidence. Reply within one working day.