Security · LPS 1175 SR2 to SR5
Security Doors in Reading
Security doors for Reading offices, business parks and Thames Valley sites: ratings, fire and security on one doorset, and what to name on the order.
- ✓Third-party test evidence with every product
- ✓Written specification you can issue to tender
- ✓Supplied and installed in Reading
Get a free quote in Reading
Rating, written specification and budget range within one working day.
Confidential. No cost, no obligation.
Third-party tested
Evidence with every quote
UK manufactured
Made to your sizes
One accountable team
Specify, supply, install
Confidential handling
Details never shared
Supplied and installed in Reading
What we supply in Reading
Start a Reading order at the door itself, with the people who use it and the risk it faces. A staffed entrance takes a rated steel door, every escape route takes a fire rated doorset, and a gate on a yard line takes a rating of its own.
Reading sits where the Thames Valley gathers its offices: business parks on the edge of town, headquarters beside the station, and distribution units along the motorway corridors. Each building asks something different of its doors.
Hold the order together with a single schedule, one line for every opening. A line names the building and the position, the fire period, the security rating where the opening needs one, and the leaf, the frame, the glass, the seals and the hardware as a single tested doorset. Our Reading page covers the town as a whole, and our Oxford page covers the city to the north west.
- LPS 1175Forced entry rating, B3 to D10
- PAS 24Enhanced security doorset standard
- FD30 / FD60Fire resistance periods tested to EN 1634-1
- ISO 22343-1Vehicle impact test for gates and yards
Thames Valley offices: the entrances a business park meets
A business park entrance works hardest at the start and the end of the day, when staff arrive in a rush and leave the same way. The door has to move that crowd through without a queue forming outside. Glazing at the entrance lets reception see a visitor before the door opens, and a rated screen behind the glass holds if that visitor turns hostile. How glass, frame and beads are tested together as one assembly is set out in our fire rated windows guide.
The pace at the reader matters as much as the strength of the leaf. A slow reader, or a door that is heavy to pull open, holds the queue back and tempts staff to wedge the door open. A closer set to the right power size shuts the door square every time without fighting the person who opens it. The power sizes in BS EN 1154 are worked through in our fire door closers guide.
Distribution units beside the motorway: doors that work all day
Reading distribution units sit beside the motorway corridors, and their doors are worked from the first delivery of the day to the last. A personnel door on a distribution unit is used at every shift change, at every delivery and at every break, so office-grade hardware will not stand up to that use. The doors distribution buildings need most are set out in our warehouse security doors guide, and the buildings that hold the stock are covered on our warehouses and logistics sector page.
The bay door and the personnel door beside it should be ordered together, not one after the other. The bay takes the vehicles and the personnel door takes the people, so staff never need to open the bay to walk in and out. A roller door that opens and closes all day suits the bay, and the personnel door beside it should be specified at the same time. The bay doors are covered in full in our loading bay doors guide.
A gate on the yard line needs a rating of its own, with the posts, the fixings and the ground beneath them part of that rating. A rated gate on untested posts is an opening with no proof behind it. Our anti ram gates and barriers guide works through what a gate line has to prove.
The dock door takes the lorries, the personnel door takes the people
Two doors carry a distribution unit through the day. The dock door works the lorries and the pallets, and the personnel door beside it works the people, from the first arrival in the morning to the last one out at night. When each door does its own job the unit runs, and when the personnel door is left to stand in for the dock the day stalls.
Morning starts at the personnel door, where staff arrive in a wave. Closers are sized under BS EN 1154, and EN 3 is the smallest power a fire door may carry. Set the power so the door shuts after each arrival without slamming, and try it from half open as well as from fully open. The fire door closers guide lists the power sizes and the way each one is set.
By midday the dock is the busy side. Forklifts cross the threshold from morning to close, and the threshold must stay level under the wheels, not rise into a trip and not wear into a hollow. A steel frame keeps its shape where a pallet clips the corner, and the dock door must shut tight once the lorry pulls away, or the unit stands open to the yard. The loading bay doors guide works through the dock, the threshold and the personnel door beside them.
The personnel door beside the dock is unwatched for much of the day, so it needs a rating that fits a quiet approach. LPS 1175 C5 suits a rear door where nobody passes after the shift, and LPS 1175 B3 suits the personnel door where staff pass all day. The security door specification mistakes guide lists the errors that put the wrong rating on the wrong door, and the warehouse security doors guide treats the whole unit, dock and personnel doors together.
| Time of day | Door at work | What to watch |
|---|---|---|
| Morning arrival | Personnel door | Door shuts after each arrival |
| Midday dock work | Dock door | Threshold level, dock door shut tight |
| Afternoon dispatches | Yard gate | Gate shuts behind each lorry |
| Close and lock-up | All doors and gate | Each lock tried by hand |
Lock the yard gate last, and walk the round first
Close begins on foot. The last person round tries the dock door, the personnel door and the store door, then reaches the yard gate and locks it. A cold store door on the unit takes the same round, and its seal must shut tight or the cold escapes with the day. The cold store doors guide covers the door, the seal and the cold behind it.
The yard gate closes the day. A vehicle gate that shuts behind each lorry keeps the yard closed between dispatches, and a pedestrian gate beside it keeps staff on foot apart from the lorries. The security gates guide deals with the vehicle gate, the foot way beside it and the lock on each one.
At open the dock takes the lorries, at close the gate takes the lock, and between them the personnel door takes every person through the day.
Reading the rating on a Thames Valley order: B3, C5 and D10
The LPS 1175 rating comes from two facts: which tools the doorset resists and how many minutes it holds. Three minutes against category B tools, screwdrivers, pliers and hand saws, earns B3. Five minutes against category C tools, crowbars, drills and chisels, earns C5. Ten minutes against category D tools, sledgehammers, disc cutters and jigsaws, earns D10. Earlier labels still turn up on drawings, so read SR2 as B3, SR3 as C5 and SR4 as D10.
Set the rating opening by opening, from the risk each one faces. A staffed front entrance suits B3, a rear door that faces a quiet yard suits C5, and a door guarding high value stock suits D10. The letter on its own says little, and so does the number: read them as a pair.
Two more standards sit beside LPS 1175 on a Reading order. PAS 24 is the enhanced security standard for doorsets, and EN 1627 gives resistance classes RC1 to RC6. A Secured by Design mark is a scheme mark, not a rating, so a mark on its own proves nothing about resistance: ask for the test rating behind it. The three ratings buyers meet most often are compared in our SR2 vs SR3 vs SR4 guide, and the two routes are compared in our LPS 1175 vs PAS 24 guide.
One doorset, two duties: fire and forced entry in Reading
One Reading assembly often carries two duties: it holds fire and resists a forced entry. A server room door keeps fire out and keeps an attacker from the equipment inside, and a plant room door does the same for a different risk. Each duty needs its own proof on that one assembly, a fire classification to EN 1634-1 and a forced entry rating to LPS 1175 or PAS 24. Our dual certification guide works through how the two proofs sit together.
FD30 and FD60 are the fire resistance periods from the EN 1634-1 furnace test, and the number is the minutes the doorset holds. FD30S adds smoke control to 30 minutes of integrity, proved to BS EN 1634-3, and EI caps the heat on the safe side at 140 degrees Celsius on average and 180 degrees at most. Change any part of the tested construction and the door carries no proven rating afterwards.
A leaf on its own proves nothing about the frame, the fixings, the glazing or the hardware round it, and a change to any of those parts can undo the construction that passed the test. Ask for the test report and the classification naming the exact doorset, and have both in hand before the order is placed. Our guide to keeping an LPS 1175 rating valid sets out what voids a rating after handover.
Glazed entrances and the screen behind the glass
A glazed entrance is only as strong as the screen behind the glass. The glass, the frame, the beads and the fixings are tested together, so a rated pane in an untested frame is not a rated entrance. Our fire rated glazed doors page covers the doors that pair rated glass with a rated frame.
When the alarm sounds, the same entrance has to let a crowd out in one movement. Doors serving more than 60 people need panic hardware to BS EN 1125, a bar that runs across at least 60 percent of the leaf so a crowd can find it without looking. BS 8300 and Approved Document M cap the opening force at 30 N in the first 30 degrees and 22.5 N beyond that, and a closer set too strong for the leaf puts the door outside those limits.
Premises that hold crowds fall inside the duties of Martyn’s Law. The law sets tiers for premises that hold 200 or more people, with Royal Assent in April 2025 and go-live expected in spring 2027. The doors that release a crowd sit inside those duties, and each one has to open in one action, in the direction of escape, without a key. Our Martyn’s Law guide works through the tiers and what they ask of a building.
The Oracle and Reading station: doors for crowds that never stop
The Oracle stands on the banks of the River Kennet in Reading, and its main shopping malls opened on 23 September 1999, with Riverside following in November 1999. The shopfront looks onto staffed trading hours in a lit mall, while the door at the rear looks onto a quiet service road once the shops shut, so the rear door needs the higher rating, because an attacker gets more time unseen. Name B3 for the staffed front and C5 for the rear door, and put the rating on the whole doorset, leaf, frame, fixings and hardware together.
The rebuilt Reading station was reopened on 17 July 2014 with 15 platforms, on the northern edge of the town centre. A station entrance works in waves, with crowds arriving for one train and leaving on the next. Fit panic hardware to BS EN 1125 on any door serving a room of more than 60 people, with the bar spanning 60 percent or more of the leaf. Royal Assent for Martyn’s Law came in April 2025, and the duties are expected to take effect in spring 2027. Premises holding 200 to 799 people fall in the standard tier, and premises holding 800 or more fall in the enhanced tier.
A door worked by a crowd all day needs its closer set to the right power size. BS EN 1154 gives EN 1 as the smallest power size, and EN 3 is the minimum on a fire door. BS 8300 and Approved Document M cap how hard the door may be to open: the force stays under 30 N through the first 30 degrees, then under 22.5 N after that. The transport hub security requirements guide works through station entrances, escape routes and the access control that sits beside them.
| Building | Door | Rating to name |
|---|---|---|
| The Oracle | Shopfront door | LPS 1175 B3 where rated |
| The Oracle | Service door | LPS 1175 C5 for a rear door |
| Reading station | Station entrance | FD30 with panic hardware |
| Select Car Leasing Stadium | Stadium exit doors | Panic hardware, BS EN 1125 |
Whiteknights, the stadium and the hospital: doors that serve Reading all day
The University of Reading bought Whiteknights Park in 1947, and Whiteknights is now the principal campus. Teaching rooms need doors that swing easily for a full class, laboratories need doors that guard people and equipment at once, and halls of residence need doors that admit residents and shut out strangers. The university security doors guide covers campus entrances, teaching blocks and laboratories, and the student accommodation guide covers the doors for halls of residence.
The Select Car Leasing Stadium opened on 22 August 1998 as the Madejski Stadium, and it holds 24,161 people as the home of Reading FC. A stadium exit has to let a whole crowd out in one movement, with no key and no code, and lock again once the match is over. Under BS EN 1935 the hinge grade follows the test cycles and the leaf mass: grade 13 is proved at 200,000 cycles with a 120 kg leaf, and grade 14 at the same cycles with a 160 kg leaf. The stadium security doors guide covers the exit doors, turnstile lanes and service doors a ground needs.
Royal Berkshire Hospital stands on London Road in Reading. A ward entrance must hold fire and open easily for beds, trolleys and staff in a hurry. Fire is tested to EN 1634-1, with FD30 and FD60 as the periods the doorset holds. The hospital security doors guide sets out ward, corridor and entrance doors for a hospital estate.
Start from the building, its crowd and its hours, and let those three facts choose the rating.
Access control across a Reading business park
One access system should cover every building on a Reading business park. Staff open doors with cards, visitors use a code or a pass, and a contractor credential stops working when the job ends.
The system has to admit the right people, shut out everyone else, and record who passed and when. Wire the doors, the turnstiles, the lifts and the car park into it together, so a card that stops working stops working everywhere. Decide the fail state in writing before the doors go in: a door that must stay locked for security and a door that must release for escape need opposite answers, and each answer should be proved with the power off. Our security turnstiles guide works through readers, fobs and biometrics and how the lane is wired into the access system.
Reading Borough Council: planning checks before the order
Most door swaps need no planning permission at all, where the new door sits in the old opening and nothing else changes. The exceptions are the cases buyers miss: a major change to the outside of the building, work inside a conservation area, and work on a listed building, which needs its own consent. Each of those three calls for a check with Reading Borough Council before the order goes in.
A listed building carries duties a new building never meets, and Reading Borough Council is the authority that grants the consent. Order the door before the consent is in place and the work can be ordered out again, so carry the listing and the conservation area in the enquiry beside the door schedule. A steel leaf set into a listed facade needs a finish and a fixing the conservation officer will accept.
The Reading enquiry: the schedule that orders the doors
Write a Reading order as a specification, not as a purchase from a catalogue. The enquiry should list the building and the position, the fire rating and the security rating where one is needed, and the leaf, the frame, the glass, the beads, the seals and the hardware as a single doorset. Where the door must also resist attack, ask for the security evidence on the whole doorset, a rating to LPS 1175 or PAS 24, and not a rating for the leaf alone. The same discipline, column by column, is covered in our how to specify security doors guide.
Ask for the evidence to travel with the doors, not behind them. The test report, the classification and the hardware schedule should arrive with the doorset, and the handover pack should name the inspection routine the site will follow. File the evidence on the day the doors arrive. Our fire door inspection checklist sets out the checks that catch a failing leaf before it matters.
| Premises | Door position | Rating | What to check |
|---|---|---|---|
| Business park office | Glazed entrance | LPS 1175 where rated | Screen rating, reader pace |
| Out-of-town office | Escape and entrance doors | FD30 or FD60 | Panic hardware, opening force |
| Distribution unit | Personnel door | LPS 1175 B3 or C5 | Steel leaf, hinges, latch |
| Distribution unit | Loading bay personnel door | LPS 1175 where rated | Closer, latch, hold-open release |
| Stores and plant room | Internal doors | FD60 | Seals, gaps, self-closing |
A Reading schedule has to treat a business park entrance and a distribution unit door as two different orders, even when they sit on the same estate.
What LPS 1175 rating suits a Reading business park office?
B3 fits a staffed front entrance and C5 fits a rear or side door that faces a quiet approach. The rating should follow the risk assessment for that opening.
Can one doorset carry a fire rating and a security rating in Reading?
Yes, if both proofs name the same doorset. EN 1634-1 gives the fire classification and LPS 1175 or PAS 24 gives the forced entry rating, and each one must name the doorset that will be fitted.
Do I need planning permission to replace a door in Reading?
A like-for-like replacement inside an existing opening usually needs none. A new opening, work in a conservation area, or work to a listed building calls for a check with Reading Borough Council first.
What should a glazed entrance in Reading be rated for?
The screen as a whole: the glass, the frame, the beads and the fixings tested together. A rated pane in an untested frame is not a rated entrance.
How do I order doors for several Reading sites?
One schedule does the job: one row per opening, naming the building, the position, the fire rating, the security rating and the whole doorset. Ask for the evidence to arrive with the doors.
Get a free quote
Other areas
Security doors in other areas
Ready to specify your project?
Free assessment, written specification and test evidence. Reply within one working day.