Certified physical security

ArxBridge
Quayside offices and navy steel entrance door beside the Tyne in Newcastle upon Tyne

Security · LPS 1175 SR2 to SR5

Security Doors in Newcastle upon Tyne

Security doors for Newcastle offices, retail parks and industrial estates: ratings, fire and security on one doorset, and what the order must name.

  • ✓Third-party test evidence with every product
  • ✓Written specification you can issue to tender
  • ✓Supplied and installed in Newcastle upon Tyne
Prefer to talk?+44 7352 267239

Get a free quote in Newcastle upon Tyne

Rating, written specification and budget range within one working day.

ArxBridge Quote Form

Confidential. No cost, no obligation.

Third-party tested

Evidence with every quote

UK manufactured

Made to your sizes

One accountable team

Specify, supply, install

Confidential handling

Details never shared

Supplied and installed in Newcastle upon Tyne

What we supply in Newcastle upon Tyne

More on this

A Newcastle buyer starts with the building and the door in front of them. A rated steel door suits the entrance of a Quayside office, a fire rated doorset belongs on the escape route of a retail park unit, and a yard gate at an industrial estate needs a rating of its own.

Newcastle upon Tyne stands on the north bank of the Tyne, and its buildings mix offices on the Quayside, shops and leisure in the city centre, and industrial estates along the river and at Team Valley. Each kind of building asks its doors a different question. An office entrance must admit staff and visitors all day, a retail unit must release a crowd when the alarm sounds, and a distribution yard must take forklifts and pallets without wearing out.

Put the order together as one schedule, a line for every opening, naming the building and the position, the fire period and the security rating where one is needed, and the leaf, frame, glass, seals and hardware as a single tested doorset. Our Newcastle upon Tyne page covers the city as a whole, and our Leeds page covers the nearest large city to the south.

  • LPS 1175Forced entry rating, B3 to D10
  • PAS 24Enhanced security doorset standard
  • FD30 / FD60Fire resistance periods tested to EN 1634-1
  • ISO 22343-1Vehicle impact test for gates and yards

Offices on the Quayside: doors that face the river and the street

Quayside offices meet the public from two sides: the river walk on one side and the street on the other. The entrance has to let staff and visitors through at a steady pace while keeping strangers out of the floors above, and glazing lets reception see who stands outside before the door is opened. A rated screen behind the glass holds if a visitor turns hostile, while a screen with no rating gives way at the first blow and leaves the entrance behind it open. How glass, frame and beads are tested together as one assembly is set out in our fire rated windows guide.

River air brings damp and salt to a Quayside door. A galvanised leaf carries a zinc coat that guards the steel at the edges and cut sections, and a powder coated top coat over a galvanised base gives the door colour as well as protection. Ask whether the tested doorset allows the finish before ordering, because a finish applied outside the tested construction can break the rating it was meant to protect.

Retail parks and the night-time economy: doors that work after dark

Retail parks and leisure buildings stay open late, and their doors work hardest after dark. The front door takes shoppers and staff through the day, the escape doors must release a crowd in one movement when the alarm sounds, and the rear door faces a quiet yard where nobody watches it.

Premises that hold crowds fall under the duties of Martyn’s Law, which sets tiers for premises holding 200 or more people, with Royal Assent in April 2025 and go-live expected in spring 2027. Doors on an escape route must open in one action, in the direction of escape, without a key, so panic hardware to BS EN 1125 belongs on them where they serve more than 60 people, with the bar spanning at least 60 percent of the leaf width. Our Martyn’s Law guide sets out the tiers and what they ask of a building.

Need this specified for your project?Free rating, written specification and budget range within one working day.
Get a free quote

St James’ Park: doors that hold a matchday crowd

St James’ Park stands in the heart of Newcastle city centre and has been the home of Newcastle United since 1892. The ground holds 52,305 people, which makes it the largest football stadium in the north east of England. A crowd of that size moves through the same doors before a match and again at the end, so the concourse doors and the turnstile-line doors work harder than any door on an office floor. The doors the crowd passes through need hardware sized for that traffic.

On a matchday the exits carry the whole stand at once, and the doors must let everyone out without a key, a code or a second move. Panic hardware to BS EN 1125 fits that job: a push bar across at least 60 percent of the leaf width, so a person pressed against the door in a crowd can still open it. Martyn’s Law puts the ground in the enhanced tier, because more than 800 people may be present. The Terrorism (Protection of Premises) Act 2025 received Royal Assent in April 2025, and its standard tier covers 200 to 799 people, while its enhanced tier covers 800 or more. For the doors a ground orders on a matchday, the stadium security doors guide sets out the turnstiles, concourses and exits together, and the Martyn’s Law guide for premises covers the tiers and the duties that sit beside them.

An evening match adds a second test, because the crowd leaves in the dark. Turnstile doors and exit doors must open outward in the direction of escape, and the route beyond them must stay clear. The fire door regulations for stadiums guide covers escape routes and fire periods on a ground.

Newcastle universities and hospitals: doors in daily use

Newcastle holds two universities close to the city centre. Newcastle University traces its origins to a School of Medicine and Surgery established in 1834, and became a university in its own right in 1963. Its campus sits close to Haymarket, between Leazes Park and the Town Moor, and its medical school stands beside the Royal Victoria Infirmary. Northumbria University gained university status in 1992, and its City Campus is the main site in the city centre. Lecture rooms fill and empty between classes all day, so a theatre door must clear a full room fast when the alarm sounds. Campus doors are ordered from the university security doors guide.

The Newcastle upon Tyne Hospitals NHS Foundation Trust runs its acute services from the Royal Victoria Infirmary and the Freeman Hospital. The Royal Victoria Infirmary stands in the city centre, and the Freeman Hospital stands at High Heaton, to the east of the city. The Royal Victoria Infirmary site holds the emergency centre and the children’s hospital, while the Freeman site holds surgical services and the cancer centre. One leaf on a hospital must do three jobs at once: hold back fire for its rated period, resist a forced entry attempt where the room behind it needs it, and still open under a light push from a patient or a visitor. Put the fire class and the forced entry class on the same tested assembly. The hospital security doors guide covers hospital doors, and the fire door regulations for hospitals guide gives the fire periods.

Eldon Square sits in the city centre and opened on 4 March 1976, on the site of Old Eldon Square. It holds more than 140 units, so its entrances take the public all day. A rear door faces an approach where an attacker gets more time unseen. LPS 1175 C5 suits a rear door on a quiet approach, while LPS 1175 B3 suits a staffed front entrance.

Building Door Rating to name What to check
St James’ Park Stand exit doors Panic hardware to BS EN 1125 Bar width, one action release
Royal Victoria Infirmary Ward and store doors FD60 and LPS 1175 where rated Both proofs on one doorset
Eldon Square Rear service door LPS 1175 C5 Lock and fixing inside the tested design

Industrial estates and distribution: the doors that take the shift

A personnel door on a Newcastle industrial estate opens at every shift change, at every delivery and at every break, and a door made for a quiet office will not last on a unit floor. Forklifts, pallets, trolleys and boots strike the same leaf day after day, so the leaf, the hinges and the latch have to be built for that traffic.

Steel takes the knocks, but a strong leaf on its own is not a rated door. The rating sits on the whole assembly that was tested, leaf, frame, fixings, glazing and hardware together, so a rated leaf in an untested frame carries no rating at all. Change any part of the assembly for something untested and the construction that passed the test no longer exists. Our warehouse security doors guide covers the doors distribution buildings need most.

When the shift changes, every personnel door earns its keep

Shift change is the hardest hour on an industrial estate. One crowd walks in while another walks out, and every one of them passes through the same personnel doors. A door that sticks, a closer that lets it stand open and a lock that needs two turns all slow the changeover, and the queue that forms at the door is the first sign the hardware is losing the day.

The personnel door at the gatehouse takes every arrival, so its closer and its hinges are set for traffic, not for a quiet office. BS EN 1154 sizes closers from EN 1 to EN 7, and the power must pull the door shut after each person without slamming it into the frame. Under BS 8300 and Approved Document M the push stays under 30 N through the first 30 degrees, then under 22.5 N beyond them, so a worker carrying a bag can still open it one handed.

Where more than 60 people pass one door at a changeover, the release must work at a single push. Panic hardware to BS EN 1125 runs a bar across 60 percent or more of the door width, so a person pressed against it in a crowd can still get out. The panic hardware guide gives the bar, the width and the single action release.

The loading bay runs on a different clock. Lorries reverse to the dock, forklifts cross the threshold all day and the personnel door beside the bay takes the foot traffic the dock doors cannot. A steel frame holds its shape where a forklift clips the edge, and the threshold takes the wheels without rising into a trip. The loading bay doors guide covers the dock and the doors beside it, and the warehouse security doors guide covers the unit as a whole.

Door Shift-change job What wears first
Personnel door at the gatehouse Takes every arrival and every departure Closer arm and hinges
Personnel door beside the bay Foot traffic while the dock works Threshold and bottom edge
Store door Tools and stock in and out all day Lock and handle
Yard gate Lorries through the gate, staff beside it Gate hinges and the lock

Until the night lock-up, the gatehouse watches the yard

The gatehouse is the eye of the estate, and the yard gate is its hand. A pedestrian gate beside the vehicle gate keeps staff on foot apart from lorries, and the vehicle gate shuts behind each lorry rather than standing open for the next one. The security gates guide sets out the gate, the pedestrian way through and the lock that holds them.

Lock-up starts on foot, with a walk round the buildings. The last person round checks the bay personnel door, the store door and the rear door, tries each lock and writes the round down. A lock that only turns when the door is lifted has a frame out of square, and a door that will not shut has a closer past its setting. The security door locks guide gives the lock and the fixing that holds it, and the steel door frames guide gives the frame that keeps the lock true.

If the gatehouse cannot see the yard, the night lock-up starts with a walk, not a switch, and the walk starts at the gate.

B3, C5 and D10: what the rating means on a Newcastle order

LPS 1175 grades a doorset by the tools it stands up to and the time it stands up to them. Three minutes against category B tools, screwdrivers, pliers and hand saws, earns B3. Five minutes against category C tools, crowbars, drills and chisels, earns C5. Ten minutes against category D tools, sledgehammers, disc cutters and jigsaws, earns D10. Old drawings still carry the earlier labels, so SR2 is the old name for B3, SR3 is the old name for C5, and SR4 is the old name for D10.

A staffed front entrance suits B3, a rear door that faces a quiet yard suits C5, and a door guarding high value stock, a plant room or a cash handling area suits D10. PAS 24 is the enhanced security standard for doorsets, and EN 1627 gives resistance classes RC1 to RC6 for windows, doors and shutters. Secured by Design is a scheme, not a rating, so a scheme mark without a test rating behind it proves nothing about resistance. Our SR2 vs SR3 vs SR4 guide compares the three ratings buyers meet most often, and the changes that void a rating are set out in our keeping an LPS 1175 rating valid guide.

One doorset, two proofs: fire and forced entry in Newcastle

A Newcastle doorset can carry both jobs at once: holding back fire and standing up to an attack. The server room needs a leaf that keeps fire in the corridor from reaching the racks and keeps a thief from the equipment, and the plant room needs the same pair of proofs for a different risk. The fire proof is a classification to EN 1634-1, the forced entry proof is a rating to LPS 1175 or PAS 24, and each one has to name the doorset that will be fitted. Our dual certification guide works through how the two sets of evidence sit on one assembly.

Fire resistance is read off the furnace test to EN 1634-1: the figure after FD is the minutes of protection, 30 for FD30 and 60 for FD60. Where smoke control is needed as well, FD30S pairs 30 minutes of integrity with a smoke seal tested to BS EN 1634-3, and the EI figure caps the heat reaching the safe side at 140 degrees Celsius on average and 180 at the hottest point. Swap the leaf, the frame, the glass, the seals or the hardware for something untested and the door holds no proven rating, whatever the leaf on its own could do.

Gates, yards and the vehicle line: stopping a vehicle at the boundary

A Newcastle yard gate that must stop a vehicle needs an impact rating, not just a strong leaf. Ask for a rating to ISO 22343-1:2023, proved by a test report for the leaf, the posts and the foundations, because the foundation in the test is part of the rating, not an afterthought. A rating string on its own is not evidence, and a gate with no test report behind it has no proven rating. Our ISO 22343 vehicle security barriers guide reads the rating field by field.

Read the rating example V/7500[N3]/80/90:0/0 field by field: the vehicle and its mass, the impact speed, the impact angle, and the penetration figures after the colon. The test catalogue runs from a 1,500 kg car up to a 30,000 kg truck, with impact speeds of 48, 64 and 80 km per hour. ProtectUK guidance caps the clear gap between barriers in a line at 1,200 mm and asks for a height of at least 500 mm. Our PAS 68 bollards guide works through the rating and what it asks of the whole line, and our road blockers guide sets out the barriers that close a vehicle route.

Newcastle City Council: planning, conservation and listed buildings

Changing a door like for like inside an existing opening usually needs no planning permission. Three cases are different, and each one needs a check with Newcastle City Council before ordering: major changes to the outside of a building, work in a conservation area, and work on a listed building, which needs separate consent and is the case buyers miss most often.

A listed building carries duties a new building never faces, and a door put in without the right consent can be ordered out again. The finish and the fixing of a steel leaf in a listed facade must be ones the conservation officer accepts, so begin the planning early and leave its time in the programme.

The Newcastle order: what the enquiry must carry

Frame the enquiry as a specification: the building and the position, the fire period and the security rating where one is needed, and the leaf, the frame, the glass, the beads, the seals and the hardware as one doorset. Where the job includes attack resistance, the LPS 1175 or PAS 24 rating has to be proved on the whole doorset, not on the leaf by itself. The same discipline, column by column, is set out in our how to specify security doors guide.

Ask for the test report, the classification and the hardware schedule to arrive with the doors, and file them on the day they arrive, so the estate holds a record it can use for the whole life of the building. The checks that catch a failing leaf before it matters are set out in our fire door inspection checklist. A closer that is too strong for the leaf makes the door fail the access rules, so the closer power size belongs on the schedule beside the rating: a door must open with less than 30 N in the first 30 degrees and less than 22.5 N beyond that, under BS 8300 and Approved Document M. Our fire door closers guide sets out the power sizes in BS EN 1154, and our security turnstiles guide covers how readers, fobs and biometrics are wired into the access system.

Premises Door position Rating What to check
Quayside office Glazed entrance LPS 1175 where rated Screen rating, reader pace
Retail park unit Front and escape doors FD30 or FD60 Closer, seals, hold-open release
Industrial estate Personnel door LPS 1175 B3 or C5 Steel leaf, hinges, latch
Distribution yard Vehicle gate ISO 22343-1 where rated Posts, foundations, gaps
Stores and plant room Internal doors FD60 Gaps, seals, self-closing

A Newcastle order that treats a Quayside entrance and a Team Valley yard gate as the same job will get one of them wrong.

What LPS 1175 rating suits a Newcastle office door?

Most office entrances take B3 at the staffed front and C5 at a rear or side door that faces a quiet approach. Let the risk assessment for that opening decide, not the rating of the door beside it.

Can one Newcastle doorset hold a fire rating and a security rating?

Yes, where one doorset carries the evidence for both. Fire is proved by a classification to EN 1634-1 and forced entry by a rating to LPS 1175 or PAS 24, and both pieces of evidence must name the doorset that will be fitted.

Do I need planning permission to replace a door in Newcastle?

A like-for-like replacement inside an existing opening usually needs none. A new opening, work in a conservation area, or work to a listed building calls for a check with Newcastle City Council first.

What finish lasts on a Newcastle door near the river?

A door that stands in damp river air suits a galvanised finish, because the zinc coat guards the steel itself, edges and cut sections included. Ask whether the tested doorset allows the finish before ordering.

How do I order doors for several Newcastle sites?

Write one schedule, one line for each opening, with the building, the position, the fire rating, the security rating and the whole doorset on it. Ask for the test evidence to arrive with the doors and file it the day they land.

Specifying doors for a Newcastle upon Tyne site?Send the door schedule and the fire strategy for a tested doorset quotation.
Get a free quote

Ready to specify your project?

Free assessment, written specification and test evidence. Reply within one working day.