Security · LPS 1175 SR2 to SR5
Security Doors in Leeds
Security doors for Leeds offices, retail and distribution units: ratings, fire and security on one doorset, and what the enquiry should name.
- ✓Third-party test evidence with every product
- ✓Written specification you can issue to tender
- ✓Supplied and installed in Leeds
Get a free quote in Leeds
Rating, written specification and budget range within one working day.
Confidential. No cost, no obligation.
Third-party tested
Evidence with every quote
UK manufactured
Made to your sizes
One accountable team
Specify, supply, install
Confidential handling
Details never shared
Supplied and installed in Leeds
What we supply in Leeds
A Leeds buyer should start from the opening, not the catalogue. A rated steel door at B3 or C5 suits most city centre entrances and a fire rated doorset suits any escape route.
Leeds holds a large commercial centre with offices and retail, and distribution units on out-of-town sites, and each kind of building asks a different question of its doors. A city centre office needs an entrance that admits staff and visitors and keeps strangers out. A retail unit needs doors that take a crowd at opening time and still release in one action. A distribution unit needs a personnel door that takes a shift of workers every day.
The answer is a door schedule with one line per opening. Each line names the building, the position, the fire rating, the security rating where one is needed, and the leaf, the frame, the glass, the seals and the hardware as one doorset. Our Leeds page covers the city as a whole, and our Sheffield page covers the city to the south.
- LPS 1175Forced entry rating, B3 to D10
- PAS 24Enhanced security doorset standard
- FD30 / FD60Fire resistance periods tested to EN 1634-1
- BS EN 1125Panic hardware, bar across 60 percent of the leaf
City centre offices and retail: the doors the public meets
A city centre office in Leeds meets the public every day. Staff arrive in the morning, visitors arrive through the day, and deliveries arrive at the side door, so the entrance doors must admit the right people and keep strangers out. A glazed entrance lets reception see who is at the door before it is opened, and a rated screen holds while the door is checked. A screen that is not rated is a screen that fails at the first blow, and the entrance behind it is open. Our fire rated windows guide sets out how glass, frame and beads are tested together.
Retail doors face a different rhythm. A shopfront must take a crowd at opening time, and the same doors must release that crowd in one action if the alarm sounds. Panic hardware to BS EN 1125 belongs on these doors, with a bar across the leaf covering at least 60 percent of the leaf width, on doors that serve more than 60 people. A door must open with less than 30 N in the first 30 degrees and less than 22.5 N beyond that, under BS 8300 and Approved Document M. A closer that is too strong for the leaf makes the door fail the access rules. Our fire door closers guide sets out the power sizes in BS EN 1154.
Leeds station sets the pace for the doors south of the river
Leeds station handled 27.3 million entries and exits in 2024-25, which makes it the third busiest station in the UK outside London. A concourse that moves that many people needs doors that open in one action when the alarm sounds and hold a crowd at a controlled point while tickets are checked. Any door on a room that holds more than 60 people carries panic hardware to BS EN 1125, with its bar spanning at least 60 percent of the leaf. The transport hub security guide works through station doors and the ratings beside them.
South of the River Aire, the South Bank regeneration covers 253 hectares and aims to double the size of Leeds city centre, with 35,000 jobs and 8,000 homes in the framework. New offices, homes and public buildings on that land need door schedules written at design stage, not after fit-out. Each opening needs its own row: name the building and the position, then the fire period, then the security rating where the opening needs one, and the leaf, frame, glass, seals and hardware as one doorset. A schedule written late leaves the rating to chance. The how to specify security doors guide works through the same discipline column by column.
| Building | Door | Rating to name |
|---|---|---|
| Leeds station | Concourse and gateline doors | Panic hardware to BS EN 1125 |
| South Bank office | Glazed entrance | LPS 1175 B3 where rated |
| Kirkgate Market | Service doors | LPS 1175 C5 on the rear door |
| Corn Exchange | Shopfront and service doors | B3 front, C5 rear |
A Grade I listed market hall still trades every day behind its doors
Kirkgate Market is the largest covered market in Europe and a Grade I listed building. Its first covered sections were built in 1857, and it now holds 800 stalls that attract over 100,000 visitors a week. The Corn Exchange opened in 1864 to a design by Cuthbert Brodrick, and it is Grade I listed too, under a glass dome. Both buildings trade every day, so their doors take constant public use inside fabric that cannot be changed without consent. A steel leaf set into a listed frontage needs a finish and fixings that pass the conservation officer, so the planning check belongs at the start of the programme. Read the listed building fire doors guide before the order, so consent and the doorset are settled together.
The front of a market building trades in full view all day, so LPS 1175 B3 fits it. A rear service door opens onto a yard that falls quiet once the stalls close, so LPS 1175 C5 fits it. The same split suits the Corn Exchange, where independent shops trade behind the dome while deliveries come through the back. Fire sits beside security on these doors: FD30 or FD60 to EN 1634-1 on escape routes, with a 4 mm gap round the leaf and a closer sized to BS EN 1154, EN 3 minimum on a fire door. The retail security doors guide works through front and rear doors, and the fire door closers guide works through the power sizes.
Put the station, the South Bank, the market and the Corn Exchange on one schedule, and give each opening its own rating with the evidence beside it. The concourse door and the market hall door answer different questions, and the schedule is where that difference is caught.
Elland Road and the arena: doors that hold a crowd
Elland Road stands in Beeston, about 2 km south west of Leeds city centre, and holds 37,645 people. The first direct arena stands in the Arena Quarter of the city centre, opened in 2013, and holds 13,781 people. A football ground and an indoor arena put crowds through their doors in different ways: a ground fills once before kick off and empties once at the end, while an arena fills and empties several times in a week for concerts and shows.
Both buildings need doors that let a crowd in, hold it at a controlled point and let it out in one action when the alarm sounds. Rooms that hold more than 60 people need doors with panic hardware to BS EN 1125. The push bar must run across 60 percent of the leaf at least. Elland Road and the arena both sit far above the 800 person line for the enhanced tier of Martyn’s Law, the Terrorism (Protection of Premises) Act 2025. The Act gained Royal Assent in April 2025, and the duties are expected to begin in spring 2027. For what each tier asks for, see the Martyn’s Law guide for premises.
A turnstile line and a concourse door take more use in one afternoon than an office door takes in a week, so the hardware must be sized for that traffic. BS EN 1935 tests a hinge by how many cycles it survives and how heavy a leaf it can carry. A grade 13 hinge is tested to 200,000 cycles at 120 kg, and a grade 14 hinge is tested to 200,000 cycles at 160 kg. Put both figures on the schedule, so the hinge fitted on site is the hinge that passed the test. The stadium security doors guide gives the doors a ground needs, and the ratings beside them.
| Building | Door | Rating to name |
|---|---|---|
| Elland Road | Turnstile lines and concourse doors | Panic hardware to BS EN 1125 |
| first direct arena | Arena entrance and exit doors | Panic hardware, BS EN 1125 |
| Trinity Leeds | Mall entrance | Closer size to BS EN 1154, EN 3 minimum |
| Leeds General Infirmary | Ward door | Fire to EN 1634-1, force below 30 N |
Universities and hospitals: doors that serve a city centre campus
The University of Leeds received its royal charter in 1904, and its main campus stands beside Leeds General Infirmary in the north of the city centre. Leeds Beckett University keeps campuses in the city centre and at Headingley. The two universities run lecture rooms, laboratories, libraries and halls across the city, and their doors must take a crowd between lectures, hold fire on escape routes and control who passes.
Leeds General Infirmary has stood in the city centre since 1869, and St James’s University Hospital is one of the largest teaching hospitals in Europe. A ward door must shut on its own, hold fire for its rated period, and still open with a light push. BS 8300 and Approved Document M set the opening force under 30 N for the first 30 degrees. Past 30 degrees it drops to 22 and a half newtons. The hospital security doors guide gives ward doors in full, and the hospital fire door regulations guide gives the fire periods beside them.
Trinity Leeds opened in the city centre on 21 March 2013, and about 130,000 people came through its doors on the first day. A mall entrance takes the public all day, so the closer on it must keep its setting through constant use. Under BS EN 1154, EN 3 is the smallest power size to name on a fire door. A weaker closer cannot shut the leaf against its seals. The gap round the leaf matters as much as the closer: the check is 4 mm, and a wider gap lets smoke escape. The shopping centre security doors guide gives retail doors in full.
Put the stadium, the arena, the campuses and the hospitals on one schedule, with one rating per opening and the evidence filed beside it.
Distribution units and out-of-town sites: the doors that take the most use
A personnel door on a distribution unit opens and closes more often than any other door in Leeds. It opens for every shift change, every delivery and every break, and a door that is specified for a quiet office will not last on a unit floor. A door that will not last will be wedged open within a week, and a wedged door has no rating at all.
Steel takes the use. A steel leaf stands up to the knocks a distribution door meets every day: a trolley, a pallet, a boot, a crate. A steel leaf is strong, but strength on its own is not a security rating, and a door that resists a knock may still fail a forced entry test. The rating belongs to the complete tested assembly, leaf, frame, fixings, glazing and hardware tested together, so a rated leaf in an untested frame is not a rated door. Our warehouse security doors guide covers the doors distribution buildings need most.
A loading bay needs its own doors, and the bay door is not the personnel door. A high performance roller door opens and closes all day on a busy bay, and a personnel door beside it lets staff in and out without opening the bay. Our loading bay doors guide covers the bay doors in full.
What B3, C5 and D10 mean on a Leeds order
LPS 1175 rates a doorset by the tools and the time it resists. B3, the old SR2, resists three minutes of attack with tools such as screwdrivers, pliers and hand saws. C5, the old SR3, covers five minutes with crowbars, drills and chisels, and D10, the old SR4, covers ten minutes with sledgehammers, disc cutters and jigsaws. The rating is a letter and a number together, and both halves must be read together.
The rating should follow the risk for each opening, not the postcode. A shopfront in a busy commercial centre needs a higher rating than a store door in a quiet yard. Walk the site from outside and note every door a person can reach, then rate those doors for the attack they could face. Our keeping an LPS 1175 rating valid guide sets out the changes that void a rating, and our LPS 1175 vs PAS 24 guide compares the two routes side by side.
PAS 24 is the enhanced security standard for doorsets, and EN 1627 sets resistance classes RC1 to RC6 for windows, doors and shutters. Secured by Design is a scheme, not a rating, and a door that carries the scheme mark without a test rating has no proven resistance behind it. Our SR2 vs SR3 vs SR4 guide works through the three ratings buyers meet most often.
Fire and security on one Leeds doorset
Many doors in Leeds must do two jobs: hold fire and resist forced entry. A server room door must hold fire and resist an attack on the equipment inside. A plant room door must hold fire and resist a forced entry. The two jobs need two sets of evidence on one assembly: a fire classification to EN 1634-1 and a forced entry rating to LPS 1175 or PAS 24. Our dual certification guide works through how fire and security sit on one assembly.
FD30 and FD60 are fire resistance periods tested to EN 1634-1, and the number is the minutes the doorset holds its rating in the furnace test. A door marked FD30S carries 30 minutes of integrity plus smoke control, tested to BS EN 1634-3. EI adds an insulation limit on temperature rise on the safe side, an average of 140 degrees Celsius and a maximum of 180 degrees Celsius. A change to the leaf, the frame, the glass, the seals or the hardware can break the tested construction, and a door that has been changed without fresh evidence has no proven rating.
Access control across a Leeds estate
An estate that holds sites across Leeds needs one access system, not one per site. Staff carry cards, visitors use a code or a pass, and contractors use a temporary credential that expires when the work ends. Each method suits a different entrance: a city centre office needs readers that work at walking pace, and a distribution unit needs cards that work at shift change.
The system should open for the right people and stay closed for everyone else, and it should keep a record of who passed and when. The doors should work with the same system as the turnstiles, the lifts and the car park, so a person who loses access loses it everywhere at once. Our security turnstiles guide works through readers, fobs and biometrics and how the lane is wired into the access system.
Finishes and hardware that last on a Leeds site
How long a door lasts is decided by its finish, and the choice follows the exposure the door faces. Powder coating gives colour and a hard surface, and suits sheltered doors. Galvanising gives a zinc coating that protects the steel itself, including edges and cut sections, and suits doors facing wet weather. A galvanised base with a powder coated top coat gives both, so ask which finish the tested doorset allows. Our powder coating page covers the finish options.
Hinges and fixings need the same thought as the leaf. Hinges to BS EN 1935 carry the leaf, grade 13 or grade 14, and a hinge that has dropped lets the leaf sag, so the closer cannot close it squarely. A hold-open device to BS EN 1155 lets a door stand open for use and releases it when the alarm sounds, so test the release at every inspection. Check the gaps and the seals on the same visit: a 4 mm gap around the leaf is the usual limit, and intumescent seals close the gap in a fire by expanding at roughly 200 to 250 degrees.
Planning checks with Leeds City Council
Most like-for-like door replacements inside an existing opening need no planning permission, but three cases need a check with Leeds City Council before ordering. First, major alterations to the outside of a building can need planning permission. Second, work in a conservation area faces additional controls. Third, listed buildings need separate consent, and this is the case buyers miss most often.
A listed building carries duties a new building does not, and a door fitted without the right consent can be ordered out again. The planning authority names what is needed, so the enquiry should name the listing and the conservation area beside the door schedule. A steel leaf in a listed facade needs a finish and a fixing the conservation officer will accept, so start the planning early and put its time in the programme from the start.
Ordering for a Leeds site: what the enquiry should name
Ordering doors for a Leeds site is a specification exercise, not a shopping exercise. The enquiry should name the building, the position, the fire rating, the security rating where one is needed, and the leaf, the frame, the glass, the beads, the seals and the hardware as one doorset. The security side needs its own evidence where the door must also resist attack: a rating to LPS 1175 or PAS 24, on the whole doorset, not on the leaf alone. Our how to specify security doors guide covers the same discipline column by column.
Ask for the evidence with the doors. The test report, the classification and the hardware schedule should arrive with the doorset, and the handover pack should name the inspection routine the site will follow. A site that files the evidence on the day the doors arrive has a record it can use for the whole life of the estate. Write the schedule first, then order against it. Our fire door inspection checklist gives the checks that catch a failing leaf before it matters.
| Premises | Door position | Rating | What to check |
|---|---|---|---|
| City centre office | Glazed entrance | LPS 1175 where rated | Screen rating, reader pace |
| Retail unit | Escape and entrance doors | FD30 or FD60 | Panic hardware, opening force |
| Distribution unit | Personnel door | LPS 1175 where rated | Steel leaf, hinges, latch |
| Stores and plant room | Internal doors | FD60 | Seals, gaps, self-closing |
In Leeds, the door that suits a city centre office does not suit a distribution unit.
What LPS 1175 rating do I need for a Leeds office door?
For most city centre entrances, B3 suits a staffed front entrance and C5 suits a rear or side door facing a quiet approach. The rating should follow the risk assessment for that opening.
Can one doorset carry a fire rating and a security rating?
Yes, where one construction holds both proofs. The fire classification comes from a test to EN 1634-1 and the forced entry rating from a test to LPS 1175 or PAS 24, and the two must be proved on that same doorset.
Do I need planning permission to replace a door in Leeds?
Most like-for-like replacements inside an existing opening need none, but a new opening, work in a conservation area, or work to a listed building needs a check with Leeds City Council before ordering.
What finish suits a Leeds distribution unit door?
A galvanised finish fits a door that faces wet weather, because the zinc coating protects the steel itself, edges and cut sections included. Check that the tested doorset allows the finish before ordering.
How do I order doors for more than one Leeds site?
Write one door schedule with one line per opening, naming the building, the position, the fire rating, the security rating and the whole doorset. Ask for the evidence with the doors, and file it on the day the doors arrive.
Before you ask for a quote, run through the security door enquiry checklist so each opening arrives with its size, use and rating.
Get a free quote
Other areas
Security doors in other areas
Ready to specify your project?